PRIMERGY ECONEL 100 S2 環境設定シート

Size: px
Start display at page:

Download "PRIMERGY ECONEL 100 S2 環境設定シート"

Transcription

1

2 Microsoft Windows Windows Server Microsoft Corporation Xeon Pentium Celeron Core 2 Duo Intel Corporation

3

4 ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160 GB ( ) 500 GB 1 5 ( ) (PG-RD1021) ( ) DAT72(PG-DT5043) SCSI ID 2DVD-ROM RAM DIMM 1A DIMM 2A DIMM 1B DIMM 2B RAM ( ) 512 MB ( ) 1 GB ( ) 2 GB ( ) 512 MB ( ) 1 GB ( ) 2 GB ( ) 512 MB ( ) 1 GB ( ) 2 GB ( ) 512 MB ( ) 1 GB ( ) 2 GB CPU CPU ( ) Celeron 430 (1.86GHz/512KB) ( ) Xeon 3065 (2.33GHz/4MB) ( ) Pentium E2180 (2GHz/1MB) ( ) Xeon E3110 (3GHz/6MB) ( ) Xeon E3120 (3.16GHz/6MB) ( ) Core 2 Duo TM E4600 (2.4GHz/2MB) ( ) PCI LANPG-1853 SAS PG-248BC PG-PP08 PCI ( ) ( ) ( )

5 . Main System Time: HH:MM:SS System Date: Month Day Year Diskette A: 1.4M ( )None ( )360K ( )1.2M ( )720K > SATA Port1: ST AS-(S1) Standard IDE SATA Port2: None SATA Port3: None SATA Port4: None > SATA Port5: HL-DT-STDVD-RAM-(S5) SATA Port6: None > Boot Features Boot Features Base Memory: xxxk 1MB() Extended Memory: xxxm 1MB ()

6 SATA Port x : [Device] Total Sectors: Maximum Capacity: Multi-Sector Transfers: 32 Bit I/O: Transfer Mode: Ultra DMA Mode: SMART Monitoring: Firmware: Password Status: Change Password: Not supported [Press Enter] /LBA Mode/DMA / Firmware() Boot Features Boot Features POST Errors: Enabled ( )Disabled SM Error Halt: Enabled ( )Disabled Keyboard Check: Enabled ( )Disabled Fast Boot: Disabled ( )Enabled Post Diagnostic Screen: Enabled ( )Disabled Boot Menu: Enabled ( )Disabled NumLock: Auto ( )On ( )Off. Advanced Setup Warning Setting items on this menu to incorrect values may cause your system to malfunction > Peripheral Configuration Peripheral Configuration > Advanced System Configuration Advanced System Configuration > Advanced Processor Options Advanced Processor Options > PCI Configuration PCI Configuration > System Management System Management > Console Redirection Console Redirection

7 Peripheral Configuration Peripheral Configuration Serial 1: Auto ( )Disabled ( )Enabled Serial 1 Address: *1 3F8h ( )2F8h ( )3E8h ( )2E8h Parallel port: Disabled ( )Enabled ( )Auto Mode: *2 Bidirection ( )Printer ( )EPP ( )ECP Parallel Address: *3 378h,IRQ 7 ( )278h,IRQ 5 Diskette Controller: Enabled ( )Disabled USB Front: Enabled ( )Disabled USB Rear: Enabled ( )Disabled USB Devices: ALL ( )None ( )Keyboard And Mouse Only LAN Controller: Enabled ( )Disabled LAN Remote Boot: Disabled ( )Enabled *1 Serial1 Enabled *2 Parallel port Auto Enabled *3 Parallel port Enabled Advanced System Configuration Advanced System Configuration Onboard Video: Enabled ( )Disabled High Precision Event Timer: Enabled ( )Disabled SMART Device Monitoring: Enabled ( )Disabled SATA RAID Enable: *1 SATA OS: Disabled ( )Enabled SATA RAID(MegaSR): Enabled ( )Disabled SAS : Disabled ( )Enabled SATA AHCI Enable: *1,2 SATA OS: Disabled ( )Enabled SATA RAID(MegaSR): Enabled ( )Disabled SAS : Disabled ( )Enabled PCI Bus SERR Checking: Enabled ( )Disabled *1 SAS Get Default Values Disabled *2 SATA RAID Enable Disabled

8 Advanced Processor Options Advanced Processor Options *1 CPU Mismatch Detection *2 Enabled ( )Disabled Enhanced SpeedStep: *3 Disabled ( )Enabled CPU Halt Mode: *4 Enhanced ( )Disabled Enhanced Idle Power State: *3 Disabled ( )Enabled CPU Thermal Management: Enhanced ( )Standard Virtualization Technology: *5 Disabled ( )Enabled NX Memory Protection: Disabled ( )Enabled Adjacent Cache Line Prefetch: Enabled ( )Disabled Hardware Prefetch: Enabled ( )Disabled Core Multi-Processing: *3 Enabled ( )Disabled Limit CPUID Functions: Disabled ( )Enabled CPU MC Status Clear: Next Boot ( )Disabled ( )Enabled *1CPU *2 BIOS R1.06 *3 Celeron 430 *4 Load Default(Get Default Values)BIOS Setup *5 Celeron 430 / Pentium E2180 PCI Configuration PCI Configuration > PCI SLOTS Configuration PCI SLOTS Configuration PCI IRQ Line 1 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 2 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 3 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 4 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 5 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 6 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 7 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15 PCI IRQ Line 8 : Auto Select ( )Disabled ( )IRQ3 ( )IRQ4 ( )IRQ5 ( )IRQ6 ( )IRQ7 ( )IRQ9 ( )IRQ10 ( )IRQ11 ( )IRQ12 ( )IRQ14 ( )IRQ15

9 PCI SLOTS Configuration PCI SLOTS Configuration Slot 1 Configuration Option ROM SCAN: Disabled ( )Enabled Slot 2 Configuration Option ROM SCAN: Disabled ( )Enabled Slot 3 Configuration Option ROM SCAN: Enabled ( )Disabled Slot 4 Configuration Option ROM SCAN: Disabled ( )Enabled System Management System Management Battery State SM Fan Control: Auto ( )Enhanced Cooling ( )Silent Fan State Power Supply FAN 1 FAN 2 FAN 3 Thermal Sensor State CPU Inside System Hard Disk FAN FAN 1() FAN 2 (Front) FAN 3 (Rear) CPU Console Redirection Console Redirection *1 Com Port Address: *1 Disabled ( )Serial 1 Baud Rate: * ( )300 ( )1200 ( )2400 ( )19.2K ( )38.4K ( )57.6K ( )115.2K Console Type: *1 VT100+ ( )VT100 ( )VT100,8bit ( )PC-ANSI,7bit ( )PC ANSI ( )VT-UTF8 Flow Control: *1 CTS/RTS ( )None ( )XON/XOFF Continue C.R. after POST: *1 On ( )Off *1 BIOS R1.06

10 . Security Supervisor Password Not installed Supervisor Password User Password *1 Not installed User Password Set Supervisor Password: Press Enter Supervisor Password Setup Password Lock: *2 Standard ( )Extended Set User Password: *2 Press Enter User Password User Password Mode: *3 Standard ( )Keyboard Password on boot: *2 Disabled ( )Enabled System Password Lock: *4 Standard ( )WOL Skip > TPM (Security Chip) Setting TPM (Security Chip) Setting Virus Warning: Disabled ( )Enabled ( )Confirm Diskette Write: Enabled ( )Disabled Flash Write: Enabled ( )Disabled *1 Set Supervisor Password *2 Supervisor Password *3 Set User Password *4 Password on boot Enabled TPM (Security Chip) Setting Security Chip Disabled ( )Enabled Current TPM State Disabled and Deactivated Change TPM State *1 No Change ( )Enabled & Activate ( )Disable & Deactivate ( )Clear *1 Security Chip Enabled. Power Power On Source: BIOS Controlled ( )ACPI Controlled LAN: *1 Enabled ( )Disabled Wake Up Timer: *1 Disabled ( )Enabled Wake Up Time: *2 [00:00:00] Wake Up Mode: *2 Daily ( )Monthly Wake Up Day: *3 1 [0-31] Power Failure Recovery: Previous State ( )Always Off ( )Always On ( )Disabled *1 Power-On Source BIOS Controlled *2 Wake Up Timer Enabled *3 Wake Up Mode Monthly 0( )

11 . Boot Boot Boot priority order: 1: IDE CD:CD *1 2: Legacy Floppy Drives 3: IDE x:hdd *2 4: PCI BEV:Boot Manage PXE,Slot 00C8 *3 5: USB KEY: RDX *4 6: 7: 8: Excluded from boot order: :Legacy Network Card :Bootable Add-in Cards *1:DVD/CD-ROM Mode Native IDE CD: PCI BEV: Embedded RAID CD/DVD-ROM MegaSR ( Get Default Values HDD) *2:HDD Mode Native IDE x: MegaSR PCI SCSI: ICHx/ESB2 Embedded RAID SAS PCI SCSI: (Bus01 Dev00)PCI RAID Ad (PG-248BC) *3:LAN Remote Boot Enabled *4:PG-RD1021. Exit Save Changes & Exit: Discard Changes & Exit: Get Default Values: Load Previous Values: CMOS Setup Utility CMOS Setup Utility CMOS

12 I/Oh C C C BIOS BIOS I/O

13 . Embedded MegaRAID SATA HDD 1 PG-HDF67B 160GB [0] 2 PG-HDF67B 160GB [0] [ ] [ ] [ ] [ ] LD No. LD : 0 LD : 1 LD : LD : LD : LD : RAID ( )RAID 1 ( )RAID 1 ( )RAID 1 ( )RAID 1 ( )RAID 1 ( )RAID MB MB

14 . RAID 5/6 SAS based on LSI MegaRAID PCI HDD / 1 PG-HDB75A 73.4GB 2 PG-HDB75A 73.4GB HDD HDD ( ) [0] ( ) ( ) [0] ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] ( ) ( ) [ ] ( )

15 PCI LD No. *1 LD : 0 DG : 0 LD : 1 DG : 0 LD : DG : LD : DG : LD : DG : LD : DG : LD : DG : LD : DG : LD : DG : LD : DG : DG No. *2 RAID *3 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID 10 ( )RAID 1 ( )RAID 5 ( )RAID 6 ( )RAID MB MB ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU ( ) ( ) ( )BBU * *2 *3

16 . RAID/ ( ) ( ) ( ) RAID ( ) SCSI ( ) Fibrechannel( ) IDE RAID ( ) ( ) ( ) RAID RAID RAID ( ) ( ) ( ) NTFS ( ) FAT ( ) ( ) MB ( ) ( ) ( ) Boot ( ) OS ( ) Data

17 . OS Administrator OS ServicePack(SP) Windows 2003 Windows Server 2003/R2 ( ) Windows Server 2003, Standard Edition ( ) Windows Server 2003 R2, Standard Edition Windows Server 2003 x64/r2 ( ) Windows Server 2003, Standard x64 Edition ( ) Windows Server 2003 R2, Standard x64 Edition ( ) ( ) ServicePack1 ( ) ServicePack2 ( ) ( ) ( ) ( ) MYUSERGROUP ( ) CD ( ) R2 ( ) Windows Server 2003 R2 ( ) CDR2 R2 ( ) R2 (GMT+09:00) ( ) ( ) ( ) C: ( ) D: ( ) E: ( ) F: ( ) G: ( ) H: ( ) I: ( ) J: ( ) K: ( ) L: ( ) M: ( ) N: ( ) O: ( ) P: ( ) Q: ( ) R: ( ) S: ( ) T: ( ) U: ( ) V: ( ) W: ( ) X: ( ) Y: ( ) Z: ( ) ( ) winnt ( )

18 ( ) 640 * 480 ( ) 800 * 600 ( ) 1024 * 768 ( ) 1156 * 864 ( ) 1280 * 1024 ( ) 1600 * 1200 ( ) 60 ( ) 70 ( ) 72 ( ) 75 ( ) 80 ( ) 85 ( ) 100 ( ) 16 ( ) 256 ( ) High Color 16 ( ) True Color 24 ( ) True Color 32 ( ) ( ) DHCPTCP/IP IP ( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk ( ) DLC ( ) NetMon ( ) PPTP ( ) D H C IP P DNS DNS WINS ( ) WINS DHCP ( ) DHCPNetBIOS NetBIOS ( ) NetBIOS over TCP/IP ( ) NetBIOS over TCP/IP NWIPX 0x 0x DHCPTCP/IP IP D H C IP P DNS DNS WINS ( ) WINS DHCP ( ) DHCPNetBIOS NetBIOS ( ) NetBIOS over TCP/IP ( ) NetBIOS over TCP/IP NWIPX 0x 0x ( ) TCP/IP ( ) NWIPX ( ) NetBEUI ( ) Apple Talk ( ) DLC ( ) NetMon ( ) PPTP ( ) ()

19 R2 R2 R2 ( ) ( ) Active Directory NFS Microsoft UNIX Windows SharePoint Services ( ) Active Directory Application Mode ADAM ( ) ( ) WindowsNT ( ) ( ) SSL ( ) DFS ( ) DFS ( ) ( ) ( ) NFS Microsoft ( ) NFS ( ) NFS ( ) RPC ( ) RPC (XDR) ( ) NFS ( ) ( ) ( ) NIS ( ) Windows SharePoint Services ( ) ( ) Microsoft.NET Framework 2.0 ( ) Microsoft.NET Framework 2.0 Language Pack ( ) ( ) SAN ( ) ( ) UNIX ( ) ( ) DFS ( ) DFS ( )

20 ASP.NET IIS ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) FrontPage 2002 Server Extensions ( ) FTP (File Transfer Protocol) ( ) NNTP Service - NNTP Service ( ) SMTP Service - SMTP Service ( ) WWW (World Wide Web) - Active Server Pages ( ) WWW (World Wide Web) - WebDAV ( ) WWW (World Wide Web) - WWW ( ) WWW (World Wide Web) - ( ) WWW (World Wide Web) - HTML) ( ) ( ) (HTML) COM+ ( ) DTC ( ) ( ) ( ) ( ) ( ) ( ) ( ) CA ( ) WEB ( ) ( ) POP3 ( ) POP3Web FTP FTP FTP \Inetpub\Ftproot WWW WWW WWW \Inetsrv\WWWroot ( ) ( ) ( ) ( ) ( )

21 SNMP ( ) Macintosh ( ) Macintosh ( ) UNIX ( ) WindowsWINS ( ) ( ) DNS ( ) TCP/IP ( ) DHCP ( ) ( ) SNMP-ServerView SNMPSNMP ( ) ( ) ( ) ( ) ( ) End-to-End ( ) ( ) Active Directory (DNS ) Active Directory ( ) ( ) ( ) Active Directory ( ) ( ) SYSVOL Windows 2000OS ( ) DNS NetBIOS DNS DNS NetBIOS DNS NetBIOS

22 . OS Windows 2008 ( ) ( ) Microsoft ( ) Windows Server 2008 Standard ( ) Windows Server 2008 Enterprise ( )Core ( ) ( )x86 ( )x64 ( ) OS CD ( ) ( ) MYUSERGROUP ( ) 640 * 480 ( ) 800 * 600 ( ) 1024 * 768 ( ) 1156 * 864 ( ) 1280 * 1024 ( ) 1600 * 1200 ( ) 60 ( ) 70 ( ) 72 ( ) 75 ( ) 80 ( ) 85 ( ) 100 ( ) 1 ( ) 4 ( ) 8 ( ) 15 ( ) 16 ( ) 24 ( ) 32 ( ) ( ) ( ) yes ( ) no

23 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) SNMPSNMP SNMP ( ) ( ) ( ) ( ) ( ) End-to-End ( ) ( ) ( ) RAS ( ) LAN ( ) RAS LAN ( ) WAN ( ) RAS WAN ( ) LAN WAN ( ) RAS LAN WAN ( ) ( ) ( )

24 . ( ) RAS ( ) ServerView / RAID ( ) ServerView (Apache ) ( ) ServerView (IIS ) ( ) HRM / server ( ) REMCS ( ) UpdateAdvisor ( ) DSNAP ( ) PROBEPRO ( ) ( ) Windows Server 2003 ServicePack2 ( ) Windows Server 2003 /R2 ( ) Windows Server 2003 x64/r2 X64 ( ) Windows Server 2008 ( ) Windows Server 2008 x64 ( ) ( ) ( ) ( )

25 OS LAN WAN

26

PRIMERGY ECONEL 100 環境設定シート

PRIMERGY ECONEL 100  環境設定シート Pentium Intel Corporation 3.5 0 1 2 3 3.5 ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160 GB ( ) 500 GB 1* 2 5 ( ) DVD-RAMPG-DVA102D ( ) DVD-RAM(PGBDVAU105) ( ) DAT72 PG-DT5041 SCSI ID *) 1CD-ROMDVD-RAM

More information

環境設定シート

環境設定シート IntelXeon Intel Corporation 3.5 1 2 3 4 5 3.5 10,000rpm 15,000rpm ( ) 73.4GB ( ) 146.8GB ( ) 300GB ( ) 73.4GB ( ) 146.8GB ( ) 73.4GB ( ) 146.8GB ( ) 300GB ( ) 73.4GB ( ) 146.8GB ( ) 73.4GB ( ) 146.8GB

More information

IP1_ug.book

IP1_ug.book 1 1 2 Press to enter SETUP 1 2 1 Press to enter SETUP Enter passord[ ] Phoenix TrustedCore(tm) Setup Utility Main Advanced Security System Hardare

More information

Express5800/110Geユーザーズガイド

Express5800/110Geユーザーズガイド 2 Press to enter SETUP or Press to boot from Netork Press to Run LSI Softare RAID Configuration Utility. Press for SCSISelect(TM) Utility! 1

More information

1 124

1 124 7 1 2 3 4 5 6 7 8 9 10 11 12 1 124 Phoenix - AwardBIOS CMOS Setup Utility Integrated Peripherals On-Chip Primary PCI IDE [Enabled] IDE Primary Master PIO [Auto] IDE Primary Slave PIO [Auto] IDE Primary

More information

Express5800/i110Rc-1hユーザーズガイド

Express5800/i110Rc-1hユーザーズガイド 3 Press to enter SETUP Enter passord [ ] Main System Management Console Redirection Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring

More information

1 138

1 138 5 1 2 3 4 5 6 7 8 1 138 BIOS Setup Utility MainAdvancedSecurityPowerExit Setup Warning Item Specific Help Setting items on this menu to incorrect values may cause your system to malfunction. Select 'Yes'

More information

EQUIUM EQUIUM S5010 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 8 4 1 2 3 5 1 2 1 2 3 4 5 6 7 6 1 3 7 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 4 5 6 7 8 1 1 2 3 4 10 1 11 12 1 13 14 1 15 1 16 1 1 17 1 2 18 3 1 4 5 19

More information

EQUIUM EQUIUM 1

EQUIUM EQUIUM 1 EQUIUM EQUIUM 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 8 9 4 1 2 3 5 1 2 3 1 2 3 4 5 6 7 6 1 3 7 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 4 5 6 7 8 9 10 1 1 2 3 4 12 1 13 14 1 15 16 1 17 18 1 1 1 19 1 2 20 3 1

More information

本機をお使いの方へ

本機をお使いの方へ MA46H/S Windows 98 / NT 4.0 Windows 98 / NT 4.0 MA46H/S BIOS 1999 10 808-877675-132-A 3 AT 6. 1. BIOS P.7 1. Windows 98 Windows Windows 98 Microsoft Windows 98 Windows NT 4.0 Microsoft Windows NT Workstation

More information

iStorage NS47Pユーザーズガイド

iStorage NS47Pユーザーズガイド 5 Press to enter SETUP or Press to boot from Netork Enter passord[ ] Main Phoenix cme FirstBIOS Pro Setup Utility Advanced Security Server Boot Exit System Management Console Redirection Event

More information

橡EN1165.PDF

橡EN1165.PDF G780(7ZMMP-KK F1C) BIOS Setup 1 G780(7ZMMP-KK F1C) 2 G780(7ZMMP-KK F1C) 3 G780(7ZMMP-KK F1C) 4 G780(7ZMMP-KK F1C) 1st Boot Device 2nd Boot Device 3rd Boot Device S.M.A.R.T. for Hard Disks BootUp Num-Lock

More information

NEC Express5800/E110b-Mユーザーズガイド

NEC Express5800/E110b-Mユーザーズガイド 2 Press to enter SETUP Press to enter SETUP or to Network Press to resume, to enter Setup, to Network Enter password[ ] Main Phoenix SecureCore(tm)

More information

PRIMERGY TX150S5/TX150W S5 環境設定シート

PRIMERGY TX150S5/TX150W S5 環境設定シート XeonPentiumCeleron Intel Corporation 3.5 3.5 1 ( ) 73.4 GB ( ) 146.8 GB 2 ( ) 73.4 GB ( ) 146.8 GB 3 ( ) 73.4 GB ( ) 146.8 GB 4 ( ) 73.4 GB ( ) 146.8 GB 5 SCSI ID 1 ( ) DVD-RAM PG-DVA102D ( ) DVD-RAM

More information

T120Ra-1ユーザーズガイド

T120Ra-1ユーザーズガイド 3 Press to enter SETUP Enter passord[ ] Main System Management Console Redirection Event Log Configuration PhoenixBIOS Setup Utility Advanced Security Server Boot Exit Assert NMI on PERR : [Enabled]

More information

1 2

1 2 1 1 2 1 2 3 4 5 3 2 3 4 4 1 2 3 4 5 5 5 6 7 8 1 1 2 1 10 1 3 1 11 2 12 2 3 1 13 2 14 2 3 1 15 2 16 2 3 1 17 2 1 2 3 4 5 18 2 6 7 8 3 1 1 2 19 2 20 2 3 1 21 2 22 2 3 1 23 2 24 2 3 1 25 2 26 2 3 1 27 2 28

More information

EQUIUM EQUIUM S5010 1

EQUIUM EQUIUM S5010 1 EQUIUM EQUIUM S5010 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 4 1 2 5 1 2 6 1 7 1 2 3 4 5 6 7 1 2 3 4 5 6 3 7 8 9 1 2 3 4 4 5 6 7 8 1 1 2 3 4 10 1 11 12 1 13 14 1 15 16 1 1 2 3 17 1 2 3 18 4 5 6 1 19 1 2 3

More information

b7fh pdf

b7fh pdf PRIMERGY TX0FT S4 環境設定シート 本書の読み方 A コンフィグレーション本サーバにおけるハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX0FT S4 本文中の表記 本サーバ またはサーバ 商標 各製品名は

More information

iExpress5800/N サーバハードウェア

iExpress5800/N サーバハードウェア Press F2 to enter SETUP/Q-Flash Main A Date (mm:dd:yy) Time (hh:mm:ss) >IDE Primary Master IDE HDD Auto-Detection Press Enter Write Cache Disabled Enabled IDE Primary Master Auto None Manual Access

More information

5 1 2 3 4 5 6 7 8 9 10 1 Quick Boot 1st Boot Device 2nd Boot Device 3rd Boot Device Network Boot Initial Display Mode S.M.A.R.T. for Hard Disks BootUp Num-Lock Password Check CPU Serial Number System BIOS

More information

Express5800/110Gd-Sユーザーズガイド

Express5800/110Gd-Sユーザーズガイド 2 2 1 1 2 Press to enter SETUP or Press to boot from Netork Press to Run LSI Logic Softare RAID Setup Utility. Press for SCSISelect(TM) Utility! Press

More information

94

94 4 1 2 3 4 5 6 7 8 9 10 11 12 94 4 95 1 2 3 4 96 5 5 4 97 98 1 2 3 4 99 4 100 5 6 1 2 4 101 1 2 3 4 5 1 2 3 4 102 1 2 3 4 4 103 1 2 104 1 2 3 4 4 5 105 1 2 106 4 107 108 1 2 3 4 4 109 1 2 3 4 110 1 2 3

More information

PRIMERGY RX100 S4 環境設定シート

PRIMERGY RX100 S4 環境設定シート XeonPentiumCeleron Intel Corporation 3.5 1 2 3.5 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB CD-ROM 5 ( ) ( ) CD-ROMPGBCD324 ( ) DVD-RAM(PGBDVA102) RAM ( ) 512 MB ( ) 1 GB

More information

1 2

1 2 1 1 2 1 2 3 4 5 3 2 3 4 4 1 2 3 4 5 5 5 6 1 1 2 1 8 1 3 1 9 2 10 2 3 1 11 2 12 2 3 1 13 14 2 2 3 1 15 2 1 2 3 4 5 16 2 6 7 8 3 1 1 2 17 2 18 2 3 1 19 2 20 2 3 1 21 2 22 2 3 1 23 2 24 2 3 1 25 2 26 2 3

More information

Express5800/iR110a-1Hユーザーズガイド

Express5800/iR110a-1Hユーザーズガイド 3 w w w w w Press to enter SETUP Enter password [ ] Main System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot

More information

1 122

1 122 6 1 2 3 4 5 6 1 122 PhoenixBIOS Setup Utility MainAdvancedSecurityPowerExit MainSystem DevicesSecurityBootExit System Time: [XX:XX:XX] [XX:XX:XX] System Date: [XX/XX/XX] [XX/XX/XXXX] Item Specific Help

More information

1 2

1 2 1 1 2 3 1 2 3 4 5 2 3 4 4 1 2 3 4 5 5 5 6 1 1 2 3 1 8 1 3 1 9 2 10 2 3 1 11 2 12 13 3 1 2 2 14 2 3 1 15 2 16 2 3 1 17 2 18 2 3 1 19 3 20 3 3 1 21 3 22 3 3 1 23 3 24 3 3 1 25 3 26 3 3 1 27 3 28 3 3 1 29

More information

Express5800/110Gbユーザーズガイド

Express5800/110Gbユーザーズガイド 2 OUTPUT UN(SWITCH OUT) AC100V 50/50HZ TOTAL 12.5A OUTPUT(SWITCH OUT) Press to enter SETUP or Press to boot from Netork Press for Adaptec RAID Configuration Utility! Press

More information

Express5800/320Lb, 320Lb-R, 320Lb2-R, 320Lc, 320Lc-Rユーザーズガイド(セットアップ編)

Express5800/320Lb, 320Lb-R, 320Lb2-R, 320Lc, 320Lc-Rユーザーズガイド(セットアップ編) 4 B 1 2 Phoenix BIOS S etup Utility Main Advanced Security System Hardare Boot Exit Processor Type : Processor Speed : Cache RAM : System Memory : Extended Memory : Intel (R) Xeon (TM) processor 2.80

More information

iStorage NS500Rbユーザーズガイド

iStorage NS500Rbユーザーズガイド 5 w w w w w Press to enter SETUP or Press to boot from Network Enter Password Main System Management BMC LAN Configuration Event Log Configuration Advanced Security Server Boot Save & Exit Additional

More information

1 144

1 144 5 1 2 3 4 5 6 7 8 9 10 11 12 1 144 AMIBIOS SETUP - POWER MANAGEMENT SETUP (C)1999 American Megatrends, Inc. All Rights Reserved ACPI Standby State Power Management/APM Video Power Down Mode Hard Disk Power

More information

Express5800/340Hb-Rユーザーズガイド(セットアップ編)

Express5800/340Hb-Rユーザーズガイド(セットアップ編) 4 B 1 2 Phoenix BIOS Setup Utility Main Advanced Stratus Security Boot Exit System Time : System Date : Primary Master Primary Slave [15:23:34] [01/30/2004] CD-ROM ATRPI Removable Item Specific Help

More information

137 6 1 2 3 4 5 6 138 6 139 1 2 3 4 5 6 140 6 141 1 2 1 2 142 6 3 143 1 2 144 6 145 1 2 3 4 5 146 6 147 1 1 148 6 1 2 149 1 2 1 2 150 6 151 152 6 1 2 153 1 2 3 154 1 2 6 3 155 156 6 157 158 1 6 2 159 1

More information

5 1 2 3 4 5 6 7 8 9 10 11 12 1 132 CMOS Setup Utility - Copyright (C) 1984-2000 Award Software Power Management Setup ACPI Suspend Type S3 (STR) Power Management User Define Video Off Method DPMS Video

More information

1 142

1 142 7 1 2 3 4 5 6 7 8 1 142 PhoenixBIOS Setup Utility MainSystem DevicesSecurityPowerOthersBootExit System Time: [XX:XX:XX] Item Specific Help System Date: [XX/XX/XXXX] Floppy Drive: 1.44MB, 3 1 / 2" Hard

More information

Express5800/120Rj-2 ユーザーズガイド

Express5800/120Rj-2 ユーザーズガイド 2 ID 0 1 3 4 2 5 1 2 2 1 0 3 1 4 2 5 A 2 1 1 2 0 3 1 4 2 5 Press to enter SETUP, to Netork Press for SCSISelect(TM) Utility! 0 3 1 4 2 5 0 1 3 4 2

More information

PRIMERGY MX130 S1 環境設定シート

PRIMERGY MX130 S1 環境設定シート PRIMERGY MX130 S1 環境設定シート 本書の読み方 A B C D E ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます システム資源管理表各種拡張カードで選択できる I/O ポートアドレスについて説明しています デザインシート (Windows)

More information

5 1 2 3 4 5 6 7 8 9 10 11 12 1 146 CMOS Setup Utility - Copyright (C) 1984-2000 Award Software Power Management Setup ACPI Suspend Type S3 (STR) Power Management User Define Video Off Method DPMS Video

More information

Express5800/InternetStreamingServer ES ユーザーズガイド

Express5800/InternetStreamingServer ES ユーザーズガイド 5 Press to enter boot selection menu Press to enter SETUP or Press to Netork Press to enter boot selection menu Press to enter SETUP, Service Partition, Netork Press

More information

Express5800/320Lc/320Lc-Rユーザーズガイド(セットアップ編)

Express5800/320Lc/320Lc-Rユーザーズガイド(セットアップ編) 3 B 1 2 Phoenix BIOS S etup Utility Main Advanced Security System Hardare Boot Exit Processor Type : Processor Speed : Cache RAM : System Memory : Extended Memory : Intel (R) Xeon (TM) processor 2.80

More information

環境設定シート

環境設定シート PRIMERGY TX200 S2 環境設定シート 本書の読み方 A コンフィグレーション本サーバにおけるハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX200 S2 Microsoft Windows Server

More information

PRIMERGY RX300 S2(Windows Server 2003 x64 Editions用) 環境設定シート

PRIMERGY RX300 S2(Windows Server 2003 x64 Editions用) 環境設定シート PRIMERGY RX300 S2(Windows Server 2003 x64 Editions 用 ) 環境設定シート 本書の読み方 A コンフィグレーションシートハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入します 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 本文中の表記 PRIMERGY

More information

MF02_BIOS_R00.xls

MF02_BIOS_R00.xls Information Menu ( 情 報 メニュー) Information Menu CPU Type System Memory Extended Memory HDD Serial Number System BIOS Version VGA BIOS Version KBC Version Serial Number Asset Tag Number Product Name Manufacturer

More information

Express5800/R120b-2ユーザーズガイド

Express5800/R120b-2ユーザーズガイド 2 ID 1 2 2 1 2 1 1 2 Press to enter SETUP or Press to boot from Netork Press for SCSISelect(TM) Utility! 1 2 3

More information

PRIMERGY RX300 S4 環境設定シート

PRIMERGY RX300 S4 環境設定シート IntelXeon Intel Corporation 3.5 3.5 1 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB 2 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB 3 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB 4 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB 5 ( ) 73.4 GB

More information

WinPC

WinPC PC 4 6 BIOS PC PC 6 10 14 OS BIOS BIOS Windows 7 18 22 26 Windows Update BIOS 30 BIOS BIOS 30 34 ASUSTeK Computer ASRock 38 42 GIGABYTE TECHNOLOGY MSI 46 46 58 50 54 62 Win7 Ubuntu A B BCD Windows XP bootmgr

More information

C

C (1) (2) Play Volume (3) (4) (5) (6) (7) (8) Ctrl N Ctrl Ctrl (9) (10) OFF (11) (12) OFF (13) (14) 2 3 4 5 6 7 LCD LCD 8 TV ANT. S IN VIDEO IN LINE-L IN LINE-R IN 9 10 11 12 LCD LCD 13 LCD 14 LCD 15 LCD

More information

Express5800/180Rb-7

Express5800/180Rb-7 w w w w Press to enter SETUP or Press Enter password:[ ] Pheonix Phoenix BIOS Setup Utility Main Advanced Security Server Boot Exit BIOS Release : BIOS Version : System Time : System Date : Legacy

More information

PRIMERGY TX100 S3 環境設定シート

PRIMERGY TX100 S3 環境設定シート PRIMERGY TX100 S3 ( 型名 :PYT103 ) CA92344-0072-04 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです

More information

HPCクラスタ専用サーバ  T220Rd-1ユーザーズガイド

HPCクラスタ専用サーバ  T220Rd-1ユーザーズガイド 3 Press DEL run Setup (F4 on Remote Keyboard) Enter CURRENT Passord:[ ] Boot Security Exit USB Configuration Module Version - 2.24.0-11.4 Enables USB host controllers. USB Devices Enabled : 1 Keyboard,

More information

BIOSセットアップメニュー 一覧

BIOSセットアップメニュー 一覧 B6FH-A602-01 Z0-00 ESPRIMO B532/G BIOS セットアップメニュー一覧 各製品名は 各社の商標 または登録商標です 各製品は 各社の著作物です その他のすべての商標は それぞれの所有者に帰属します Copyright FUJITSU LIMITED 2013 BIOS セットアップメニュー詳細 BIOS セットアップのメニューについて説明しています BIOS セットアップのメニューは次のとおりです

More information

US40cユーザーズガイド

US40cユーザーズガイド US40c 1 Enter CURRENT Passord:? _ InsydeH20 Setup Utility Main Advanced Security Boot Exit Video Configuration Poer Save Quick Charge HDD [2GB ATA Flash

More information

FLORA bd500 ユーザーズガイド 500X7

FLORA bd500 ユーザーズガイド 500X7 FB50071000-7 制限 補足 xvii 安全にお使いいただくために 続き 警告ラベルは次に示す箇所に貼り付けられています FLORA bd を取り扱う前に 警告ラベルが貼り付けられていること および警告ラベルの内容をご確認く ださい もし警告ラベルが貼り付けられていなかったり はがれやかすれなどで読みづらかったりする場合 は お買い求め先にご連絡いただくか 保守員をお呼びください

More information

HA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2

HA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2 HB102050A0-4 制限 補足 Esc Enter Esc Enter Esc Enter Main Advanced Server Security Boot Exit A SATA Configuration SATA Controller(s) SATA Mode Selection [Enabled] [RAID] Determines how

More information

4 FT ID 1 0 NMI CPU MEM3 MEM2 MEM1 PSU TMP FAULT I/O FAN2 FAN1 VLT HCS2 HCS1 Phoenix BIOS Setup Utility Main Advanced Security Server Boot Exit System Time: System Date: Processor Settings [14:00:09]

More information

PRIMERGY TX1310 M1 環境設定シート

PRIMERGY TX1310 M1 環境設定シート PRIMERGY TX1310 M1 CA92344-0497-01 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方本文中の製品名称を

More information

PRIMERGY MX130 S2 環境設定シート

PRIMERGY MX130 S2 環境設定シート PRIMERGY MX130 S2 ( 型名 :PYM132 ) CA92344-0090-02 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです

More information

PRIMERGY TX120 環境設定シート

PRIMERGY TX120 環境設定シート PRIMERGY TX120 環境設定シート 本書の読み方 A B C D E F G ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティの設定値を記録しておきます リモートマネジメントコントローラの Web インターフェース設定シートリモートマネジメントコントローラにおける

More information

PRIMERGY TX100 S3 環境設定シート

PRIMERGY TX100 S3 環境設定シート PRIMERGY TX100 S3 ( 型名 :PYT103 ) CA92344-0072-05 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです

More information

Express5800/GT120b ユーザーズガイド

Express5800/GT120b ユーザーズガイド 2 1 2 Press to Run LSI Softare RAID Configuration Utility. Press for Web BIOS Press for SASSelect(TM) Utility! Press to enter SETUP 2

More information

PRIMERGY RX300 S7 環境設定シート ハードウェア編

PRIMERGY RX300 S7 環境設定シート  ハードウェア編 PRIMERGY RX300 S7 CA92344-0147-02 環境設定シート - ハードウェア編 - 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです

More information

PRIMERGY RX200 S4 環境設定シート

PRIMERGY  RX200 S4 環境設定シート IntelXeon Intel Corporation 5 DVD-ROMPG-DV106 5 HDD SAS 3.5SAS HDD 1 2 3.5 ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB ( ) 73.4 GB ( ) 146.8 GB ( ) 300 GB 2.5SAS HDD 1 2 3 4 2.5 ( ) 73.4 GB/10Krpm ( ) 73.4 GB/15Krpm

More information

HP Server tc2120 Microsoft Windows 2000 Server SP3 HP P

HP Server tc2120 Microsoft Windows 2000 Server SP3 HP P HP Server tc2120 Microsoft Windows 2000 ServerSP3 HP P312977-191 200210 Hewlett-Packard Company Hewlett- Packard Company Hewlett-Packard Company Intel Corporation MicrosoftMS-DOSWindows Windows NT Microsoft

More information

PRIMERGY MX130 S2 環境設定シート

PRIMERGY MX130 S2 環境設定シート PRIMERGY MX130 S2 CA92344-0090-03 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C D BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます デザインシート (Windows) ソフトウェアの設定を記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです

More information

RF2_BIOS一覧

RF2_BIOS一覧 Main Main Menu System Time System Date hh:mm:ss( 時 :00~23/ 分 :00~59/ 秒 :00~59) www mm/dd/yyyy ( 曜日 : 自動設定 / 月 :01~12/ 日 :01~31/ 年 :1980~2099) Advanced Internal Pointing Device Enabled Enabled/Disabled

More information

Express5800/R110a-1Hユーザーズガイド

Express5800/R110a-1Hユーザーズガイド 4 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Xeon Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0B60: DIMM group #1 has been disabled. : Press to resume, to

More information

Microsoft Word - DS50-D B_S711_BIOS_Manual.doc

Microsoft Word - DS50-D B_S711_BIOS_Manual.doc BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため

More information

BMC Configuration ユーザーズガイド

BMC Configuration ユーザーズガイド BMC Configuration 1 2 3 4 5 Rev.1.01 NEC Corporation 2011 1 BMC Configuration... 1... 2... 3... 4... 5 1... 6 1.1 BMC Configuration... 6 2... 7 2.1... 7 2.2... 8 3... 9 3.1 BMC Configuration (Windows)...

More information

PC STATION E Series BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認したり 変更するためのプログラムです セットアッププログラムは マザーボード上のフラッシュメモリに格納されているた

PC STATION E Series BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認したり 変更するためのプログラムです セットアッププログラムは マザーボード上のフラッシュメモリに格納されているた PC STATION E Series BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認したり 変更するためのプログラムです セットアッププログラムは マザーボード上のフラッシュメモリに格納されているため いつでも実行できます BIOS セットアッププログラムで定義する設定情報は CMOS RAM と呼ばれる特殊な領域のメモリに格納されています

More information

PRIMERGY TX100 S1 環境設定シート

PRIMERGY  TX100 S1 環境設定シート PRIMERGY TX100 S1 環境設定シート 本書の読み方 A B C D E F ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます システム資源管理表各種拡張カードで選択できる I/O ポートアドレスについて説明しています ディスクアレイ構成設計シートディスクアレイ構成

More information

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS RAID D. RAID/AHCI 2 SATA SSD ( 1) ( ( 3) 2

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS RAID D. RAID/AHCI 2 SATA SSD ( 1) ( ( 3) 2 RAID SATA... 2 RAID/AHCI... 16 Intel Optane... 19 Intel Virtual RAID on CPU Intel VROC... 21 RAID RAID 0 RAID 1 RAID 5 RAID 10 2 2 3 4 * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS

More information

HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル

HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル P1E1M01500-3 - - - LSI MegaRAID SAS-MFI BIOS Version x.xx.xx (Build xxxx xx, xxxx) Copyright (c) xxxx LSI Corporation HA -0 (Bus xx Dev

More information

Microsoft Word - DS50-D A_S501B_BIOS_Manual.doc

Microsoft Word - DS50-D A_S501B_BIOS_Manual.doc BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納されています この設定情報は マザーボードに搭載されているバッテリによって保存されているため

More information

N manual_JP.PDF

N manual_JP.PDF NEC Express5800 - 1 - N8103-73 ESMPRO/ServerManagerServerAgent Power Console Plus Express5800 EXPRESSBUILDER Version 3.077-N(1) Version 3.078a-N 1): - 2 - Windows NT 4.0 Microsoft Windows NT Server 4.0

More information

環境設定シート

環境設定シート PRIMERGY TX0FT S2 環境設定シート 本書の読み方 A コンフィグレーションシート本サーバにおけるハードウェアの構成と各種セットアップのを記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX0FT S2 本文中の表記 本サーバ またはサーバ 商標 インテル

More information

BMC Configuration ユーザーズガイド

BMC Configuration ユーザーズガイド BMC Configuration 1 2 3 4 5 Rev.1.10 NEC Corporation 2012 1 BMC Configuration... 1... 2... 4... 5... 6 1.... 7 1.1 BMC Configuration... 7 2.... 8 2.1... 8 2.2... 9 3.... 10 3.1 BMC Configuration (Windows)...

More information

Mvk-xf6k.pm6

Mvk-xf6k.pm6 1 2 3 MVK-XF6K 25 1 2 26 MVK-XF6K 3 MVK-XF6K 27 1 2 3 4 28 MVK-XF6K 1 2 3 4 MVK-XF6K 29 1 2 30 MVK-XF6K 1 2 MVK-XF6K 31 1 2 32 MVK-XF6K 3 4 MVK-XF6K 33 MEMO STANDARD COMS SETUP BIOS FEATURES SETUP BIOS

More information

本機をお使いの方へ ~『活用ガイド ソフトウェア編』補足ガイド~

本機をお使いの方へ ~『活用ガイド ソフトウェア編』補足ガイド~ MA26D/F MA26H/F Windows 98 ESMPRO 9 1-2-3 98 è / PART1 / 1 Timer-NX OK ê Timer-NX(MA26D/F,MA26H/F Windows98) OK PC98-NX PC-9800 Intellisync 1.60 CD-ROM Intellisync BIOS Peripheral Setup IR Serial Port

More information

N Express5800/R320a-E4 N Express5800/R320a-M4 ユーザーズガイド

N Express5800/R320a-E4  N Express5800/R320a-M4  ユーザーズガイド 7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup

More information

Express5800/R320a-E4, Express5800/R320b-M4ユーザーズガイド

Express5800/R320a-E4, Express5800/R320b-M4ユーザーズガイド 7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup

More information

BMC Configuration ユーザーズガイド

BMC Configuration ユーザーズガイド BMC Configuration 1 2 3 4 5 Rev.1.00N NEC Corporation 2014 1 ... 1... 2... 4... 5... 6 1.... 7 1.1 BMC Configuration... 7 2.... 8 2.1... 8 2.2... 8 2.3... 9 3.... 10 3.1 BMC Configuration (Windows)...

More information

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( (

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( ( RAID RAID 0 RAID 1 RAID 5 RAID 10 2 2 3 4 * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( ( 3) 2 ) Windows USB 1 SATA A. SATA SATA Intel SATA

More information

Express5800/120Mc

Express5800/120Mc Pentium Xeon 1. N8500-436 CPU L1 L2 CD-ROM LAN OS OS (-X/600(256)) N8500-437 N8500-509 N8500-443 N8500-438 N8500-488 (-X /600(256)-25AWS) (-X /600(256)-25AWE) StarOffice Exchange (-X/733(256)) (-X /733(256)-25AWS)

More information

Express5800/120Egユーザーズガイド

Express5800/120Egユーザーズガイド 2 1 1 1 2 2 OUTPUT OUTPUT(SWITCH OUT) UN(SWITCH OUT) AC100V 50/50HZ TOTAL 12.5A Press to enter SETUP Press for SCSISelect(TM) Utility! Press

More information

PAシリーズBIOSマニュアル

PAシリーズBIOSマニュアル ************************************************** KOHJINSHA PA シリーズ BIOS 設定プログラム説明書 ************************************************** --- 注意事項 --- BIOS 設定を間違うと 深刻なトラブルを引き起こすことがあります 内容を変更する際はご注意いただくとともに

More information

環境設定シート

環境設定シート 本シートは PRIMERGY TX150FT S5 を構成する CoServer1(FT1) 用と CoServer2(FT2) 用を作成する必要があります PRIMERGY TX150FT S5 環境設定シート 本書の読み方 A B C D E F G ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます BIOS セットアップユーティリティ設定シート本サーバにおける BIOS

More information

Express5800/320Fc-MR

Express5800/320Fc-MR 7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup

More information

Server Configuration Utility ユーザーズガイド

Server Configuration Utility ユーザーズガイド Server Configuration Utility 1 2 3 4 5 80.109.01-022.01 2016 3 NEC Corporation 2016 1 ... 1... 2... 4... 5... 6 1.... 7 1.1 Server Configuration Utility... 7 2.... 8 2.1... 8 2.2... 8 2.3... 9 3.... 10

More information

Express5800/320Fa-L/320Fa-LR

Express5800/320Fa-L/320Fa-LR 7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup

More information

Server Configuration Utility ユーザーズガイド

Server Configuration Utility ユーザーズガイド Express5800 Server Configuration Utility 1 2 3 4 5 Rev.1.00 NEC Corporation 2014 1 Server Configuration Utility... 1... 2... 4... 5... 6 1.... 7 1.1 Server Configuration Utility... 7 2.... 8 2.1... 8 2.2...

More information

Microsoft Word - DS50-D A_SX505_BIOS_Manual.doc

Microsoft Word - DS50-D A_SX505_BIOS_Manual.doc BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため

More information

Microsoft Word - DS50-D A_E701_BIOS_Manual.doc

Microsoft Word - DS50-D A_E701_BIOS_Manual.doc BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため

More information

Express5800/140Hb (2002/01/22)

Express5800/140Hb (2002/01/22) (2002/01/22) 1. N8100-592B N8100-594B N8100-681 ( -X/700(1)) ( -X/700(2)) ( -X/900(2)) CPU L1 Pentium Xeon (700MHz) 1 4 Pentium Xeon (700MHz) 1 4 32KB Pentium Xeon (900MHz) 1 4 L2 1MB 2MB 2MB CD-ROM LAN

More information

Microsoft Word - DS50-D A_S505A_BIOS_Manual.doc

Microsoft Word - DS50-D A_S505A_BIOS_Manual.doc BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は CMOS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため

More information

Express5800/R320a-E4/Express5800/R320b-M4ユーザーズガイド

Express5800/R320a-E4/Express5800/R320b-M4ユーザーズガイド 7 7 障害箇所の切り分け 万一 障害が発生した場合は ESMPRO/ServerManagerを使って障害の発生箇所を確認し 障害がハー ドウェアによるものかソフトウェアによるものかを判断します 障害発生個所や内容の確認ができたら 故障した部品の交換やシステム復旧などの処置を行います 障害がハードウェア要因によるものかソフトウェア要因によるものかを判断するには E S M P R O / ServerManagerが便利です

More information

PRIMERGY RX200 S2(Windows Server 2003 x64 Editions用) 環境設定シート

PRIMERGY RX200 S2(Windows Server 2003 x64 Editions用) 環境設定シート PRIMERGY RX200 S2(Windows Server 2003 x64 Editions 用 ) 環境設定シート 本書の読み方 A コンフィグレーションシートハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入します 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 本文中の表記 PRIMERGY

More information

Express5800/320Fa-L/320Fa-LR/320Fa-M/320Fa-MR

Express5800/320Fa-L/320Fa-LR/320Fa-M/320Fa-MR 7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup

More information

Express5800/140Ma

Express5800/140Ma Pentium Xeon Express 1. N8500-479 N8500-480 N8500-489,-490 N8500-491,-492 (-X/550(512)-25AWS) (-X/550(1)-25AWS) (-X/550(512)) (-X/550(1)) (-X/550(512)-25AWE) (-X/550(1)-25AWE) CPU L1 Pentium Xeon 550MHz1

More information

PRIMERGY RX600 S6 ご使用上の留意・注意事項

PRIMERGY RX600 S6 ご使用上の留意・注意事項 PRIMERGY RX600 S6 ご使用上の留意 注意事項 PRIMERGY RX600 S6 に関して 以下の留意 注意事項がございます 製品をご使用になる前にお読みくださいますようお願いいたします 2014 年 6 月富士通株式会社 1. メモリボード (PY-MB01/PYBMB01) の注意事項 PRIMERGY RX600 S6 サーバオペレーティングマニュアル の 8.1.5 ホットプラグメモリボード

More information