3
w w w w w
Press <F2> to enter SETUP Enter password [ ]
Main System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Power ON Delay Time: Platform Event Filtering: PhoenixBIOS Setup Utility Advanced Security Server Boot Exit [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to view server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
w w w w w w
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit System Time: System Date: Hard Disk Pre-Delay: SATA Port 0 SATA port 1 SATA Port 2 SATA Port 3 [14:18:58] [10/04/2007] [Disabled] [250GB SATA0] [250GB SATA1] [None] [None] Item Specific Help <Tab>, <Shift-Tab>, or <Enter> selects field. Processor Settings Language: [English] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit ç ñ
w w w Main PhoenixBIOS Setup Utility Processor Settings Item Specific Help Processor Retest: Processor Speed Setting: Processor 1 CPUID: Processor 1 L2 Cache: [No] 2530 MHz 0001067A 6144 KB Select 'Yes', BIOS will clear historical processor status and retest all processors on next boot. Active Processor Cores: Execute Disable Bit: Intel SpeedStep(R) Technology: C1 Enhanced Mode: Virtualization Technology: Hardware Prefetcher: Adjacent Cache Line Prefetch: [All] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Item Specific Help Memory Configuration PCI Configuration Peripheral Configuraion Advanced Chipset Control Additional setup menus to configure Memory devices. Boot-time Diagnostic Screen: Reset Configuration Data: NumLock: Memory/Processor Error: [Disabled] [No] [Off] [Boot] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Memory Configuration Item Specific Help Installed memory: Available under 4GB: DIMM #1 Status: DIMM #2 Status: DIMM #3 Status: DIMM #4 Status: Memory Retest: Extended RAM Step: 16384 MB 3328 MB Normal Normal Normal Normal [No] [Disabled] Enables DIMM sparing feature. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility PCI Configuration Item Specific Help Onboard Video Controller Onboard LAN 1 Onboard LAN 2 PCI Slot 1 Option ROM: [Enabled] Additional setup menus to configure onboard Video controller. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port B: Base I/O address: Interrupt: USB Controller: USB 2.0 Controller: Serial ATA: Native Mode Option: SATA Controller Mode Option: SATA AHCI: SATA RAID: [Enabled] [2F8h] [IRQ 3] [Enabled] [Enabled] [Enabled] [Serial ATA] [Enhanced] [Enabled] [Disabled] Configure Serial Port using options: [Disabled] No configuration [Enabled] User configuration F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Advanced Chipset Control Item Specific Help Multimedia Timer: Intel (R) I/O AT: Wake On LAN/PME: Wake On Ring: Wake On RTC Alarm: [Enabled] [Enabled] [Enabled] [Disabled] [Disabled] Enable/Disable Multimedia Timer (HPET). F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Main Advanced PhoenixBIOS Setup Utility Security Server Boot Exit Supervisor Password Is: User Password Is: Set Supervisor Password Set User Password Clear Clear [Enter] [Enter] Item Specific Help Supervisor Password controls access to the setup utility. Password on boot: Fixed disk boot sector: Power Switch Inhibit: [Disabled] [Normal] [Disabled] Disable USB Ports: [Disabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit w w w
Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Power ON Delay Time: Platform Event Filtering: [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to view server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server System Management Item Specific Help BIOS Revision: Board Part Number: Board Serial Number: System Part Number: System Serial Number: Chassis Part Number: Chassis Serial Number: Onboard LAN1 MAC Address: Onboard LAN2 MAC Address: Management LAN MAC Address: BMC Device ID: BMC Device Revision: BMC Firmware Revision: SDR Revision: xxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx 01 01 01.00 01.00 All items on this meenu cannot be modified in user mode. If any items require changes, please consult your system Supervisor. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server Console Redirection Item Specific Help BIOS Redirection Port: Baud Rate: Flow Control: Terminal Type: Continue Redirection after POST: Remote Console Reset: [Disabled] [19.2K] [CTS/RTS] [VT100+] [Enabled] [Disabled] Selects the Serial port to use for Console Redirection. Disabled completely disables Console Redirection. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server BMC LAN Configuration Item Specific Help LAN Connection Type: IP Address: IP Subnet Mask: Default Gateway: DHCP: [Auto Negotiation] [192.168.001.001] [255.255.255.000] [000.000.000.000] [Disabled] Display IP Address. Web Interface HTTP: HTTP Port Number: HTTPS: HTTPS Port Number: [Disabled] [ 80] [Disabled] [ 443] Command Line Interface Telnet: Telnet Port Number: [Disabled] [ 23] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
w w
PhoenixBIOS Setup Utility Server System Event Log Event Log Configuration Setup Notice If you select "System Event Log" menu below, it may take a few minutes to display. Item Specific Help Display the System Event Log Auto Clear Event Logs: Clear All Event Logs: [Disabled] [Enter] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server System Event Log Item Specific Help SEL Entry Number = SEL Record ID = SEL Record Type = Timestamp = Generator ID = SEL Message Rev = Sensor Type = Sensor Number = SEL Event Type = Event Description = SEL Event Data = 1/121 0904 02 - System Event Record 2007/08/05 10:58:28 20 00 04 12 - System Event 87 - System Event 6F - Sensor specific OEM System Boot Event 41 8F FF This is an entry The System Event Log. Eyes used to view. Up arrow :Newer SEL Down arrow :Older SEL <->:Newer SEL <+>:Older SEL Home:Newer SEL End :Older SEL F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Boot priority order: 1: USB CDROM: GENERIC DVD-ROM B763B 2: IDE CD: 3: USB FDC: 4: USB KEY: 5: IDE HDD: 6: USB HDD: 7: PCI SCSI: P0-WDC WD800BLFS-19YBU0 8: PCI BEV: IBA GE Slot 0100 v1322 Excluded from boot order: : PCI BEV: IBA GE Slot 00CB v1250 Item Specific Help Keys used to view or configure devices: Up and Down arrows select a device. <+> and <-> moves the device up or down. <x> exclude or include the device to boot. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit Exit Saving Changes Exit Discarding Changes Load Setup Defaults Load Custom Defaults Save Custom Defaults Disacard Changes Save Changes [Enter] [Enter] Item Specific Help Exit System Setup and save your changes to CMOS. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Execute Command F10 Save and Exit
w w
w w w w w w w w w w
w w
w w w
w w w w w w w
LSI Software RAID Configuration Utility Ver xxx Management Menu Configure Initialize Objects Rebuild Check Consistency Configure Logical Drive(s) Use cursor keys to navigate between items and Press ENTER to select an option
w w
A-0 SPAN-1 Select Configurable Array(s)
Virtual Drives Configured LD 0 RAID 1 Size xxxmb #Stripes 2 StrpSz 64KB Status ONLINE Virtual Drive0 RAID = 1 Size = xxxxmb DWC = On RA = On Accept Span = NO
w w
w w
w w