Express5800/iR110a-1Hユーザーズガイド
|
|
- きのこ かんけ
- 5 years ago
- Views:
Transcription
1 3
2 w w w w w
3 Press <F2> to enter SETUP Enter password [ ]
4 Main System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Power ON Delay Time: Platform Event Filtering: PhoenixBIOS Setup Utility Advanced Security Server Boot Exit [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to view server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
5
6
7
8
9 w w w w w w
10 PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit System Time: System Date: Hard Disk Pre-Delay: SATA Port 0 SATA port 1 SATA Port 2 SATA Port 3 [14:18:58] [10/04/2007] [Disabled] [250GB SATA0] [250GB SATA1] [None] [None] Item Specific Help <Tab>, <Shift-Tab>, or <Enter> selects field. Processor Settings Language: [English] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit ç ñ
11 w w w Main PhoenixBIOS Setup Utility Processor Settings Item Specific Help Processor Retest: Processor Speed Setting: Processor 1 CPUID: Processor 1 L2 Cache: [No] 2530 MHz A 6144 KB Select 'Yes', BIOS will clear historical processor status and retest all processors on next boot. Active Processor Cores: Execute Disable Bit: Intel SpeedStep(R) Technology: C1 Enhanced Mode: Virtualization Technology: Hardware Prefetcher: Adjacent Cache Line Prefetch: [All] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
12
13 PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Item Specific Help Memory Configuration PCI Configuration Peripheral Configuraion Advanced Chipset Control Additional setup menus to configure Memory devices. Boot-time Diagnostic Screen: Reset Configuration Data: NumLock: Memory/Processor Error: [Disabled] [No] [Off] [Boot] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
14 Advanced PhoenixBIOS Setup Utility Memory Configuration Item Specific Help Installed memory: Available under 4GB: DIMM #1 Status: DIMM #2 Status: DIMM #3 Status: DIMM #4 Status: Memory Retest: Extended RAM Step: MB 3328 MB Normal Normal Normal Normal [No] [Disabled] Enables DIMM sparing feature. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
15 Advanced PhoenixBIOS Setup Utility PCI Configuration Item Specific Help Onboard Video Controller Onboard LAN 1 Onboard LAN 2 PCI Slot 1 Option ROM: [Enabled] Additional setup menus to configure onboard Video controller. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
16 Advanced PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port B: Base I/O address: Interrupt: USB Controller: USB 2.0 Controller: Serial ATA: Native Mode Option: SATA Controller Mode Option: SATA AHCI: SATA RAID: [Enabled] [2F8h] [IRQ 3] [Enabled] [Enabled] [Enabled] [Serial ATA] [Enhanced] [Enabled] [Disabled] Configure Serial Port using options: [Disabled] No configuration [Enabled] User configuration F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
17
18 Advanced PhoenixBIOS Setup Utility Advanced Chipset Control Item Specific Help Multimedia Timer: Intel (R) I/O AT: Wake On LAN/PME: Wake On Ring: Wake On RTC Alarm: [Enabled] [Enabled] [Enabled] [Disabled] [Disabled] Enable/Disable Multimedia Timer (HPET). F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
19 Main Advanced PhoenixBIOS Setup Utility Security Server Boot Exit Supervisor Password Is: User Password Is: Set Supervisor Password Set User Password Clear Clear [Enter] [Enter] Item Specific Help Supervisor Password controls access to the setup utility. Password on boot: Fixed disk boot sector: Power Switch Inhibit: [Disabled] [Normal] [Disabled] Disable USB Ports: [Disabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit w w w
20
21 Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Power ON Delay Time: Platform Event Filtering: [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to view server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
22
23 PhoenixBIOS Setup Utility Server System Management Item Specific Help BIOS Revision: Board Part Number: Board Serial Number: System Part Number: System Serial Number: Chassis Part Number: Chassis Serial Number: Onboard LAN1 MAC Address: Onboard LAN2 MAC Address: Management LAN MAC Address: BMC Device ID: BMC Device Revision: BMC Firmware Revision: SDR Revision: xxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx All items on this meenu cannot be modified in user mode. If any items require changes, please consult your system Supervisor. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
24 PhoenixBIOS Setup Utility Server Console Redirection Item Specific Help BIOS Redirection Port: Baud Rate: Flow Control: Terminal Type: Continue Redirection after POST: Remote Console Reset: [Disabled] [19.2K] [CTS/RTS] [VT100+] [Enabled] [Disabled] Selects the Serial port to use for Console Redirection. Disabled completely disables Console Redirection. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
25 PhoenixBIOS Setup Utility Server BMC LAN Configuration Item Specific Help LAN Connection Type: IP Address: IP Subnet Mask: Default Gateway: DHCP: [Auto Negotiation] [ ] [ ] [ ] [Disabled] Display IP Address. Web Interface HTTP: HTTP Port Number: HTTPS: HTTPS Port Number: [Disabled] [ 80] [Disabled] [ 443] Command Line Interface Telnet: Telnet Port Number: [Disabled] [ 23] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
26 w w
27 PhoenixBIOS Setup Utility Server System Event Log Event Log Configuration Setup Notice If you select "System Event Log" menu below, it may take a few minutes to display. Item Specific Help Display the System Event Log Auto Clear Event Logs: Clear All Event Logs: [Disabled] [Enter] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
28 PhoenixBIOS Setup Utility Server System Event Log Item Specific Help SEL Entry Number = SEL Record ID = SEL Record Type = Timestamp = Generator ID = SEL Message Rev = Sensor Type = Sensor Number = SEL Event Type = Event Description = SEL Event Data = 1/ System Event Record 2007/08/05 10:58: System Event 87 - System Event 6F - Sensor specific OEM System Boot Event 41 8F FF This is an entry The System Event Log. Eyes used to view. Up arrow :Newer SEL Down arrow :Older SEL <->:Newer SEL <+>:Older SEL Home:Newer SEL End :Older SEL F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
29 PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Boot priority order: 1: USB CDROM: GENERIC DVD-ROM B763B 2: IDE CD: 3: USB FDC: 4: USB KEY: 5: IDE HDD: 6: USB HDD: 7: PCI SCSI: P0-WDC WD800BLFS-19YBU0 8: PCI BEV: IBA GE Slot 0100 v1322 Excluded from boot order: : PCI BEV: IBA GE Slot 00CB v1250 Item Specific Help Keys used to view or configure devices: Up and Down arrows select a device. <+> and <-> moves the device up or down. <x> exclude or include the device to boot. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
30 Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit Exit Saving Changes Exit Discarding Changes Load Setup Defaults Load Custom Defaults Save Custom Defaults Disacard Changes Save Changes [Enter] [Enter] Item Specific Help Exit System Setup and save your changes to CMOS. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Execute Command F10 Save and Exit
31
32 w w
33 w w w w w w w w w w
34
35
36
37 w w
38
39
40
41 w w w
42 w w w w w w w
43 LSI Software RAID Configuration Utility Ver xxx Management Menu Configure Initialize Objects Rebuild Check Consistency Configure Logical Drive(s) Use cursor keys to navigate between items and Press ENTER to select an option
44
45
46 w w
47 A-0 SPAN-1 Select Configurable Array(s)
48 Virtual Drives Configured LD 0 RAID 1 Size xxxmb #Stripes 2 StrpSz 64KB Status ONLINE Virtual Drive0 RAID = 1 Size = xxxxmb DWC = On RA = On Accept Span = NO
49
50
51
52 w w
53 w w
54
55 w w
56
Express5800/i110Rc-1hユーザーズガイド
3 Press to enter SETUP Enter passord [ ] Main System Management Console Redirection Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring
More informationNEC Express5800/E110b-Mユーザーズガイド
2 Press to enter SETUP Press to enter SETUP or to Network Press to resume, to enter Setup, to Network Enter password[ ] Main Phoenix SecureCore(tm)
More informationIP1_ug.book
1 1 2 Press to enter SETUP 1 2 1 Press to enter SETUP Enter passord[ ] Phoenix TrustedCore(tm) Setup Utility Main Advanced Security System Hardare
More informationExpress5800/110Geユーザーズガイド
2 Press to enter SETUP or Press to boot from Netork Press to Run LSI Softare RAID Configuration Utility. Press for SCSISelect(TM) Utility! 1
More informationExpress5800/120Rj-2 ユーザーズガイド
2 ID 0 1 3 4 2 5 1 2 2 1 0 3 1 4 2 5 A 2 1 1 2 0 3 1 4 2 5 Press to enter SETUP, to Netork Press for SCSISelect(TM) Utility! 0 3 1 4 2 5 0 1 3 4 2
More informationT120Ra-1ユーザーズガイド
3 Press to enter SETUP Enter passord[ ] Main System Management Console Redirection Event Log Configuration PhoenixBIOS Setup Utility Advanced Security Server Boot Exit Assert NMI on PERR : [Enabled]
More informationiStorage NS47Pユーザーズガイド
5 Press to enter SETUP or Press to boot from Netork Enter passord[ ] Main Phoenix cme FirstBIOS Pro Setup Utility Advanced Security Server Boot Exit System Management Console Redirection Event
More informationExpress5800/110Gd-Sユーザーズガイド
2 2 1 1 2 Press to enter SETUP or Press to boot from Netork Press to Run LSI Logic Softare RAID Setup Utility. Press for SCSISelect(TM) Utility! Press
More informationiStorage NS500Rbユーザーズガイド
5 w w w w w Press to enter SETUP or Press to boot from Network Enter Password Main System Management BMC LAN Configuration Event Log Configuration Advanced Security Server Boot Save & Exit Additional
More informationExpress5800/110Gbユーザーズガイド
2 OUTPUT UN(SWITCH OUT) AC100V 50/50HZ TOTAL 12.5A OUTPUT(SWITCH OUT) Press to enter SETUP or Press to boot from Netork Press for Adaptec RAID Configuration Utility! Press
More informationExpress5800/GT120b ユーザーズガイド
2 1 2 Press to Run LSI Softare RAID Configuration Utility. Press for Web BIOS Press for SASSelect(TM) Utility! Press to enter SETUP 2
More informationExpress5800/R120b-2ユーザーズガイド
2 ID 1 2 2 1 2 1 1 2 Press to enter SETUP or Press to boot from Netork Press for SCSISelect(TM) Utility! 1 2 3
More information1 138
5 1 2 3 4 5 6 7 8 1 138 BIOS Setup Utility MainAdvancedSecurityPowerExit Setup Warning Item Specific Help Setting items on this menu to incorrect values may cause your system to malfunction. Select 'Yes'
More informationExpress5800/InternetStreamingServer ES ユーザーズガイド
5 Press to enter boot selection menu Press to enter SETUP or Press to Netork Press to enter boot selection menu Press to enter SETUP, Service Partition, Netork Press
More information137 6 1 2 3 4 5 6 138 6 139 1 2 3 4 5 6 140 6 141 1 2 1 2 142 6 3 143 1 2 144 6 145 1 2 3 4 5 146 6 147 1 1 148 6 1 2 149 1 2 1 2 150 6 151 152 6 1 2 153 1 2 3 154 1 2 6 3 155 156 6 157 158 1 6 2 159 1
More information1 142
7 1 2 3 4 5 6 7 8 1 142 PhoenixBIOS Setup Utility MainSystem DevicesSecurityPowerOthersBootExit System Time: [XX:XX:XX] Item Specific Help System Date: [XX/XX/XXXX] Floppy Drive: 1.44MB, 3 1 / 2" Hard
More informationHA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2
HB102050A0-4 制限 補足 Esc Enter Esc Enter Esc Enter Main Advanced Server Security Boot Exit A SATA Configuration SATA Controller(s) SATA Mode Selection [Enabled] [RAID] Determines how
More information1 122
6 1 2 3 4 5 6 1 122 PhoenixBIOS Setup Utility MainAdvancedSecurityPowerExit MainSystem DevicesSecurityBootExit System Time: [XX:XX:XX] [XX:XX:XX] System Date: [XX/XX/XX] [XX/XX/XXXX] Item Specific Help
More informationExpress5800/340Hb-Rユーザーズガイド(セットアップ編)
4 B 1 2 Phoenix BIOS Setup Utility Main Advanced Stratus Security Boot Exit System Time : System Date : Primary Master Primary Slave [15:23:34] [01/30/2004] CD-ROM ATRPI Removable Item Specific Help
More informationExpress5800/320Lb, 320Lb-R, 320Lb2-R, 320Lc, 320Lc-Rユーザーズガイド(セットアップ編)
4 B 1 2 Phoenix BIOS S etup Utility Main Advanced Security System Hardare Boot Exit Processor Type : Processor Speed : Cache RAM : System Memory : Extended Memory : Intel (R) Xeon (TM) processor 2.80
More information4 FT ID 1 0 NMI CPU MEM3 MEM2 MEM1 PSU TMP FAULT I/O FAN2 FAN1 VLT HCS2 HCS1 Phoenix BIOS Setup Utility Main Advanced Security Server Boot Exit System Time: System Date: Processor Settings [14:00:09]
More informationEQUIUM EQUIUM S5010 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 8 4 1 2 3 5 1 2 1 2 3 4 5 6 7 6 1 3 7 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 4 5 6 7 8 1 1 2 3 4 10 1 11 12 1 13 14 1 15 1 16 1 1 17 1 2 18 3 1 4 5 19
More informationExpress5800/120Egユーザーズガイド
2 1 1 1 2 2 OUTPUT OUTPUT(SWITCH OUT) UN(SWITCH OUT) AC100V 50/50HZ TOTAL 12.5A Press to enter SETUP Press for SCSISelect(TM) Utility! Press
More informationEQUIUM EQUIUM 1
EQUIUM EQUIUM 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 8 9 4 1 2 3 5 1 2 3 1 2 3 4 5 6 7 6 1 3 7 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 4 5 6 7 8 9 10 1 1 2 3 4 12 1 13 14 1 15 16 1 17 18 1 1 1 19 1 2 20 3 1
More informationHA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル
P1E1M01500-3 - - - LSI MegaRAID SAS-MFI BIOS Version x.xx.xx (Build xxxx xx, xxxx) Copyright (c) xxxx LSI Corporation HA -0 (Bus xx Dev
More information1 124
7 1 2 3 4 5 6 7 8 9 10 11 12 1 124 Phoenix - AwardBIOS CMOS Setup Utility Integrated Peripherals On-Chip Primary PCI IDE [Enabled] IDE Primary Master PIO [Auto] IDE Primary Slave PIO [Auto] IDE Primary
More informationExpress5800/320Lc/320Lc-Rユーザーズガイド(セットアップ編)
3 B 1 2 Phoenix BIOS S etup Utility Main Advanced Security System Hardare Boot Exit Processor Type : Processor Speed : Cache RAM : System Memory : Extended Memory : Intel (R) Xeon (TM) processor 2.80
More informationEQUIUM EQUIUM S5010 1
EQUIUM EQUIUM S5010 1 1 1 2 3 4 2 1 2 3 2 3 1 2 3 4 5 6 7 4 1 2 5 1 2 6 1 7 1 2 3 4 5 6 7 1 2 3 4 5 6 3 7 8 9 1 2 3 4 4 5 6 7 8 1 1 2 3 4 10 1 11 12 1 13 14 1 15 16 1 1 2 3 17 1 2 3 18 4 5 6 1 19 1 2 3
More information5 1 2 3 4 5 6 7 8 9 10 11 12 1 132 CMOS Setup Utility - Copyright (C) 1984-2000 Award Software Power Management Setup ACPI Suspend Type S3 (STR) Power Management User Define Video Off Method DPMS Video
More information5 1 2 3 4 5 6 7 8 9 10 1 Quick Boot 1st Boot Device 2nd Boot Device 3rd Boot Device Network Boot Initial Display Mode S.M.A.R.T. for Hard Disks BootUp Num-Lock Password Check CPU Serial Number System BIOS
More information94
4 1 2 3 4 5 6 7 8 9 10 11 12 94 4 95 1 2 3 4 96 5 5 4 97 98 1 2 3 4 99 4 100 5 6 1 2 4 101 1 2 3 4 5 1 2 3 4 102 1 2 3 4 4 103 1 2 104 1 2 3 4 4 5 105 1 2 106 4 107 108 1 2 3 4 4 109 1 2 3 4 110 1 2 3
More information橡EN1165.PDF
G780(7ZMMP-KK F1C) BIOS Setup 1 G780(7ZMMP-KK F1C) 2 G780(7ZMMP-KK F1C) 3 G780(7ZMMP-KK F1C) 4 G780(7ZMMP-KK F1C) 1st Boot Device 2nd Boot Device 3rd Boot Device S.M.A.R.T. for Hard Disks BootUp Num-Lock
More informationHPCクラスタ専用サーバ T220Rd-1ユーザーズガイド
3 Press DEL run Setup (F4 on Remote Keyboard) Enter CURRENT Passord:[ ] Boot Security Exit USB Configuration Module Version - 2.24.0-11.4 Enables USB host controllers. USB Devices Enabled : 1 Keyboard,
More informationC
(1) (2) Play Volume (3) (4) (5) (6) (7) (8) Ctrl N Ctrl Ctrl (9) (10) OFF (11) (12) OFF (13) (14) 2 3 4 5 6 7 LCD LCD 8 TV ANT. S IN VIDEO IN LINE-L IN LINE-R IN 9 10 11 12 LCD LCD 13 LCD 14 LCD 15 LCD
More informationFLORA bd500 ユーザーズガイド 500X7
FB50071000-7 制限 補足 xvii 安全にお使いいただくために 続き 警告ラベルは次に示す箇所に貼り付けられています FLORA bd を取り扱う前に 警告ラベルが貼り付けられていること および警告ラベルの内容をご確認く ださい もし警告ラベルが貼り付けられていなかったり はがれやかすれなどで読みづらかったりする場合 は お買い求め先にご連絡いただくか 保守員をお呼びください
More informationUS40cユーザーズガイド
US40c 1 Enter CURRENT Passord:? _ InsydeH20 Setup Utility Main Advanced Security Boot Exit Video Configuration Poer Save Quick Charge HDD [2GB ATA Flash
More information1 144
5 1 2 3 4 5 6 7 8 9 10 11 12 1 144 AMIBIOS SETUP - POWER MANAGEMENT SETUP (C)1999 American Megatrends, Inc. All Rights Reserved ACPI Standby State Power Management/APM Video Power Down Mode Hard Disk Power
More informationExpress5800/180Rb-7
w w w w Press to enter SETUP or Press Enter password:[ ] Pheonix Phoenix BIOS Setup Utility Main Advanced Security Server Boot Exit BIOS Release : BIOS Version : System Time : System Date : Legacy
More information本機をお使いの方へ
MA46H/S Windows 98 / NT 4.0 Windows 98 / NT 4.0 MA46H/S BIOS 1999 10 808-877675-132-A 3 AT 6. 1. BIOS P.7 1. Windows 98 Windows Windows 98 Microsoft Windows 98 Windows NT 4.0 Microsoft Windows NT Workstation
More informationHA8000シリーズ ユーザーズガイド 〜BIOS編〜 HA8000/RS440 2012年11月〜モデル
R44BL21500-2 Save & reset Save configuration and reset? Yes No Aptio Setup Utility - Copyright (C) 20xx American Megatrends, Inc. Main Advanced Security Server Management Boot Option
More informationiExpress5800/N サーバハードウェア
Press F2 to enter SETUP/Q-Flash Main A Date (mm:dd:yy) Time (hh:mm:ss) >IDE Primary Master IDE HDD Auto-Detection Press Enter Write Cache Disabled Enabled IDE Primary Master Auto None Manual Access
More information1 2
1 1 2 1 2 3 4 5 3 2 3 4 4 1 2 3 4 5 5 5 6 7 8 1 1 2 1 10 1 3 1 11 2 12 2 3 1 13 2 14 2 3 1 15 2 16 2 3 1 17 2 1 2 3 4 5 18 2 6 7 8 3 1 1 2 19 2 20 2 3 1 21 2 22 2 3 1 23 2 24 2 3 1 25 2 26 2 3 1 27 2 28
More informationExpress5800/R110a-1Hユーザーズガイド
4 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Xeon Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0B60: DIMM group #1 has been disabled. : Press to resume, to
More information5 1 2 3 4 5 6 7 8 9 10 11 12 1 146 CMOS Setup Utility - Copyright (C) 1984-2000 Award Software Power Management Setup ACPI Suspend Type S3 (STR) Power Management User Define Video Off Method DPMS Video
More informationExpress5800/320Fa-L/320Fa-LR
7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup
More informationExpress5800/120Mf ユーザーズガイド
2 1 2 1 2 3 2 1 321 321 321 AC1 AC2 AC1 AC2 ACR 1 2 2 OUTPUT (UNSWITCH OUT) OUTPUT(SWITCH OUT) AC100V 50/50HZ TOTAL 12.5A Press to enter SETUP Press for SCSISelect(TM) Utility!
More information1 2
1 1 2 3 1 2 3 4 5 2 3 4 4 1 2 3 4 5 5 5 6 1 1 2 3 1 8 1 3 1 9 2 10 2 3 1 11 2 12 13 3 1 2 2 14 2 3 1 15 2 16 2 3 1 17 2 18 2 3 1 19 3 20 3 3 1 21 3 22 3 3 1 23 3 24 3 3 1 25 3 26 3 3 1 27 3 28 3 3 1 29
More informationBIOSセットアップメニュー 一覧
B6FH-A602-01 Z0-00 ESPRIMO B532/G BIOS セットアップメニュー一覧 各製品名は 各社の商標 または登録商標です 各製品は 各社の著作物です その他のすべての商標は それぞれの所有者に帰属します Copyright FUJITSU LIMITED 2013 BIOS セットアップメニュー詳細 BIOS セットアップのメニューについて説明しています BIOS セットアップのメニューは次のとおりです
More information1 2
1 1 2 1 2 3 4 5 3 2 3 4 4 1 2 3 4 5 5 5 6 1 1 2 1 8 1 3 1 9 2 10 2 3 1 11 2 12 2 3 1 13 14 2 2 3 1 15 2 1 2 3 4 5 16 2 6 7 8 3 1 1 2 17 2 18 2 3 1 19 2 20 2 3 1 21 2 22 2 3 1 23 2 24 2 3 1 25 2 26 2 3
More informationN Express5800/R320a-E4 N Express5800/R320a-M4 ユーザーズガイド
7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup
More informationExpress5800/R320a-E4, Express5800/R320b-M4ユーザーズガイド
7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup
More informationBMC Configuration ユーザーズガイド
BMC Configuration 1 2 3 4 5 Rev.1.01 NEC Corporation 2011 1 BMC Configuration... 1... 2... 3... 4... 5 1... 6 1.1 BMC Configuration... 6 2... 7 2.1... 7 2.2... 8 3... 9 3.1 BMC Configuration (Windows)...
More informationRAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( (
RAID RAID 0 RAID 1 RAID 5 RAID 10 2 2 3 4 * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( ( 3) 2 ) Windows USB 1 SATA A. SATA SATA Intel SATA
More informationMvk-xf6k.pm6
1 2 3 MVK-XF6K 25 1 2 26 MVK-XF6K 3 MVK-XF6K 27 1 2 3 4 28 MVK-XF6K 1 2 3 4 MVK-XF6K 29 1 2 30 MVK-XF6K 1 2 MVK-XF6K 31 1 2 32 MVK-XF6K 3 4 MVK-XF6K 33 MEMO STANDARD COMS SETUP BIOS FEATURES SETUP BIOS
More informationExpress5800/320Fa-L/320Fa-LR/320Fa-M/320Fa-MR
7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup
More informationRAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS RAID D. RAID/AHCI 2 SATA SSD ( 1) ( ( 3) 2
RAID SATA... 2 RAID/AHCI... 16 Intel Optane... 19 Intel Virtual RAID on CPU Intel VROC... 21 RAID RAID 0 RAID 1 RAID 5 RAID 10 2 2 3 4 * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS
More informationBMC Configuration ユーザーズガイド
BMC Configuration 1 2 3 4 5 Rev.1.10 NEC Corporation 2012 1 BMC Configuration... 1... 2... 4... 5... 6 1.... 7 1.1 BMC Configuration... 7 2.... 8 2.1... 8 2.2... 9 3.... 10 3.1 BMC Configuration (Windows)...
More informationMF02_BIOS_R00.xls
Information Menu ( 情 報 メニュー) Information Menu CPU Type System Memory Extended Memory HDD Serial Number System BIOS Version VGA BIOS Version KBC Version Serial Number Asset Tag Number Product Name Manufacturer
More informationPRIMERGY RX300 S7 環境設定シート ハードウェア編
PRIMERGY RX300 S7 CA92344-0147-02 環境設定シート - ハードウェア編 - 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです
More informationMicrosoft Word - DS50-D B_S711_BIOS_Manual.doc
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため
More informationServer Configuration Utility ユーザーズガイド
Express5800 Server Configuration Utility 1 2 3 4 5 Rev.1.00 NEC Corporation 2014 1 Server Configuration Utility... 1... 2... 4... 5... 6 1.... 7 1.1 Server Configuration Utility... 7 2.... 8 2.1... 8 2.2...
More informationBIOS 設定書 BIOS 出荷時設定 BIOS 設定を工場出荷状態に戻す必要がある場合は 本書の手順に従って作業をおこなってください BIOS 設定を変更されていない場合は 本書の作業は必要ありません BIOS 出荷時設定は以下の手順でおこないます スタート A) BIOS の Setup Uti
BIOS 出荷時設定 BIOS 設定を工場出荷状態に戻す必要がある場合は 本書の手順に従って作業をおこなってください BIOS 設定を変更されていない場合は 本書の作業は必要ありません BIOS 出荷時設定は以下の手順でおこないます スタート A) BIOS の Setup Utility を起動 B) BIOS 設定をデフォルトに戻す C) 工場出荷時状態に再設定 D) 設定状態をセーブして終了
More informationExpress5800/320Fc-MR
7 7 Phoenix BIOS 4.0 Release 6.0.XXXX : CPU=Pentium III Processor XXX MHz 0640K System RAM Passed 0127M Extended RAM Passed WARNING 0212: Keybord Controller Failed. : Press to resume, to setup
More informationPC STATION E Series BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認したり 変更するためのプログラムです セットアッププログラムは マザーボード上のフラッシュメモリに格納されているた
PC STATION E Series BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認したり 変更するためのプログラムです セットアッププログラムは マザーボード上のフラッシュメモリに格納されているため いつでも実行できます BIOS セットアッププログラムで定義する設定情報は CMOS RAM と呼ばれる特殊な領域のメモリに格納されています
More informationExpress5800/R320a-E4/Express5800/R320b-M4ユーザーズガイド
7 7 障害箇所の切り分け 万一 障害が発生した場合は ESMPRO/ServerManagerを使って障害の発生箇所を確認し 障害がハー ドウェアによるものかソフトウェアによるものかを判断します 障害発生個所や内容の確認ができたら 故障した部品の交換やシステム復旧などの処置を行います 障害がハードウェア要因によるものかソフトウェア要因によるものかを判断するには E S M P R O / ServerManagerが便利です
More informationPRIMERGY TX100 S3 環境設定シート
PRIMERGY TX100 S3 ( 型名 :PYT103 ) CA92344-0072-04 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです
More informationServer Configuration Utility ユーザーズガイド
Server Configuration Utility 1 2 3 4 5 80.109.01-022.01 2016 3 NEC Corporation 2016 1 ... 1... 2... 4... 5... 6 1.... 7 1.1 Server Configuration Utility... 7 2.... 8 2.1... 8 2.2... 8 2.3... 9 3.... 10
More informationBMC Configuration ユーザーズガイド
BMC Configuration 1 2 3 4 5 Rev.1.00N NEC Corporation 2014 1 ... 1... 2... 4... 5... 6 1.... 7 1.1 BMC Configuration... 7 2.... 8 2.1... 8 2.2... 8 2.3... 9 3.... 10 3.1 BMC Configuration (Windows)...
More informationPRIMERGY TX1310 M1 環境設定シート
PRIMERGY TX1310 M1 CA92344-0497-01 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方本文中の製品名称を
More informationMicrosoft Word - DS50-D A_S501B_BIOS_Manual.doc
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納されています この設定情報は マザーボードに搭載されているバッテリによって保存されているため
More informationMicrosoft Word - DS50-D A_E701_BIOS_Manual.doc
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため
More informationRF2_BIOS一覧
Main Main Menu System Time System Date hh:mm:ss( 時 :00~23/ 分 :00~59/ 秒 :00~59) www mm/dd/yyyy ( 曜日 : 自動設定 / 月 :01~12/ 日 :01~31/ 年 :1980~2099) Advanced Internal Pointing Device Enabled Enabled/Disabled
More informationPRIMERGY ECONEL 100 S2 環境設定シート
Microsoft Windows Windows Server Microsoft Corporation Xeon Pentium Celeron Core 2 Duo Intel Corporation 3.5 1 2 3 4 3.5 ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160 GB ( ) 500 GB ( ) 80GB ( ) 160
More informationPRIMERGY MX130 S2 環境設定シート
PRIMERGY MX130 S2 ( 型名 :PYM132 ) CA92344-0090-02 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです
More information7 7
7 7 w w AmbientTempAlm00 AmbientTempAlm02 AmbientTempAlm07 AmbientTempAlm09 BMC Unsync BMC0 Not Ready BMC1 Not Ready Cor0 +12vAlm 00 Cor0 +12vAlm 02 Cor0 +12vAlm 07 Cor0 +12vAlm 09 Cor0 +2.5vAlm 00 Cor0
More informationPRIMERGY TX100 S3 環境設定シート
PRIMERGY TX100 S3 ( 型名 :PYT103 ) CA92344-0072-05 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです
More informationb7fh pdf
PRIMERGY TX0FT S4 環境設定シート 本書の読み方 A コンフィグレーション本サーバにおけるハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX0FT S4 本文中の表記 本サーバ またはサーバ 商標 各製品名は
More informationMicrosoft Word - DS50-D A_SX505_BIOS_Manual.doc
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は COMS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため
More informationPRIMERGY MX130 S2 環境設定シート
PRIMERGY MX130 S2 CA92344-0090-03 環境設定シート 本書の構成 A ハードウェア構成シート本サーバにおけるハードウェアの構成を記録しておきます B C D BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティのを記録しておきます デザインシート (Windows) ソフトウェアの設定を記録しておきます 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです
More informationPromise FastTrak100 Japanese Manual
PROMISE TECHNOLOGY, INC. FastTrak100 TX/LP Series Ultra ATA/100 RAID Cards Japanese User s Manual October 5, 2001 TX/LP Series Ultra ATA/100 RAID Cards 0. 0.... 1 1.... 2 2.... 2... 3... 4 3.... 5...
More informationMicrosoft Word - DS50-D A_S505A_BIOS_Manual.doc
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリに格納されています このユーティリティで定義されている設定情報は CMOS RAM と呼ばれる特殊な領域に格納され ています この設定情報は マザーボードに搭載されているバッテリによって保存されているため
More informationPAシリーズBIOSマニュアル
************************************************** KOHJINSHA PA シリーズ BIOS 設定プログラム説明書 ************************************************** --- 注意事項 --- BIOS 設定を間違うと 深刻なトラブルを引き起こすことがあります 内容を変更する際はご注意いただくとともに
More informationPRIMEQUEST 2000シリーズ コンバージドネットワークアダプタ 環境設定シート(Legacy ROM)
PRIMEQUEST2000 シリーズ CA92344-1108-02 デュアルチャネルコンバージドネットワークアダプタ (10Gbps) (MC-0JCE61,MC-0JCE62) シングルチャネルコンバージドネットワークアダプタ (40Gbps) (MC-0JCE91,MC-0JCE92) 環境設定シート (Legacy ROM) - ハードウェア編 - 本書の構成 A. B. C. D. E.
More informationExpress5800/InternetStreamingServer LS
5 Press DEL to enter SETUP Phoenix - Aard WorkstationBIOS CMOS Setup Utility Standard CMOS Features Advanced BIOS Features Advanced Chipset Features Integrated Peripherals Poer Management Setup PnP/PCI
More information環境設定シート
PRIMERGY TX0FT S2 環境設定シート 本書の読み方 A コンフィグレーションシート本サーバにおけるハードウェアの構成と各種セットアップのを記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX0FT S2 本文中の表記 本サーバ またはサーバ 商標 インテル
More informationHP Server tc2120 Microsoft Windows 2000 Server SP3 HP P
HP Server tc2120 Microsoft Windows 2000 ServerSP3 HP P312977-191 200210 Hewlett-Packard Company Hewlett- Packard Company Hewlett-Packard Company Intel Corporation MicrosoftMS-DOSWindows Windows NT Microsoft
More informationWinPC
PC 4 6 BIOS PC PC 6 10 14 OS BIOS BIOS Windows 7 18 22 26 Windows Update BIOS 30 BIOS BIOS 30 34 ASUSTeK Computer ASRock 38 42 GIGABYTE TECHNOLOGY MSI 46 46 58 50 54 62 Win7 Ubuntu A B BCD Windows XP bootmgr
More informationExpress5800/51Eb, Y51Eb ユーザーズガイド
NEC Express Express5800 Express5800/51Eb, Y51Eb 1 2 3 4 50.017.02-001.01 2012 4 NEC Corporation 2012 ( )EXPRESSBUILDER ( ) ( ) PDF EXPRESSBUILDER PDF 1 2 3 BIOS EXPRESSBUILDER 4 PDF Windows 1 Windows Windows
More informationBIOSマニュアル
BIOS マニュアル BIOSセットアップユーティリティーとは BIOS セットアップユーティリティーとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティーは 本体に内蔵されているマザーボード上のフラッシュメモリーに格納されています このユーティリティーで定義されている設定情報は CMOS RAM と呼ばれる特殊な領域に格納されています この設定情報は マザーボードに搭載されているバッテリーによって保存されているため
More informationNorthern Lights Server
FirstStep Guide Northern Lights Server Intel Management Module (Advanced Module / ISM 8.4) 2 www.nlcomputer.com 1 FirstStep Guide 1.1. INTEL MANAGEMENT MODULE 2... 5 1.2.... 9 1.3.... 10 2.1. BMC...11
More informationRTX830 取扱説明書
RTX830 JA 1 2 3 4 5 6 7 8 9 10 11 external-memory performance-test go 12 13 show config 14 15 16 17 18 19 20 save 21 22 23 24 25 26 27 save RTX830 BootROM Ver. 1.00 Copyright (c) 2017 Yamaha Corporation.
More information2
WJ-HD150 Digital Disk Recorder WJ-HD150 2 3 q w e r t y u 4 5 6 7 8 9 10 11 12 13 14 15 16 q w SIGNAL GND AC IN 17 SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY DAILY Program 1 Event No.1 Event
More information[DS50-N A] BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリーに格納されています このユ
BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリーに格納されています このユーティリティで定義される設定情報は チップセット上の CMOS RAM と呼ばれる特殊な領域に格納 されます この設定情報は マザーボードに搭載されているバックアップ電池により保存されます
More informationWinBook WV BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認 変更するためのプログラムです 本機では AMI BIOS を使用しています セットアッププログラムは マザーボード上のフラッシュメ
WinBook WV BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認 変更するためのプログラムです 本機では AMI BIOS を使用しています セットアッププログラムは マザーボード上のフラッシュメモリに格納されており パソコンの起動時いつでも実行できます BIOS セットアッププログラムで定義する設定情報は
More informationPRIMERGY 環境設定シート
FUJITSU Server PRIMERGY CA92344-0887-04 Dual port LAN カード (10GBASE) (PY-LA3B2, PYBLA3B2, PYBLA3B2L) 環境設定シート - ハードウェア編 - 本書の構成 A. B. C.-D. E. F. BIOS セットアップユーティリティ設定シート本サーバにおける BIOS セットアップユーティリティの Option
More informationo4hd200j.pdf
WJ-HD200 1 2 3 4 5 6 7 8 Digital Disk Recorder WJ-HD200 2 3 4 5 6 O O O O O O 7 O 8 9 10 11 12 13 q w 14 15 SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY DAILY Program 1 Event No.1 Event No.2
More information環境設定シート
IntelXeon Intel Corporation 3.5 1 2 3 4 5 3.5 10,000rpm 15,000rpm ( ) 73.4GB ( ) 146.8GB ( ) 300GB ( ) 73.4GB ( ) 146.8GB ( ) 73.4GB ( ) 146.8GB ( ) 300GB ( ) 73.4GB ( ) 146.8GB ( ) 73.4GB ( ) 146.8GB
More information環境設定シート
PRIMERGY TX200 S2 環境設定シート 本書の読み方 A コンフィグレーション本サーバにおけるハードウェアの構成と各種セットアップの設定値を記録しておきます B 障害連絡シート障害が発生した場合にサーバの状態を記入しておくシートです 製品の呼び方 本文中の製品名称を 次のように略して表記します 製品名称 PRIMERGY TX200 S2 Microsoft Windows Server
More informationMagic Guard DVR Модель 3
Magic Guard DVR 2 4 !" ------------------------------ 2 ---------------------------------------------------3 ------------------------------------------------------4 DVR: ""#------------5 DVR: - ""#---------------5
More information