14 RitsumeikanSocialSciencesReview(Vol52.No.2) PVenergywilbeexamined.Griddatainthe50Hertzzoneisusedinthispartofthestudy.Second,thekey rulesthatenabler

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "14 RitsumeikanSocialSciencesReview(Vol52.No.2) PVenergywilbeexamined.Griddatainthe50Hertzzoneisusedinthispartofthestudy.Second,thekey rulesthatenabler"

Transcription

1 第 52 巻第 WindandPV 2 号 EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) RitsumeikanSocialSciencesReview 2016 年 9 月 13 WindandPVEnergyIntegrationinDistributionGrids andbidirectionalgridoperations: AComparativeAnalysisinJapanandGermany AsamiTAKEHAMA ⅰ Abstract:Gridoperationsandkeyrulesenablingintegrationofwindandphotovoltaicsystemsintothe powernetworksystem injapanandgermanywereanalyzedinthisstudy.theresearchfocuseson reversepowerflowfrom lowvoltage(lv)andmedium voltage(mv)gridstoextra-highvoltage(ehv) grids.theresultsshowedthatgermangridoperatorsflexiblytransmitanddistributeelectricityina bidirectionalway,dependingonthepoweroutputfrom renewableelectricity.germangridoperators prioritizepurchaseofrenewableelectricityandtransmitittotheupstream gridasnecessary.excess electricityfrom windandpvsystemsisphysicalytransmitedtoupstream gridsandtoneighbouring zonesasapriority.injapan,gridoperationisunidirectionalandusesadownwardpowerflowbasedon electricityfrom nuclearpowerandlarge-scalecoalpowerplants.nuclearelectricityhasthefirstpriority overalothertypesofelectricitytobetransmiteddownwardfrom 500kVgridstothelowestvoltage gridsandtointer-zonetie-lines.renewableelectricityhasnolegaldefinitionwithregardtoupstream transmission.becausetherenewableenergyactinjapandoesnotobligeutilitycompaniestoexpand theirgridcapacity,therearefew opportunitiesforrenewableenergysourcesinthegridsystem. Therefore,rulesforupstream transmissionandreinforcementofupstream gridsarerequiredforutility companiesinjapan. Keywords: windenergy,photovoltaicenergy,gridintegration,reversepowerflow,upstream transmission,bi-directionalgridoperation,verticalgridload,prioritytransmission,grid capacitydevelopment Introduction Windandphotovoltaic(PV)energysourcesareusefulwaystoreduceCO2emissionsintheelectricity sector.however,distributiongridsystemsarefacingchalengesofhow besttoaccommodatewindandpv energyonalargescalebecausemiddleandlow voltagedistributiongridswerenotoriginalydesignedfor thispurpose.inthisstudy,gridoperationsinjapanandgermanyareinvestigated,withafocusonkeyrules thatenablewindandpvsystemstobeintegratedintothepowernetworkonalargescalebycomparing energypoliciesinthetwocountries. First,bidirectionalgridoperationinthe50HertztransmissionzoneinGermanyisexamined.This researchfocusesonreversepowerflow (Rückspeisung)from low voltage(lv)andmedium voltage(mv) gridstohighvoltage(hv)grids.therelationshipbetweenreversepowerflow andfeed-infrom windand ⅰ Professor,FacultyofSocialSciences,RitsumeikanUniversity

2 14 RitsumeikanSocialSciencesReview(Vol52.No.2) PVenergywilbeexamined.Griddatainthe50Hertzzoneisusedinthispartofthestudy.Second,thekey rulesthatenablereversepowerflow from windandpvenergyingermanywilbediscussed,including rulesconcerninggridconnection,transmissionandupstream transmissionofrenewableelectricityunderthe ErneuerbareEnergienGesetz(EEG:RenewableEnergySourcesAct) 1,2.Finaly,rulesconcerning connection,transmission,distributionandgridexpansionunderthefeed-intariflaw injapanwilbe analyzed.thereformsnecessaryforthesuccessofthislaw wilbediscussedthroughacomparisonwith gridintegrationpoliciesingermany. 1 GridoperationwithhighpenetrationofwindandPVenergyinGermany 1.1 Negativeverticalgridloadandreversepowerflow Apositiveverticalgridload(VGL)indicatesloadflowfrom the380kvtransmissiongridtothe110kv distributiongridwithavoltagedecreasethroughtransformers,whereasanegativevglindicatesreverse powerflow from the110kvgridtothe380kvgridwithavoltageincreasethroughtransformers. 3 The valueofvglinthisstudyisdefinedasthetotalnetsum ofelectricitythroughaltransformersandtie-lines thataredirectlyconnectedtothe380kvgridinthecontrolzoneofeachtransmissionsystem operator (TSO).Reversepowerflow can occurin sometransformersubstationswith alargecapacityof interconnectedwindandpvsystems,whilesomeurbanorindustrialareashaveapositivevglatthesame time.eveniftheaggregatedvglinatso controlzoneisnegative,thereisapossibilitythattransformer substationsinsomeareaswilstilhaveapositivevgl.vglsaregiveninunitsofmw/15min. 4 Inthispaper,VGL,tie-linetransmission,andinternationaltransmissioninthe50HertzandTenneT zoneswilbeexaminedusinggriddatainunitsof15min,withtherelationshipbetweenfeed-infrom wind andpvenergyasapriority.inthe50hertzzone,windenergycapacityisaround13,4000mw andpv capacityis7,400mw.dataforcontrolareaload,vgl,windfeed-in,pvfeed-in,internationalexchange,and feed-inmanagementareshowninunitsofmw/15min,accordingtosections13(1)-enwg and13(2)-enwg (GermanEnergyIndustryAct).Thegridloadforeachtransmissionlineinthe50Hertzzoneisshownin MW/hour.Aldataareavailableatthewebsiteof50HertzGmbH VerticalgridloadandvoltagelevelsofwindandPVenergyintegration ThemagnitudeandtimesofthenegativeVGLhaveincreasedsince2011inthe50Hertzzone(Fig.1). TheamountofnegativeVGLaccountedfor0.68%ofthetotalsum ofelectricitytransmitedbetweenthe380 kvgridand110kvgrid,andhoursofnegativevglaccountedfor3%ofannualhoursin2013.browncoal, largehydro,andhardcoalplantsareconnectedtothe380kvtransmissiongridsinthe50hertzzone. However,91%ofwindcapacityandalmostalPVcapacityinthe50Hertzzoneisinterconnectedtothe 110kVandlowervoltagegrid(Fig.2).Around76%ofPVcapacityinthe50Hertzzoneisconnectedtothe MVgrid,whichindicatesthatfeed-infrom windandpvenergysatisfiestheloaddemandinthelvandmv grids. TheEEG obligesgermangridoperatorstofeed-inandtrasnmitelectricityfrom renewableenergy sources(res)asapriority.therefore,whenfeed-infrom RESexceedstheloaddemandintheLV(0.23or 0.4kV)andMV(20or35kV)grids,theexcesselectricityistransmitedtotheHV grid(110kv)witha voltageincrease.whenfeed-infrom windandpvenergyexceedstheloadinthe110kvgrid,excess electricityistransmitedtothe380kvgridwithavoltageincrease. The380kV/110kV transformersareequippedwithon-loadtapchangersthatcancontrolvoltage

3 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 15 Fig.1.Verticalload(50Hertzzone,Jan.2011 Oct.2014) changescausedbyreversepowerflow.inaddition,almostaltransformersat380kv/110kv,hv/mvand MV/LVareequippedwithboth-directionprotectionsystemstodealwithreversepowerflow.Both-direction protectionsystemshavebeeninstaledinthepastdecade. 6 ThisisbecausetheEEG (2004version)obliged Germangridoperatorstotransmitrenewableenergyelectricityasapriority.Reversepowerflow at 380kV/110kVtransformersoccursonlywhenwindandPVfeed-inisextremelyhighandthecontrolarea loadislow.athv/mv andmv/lv transformers,however,reversepowerflow occursquiteoftenin distributionareasinwhichalargecapacityofwindandpvsystemsareinterconnectedtothegridandthe loadinthedistributionareaislow. 7 Fig.2.Integratedvoltagelevelsofrenewables (50Hertz,Oct.2014) Source:Calculatedfrom EEG-Anlagenstammdaten Correlationofwindfeed-in,PVfeed-inandreversepowerflow Feed-infrom windandpv systemscanvaryaccordingtoweatherconditions.however,theeeg requiresgridoperatorstofeed-inelectricityfrom windandpvsystemsasapriority.therefore,tsosmust

4 16 RitsumeikanSocialSciencesReview(Vol52.No.2) ensuresystem stabilityandreliabilityofthegrid,andmustadapttochangesofwindandpvfeed-inatthe sametime.residualload(rl)indicatesifwindandpvelectricityisfed-intothegridasapriority,andwhat amountofthecontrolarealoadmustbesatisfiedwithfeed-infrom conventionalpowerplantsandother renewablepowerplants. RL=L (W +PV) (1) TheRLisdefinedinEquation(1),whereListheloadinthecontrolzone[MW].W isthewindfeed-in, andpvisthephotovoltaicfeed-in[mw].highfeed-infrom windandpvenergyandalowloadinacontrol areacausesalowornegativeresidualloadandalowornegativevgl(figs.3,4,5).vglclearlydecreases Fig.3.Verticalgridloadandhighfeed-infrom windenergy (20 28Dec.2013,50Hertzzone) Fig.4.Verticalgridload,exportandtransmissiontotheTenneTzone (20 29Dec.2013,50Hertzzone)

5 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 17 Fig.5.GridsituationofhighwindandPVfeed-in,lowload,verticalload and curtailmentaccordingtosection 13(2)-EnWG (German EnergyIndestryAct)(22 28March,2013,50Hertzzone). Fig.6.ResidualloadandVGL (50Hertzzone,2013) Fig.7.Windfeed-inandVL (50Hertzzone,2013) atatimeoflowresidualload.thisisbecauseasfeed-infrom windandpvenergyinthedistributiongrid (LV,MV.110kV)satisfiestheloadineachgrid,feed-infrom the380kv to110kv griddecreases. Electricitysuppliedtothe380kVgridismainlyfrom browncoal,hardcoal,andlargehydropowerplantsin the50hertzzone.thereisnonuclearpowerplantinthiszone.thereisaclearcorrelationoftheresidual loadandvglinthe50hertzzone(fig.6).whenwindfeed-inishigh,vgldereases,andtheamountof windfeed-inmainlydeterminesthevglinthe50hertzzone(fig.7). 1.4 Reversepowerflow anduseofdomestictie-linetransmission AtatimeofveryhighwindandPVfeed-in,theVGLinthe50Hertzzonebecomesnegativeatalmost

6 18 RitsumeikanSocialSciencesReview(Vol52.No.2) al380kv/110kv transformersubstations,exceptinlargecitiessuchasberlinandhamburg.excess electricityinthe110kvgridistransmitedtotheupstream 380kVgridasreversepowerflow andtothe neighbouringtennetzoneandinternationalzones(denmark,poland,andczechrepublic).thecapacity fordomestictie-linetrasnmissionfrom the50hertzzonetothetennetzonetotalsaround5000mw under stableconditions. 9 Ontheotherhand,thecapacityalocationforcross-bordercongestionmanagementin the50hertzzoneisaround2000mw (from 50Hertz)withfourcross-borderconnectionhubs. Theamountofdomestictie-linetransmissionfrom the50hertzzonetothetennetzoneisestimated usingequation(2). Tr-TenneT=(G L) Exp (2) wheretr-tennetisthetransmissionfrom the50hertzzonetothetennetzone[mw],g isthegenerated amountinthecontrolzone,listhecontrolareaload[mw],andexpisthenetexportfrom thecontrol zone[mw]. Correlationsofwindfeed-inwithdomestictie-linetransmissionfrom the50hertzzonetothetennet zone(fig.8)andwithnetexport(fig.9)aresimilar.theamountofdomestictie-linetrasnmissionreached itsmaximum limitofcapacity(fig.8)andthenetexportreacheditsmaximum trasnmissionlimit(fig.9). Fig.8.Windfeed-inandtransmissionto TenneTzone (Oct. Dec.2013,50Hertzzone) Fig.9.Windfeed-inandnetexportinthe (50Hertzzone,2013) 1.5 Tie-linetransmissiontotheTenneTzoneandwindfeed-in Inahighwindfeed-insituation,50Hertztransmissionusesthefolowingthreeroutestotransport excesselectricityfrom windenergytothetennetzone:(a)no.413,no.414(remptendorf-redwiz),(b) No.449(Vieselbach-Mecklar),No.450(Eisenach-Mecklar),and(c)No.491,No.492(Wolmirstedt- Helmstedt).Thisisbecausealargecapacityofthewindenergysystemsislocatedinnorthernareasinthe 50Hertzzone. ThegridloadsoftransmissionlinesatNo.413,No.414,No.449,andNo.450between50Hertzand TenneTareshowninFigs.10(a)and10(b).WindandPVfeed-inandTSO interventionforsystem security

7 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 19 undersection13(1)-enwg and13(2)-enwg (GermanEnergyIndustryAct)andSection11-EEG areshown infig.10(c).theamountofpowerregulatedundersection13(1)-enwg mainlycorrespondstoredispatch from conventionalpowerplants.theamountofpowerregulatedundersection13(2)-enwg inconjunction withsection11-eeg ismainlycurtailment(feed-inmanagement)ofreselectricity. ThesolidanddotedlinesinFig.10(a-c)show 50%and70%capacityuse,whichmeansthegridloads were50%and70%ofthetransmissioncapacityofeachline,respectively.a provisoisthatthereal transmissioncapacitycanvaryaccordingtoreal-timegridsituations.thelinesfor50%and70%capacityuse inthispaperonlyindicatetheminimum value[mw]foreachlineintheyear2012.accordingtoan explanationgivenby50hertztransmission,griduseatlessthan50%capacityhasnoproblemsinacaseof linefailure.however,acapacity 50%to 70%isclosetothelimitiflinefailureoccurs.Ifthecapacityuse is>70%,itisatthelimitinacaseoflinefailure. 10 The50HertzzoneintegratesalargecapacityofwindandPVenergy,inadditionto10GW forbrown coalplants.therefore,the50hertzzoneoftenhasexcesselectricitytransmissiontothetennetzoneandto cross-bordertransmission,exceptatatimeofverylowwindfeed-in,althoughthegridloadinfig.10does notindicatethedirectionofelectricityflowfrom ortothe50hertzzone. (a) (b) (c) Fig.10.Gridloadofdomestictie-linesbetween50HertzandTenneTinDec.2012bylineinhourly values. (a)lineno.449,no.450,(b)lineno.413,no.414,(c)windandpvfeed-inandtso interventionsforsystem security(redispatchandcurtailmentsunders.13(1)and13(2)enwg (EnergyIndustryAct).

8 20 RitsumeikanSocialSciencesReview(Vol52.No.2) Fig.11.Gridloadofinter-zonetransmissionlines,No.413andNo.414,sortedin orderofgridloads(marchtodec.2012,50hertzzone). Source:Calculatedfrom datafor50hertzgridloadflowbyline ThegridloadatNo.413,No.414,No.449andNo.450oftenreached50%ofthetransmissioncapacity. ThegridloadofNo.413exceeded50%capacityusein1663hoursandNo.414in1620hoursof7336 observedhoursfrom 1 st Marchto31 st Dec.2012(Fig.11).BasedonFigs.8,10and11,50Hertz Transmissionusesdomestictie-linestothemaximum limittotransmitexcesselectricityfrom windandpv energy. 1.6 Bidirectionalgridopertationstofeed-inrenewableelectricityinGermany AlargenegativeVGLinthe50Hertzzoneiscausedbycombinedefectsoffeed-infrom windandpv energy(fig.12).highlevelcapacityuseindomestictie-linesbetween50hertzandtennetsignifiesthat 50Hertztransmissionsystem operatorsusedomestictie-linesfulytotransmitexcesselectricityfrom wind andpvenergyasapriority(fig.11).reversepowerflowoccursquiteoftenfrom LVtoMVgridsandfrom Fig.12.Negativeverticalgridload,windandPVfeed-ininthe50Hertzzone(5th 12thMay2014)

9 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 21 Fig.13.Reverse powerflow from middle volatage to high voltagegrids(energienetzmitezone,measuredat HV/MVtransformersubstations,2013) Source:Calculatedfrom datafrom EnergieNetzMite Fig.14.Reversepowerflow from renewableenergyplantsandvoltagelevels Source:BasedoninterviewswithTSOsandDSOs

10 22 RitsumeikanSocialSciencesReview(Vol52.No.2) MVtoHVgrids(Fig.13).However,veryfew distributiongridoperators(dsos)disclosetheirreverse powerflow(rückspeisung)datainmvgrids(20kv)orlvgrids(230vand400v). ThesedatasuggestthatGermangridoperatorscarryoutbidirectionalandflexiblegridoperationsto feed-inandtransmitrenewableenergyelectricitytoupstream gridsasapriority,ifnecessary. 11 Asimplified structureofbidirectionalgridoperationandintegratedvoltagelevelsofrenewableenergyplantsingermany isshowninfig.14.thisfigureisbasedonseveralinterviewswithdsosandtsos. 2 GridintegrationrulestoenablebidirectionalgridoperationsinGermany Thekeyrulesforgridconnection,purchaseandtransmissionofrenewableelectricityandbidirectional gridoperationsundertheeeg (2014version)aresummarizedinthissection.TheEEG requiresgerman gridoperatorstoimmediatelyandevenphysicaly,asapriority,purchase,transmitanddistributealofthe electricityproducedfrom renewableenergysourcesorfrom minegas(section11(1)-eeg).thedutiesof prioritypurchase,transmissionanddistributionareimposedongridoperatorswhoaredirectlyconnectedto renewablepowerplantsandonupstream TSOsconnectedwithrenewableplantsindirectly(section11(5)1- EEG).Thesedefinitionsrequireupstream TSOstotransmitelectricityfrom renewableenergyphysicalyas apriority.thisenablesreversepowerflow ofexcesselectricityfrom renewableenergyfrom thelower voltagegridtothehighervoltagegrid. TheEEG requiresthatgermangridoperatorsimmediatelyoptimize,reinforceandexpandtheir networkswiththeavailabletechnologytoensurepurchase,transmissionanddistributionofelectricityfrom renewableenergy(section12(1)-eeg).thedutyofgridreinforcementisevenimposedonupstream grid operatorsuptoavoltagelevelof110kv,evenifrenewablepowerplantsarenotdirectlyconnectedwith them (section12(1)-eeg).gridoperatorsareobligedtoprovidegridconnectionstorenewablepower plants,evenwhenpurchaseofrenewableelectricityisonlypossiblebyoptimizing,reinforcingand expandingthegrid(section8(4)-eeg). Itshouldbenotedthat,accordingtotheEEG,evenupstream gridoperatorsareobligedtocarryout gridreinforcement.hostingcapacityincreaseandoptimizationofvoltagecontrolinthedistributiongrid (LV,MVand110kVgrids)areessentialtoenablereversepowerflow from windandpvfeed-ininlower voltagegrids.thisisbecausereversepowerflow from excesselectricityfrom windandpvsystemsoften causesvoltagerisesindistributiongridsandtransformers,especialyatmv/lvandhv/mvtransformers inlocaldistributiongrids. 12 Therefore,thismandatorycapacityexpansionimposedongridoperators, includingupstream grids,isimportanttoachievereversepowerflowfrom windandpvenergysystemsin distributiongrids. Theoperatorcanbringthecompensationcostforfeed-inmanagement(curtailment)intothecalculation ofgridcharges.however,thegridoperatorbearsthecompensationcostsoffeed-inmanagement,ifthe operatordidnotexhaustaloptionsforoptimizing,reinforcing,andexpandingthegrid(section15(2)-eeg). ThesestrictlegaldefinitionsmakeGermangridoperatorsreinforcethegridsystem toensurepurchaseand transmissionofrenewableelectricity.thesedefinitionsarethelegalbasisofenablingreversepowerflowof renewableelectricityandbidirectionalgridoperationsingermany. 3 GridintegrationpoliciesforwindandPVenergyinJapan Thestructureofthepowersystem injapanandgridintegrationpoliciesforwindandpvenergies

11 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 23 undertheactonspecialmeasuresconcerningprocurementofelectricityfrom RenewableEnergySources byelectricityutilities(hereinafter,therenewableenergyact)aresummarizedinthissection. First,itshouldbenotedthatinJapanthetransmissiongridsystemshaveyettobeseparatedfrom generationbusinesses.theninemajorgenerationcompanies(generalutilitycompanies;hereinafter,the utilitycompanies)ownandoperatethegridsystemsintheircontrolzones.theseninecompaniesare verticalyintegrated powercompaniesthatoperatealaspectsfrom generation,transmissionand distributiontoretailofelectricity(fig.15).theseutilitycompaniesown90%ofthetotalgenerationcapacity injapan,includingnuclearpowerplants(fig.16). Therearenolegaldefinitionsconcerningpriorityconnectionandpurchaseofrenewableelectricity undertherenewableenergyact.thereisaprovisothatwhenthereisarisktostablesupplyandgrid reliability,theutilitycompaniescanrejectaconnectionrequestfrom renewableoperators(article5, paragraph1,(2)-renewableenergyact).sixofthenineutilitycompaniessetacapacityrestrictiononpv andwindenergyintegrationineachcontrolzone(figs.17and18).therearenolegaldefinitionsofthe priorityconnection and prioritytransmission ofrenewableelectricityundertheact.thesixutility companiesinfig.18arealowedtosetcurtailment(outputreduction) withoutcompensation topv operatorswhenintegrationofpvcapacityineachcontrolzoneexceedstherestrictionamount(article6, paragraph7.enforcementregulationsintherenewableenergyact). 13 TheRenewableEnergyActdoesnotobligateutilitycompaniestoexpandandreinforcethegridsystem toaccommodaterenewableenergyplants.toincreaseintegrationofwindandpvsystems,suitablecapacity expansionandreinforcementoflow voltagegrids(0.2kv),6.6kvgridsand66kvgridsareurgently needed,forthefolowingreasons.thevoltagelevelsinthejapanesegridsystem are500,275,154,66,22 and6.6kvand100and200v(withsomeregionalvariationsincontrolzones).theinter-zonetie-linesare mainlyat500kv grids.nuclearandlargefossilfuelplantsareconnectedto500kv grids.hardcoal generatorsandlargehydropowergeneratorsareconnectedto500kv,275kvor154kvgrids.incontrast, manywindenergysystemsareinterconnectedwith66kvor154kvgrids.manypvsystemsareconnected tolow voltage,6.6kvand66kvgrids.therefore,toaccomodatewindandpvsystems,itisnecessaryto expandandreinforcelowvoltage(0.2kv),6.6kv,66kvand154kvgrids. WhenwindandPVsystemsareintegratedintothegridonalargescaleandinaperiodofhighfeed-in from windandpvenergies,excesselectricityineachtrasnformersubstationwilcausereversepowerflow. Thisflow wilcausevoltageincreasesattransformersanddistributiongrids,especialyinthelow voltage and6.6kvgrids.therefore,bothgridcapacityandtransformercapacitymustbesuficientlyexpandedand reinforced.both-directionprotectionssystemsandvoltagecontrolequipmentmustbeoptimizedtoenable reversepowerflow andupstream trasnmissionwithcontrolofvoltagelevelsinapermissiblerange.in addition,theregulatoryframeworkinjapanrequiresutilitycompaniestobeobligedtoexpandandreinforce theirgridsattheirownexpense,includingupstream voltagegridssuchasthe66kvand154kvgrids,ifit isindeednecessarytoaccomodatetherenewableenergyplants. Toenablereversepowerflow attransformersubstationsinthe6.6kvand66kvgrids,upstream transmissionisessential.however,therenewableenergyactdoesnotobligetheutilitycompaniesto prioritizetransmissionofrenewableelectricitytoupstream grids. WindandPVsystem operatorsarestrictlylimitedconcerninguseofinter-zonetie-linesundertherules ofoccto (OrganizationforCross-regionalCoordinationofTransmissionOperators,Japan).Renewable energyoperatorsarerequiredtousebateries,electricitystoragemeasuresorcombinationofother electricitysourcestostabilizefeed-infrom windandpvsystems 14.

12 24 RitsumeikanSocialSciencesReview(Vol52.No.2) Fig.15.Gridstructureandinter-zonetielinesinJapan Source:Sammarizedfrom theinterim ReportoftheCommiteeontheMasterPlanforReinforcementofInter- ZoneTie-Lines(PowerSystem Reform Commitee,MinistryofEconomy,TradeandIndustry),2012.Looddata basedonthefederationofelectricpowercompaniesofjapan. Fig.16.GenerationcapacityinJapanin2004and2014 Source:Calculatedfrom powergenerationstatisticsfrom METI,feed-intarif schemedatadisclosurefrom METI,andTrendsinPhotovoltaicApplicationsfrom IEA-PVPS Inatimeofcurtailment(suppressionofoutputfrom generators),renewableelectricityhasapriority onlyoverfossilfuelplants.however,nuclearelectricityalwayshasthefirstpriorityoveralotherelectricity tofeed-intotrasnmissiongridsineachzone(undertherenewableenergyact) 15 andtointer-zonetie-lines (undertheoccto NetworkCode).Thiscodestatesthat long-term costrecoverygeneration hasthefirst priorityintransmissiontointer-zonelines.thenetworkcodedefinesnuclearenergyas long-term cost recoverygeneration. 16

13 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 25 Fig.17.Capacityrestrictionsonwindenergyintegrationbymajorutility companies Source:Datafrom METINew EnergySubcommitee,FederationofElectricPower CompaniesJapan. Fig.18.CapacityrestrictionsonPV energyintegration,requestsfor connection,andinstaledcapacity Source:Datafrom METINew EnergySubcommitee,FederationofElectricPower CompaniesJapan. AccordingtotheImplementingRegulationsintheRenewableEnergyAct(hereinafter Implementing Regulations ),whenfeed-infrom renewableenergygeneratorsexceedsdemandineachcontrolzone,utility companiescanimposecurtailments(suppression)ofoutputonrenewableelectricity.utilitycompaniescan escapefrom paymentofcompensationforcurtailmentforupto360hoursayearforpvsystemsand720 hoursayearforwindenergysystems. 17 Inaddition,theregulationexemptsthefolowing designatedutility companies from thepaymentofcompensationwithoutlimitationofhours:hokkaido,tohoku,hokuriku, Shikoku,ChugokuandKyushuutilitycompaniesforPV systems,andhokkaidoandtohokuutility

14 26 RitsumeikanSocialSciencesReview(Vol52.No.2) companiesforwindenergysystems Conclusions: BidirectionalgridoperationinGermany,unidirectionalgridoperationinJapan GriddatainGermanyshow thatgermangridoperatorsflexiblytransmitanddistributeelectricityina bidirectionalway,dependingonthepoweroutputfrom renewableelectricity.gridoperatorsprioritize purchaseofrenewableelectricityandtransmitittotheupstream gridasnecessary.excesselectricityfrom windandpvsystemsisevenphysicalytransmitedtotheupstream gridandtoneighboringzonesasa priority.germanrenewableenergylaw obligatesgridoperatorstoexpandanddevelopgridcapacity withoutdelay toaccommodaterenewableelectricity.thislegalframeworkhasenabledbidirectionalgrid operations. Incontrast,gridoperationinJapanisunidirectionalandhasadownwardpowerflow basedonsupply from nuclearpowerandlarge-scalecoalpowerplants.nuclearelectricityhasthefirstpriorityoveralother typesofelectricitytobetransmiteddownwardfrom 500kVgridstolowestvoltagegridsandinter-zonetie lines.theutilitycompaniesgiverenewableenergysystemsverylimitedaccesstothegrid,andrenewable electricityhasnolegaldefinitioninregardtoupstream transmission.becausetherenewableenergyactin Japandoesnotobligeutilitycompaniestoexpandtheirgridcapacity,therearefew opportunitiesfor renewableenergysourcestopenetrateintothegridsystem injapan. ThefolowingreformsarenecessaryingridintegrationpoliciesforwindandPVenergyonalarge scaleinjapan.first,generationbusinessesmustbelegalyseparatedfrom gridoperationbusinesses(not onlyoperationofinter-zonetielines,butalsotransmissionanddistributiongridsineachzone).second, utilitycompaniesmustbeobligedtoconnectrenewableenergysourcestothegridasapriorityoveral otherenergysources.aslongasnuclearpowerplantssupplybasepowerasthefirstpriority,windandpv electricitycannotpenetrateintotheelectricitysupplyonalargescale.third,utilitycompaniesmustbe obligedtoexpandandreinforcetheirgrids,includingupstream gridsystems,inareasonableperiodoftime toensurepurchaseofrenewableelectricity,evenifgridexpansionandreinforcementarenecessarytobuild anew connectionwitharenewablepowerplant.inparticular,gridexpansionandreinforcementfor6.6kv, 66kVand154kVgridsareessentialtoensurewindandPVenergyintegration.Fourth,utilitycompanies mustbeobligedtotransmitelectricityfrom renewablestoupstream gridsphysicalyasapriorityifthisis necessary.rulesforupstream transmissionandgridreinforcementofupstream gridsmustbejointly imposedonutilitycompanies.capacityexpansionofgridsisimportantforutilitycompanies,bothtoenable reversepowerflow from excesselectricityoflowervoltagegrids,andtocontrolvoltagelevelsina permissiblerangeaccordingtogridtechnicalcodes.capacityexpansionisurgentlyneededforlower voltagegridswithwhichrenewableenergiesareinterconnected,andforupstream grids.fifth,thecapacity restrictionongridintegrationofpvandwindenergymustbeabolished.sixth,compensationmustbepaid forrenewableenergyoperatorswhencurtailmentissetonrenewableelectricityineachzone. Acknowledgment ThisworkwassupportedbyJSPSKAKENHIGrantNumber andbytheSocietyofRitsumeikan SocialSciences.

15 WindandPV EnergyIntegrationinDistributionGridsandBidirectionalGridOperations(AsamiTAKEHAMA) 27 Notes 1 GesetzfürdenAusbauerneuerbarerEnergien(Erneuerbare-Energien-Gesetz-EEG,2014). 2 GesetzfürdenVorrangErneuerbarerEnergien(Erneuerbare-Energien-Gesetz-EEG,2012). 3 ThevoltagelevelsintheGermanpowersystem aresuperhighvoltage(shv)fortransmissiongridsat380kv or220kv,highvoltage(hv)fordistributiongridsat110kv,medium voltage(mv)forlocaldistributiongrids at20kv(and35kvinsomeregions,sincethereareregionaldiferencesinmvlevels),andlowvoltage(lv) forlocaldistributiongridsat400vand230v,mainlyforsmal-scaleconsumers. 4 50Hertz:Verticalgridload.availablefrom htp:// 5 Datausedinthisstudy:(a)50Hertzzonein2013:Generationouput,Verticalgridload,Controlareaload, Windfeed-in,PVfeed-in,Maßnahmennach 13.1EnWG, 13.2EnWG,Loadflowscross-border,inMW/15 min.(b)50hertzzone:gridloadbyline,hourlydatainmw. 6 BasedoninterviewswithFraunfoherIWES(inAug.2015),HanseWerke(inMay.2014),StromnetzHamburg (insep.2015),50hertz,andamprion(insep.2014). 7 Stetz,T.,Kraiczy,M.,et.al.Technicalandeconomicalassessmentofvoltagecontrolstrategiesindistribution grids.prog.photovolt.res.appl.(2013),doi: /pip HertzGmbH:availablefrom htp:// 9 Informationfrom 50HertzGmbH.Actualtransmissioncapacitycanchangeaccordingtogridconditions Hertz:Explanationongridloadandcapacityusage:htp:// 11 Stetz,T.,Kraiczy,M.Diwold,K.etal.Transitionfrom unidirectionaltobidirectionaldistributiongrids.iea- PVPS,task14(2014). 12 ConcerningthevoltagerisecausedbyhighPVpenetrationinthelocaldistributiongrid,thenecessarygrid expansionmeasuresareexplainedinthefolowingpapers:stetz,t.,kraiczy,m.diwold,k.country-specific analysis,germany.iea-pvpstask14,subtask2:highpenetrationsofphotovoltaicsystemsindistribution Grids(2014).Stetz,T.,KraiczyM.,et.al.,Technicalandeconomicalassessmentofvoltagecontrolstrategiesin distributiongrids.prog.photovolt.res.appl.(2013),doi: /pip Concerning thedesignated UtilityCompaniesshown in Fig.18and theokinawapowercompany. ImplementingRegulationsfortheActonSpecialMeasuresConcerningProcurementofElectricityfrom RenewableEnergySourcesbyElectnicityUtilities. 14 OCCTO:NetworkCodesoftheOrganizationforCross-regionalCoordinationofTransmissionOperators, Japan.Article202,Paragraph3-(i),(amendedApril2016). 15 ImplementingRegulationsfortheActonSpecialMeasuresConcerningProcurementofElectricityfrom RenewableEnergySourcesbyElectricityUtilities.Article6,Paragraph1,Point3-(1). 16 OCCTO,NetworkCodesoftheOrganizationforCross-RegionalCoordinationofTransmissionOperators, Japan.Article202,Paragraph1-(vi),(vi),Article210,Paragraph1(amendedApril2016). 17 ImplementingRegulationsfortheActonSpecialMeasuresConcerningProcurementofElectricityfrom RenewableEnergySourcesbyElectricityUtilities.Article6,Paragraph1,Point3-(1). 18 ImplementingRegulations.Article6,Paragraph1,Point7.

16 28 RitsumeikanSocialSciencesReview(Vol52.No.2) 風力 太陽光発電の配電網への系統連系, 双方向潮流対応の系統運用について 日本とドイツの比較分析 竹濱朝美 ⅰ 本稿は, 風力 太陽光発電システムを配電網に大量連系するための規則と系統運用について, 日本とドイツを比較した 特に, 配電網から送電網への逆潮流に焦点を当てて分析した ドイツでは, 系統運用者 ( 送電会社および配電会社 ) は, 風力 太陽光発電からの電力を, 出力状況に応じて柔軟に, 低圧および中圧系統から高圧系統へ, さらには, 特別高圧系統に逆潮流させる双方向潮流対応の系統運用を行っている ドイツの系統運用者は, 再生可能エネルギー電力を最優先で給電し, かつ, 上位電圧系統に優先送電する義務を負う 系統運用者は, 風力 太陽光発電からの給電が配電網内の需要を上回る場合, 上位電圧系統 ( 送電網 ) に, 物理的にも電力を上流送電し, 他の送電区域に地域間送電する これに対して日本では, 長期固定電源 ( 原子力, 大型水力, 地熱発電 ) の電力を500kV 送電系統から低圧系統に, 下方一方向潮流で配電する系統運用である 日本では, 原子力発電からの電力を他の全ての電源に優先して, 給電 配電する 地域間送電線の使用においても, 日本では, 原子力発電の電力を最優先で送電する規則となっている 日本では, 再生可能エネルギーからの電力を, 下位電圧系統から上位電圧系統へ優先的に上流送電 ( 逆潮流 ) させる規則は整備されてない 日本の再エネ特措法は, 一般電気事業者に電力網の系統容量の拡張を義務付けていないため, 系統容量の拡張が不十分なままで, 再生可能エネルギー電源の連系を制約している 再生可能エネルギー電源を大量に電力網に連系させるには, 一般電気事業者に対して, 再生可能エネルギー電力の上流送電と電力網の系統増強を義務付ける必要がある キーワード : 風力発電, 太陽光発電, 系統連系, 逆潮流, 上流送電, 双方向潮流対応, 垂直負荷, 優先送電, 系統増強 ⅰ 立命館大学産業社会学部教授

Microsoft Word 給電データ開示_竹濱bウエブ開示用 docx

Microsoft Word 給電データ開示_竹濱bウエブ開示用 docx 特集 : 風力発電と電力系統との融和ドイツにおける風力発電の給電データ開示制度と系統運用の現状立命館大学産業社会学部教授竹濱朝美 はじめに本報告は ドイツにおける再生可能エネルギー電源の給電データ (grid data) 開示制度 風力発電と太陽光発電を含めた需給運用の現状を紹介する ( 以下 再生可能エネルギー電源は再エネ 固定価格買取制度は買取制度と略す ) 今回は 50Hertz 送電区域の給電データをもとに系統運用の現状を要約する

More information

. 石垣島における電力系統の概要 Copyright The Okinawa Electric Power Company, Incorporated. All Rights Reserved.

. 石垣島における電力系統の概要 Copyright The Okinawa Electric Power Company, Incorporated. All Rights Reserved. 石垣島における再生可能エネルギー発電設備の連系に関する説明会 平成 6 年 6 月 3 日 沖縄電力株式会社 . 石垣島における電力系統の概要 Copyright The Okinawa Electric Power Company, Incorporated. All Rights Reserved. . 石垣島系統における電源設備 石垣島では主に内燃力発電機を用い電気の供給を行っております 内燃力発電設備

More information

NISSIN REPORT 2015 17 18 19 20 21 22 23 1 2 3 5 7 9 10 11 12 13 15 1,500 1,000 500 0 1,033 2012 1,099 1,071 2013 2014 150 100 50 0 71 2012 95 90 2013 2014 44.2% 18.3% 22.4% 15.1% 49.5% 1.1% 28.4% 17.5%

More information

内の他の国を見てみよう 他の国の発電の特徴は何だろうか ロシアでは火力発電が カナダでは水力発電が フランスでは原子力発電が多い それぞれの国の特徴を簡単に説明 いったいどうして日本では火力発電がさかんなのだろうか 水力発電の特徴は何だろうか 水力発電所はどこに位置しているだろうか ダムを作り 水を

内の他の国を見てみよう 他の国の発電の特徴は何だろうか ロシアでは火力発電が カナダでは水力発電が フランスでは原子力発電が多い それぞれの国の特徴を簡単に説明 いったいどうして日本では火力発電がさかんなのだろうか 水力発電の特徴は何だろうか 水力発電所はどこに位置しているだろうか ダムを作り 水を 中学第 1 学年社会科 ( 地理的分野 ) 学習指導案単元名 : 日本の資源 エネルギー問題 授業者 : 教育学部第二類社会系コース学生番号 :B130301 氏名 : 池田葵 本時の学習 ⑴ 本時の目標 日本は資源に乏しく 国内で使用されている資源のほとんどを海外からの輸入に頼っていることを理解する 日本では現在火力発電が発電のほとんどを占めているが 火力発電には原料の確保が海外の動向に左右されることや

More information

05JPOWER_p1-40PDF.p....

05JPOWER_p1-40PDF.p.... 2005 目次 日本の電気事業の現状と J-POWER の位置付け 1 財務状況 1 日本の電気事業概要 1 1 連結財務ハイライト 15 2 当社の発電事業データ 3 2 連結財務諸表 17 3 当社と国内 海外電力会社との比較 5 3 連結収益 費用構成 21 4 単体財務ハイライト 22 7 5 単体財務諸表 23 卸電気事業 7 6 単体電気事業営業収益 費用の分析 29 (1)火力発電 8

More information

目次 1. 実施内容について 背景と目的 2. 海外 P2G 事例 3. FSの中間報告 システム機能概要図 主要設備仕様案 主要設備面積試算と水素量試算 想定スケジュール 技術的要件 送電線 FSにおける今後の検討スケジュール 2017 Toshiba Corporation / Tohoku-E

目次 1. 実施内容について 背景と目的 2. 海外 P2G 事例 3. FSの中間報告 システム機能概要図 主要設備仕様案 主要設備面積試算と水素量試算 想定スケジュール 技術的要件 送電線 FSにおける今後の検討スケジュール 2017 Toshiba Corporation / Tohoku-E 資料 3 福島新エネ社会構想実現会議 再生可能エネルギー由来 水素プロジェクト検討 WG 2017 年 3 月 2 日 株式会社東芝東北電力株式会社岩谷産業株式会社 2017 Toshiba Corporation / Tohoku-Electric Power Co., Inc. / Iwatani Corporation 目次 1. 実施内容について 背景と目的 2. 海外 P2G 事例 3.

More information

北杜市新エネルギービジョン

北杜市新エネルギービジョン 概 要 版 平 成 18 年 3 月 山 梨 県 北 杜 市 1 新エネルギーとは 深刻化する地球温暖化 心配される化石燃料の枯渇といった課題への対策として注目されているのが 新エネル ギー です 新エネルギー とは 太陽や風 森林などの自然のエネルギーなどを活用するもので 石油代替エネ ルギーとして導入が期待されているものの コストなどの制約から普及が十分でないため 積極的に促進を図る必 要があるもの

More information

No

No No. 1 2 No. 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 25 26 No. 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 No. 44 45 46 47 48 49 50 51 52 No. 53 54 55 56 57 58 59 60 61 62

More information

注 1: 要件の判断に係る算定に当たっては 複数の発電用の電気工作物が同一の接続地点に接続している場合は 一つの発電用の電気工作物とみなす 注 2: 特定発電用電気工作物に該当しない電気工作物は 発電事業の要件 ( 小売電気事業用等接続最大電力の合計が 1 万 kw 又は 10 万 kw を超えるも

注 1: 要件の判断に係る算定に当たっては 複数の発電用の電気工作物が同一の接続地点に接続している場合は 一つの発電用の電気工作物とみなす 注 2: 特定発電用電気工作物に該当しない電気工作物は 発電事業の要件 ( 小売電気事業用等接続最大電力の合計が 1 万 kw 又は 10 万 kw を超えるも 改訂箇所は下線部 平成 28 年度発電事業届出書等の記載要領 平成 2 8 年 3 月平成 2 8 年 4 月改訂資源エネルギー庁電力 ガス事業部電力基盤整備課 項目内容 1. 発電事業届出書 (1) 基本事項 発電事業を営もうとする者は 発電事業届出書を提出すること 平成 28 年 4 月 1 日において現に発電事業を営んでいる者は 同年 6 月 30 日までに届出を行うこと ( ただし みなし発電事業者

More information

138 RitsumeikanSocialSciencesReview(Vol53.No.1) OncesuchacodingruleisenteredintoKH Coder,notonlythedocumentscontaining Gilbert butalso thosecontaining

138 RitsumeikanSocialSciencesReview(Vol53.No.1) OncesuchacodingruleisenteredintoKH Coder,notonlythedocumentscontaining Gilbert butalso thosecontaining 第 53 巻第 1 号 A Two-StepApproachtoQuantitativeContentAnalysis(PartI)(HIGUCHIKoichi) RitsumeikanSocialSciencesReview 2017 年 6 月 137 ATwo-StepApproachtoQuantitativeContentAnalysis: KH CoderTutorialUsingAnneofGreenGables(PartII)

More information

Section 1 Section 2 Section 3 Section 4 Section 1 Section 3 Section 2 4 5 Section 1 6 7 Section 1 8 9 10 Section 1 11 12 Section 2 13 Section 2 14 Section 2 15 Section 2 16 Section 2 Section 2 17 18 Section

More information

1 48

1 48 Section 2 1 48 Section 2 49 50 1 51 Section 2 1 52 Section 2 1 53 1 2 54 Section 2 3 55 1 4 56 Section 2 5 57 58 2 59 Section 2 60 2 61 Section 2 62 2 63 Section 2 3 64 Section 2 6.72 9.01 5.14 7.41 5.93

More information

A-5 技術協議録 (Field Report) COE oo く 一 一 OCO oコ一 こ 崎ヨ OC一 0 6 目 コ0 0 E 霞 E じ o3 ooc 9 ピ oocd 憩 O C 〇一 夕0一 0 00 oz 彗姜一 や籍黎場轟 藝輸 電 参轟 轟璽 峰 饉〇

More information

(2) IPP Independent Power Producers IPP 1995 NCC(New Common Carrier NCC NTT NTT NCC NTT NTT IPP 2. IPP 2.1 1995 4 (3) [1] [2] IPP [2] IPP IPP [1] [2]

(2) IPP Independent Power Producers IPP 1995 NCC(New Common Carrier NCC NTT NTT NCC NTT NTT IPP 2. IPP 2.1 1995 4 (3) [1] [2] IPP [2] IPP IPP [1] [2] / 1995 Grid Access Model 1. (1) 22 1998 12 11 2000-1- (2) IPP Independent Power Producers IPP 1995 NCC(New Common Carrier NCC NTT NTT NCC NTT NTT IPP 2. IPP 2.1 1995 4 (3) [1] [2] IPP [2] IPP IPP [1] [2]

More information

untitled

untitled EMG 2014/7/8 Rev. 2015/6/20 IEA 2013 2013 1.5 f=df/dt=r*n*(1 F) F=N/K log(f/(1 f)) 1 0.5 0.5 0 1850 1900 1950 2000 2050 2100 2150 1 1.5 2 2.5 year hydrogen BTG or IGCC power wiki IGCC wiki nuclear

More information

タイトル 著 者 電 気 事 業 の 歴 史 に 見 る 分 散 型 系 統 型 システム 小 坂, 直 人 ; KOSAKA, Naoto 引 用 季 刊 北 海 学 園 大 学 経 済 論 集, 61(4): 81-93 発 行 日 2014-03-30 90 北海学園大学経済論集 表2 第 61巻第4号(2014年3月) 電気事業法の一部を改正する法律案 の概要 注 第 183回国会において参議院にて可決された内容で再提出

More information

円滑な再生可能エネルギーの統合 再生可能資源による電気生産量の増加は すでにストレスとなっているエネルギー供給網にとって新たな挑戦となっています 今日の電力システムは いかなるときでも需給バランスを保ち より柔軟に供給網を管理し エネルギー効率のレベルを確実に最適化することが求められます サフトにで

円滑な再生可能エネルギーの統合 再生可能資源による電気生産量の増加は すでにストレスとなっているエネルギー供給網にとって新たな挑戦となっています 今日の電力システムは いかなるときでも需給バランスを保ち より柔軟に供給網を管理し エネルギー効率のレベルを確実に最適化することが求められます サフトにで エネルギー貯蔵システム 新エネルギー環境の新たなソリューション 円滑な再生可能エネルギーの統合 再生可能資源による電気生産量の増加は すでにストレスとなっているエネルギー供給網にとって新たな挑戦となっています 今日の電力システムは いかなるときでも需給バランスを保ち より柔軟に供給網を管理し エネルギー効率のレベルを確実に最適化することが求められます サフトにできるサポート サフトのリチウムイオンエネルギー貯蔵システムは

More information

78 RitsumeikanSocialSciencesReview(Vol52.No.3) TheanalysisprocedureofStep1issimilartothemethod textmining andisperformedalmost automaticaly.thesameres

78 RitsumeikanSocialSciencesReview(Vol52.No.3) TheanalysisprocedureofStep1issimilartothemethod textmining andisperformedalmost automaticaly.thesameres 第 52 巻第 3 号 A Two-StepApproachtoQuantitativeContentAnalysis(PartI)(HIGUCHIKoichi) RitsumeikanSocialSciencesReview 2016 年 12 月 77 ATwo-StepApproachtoQuantitativeContentAnalysis: KH CoderTutorialusingAnneofGreenGables(PartI)

More information

北海道電力 東北電力 東京電力 中部電力 北陸電力 関西電力 中国電力 四国電力 九州電力 沖縄電力 フランス カナダ イタリア 日本 イギリス ドイツ アメリカ 中国 インド 0.0 0.2 0.4 0.6 0.8 1.0 CO2 排出係数 (kg-co2/kwh) 原子力による発電が多い 水力による発電が多い 石炭火力による発電が多い CO2 排出量 ( ガソリン軽自動車 =100 としたとき

More information

!!! 10 1 110 88 7 9 91 79 81 82 87 6 5 90 83 75 77 12 80 8 11 89 84 76 78 85 86 4 2 32 64 10 44 13 17 94 34 33 107 96 14 105 16 97 99 100 106 103 98 63 at 29, 66 at 58 12 16 17 25 56

More information

固定価格買取制度の認定を受けた発電設備の公表 バイオマス発電の出力抑制対象の見直し 新エネルギーの開発 導入促進に対する支援措置の拡充 規制緩和等 4 再生可能エネルギー固定価格買取制度を効果的に運用する観点から 各地域での導入状況を的確に把握できるよう 固定価格買取制度の認定を受けた発電設備につい

固定価格買取制度の認定を受けた発電設備の公表 バイオマス発電の出力抑制対象の見直し 新エネルギーの開発 導入促進に対する支援措置の拡充 規制緩和等 4 再生可能エネルギー固定価格買取制度を効果的に運用する観点から 各地域での導入状況を的確に把握できるよう 固定価格買取制度の認定を受けた発電設備につい 都道府県から国への要望一覧 事項名要望内容改善案 ( 省庁名を記入してください ) いつまでに実施するか 効果 ( 現状との数値比較等 ) 北本連系線を含む送電網等の増強 電気事業者の再エネ事業者からの接続の請求に応ずる義務 系統連系に関する国の施策 固定価格買取制度に関する使用者 事業者への配慮 要望事項 1 北海道の豊富な新エネルギーのポテンシャルを十分に活かし 導入を拡大していくとともに 本州への送電も可能とするため

More information

1. 用役 ( ユーティリティー ) と用役設備 用役 ( ユーティリティー ) の種類 用役 ( ユーティリティー ) の起動手順 電力供給設備 電力の種類と電圧 電力供給設備とは 発電設備.

1. 用役 ( ユーティリティー ) と用役設備 用役 ( ユーティリティー ) の種類 用役 ( ユーティリティー ) の起動手順 電力供給設備 電力の種類と電圧 電力供給設備とは 発電設備. cq comtecquest 件名基本設計演習 用役プロセス設計指針 作成年月日 2011 年 1 月 10 日 1 1. 用役 ( ユーティリティー ) と用役設備... 3 1.1 用役 ( ユーティリティー ) の種類... 3 1.2 用役 ( ユーティリティー ) の起動手順... 3 2. 電力供給設備... 4 2.1 電力の種類と電圧... 4 2.2 電力供給設備とは... 4 2.3

More information

2 ご議論いただきたい事項 1. 長期方針の中間報告 ( 案 ) 2. 海外事例調査の調査項目案について

2 ご議論いただきたい事項 1. 長期方針の中間報告 ( 案 ) 2. 海外事例調査の調査項目案について 第 11 回広域系統整備委員会資料 3 1 広域系統長期方針の策定について 2016 年 3 月 15 日広域系統整備委員会事務局 2 ご議論いただきたい事項 1. 長期方針の中間報告 ( 案 ) 2. 海外事例調査の調査項目案について 1. 長期方針の中間報告 ( 案 ) 3 1-1. 広域系統長期方針中間報告 ( 案 ) 4 前回委員会以降に頂いた主な意見は以下のとおり これらのご意見を反映し

More information

PowerPoint プレゼンテーション

PowerPoint プレゼンテーション 1 エネルギー業界 概要とトレンド Presented by インダストリー プリンシパル ( 電力 APAC) ヤオミンフェン Industry Principal, Power APAC Yau MingFeng なぜ PI インフラストラクチャー? 課題 : 多種多様なシステム DCS PLC CEMS アナライザー等 さまざまなタイムスタンプ データのアクセスしやすさと整合性 解決策 :OSIsoft

More information

日立評論1990年1月号:電力・エネルギー

日立評論1990年1月号:電力・エネルギー 電力 エネルギー 内需拡大を背景に電力 エネルギーを巡る事 さらに高効率運転とミドル運用への対応を目的と 業環境も好転の兆しを見せており,堅調な伸びが したLNGコンバインドサイクル発電プラントの建 予想されている しかし,社会生活の高度化,多様 設が進められている 大型石炭火力発電所として, 化,さらには地球温暖化など環境問題への関心 1989年には東京電力株式会社広野火力発電所 の高まりとともに電力

More information

開発論集 第95号 71-88(2015年3月) エネルギー供給システムの諸問題 電力システム改革を中心に 小 坂 直 人 周回遅れの自由化の帰趨 2011年3月 11日の東日本大震災と福島原発事故が わが国のエネルギー供給システムの在 り方 とりわけ原子力発電を含む電力システムの在り方に根底的な問

開発論集 第95号 71-88(2015年3月) エネルギー供給システムの諸問題 電力システム改革を中心に 小 坂 直 人 周回遅れの自由化の帰趨 2011年3月 11日の東日本大震災と福島原発事故が わが国のエネルギー供給システムの在 り方 とりわけ原子力発電を含む電力システムの在り方に根底的な問 タイトル 著者 エネルギー供給システムの諸問題 : 電力システム改 革を中心に 小坂, 直人 ; KOSAKA, Naoto 引用開発論集 (95): 71-88 発行日 2015-03-13 開発論集 第95号 71-88(2015年3月) エネルギー供給システムの諸問題 電力システム改革を中心に 小 坂 直 人 周回遅れの自由化の帰趨 2011年3月 11日の東日本大震災と福島原発事故が わが国のエネルギー供給システムの在

More information

目次 1. 再生可能エネルギーの導入状況とコスト競争力 2. 自立化に向けた導入支援策のあり方について 3. 円滑な導入を進めるための電力系統の運用 整備の在り方

目次 1. 再生可能エネルギーの導入状況とコスト競争力 2. 自立化に向けた導入支援策のあり方について 3. 円滑な導入を進めるための電力系統の運用 整備の在り方 資料3 再生可能エネルギーの大量導入時代に おける政策課題について 平成29年5月25日 省エネルギー 新エネルギー部 目次 1. 再生可能エネルギーの導入状況とコスト競争力 2. 自立化に向けた導入支援策のあり方について 3. 円滑な導入を進めるための電力系統の運用 整備の在り方 2 1. 再生可能エネルギーの導入状況と コスト競争力 1 再生可能エネルギーの導入状況とコスト競争力 問題意識 世界的には

More information

スマートライフおすすめ BOOK P2_P 省エネ ネ エ 蓄 ネ 創エ! なるほど はじめに もう中学生! フ イ ラ ト ー マ ス が そ れが それ も くじ 地球温暖化と私たち 4 エネルギーと私たち 6 スマートライフ はじめよう スマートライフ 10 HEMS

スマートライフおすすめ BOOK P2_P 省エネ ネ エ 蓄 ネ 創エ! なるほど はじめに もう中学生! フ イ ラ ト ー マ ス が そ れが それ も くじ 地球温暖化と私たち 4 エネルギーと私たち 6 スマートライフ はじめよう スマートライフ 10 HEMS スマートライフおすすめ BOOK 表 1_ 表 4 2015.05.27 度版 年度版 5年 15 2 01 20 K O O B め おすす と 生 学 中 に もう ボク トライフ ー う スマ 一緒に学ぼ ついて スマートライフジャパン推進フォーラム http://smart-life-japan.jp/ スマートライフジャパン推進フォーラムの活動は 政府が 決定した省エネルギー対策の取り組みに位置づけられています

More information

(Microsoft Word - \203x\203\213\203M\201[.docx)

(Microsoft Word - \203x\203\213\203M\201[.docx) 1 ベルギー 3. ベルギー 3.1 政府の目標 ベルギーは 京都議定書に基づき 2008 年から 2012 年の間の温室効果ガスの年平均総排出量を 1990 年実績値を基準に 7.5% 削減する事を目標としている 2009 年の排出量は 1990 年実績値を 14.6% 下回った 同国は コペンハーゲン合意に基づき 欧州連合の排出量取引制度の対象とならない産業部門においては 排出量を 2020 年までに

More information

I

I 研究レポート No.301 October 2007 エネルギー分野の規制改革 ( 第 2 段階 ) のあり方 - 電力分野に関する検討 客員研究員武石礼司 富士通総研 (FRI) 経済研究所 エネルギー分野の規制改革 ( 第 2 段階 ) のあり方 - 電力分野に関する検討 1. はじめに 富士通総研経済研究所武石礼司 takeishi.reiji@jp.fujitsu.com 2000 年以降に進められてきた電力分野での規制改革により

More information

JP-AN-186_Feb_2015 -JP

JP-AN-186_Feb_2015 -JP [ APPLICATION NOTE #186 ] PowerChute TM Network Shutdown アドバンスド冗長セットアップ By David Grehan, Sarah Jane Hannon 概要 PowerChute TM Network Shutdown は APC UPS Network Management Card と 連動し 物理環境及び仮想環境の双方に おいて IT

More information

中山間地域ってなあに?

中山間地域ってなあに? 農 業 水 利 施 設 を 活 用 した 小 水 力 発 電 等 発 電 施 設 導 入 のポイント 農 村 振 興 課 環 境 対 策 担 当 平 成 27 年 3 月 6 日 目 次 1 農 業 農 村 の 概 況 1 2 再 生 可 能 エネルギーの 利 用 可 能 量 2 3 農 村 地 域 における 太 陽 光 発 電 の 手 引 ( 抜 粋 ) 5 4 農 業 用 水 を 活 用 した

More information

Microsoft PowerPoint - new_ NEDOフォーラムTS-9第3部(山田)r2公開用.pptx

Microsoft PowerPoint - new_ NEDOフォーラムTS-9第3部(山田)r2公開用.pptx 第 3 部国民負担と発電コストの削減 NEDO の PV 発電コスト削減シナリオ (NEDO PV Challenges より ) ( 独 ) 新エネルギー 産業技術総合開発機構 (NEDO) ( 独 ) 新エネルギ 産業技術総合開発機構 (NEDO) 新エネルギー部主任研究員山田宏之 本日の内容 1. 太陽光発電開発戦略 NEDO PV Challenges 策定経緯と概要 2. 発電コスト低減目標

More information

<4D F736F F D A A92B78AFA C838B834D815B8EF98B8B8CA992CA82B E82AF8D9E82DC82B581468C6F8E598FC8834E838C A2E646F6378>

<4D F736F F D A A92B78AFA C838B834D815B8EF98B8B8CA992CA82B E82AF8D9E82DC82B581468C6F8E598FC8834E838C A2E646F6378> 長期エネルギー需給見通し 平成 27 年 7 月 経済産業省 ( はじめに ) 昨年 4 月に閣議決定されたエネルギー基本計画を受け 総合資源エネルギー調査会基本政策分科会長期エネルギー需給見通し小委員会を設置し そこでの検討を経て 今般 取りまとめを行うものである エネルギー政策の推進に際し まず 東日本大震災と東京電力福島第一原子力発電所の事故を受け 行政や事業者は 国民からの信頼を著しく低下させることになったことを深く反省しなければならない

More information

2

2 2 3 4 5 6 7 0 10 20 30 40 50 60 70 9 10 11 12 13 14 15 86.0% 14.0% 79.5% 20.5% 60 111 16 .. 17 ** p

More information

i-1 電気事業制度についてー 1 自由化 2000 年 3 月から大口需要家に対する電力小売が自由化 その後 2004 年 4 月 2005 年 4 月と 自由化範囲が段階的に拡大 さらに 電力システム改革専門委員会での検討を踏まえ 2016 年 4 月から小売全面自由化が開始された (j-3 参

i-1 電気事業制度についてー 1 自由化 2000 年 3 月から大口需要家に対する電力小売が自由化 その後 2004 年 4 月 2005 年 4 月と 自由化範囲が段階的に拡大 さらに 電力システム改革専門委員会での検討を踏まえ 2016 年 4 月から小売全面自由化が開始された (j-3 参 FEPC INFOBASE i - 電気事業制度 i-1 電気事業制度についてー 1 自由化 2000 年 3 月から大口需要家に対する電力小売が自由化 その後 2004 年 4 月 2005 年 4 月と 自由化範囲が段階的に拡大 さらに 電力システム改革専門委員会での検討を踏まえ 2016 年 4 月から小売全面自由化が開始された (j-3 参照 ) (1) 自由化範囲の拡大小売の部分自由化は

More information

再生可能エネルギー 入力支援システム操作マニュアル

再生可能エネルギー 入力支援システム操作マニュアル 再生可能エネルギー年報報告操作マニュアル 年報報告者の方向け 平成 26 年 10 月 31 日 Ver.1.3 1 目次 1. はじめに (1) 本マニュアルについて 3 (2) 画面構成図 ( 簡易版 ) 4 2. ログインとログアウト (1) ログインする 5 (2) ログアウトする 7 3. 年報報告 ( 設置費用報告 ) の手続き (1) 設置費用の登録を行う 9 (2) 設置費用報告の登録を行う

More information

1. 欧州概要 (1) 欧州各国の電源構成 (2016 年 ) 1 欧州では各国の電源構成の違いが大きい 再生可能エネルギー発電の電力消費に対する割合の高い国はデンマーク (51.8%) ポルトガル (31.8%) ドイツ (29.5%) アイスランド (26%) スペイン (24.8%) アイルラ

1. 欧州概要 (1) 欧州各国の電源構成 (2016 年 ) 1 欧州では各国の電源構成の違いが大きい 再生可能エネルギー発電の電力消費に対する割合の高い国はデンマーク (51.8%) ポルトガル (31.8%) ドイツ (29.5%) アイスランド (26%) スペイン (24.8%) アイルラ 資料 2 欧州における再生可能エネルギー発電導入拡大に伴う動き 一般財団法人日本エネルギー経済研究所 総括研究主幹小笠原潤一 1. 欧州概要 (1) 欧州各国の電源構成 (2016 年 ) 1 欧州では各国の電源構成の違いが大きい 再生可能エネルギー発電の電力消費に対する割合の高い国はデンマーク (51.8%) ポルトガル (31.8%) ドイツ (29.5%) アイスランド (26%) スペイン

More information

エネルギー・リソース・アグリゲーション・ビジネスについて

エネルギー・リソース・アグリゲーション・ビジネスについて 資料 4 エネルギー リソース アグリゲーション ビジネスについて 需要家側エネルギーリソースの規模感 創エネ設= 大規模火力約 24 基分備 長期エネルギー需給見通し ( 平成 27 年 7 月 ) 等をもとに 主な需要側エネルギーリソースの規模感を試算すると 以下の通り 2030 年に向けて 需要家側に相当程度のエネルギーリソースが導入される見込み 従来の大規模集中型エネルギーシステムに加えて

More information

スマートグリッドと電気自動車

スマートグリッドと電気自動車 平成 24 年 4 月 11 日 1 住宅用太陽光については余剰買取を維持すべきとの国会質疑 住宅用太陽光についての買取は 再生可能エネルギー特措法の国会審議において 余剰買取を継続するとの方針が繰り返し確認されている 住宅用太陽光に係る買取方式に関する国会審議 ( 例 ) < 平成 23 年 7 月 27 日衆議院 経済産業委員会より > 近藤三津枝 ( 自民 ) 議員経済産業大臣 住宅からの買い取りは

More information

電気エネルギーをつくる方法 火力発電化石燃料を燃やしてを沸騰させ, その蒸気の力でタービンを回転させて発電します ( 利点 ) 電気をたくさんつくることができる 電気をつくる量を調節しやすい ( 課題 ) 二酸化炭素が大量発生する ( 地球温暖化の原因になる ) 燃料 ( 天然ガス, 石炭, 石油

電気エネルギーをつくる方法 火力発電化石燃料を燃やしてを沸騰させ, その蒸気の力でタービンを回転させて発電します ( 利点 ) 電気をたくさんつくることができる 電気をつくる量を調節しやすい ( 課題 ) 二酸化炭素が大量発生する ( 地球温暖化の原因になる ) 燃料 ( 天然ガス, 石炭, 石油 山梨市立山梨南中学校の太陽光発電システム 年 組氏名 山梨県教育庁義務教育課 電気エネルギーをつくる方法 火力発電化石燃料を燃やしてを沸騰させ, その蒸気の力でタービンを回転させて発電します ( 利点 ) 電気をたくさんつくることができる 電気をつくる量を調節しやすい ( 課題 ) 二酸化炭素が大量発生する ( 地球温暖化の原因になる ) 燃料 ( 天然ガス, 石炭, 石油 ) に限りがある 火力発電

More information

経済産業省 資源エネルギー庁 2

経済産業省 資源エネルギー庁 2 経済産業省 資源エネルギー庁 平成24年11月 資源エネルギー庁 新エネルギー対策課 1 経済産業省 資源エネルギー庁 2 モデル契約書作成の経緯について モデル契約書作成のニーズについては パブリックコメント等でも頂いていたところであり 当課としても 特定契約の締結や接続の円滑化のための 契約環境の整備は 重要な課題として認識 また 固定価格買取制度の施行後 電力各社が用意している再生可能エネルギー発電事業者との契約書では

More information

<4D F736F F D2091E F A982E789FC915082F08AA98D9082B382EA82BD CC91BE977A8CF594AD93642E646F63>

<4D F736F F D2091E F A982E789FC915082F08AA98D9082B382EA82BD CC91BE977A8CF594AD93642E646F63> 第 2 回 IEA から改善を勧告されたドイツの太陽光発電両立しない Cap and trade と固定価格買取制度山口光恒東京大学先端科学技術研究センター特任教授 はじめに前回はスペインでの太陽光発電促進策の迷走ぶりを基に 今後の日本の再生可能エネルギー論議に於いて単なる量的拡大を求めるのではなく 経済への影響 ( コスト ) 環境効果 エネルギー安定供給 雇用 電力料金値上げによる国民生活や企業の国際競争力への影響

More information

Folie 1

Folie 1 Political Situation after the Fukushima accident in Germany! 福島原発事故後のドイツにおける政治情勢 Thomas Breuer, CFA Head of Climate- and Energy Department Greenpeace Germany トーマス ブリュアーグリーンピース ドイツ気候変動 エネルギー部門リーダーファイナンシャル

More information

Microsoft Word - 【r1】NRA指示 「1相欠相故障」に対する報告書【 報告(monju)】

Microsoft Word - 【r1】NRA指示 「1相欠相故障」に対する報告書【 報告(monju)】 米国情報 電源系統の設計における脆弱性 に係る報告について 平成 25 年 12 月 独立行政法人 日本原子力研究開発機構 目 次 1. はじめに 1 2. 米国 Byron2 号機の事象の概要及び米国の対応状況について 1 3. 電源系の設備構成及び負荷の状態について 2 4. 外部電源系の 1 相開放故障の発生想定箇所について 2 5. 報告内容 3 6. まとめ 5 添付資料 -1 高速増殖原型炉もんじゅ電源構成概要図

More information

スライド 1

スライド 1 内外における電力自由化 の到達点と課題 学習院大学矢島正之会津大学大藤建太電力中央研究所後藤美香 後藤久典 井上智弘 公益事業学会政策研究会 1 内容 内外における電力自由化の現状 米国 EU 日本 内外における電力自由化のパフォーマンス わが国における電力自由化の課題 公益事業学会政策研究会 2 内外における電力自由化の現状 EU 全面自由化と構造分離 米国 全面自由化と構造分離および規制と垂直統合の併存

More information

コンテンツ・プロデュース機能の基盤強化に関する調査研究

コンテンツ・プロデュース機能の基盤強化に関する調査研究 Introduction コンテンツ プロデュース機能の 基盤強化に関する調査研究 プロデューサー論 CONTENTS Chapter 1 Section 1 Section 2 Section 3 Section 4 Section 5 Chapter 2 Section 1 Section 2 Section 3 Section 4 Section 5 Chapter 3 Section

More information

「諸雑公文書」整理の中間報告

「諸雑公文書」整理の中間報告 30 10 3 from to 10 from to ( ) ( ) 20 20 20 20 20 35 8 39 11 41 10 41 9 41 7 43 13 41 11 42 7 42 11 41 7 42 10 4 4 8 4 30 10 ( ) ( ) 17 23 5 11 5 8 8 11 11 13 14 15 16 17 121 767 1,225 2.9 18.7 29.8 3.9

More information

会社案内2015(日本語)

会社案内2015(日本語) 17VISION Glorious Excellent Company 12 VISION 07 VISION 新たな社会ニーズへ 裾野の広い事業領域を活かし 新たな社会インフラの構築に貢献 当社グループでは これまでにご紹介した裾野の広い事業領域を活かし 私たちの未来社会のニーズに合わせたソリューション 住友電工グループの考える スマートエネルギーシステム を提供していきます その一例として

More information

なエネルギーの利用を拡大するに当たっては 地方自治体が新たにエネルギー分野でサービス提供をするために活動を開始するという 地方自治体への機能復帰 Re-Kommunalisierung があると共に 市民が自ら団結し エネルギー分野で活躍するという市民参加型の形態もあり 相互の関連性もある 地方自治

なエネルギーの利用を拡大するに当たっては 地方自治体が新たにエネルギー分野でサービス提供をするために活動を開始するという 地方自治体への機能復帰 Re-Kommunalisierung があると共に 市民が自ら団結し エネルギー分野で活躍するという市民参加型の形態もあり 相互の関連性もある 地方自治 ( 財 ) 自治体国際化協会ロンドン事務所マンスリートピック (2012 年 8 月 ) エネルギー協同組合は 再生可能なエネルギーへの転換に大きく貢献している イエンス テッスマンポツダム大学地方自治研究所イルメリン キルヒナー訳 編集 ドイツのエネルギー転換とエネルギー協同組合ドイツのエネルギー市場では 再生可能なエネルギーへの政策転換と共に エネルギー生産やエネルギー供給の組織体制の変化も同時に始まっている

More information

A Study on Food Cost Viewed in Relation to Nutrition (Part 1) Fluctuations in Food Costs by Month Yasuko IZUSHI Kimiko MATSUDA No satisfactory way had been found to apprehend the food cost from the viewpoint

More information

untitled

untitled 2006 Progress Report on the Economic Well-Being of Working-Age People with Disabilities Employment of Disabled People in Europe in 2002 Statistics in Focus Code of Practice on Managing Disability in the

More information

再生可能エネルギー発電と二次電池を導入した地域電力システムのシミュレーションによる設計

再生可能エネルギー発電と二次電池を導入した地域電力システムのシミュレーションによる設計 Copyright 2005-2010 Miyata / Akimoto / Tanaka Lab. All rights reserved. 二次電池による社会システムイノベーション第 10 回分科会 2012/2/23 リアルタイムの地域電力経営法と充放電アルゴリズムの選択 東京大学大学院工学系研究科 システム創成学専攻 宮田秀明研究室 M2 今西佑希 M1 柴田一樹 目次 1. 本研究の趣旨

More information

電気電子発送配変電二次練習問題

電気電子発送配変電二次練習問題 Copy Rght (c) 008 宮田明則技術士事務所 . ()() () n n 60 f f f 50, 60503000rp(n - ) f 60, 66060300rp(n - ) f 50, 060500300rp(n - ) f 50, 46050500rp(n - ) N N N (6) N () Copy Rght (c) 008 宮田明則技術士事務所 . r a, r a a a

More information

スライド 1

スライド 1 資料 4 ドイツ フランスのスマートグリッド関連動向 ( スマートコミュニティアライアンス官民訪欧ミッションより ) 1. 官民訪欧ミッションの概要 2. ドイツのスマートグリッド関連動向 (1) ドイツがスマートグリッドに取り組む背景 (2)E-Energy プロジェクトの背景 目的 (3)E-Energy プロジェクトの概要 (4)MOMA(Model City of Mannheim) プロジェクトの概要

More information

140424 部門Aドイツ電力市場改革について.pptx

140424 部門Aドイツ電力市場改革について.pptx ドイツ 電 力 市 場 改 革 について (Strategic Reserve と Capacity Market) 140424 部 門 A 研 究 会 東 愛 子 1 ドイツ 電 力 市 場 の 概 況 発 電 量 発 電 所 ( 非 変 動 電 源 )への 投 資 状 況 RE( 変 動 電 源 )への 対 応 調 整 電 源 の 役 割 送 電 網 投 資 Ø 問 題 点 送 電 網 投 資

More information

???? (Page 1)

???? (Page 1) ⅰ) ⅱ) ⅲ) 6000000 5000000 4000000 3000000 2000000 1000000 0 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 - 1000000 900000 800000 700000 600000 500000 400000 300000 200000 100000 0 2000 2001

More information

利 益 の 処 分 に 関 する 書 類 ( 平 成 21 年 1 月 8 日 ) ( 単 位 : 円 ) Ⅰ 当 期 未 処 分 利 益 460,303,065 当 期 総 利 益 460,303,065 Ⅱ 利 益 処 分 額 積 立 金 35,393,310 国 立 大 学 法 人 法 第 35 条 において 準 用 する 独 立 行 政 法 人 通 則 法 第 44 条 第 3 項 により

More information

わが国におけるスマートグリッドのかたち 理事 加藤有一

わが国におけるスマートグリッドのかたち 理事 加藤有一 総括報告 わが国における スマートグリッドのかたち 理事 加藤有一 by CRIEPI 本日お話ししたいこと 1. スマートグリッドと名付けられた電力 システムなどに 関係者はどんな期待を 持っているのか? 2. 関係者それぞれに捉え方が異なる スマートグリッド 電中研はそれを どのように捉えているのか? 2 1. スマートグリッドの現状 内容と要旨 スマートグリッドの概念 期待される効果 各国のスマートグリッド

More information

30 3 3 6,745 3,000 JK 34 2 2

30 3 3 6,745 3,000 JK 34 2 2 .03.06 1 30 3 3 6,745 3,000 JK 34 2 2 3 110 70 LVL 4 5 6 7 8 9 10 11 12 13 14 エネルギー ①パッシブ技術と先進アクティブ技術で 80%省エネルギーを実現する住宅 提案と結果 エネマネハウス 反省点 GJ 55.0 電気使用量の増大 予想される原因と して建物のボリューム 空調負荷 45.0 20.9 給湯負荷抑制 35.0

More information

Table 1. Main specifications of VAD plant. Fig. 2. Typical operating pattern of low alloy steel.

Table 1. Main specifications of VAD plant. Fig. 2. Typical operating pattern of low alloy steel. UDC 669. 184. 244. 66-251: 669. 046. 554-982 On the Operations of LD-VAD Process and Product Qualities Takaharu MORIYA and Masanori TAWARA Synopsis: VAD (Vacuum Arc Degassing) plant is characterized by

More information

1997889 9 200111 8 20004 200110 LDI NOTES

1997889 9 200111 8 20004 200110 LDI NOTES 1997889 9 200111 8 20004 200110 LDI NOTES 2050 661 200111 628950 1 2012 5986 2 40507 2 545 25141 3 562519 486 4 56237620 2022950609 50 6 50 30 6 200111 809 788 5862 826 545 4833 507 6 3 1 2312 5 6 720

More information

横山.indd

横山.indd Technical Report 報文 リチウムイオン電池対応太陽光発電システム ラインバック ΣⅢ の開発 Development of Photovoltaic Generation System LINE BACK III Connectable to Li-ion 横山昌央 横山晋 遠藤浩輝 也 Yiga 詫 間 隆 史 Allan Masao Yokoyama Hiroaki Endo Takafumi

More information

<4D6963726F736F667420576F7264202D20819C475245323031348D918DDB89EF8B638376838C835894AD955C285A89FC92E890B388C4293134303330352E646F63>

<4D6963726F736F667420576F7264202D20819C475245323031348D918DDB89EF8B638376838C835894AD955C285A89FC92E890B388C4293134303330352E646F63> 報 道 関 係 者 各 位 2014 年 3 月 24 日 グランド 再 生 可 能 エネルギー2014 国 際 会 議 組 織 委 員 会 Grand Renewable Energy 2014 グランド 再 生 可 能 エネルギー2014 国 際 会 議 国 際 太 陽 エネルギー 学 会 アジア 太 平 洋 地 域 2014 国 際 会 議 及 び 第 2 回 海 洋 エネルギー 国 際 会

More information

00_testo350カタログ貼込.indd

00_testo350カタログ貼込.indd Committing to the future testo 350 C O NO NO HS HC ダストフィルターは簡単に交換 ワンタッチでコントロールユニットの装着 排ガス測定ボックス背面には開口部が ありメンテナンスが容易 蓋を外した状態 コントロールユニットは裏返しでも装着 可能 輸送時の衝撃から保護 ドレンタンクがついているので 長時間 測定でも安心 コントロールユニットの接続部分 現場でのさまざまな使用環境に対応

More information

CW3_A5154A01.indd

CW3_A5154A01.indd 1 2 3 4 . 5 6 7 . cm. m 8 m m 9 m m m m m m 10 . m m 11 12 13 . 14 15 16 17 18 19 20 21 i i RICO 22 i Governance December 23 24 25 NIKKEI ARCHITECTURE Straßen und Baufluchtlinie Gesetz 26 http://www.hiraoka.rose.ne.jp/a

More information

029-042_flC

029-042_flC 51 2008 29 42 Ren Tie hua 1960 1881 12 1984 51 2008 1882 10 1879 1879 24 1880 65 249,477 1981 22 1880 33 351993 1995 12 1988 1992 1955 1970 120 1964 167 21 1974 118 121 1879 1881 50 1880 10 11 1880 12

More information

効率化計画冊子ファイナル.PDF

効率化計画冊子ファイナル.PDF - 1 - - 2 - - 3 - - 4 - - 5 - - 6 - - 7 - - 8 - - 9 - - 10 - - 11 - - 12 - - 13 - - 14 - - 15 - - 16 - - 17 - (77kV) (6kV) (77kV6kV 6kV - 18-77kV 10%20% - 19 - - 20 - - 21 - - 22 - - 23 - - 24 - DB( )

More information

スライド 1

スライド 1 津波 原子力災害被災地域雇用創出企業立地金 復興 平成 25 年度補正予算案 330.0 億円 地域経済産業グループ産業施設課 03-3501-1677 福島産業復興推進室 03-3501-8574 中小企業庁商業課 03-3501-1929 東日本大震災で特に大きな被害を受けた津波浸水地域 ( 青森県 岩手県 宮城県 福島県 茨城県 ) 及び原子力災害により甚大な被害を受けた避難指示区域等であって避難指示が解除された地域をはじめとする福島県の産業復興を加速するため

More information

スライド 1

スライド 1 WEEE RoHS Supply Chain Management 10.29 1 2 3 4 WEEE WEEE RoHS RoHS TAC TAC Official Journal ( Official Journal ( 2003 2003 2 13 13 WEEE WEEE 9 2003 2003 12 12 31 31 RoHS RoHS 2004 2004 7 5 TAC TAC Work

More information