BGI PDF

Similar documents
HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル

HA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2

fx-9860G Manager PLUS_J

NSR-500 Installation Guide

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

橡P3FY PDF

NSR-500 Software Update Installation Procedures

Microsoft Word - Win-Outlook.docx

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( (

橡P3FY-A015-01_A.PDF

NSR-500 Create DVD Installer Procedures

Promise FastTrak100 Japanese Manual


Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

P3FY J E

はじめに SCSI ( ) RAID Utility (HDD Check Scheduler) V1.01 / 2005 年 4 月富士通株式会社 Microsoft Windows Windows NT Microsoft Corporation All Rights Reserved, Cop

LC304_manual.ai

MIDI_IO.book

1 138

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS RAID D. RAID/AHCI 2 SATA SSD ( 1) ( ( 3) 2

BS・110度CSデジタルハイビジョンチューナー P-TU1000JS取扱説明書

US40cユーザーズガイド

P3FY-A JP.PDF

取扱説明書_KX-PW100CL

Express5800/R110a-1Hユーザーズガイド

2 3

2 3

C H H H C H H H C C CUTION:These telephones are for use in Japan only. They cannot be used in other countries because of differences in voltages, tele

取説_VE-PV11L(応用編)

H8000操作編

Express5800/320Fc-MR

MOTIF XF 取扱説明書

i5 Catalyst Case Instructions JP

elemmay09.pub

0 C C C C C C C

取説_KX-PW101CL_PW102CW

137. Tenancy specific information (a) Amount of deposit paid. (insert amount of deposit paid; in the case of a joint tenancy it should be the total am

Z7000操作編_本文.indb


% + RP-BC30 BATTERY CHARGER STAND K -! # % $ $ % % # $ $ $ %

NSR-500 Create USB Installer Procedures

VE-GP32DL_DW_ZA

;y ;y ;; yy ;y;; yy y;y;y;y ;y; ;; yy ; y Portable CD player Operating Instructions RQT5364-S

2

2

2

GP05取説.indb

Express5800/R320a-E4/Express5800/R320b-M4ユーザーズガイド

00-COVER.P65

Rev.2 N 内蔵 RDX N 外付 RDX ファームウェアアップデート手順 RDX 装置をお買い上げいただきましてありがとうございます 本書は N 内蔵 RDX N 外付 RDX のファームウェアアップデート手順を記載しています 1. 概要


2

取説_KX-PW38CL_PW48CL

- 1 -

Actual ESS Adapterの使用について

入学検定料支払方法の案内 1. 入学検定料支払い用ページにアクセス ポータルの入学検定料支払いフォームから 入学検定料支払い用 URL の ここをクリック / Click here をクリックしてください クリックを行うと 入学検定料支払い用のページが新たに開かれます ( 検定料支払い用ページは ポ


Microsoft Word - D JP.docx

*Ł\”ƒ‚ä(DCH800)

1 2

HP Server tc2120 Microsoft Windows 2000 Server SP3 HP P

RR-US470 (RQCA1588).indd

N manual_JP.PDF

V-SFTのインストール及び画面データの転送手順 V-SFT Installation and Screen Data Transfer Procedure

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi


1 124

Microsoft PowerPoint - Ritsu-Mate出願操作マニュアル(学部英語版) _STEP4.pptx

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

TOOLS for UR44 Release Notes for Windows

MINAS取説アブソ警告クリア方法記載ミス_モータニュース…

Microsoft Word - KUINS-Air_W10_ docx

PFQX2227_ZA

+ -



Fortigate Ver.4.0MR3Patch12 Information 1

VE-GD21DL_DW_ZB

FortiGate Ver.4.0MR3Patch14 Information 1

Huawei G6-L22 QSG-V100R001_02

0 C C C C C C

1 122

Page 1 of 6 B (The World of Mathematics) November 20, 2006 Final Exam 2006 Division: ID#: Name: 1. p, q, r (Let p, q, r are propositions. ) (10pts) (a

Microsoft Word - PCM TL-Ed.4.4(特定電気用品適合性検査申込のご案内)

手動操作によるパーティション作成方法 4. リストア方法 (3) システム情報の復元 の 3-2) の手順で sfdisk コマンドによるシステムのパーティション情報の復元に失敗する場合は fdisk コマンドにて手動でパーティションを作成してください 作成するパーティションのサイズは バックアップ

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part


untitled

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part


取扱説明書の読み替え一覧表

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

Diskette Drive Installation

Microsoft Word - KUINS-Air_W8.1_ docx

Diskette Drive Installation

EQUIUM EQUIUM 1

*Ł\”ƒ‚ä(CV03)


How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

Transcription:

1999 11 SCSI ( ) (DACCF ) ( ) SCSI (GP5-143/144/145/146)

1. DACCF DACCF ( 3.4 ) OS I/O DACCF ( ) BIOS BIOS OS RAID

DACCF DACCF 1GB 9GB 3 18GB 9GB (3-1) 126 ( 7 /GB 18GB) [DACCF ] RAID 2 3 3 8 8 RAID1 RAID6 RAID6 1GB 10 /GB 7 /GB 14 /GB 5 /GB 10 /GB

2. I/O DACCF DACCF ( ) BIOS BIOS OS RAID LED LED OS ( 3.8.3 Format Drive ) DACCF

2.1 DACCF [ ] GP5-143 V4.06-0-64 V4.07-0-08 GP5-144 V5.06-0-64 V5.06-0-70 V5.07-0-08 GP5-145 V5.07-0-08 GP5-146 V5.07-0-08 (OS ) DACxxxxx Firmware Version x.xx-x-xx 2.2 ( ) (FDISK ) OS OS OS (OS ) OS

2.3 Windows NT 1. OS ( ) 2. LED NetWare OS 1. Server Wizard CD-ROM CD-ROM 2. [Ctrl]+[Alt]+[Delete] ( ) 3. CD-ROM BOOT MS-DOS V6.2 Startup MENU 3.Basic(DACCFG) MS-DOS 4. A: > 5. LED 2.4 Windows NT 1. RAID HDD 2. CWNRAID1 3. Consistency Check Completed Successfully. (2560/ ) No Consistency Check started. System Drive #x, #y have not been optimized yet.(3105/ )

NetWare OS 1. DACCF (Consistency Check) 2. 3. System drive found to be Consistent. Press any key to continue. 4. Cannot check consistency of a non-redundant or uninitialized System drive. 2.5 I/O 1GB 9GB 3 18GB 9GB (3-1) 108 ( 6 /GB 18GB) I/O [ ( I/O )] RAID 2 3 3 8 8 RAID1 RAID6 RAID6 1GB 8 /GB 6 /GB 10 /GB 3 /GB 10 /GB

2.6 I/O I/O DACCF ( ) DACCF

(Addendum guide for the RAID Card GP5-143/144/145/146) November, 1999 Fujitsu Limited A System Drive which is configured under RAID Card must be initialized so that it can be used in the best performance. RAID Card has two types of initializations. One is foreground initialization by DACCF which is done immediately after the RAID configuration is set. Another one is background initialization which is done during normal I/O of a host system in parallel. This guide shows summaries and notes for using each initializations.

1. DACCF Initialization This is a way to initialize System Drive by DACCF continuously after RAID configurations are set by the same utility. Refer to 3.4 Initializing System Drive for more details of DACCF initialization. The best performance will be provided from the beginning of OS setup. Flow of DACCF Initialization (OS installation) RAID Card Installation Refer to instructions of the server and install the RAID Card. BIOS Setting Refer to instructions of attached guide and set the BIOS properly. RAID Configuration Set Physical Packs and System Drive by DACCF. DACCF Initialization Initialize the System Drive by DACCF. OS Installation Refer to instructions of attached guide and install OS. RAID Admin Tools installation Refer to instructions of attached guide and install RAID Administration Tools.

Amount of time is needed for DACCF initialization before OS setup so that write process for all area of System Drive will be executed by DACCF. The following table shows the time required to carry out DACCF initialization per 1 GB. For example, the time required for DACCF initialization of the RAID 5 System Drive that is composed of three 9 GB hard disks is 126 minutes approximately (= 7min/GB * 18 GB), for the total capacity of the System Drive is 18 GB (= 9GB * [3-1]). Use it as rule of thumb because the time depends on the RAID configurations and the type of hard disk drives. [Approximate execution time of DACCF initialization] Number of HDD RAID Level Execution time / 1GB 2 3 3 8 8 RAID1 RAID6 RAID6 10 min./gb 7 min./gb 14 min./gb 5 min./gb 10 min./gb

2. Background Initialization (BGI) Background Initialization (hereinafter simply called BGI) is a way to initialize (optimize) System Drive in usual operation hours in parallel. If the DACCF initialization was not executed or it was canceled, BGI is executed automatically. Flow of BGI (OS installation) RAID Card Installation Refer to instructions of the server and install RAID Card. BIOS Settings Refer to instructions of attached guide and set the BIOS propely. RAID Configuration Set Physical Pack and System Drive by DACCF. OS Installation Refer to instructions of attached guide and install OS BGI RAID Admin Tools Installation Refer to attached guide and install RAID Administration Tools. BGI is started automatically on the first write of the host system. Any special operations to start BGI are not needed. If the power supply of the server or HDD cabinets were switched off during the BGI process, there is a possibility hard disk drives break down. Pay attention to access LED of hard disk drives and do not cut the power supply when the one or more LED are lighting. A used hard disk drive, which has any data including partition information on itself, must be formatted before it can be used for RAID configurations. To format hard disk drives, refer to 3.8.3 Format Drive. The amount of time for the DACCF initialization can be saved by using BGI. Following describes notes for using the BGI.

2.1 BGI Supported Firmware Version BGI was supported by following firmware versions. DACCF initialization is essential for the RAID Card which does not have BGI supported firmware. [BGI supported firmware] Unsupported Supported GP5-143 V4.06-0-64 V4.07-0-08 or later GP5-144 V5.06-0-64 V5.06-0-70 V5.07-0-08 or later GP5-145 None V5.07-0-08 or later GP5-146 None V5.07-0-08 or later Refer to the display which will appear when the server boot up. DACxxxxx Firmware Version x.xx-x-xx 2.2 BGI Start Condition BGI starts or resumes when any write commands are issued to the RAID Card shown as follow. Partitions were set by FDISK in MS-DOS or Disk Administrator in Windows NT. OS setup were started. OS setup were resumed after the system reboot. OS started after the OS setup completion. BGI is processed as background job. Pay attention to access LED of hard disk drives and do not cut the power supply of server when any access LED are lighting.

2.3 Procedure to Stop BGI If cutting the power supply off is needed when BGI is running, refer to following procedure. The case Windows NT installation is completed 1. Shut down the Windows NT. When shut down of OS completes, BGI stop automatically. 2. Confirm the access LED of hard disk drives turn off the light and switch off the power supply of the server. The case Windows NT installation is not completed 1. Set a MS-DOS bootable CD-ROM or floppy disk to the server. 2. Push the reset switch of server or [Ctrl]+[Alt]+[Delete] to reset the server. When system reset occurs, BGI stops. 3. Wait until the MS-DOS prompt appears. 4. Confirm the access LED of hard disk drives turn off the light and switch off the power supply of the server. BGI will resume from the stopped block when the first write received from the host system in the next time.

2.4 Confirmation of BGI Completion If the confirmation of BGI completion is needed, refer to following procedure. The case Windows NT installation is completed 1. Start the HDD Check Scheduler and check the consistency of all of the System Drive. 2. Start the Event Viewer and check the source CWNRAID1. 3. Confirm the message below, which shows the object System Drive was properly initialized. Consistency Check Completed Successfully. (2560/Information) Following message shows the object System Drive #x, #y, have not initialized completely yet. No Consistency Check started. System Drive #x, #y have not been optimized yet. (3105/Warning) The case Windows NT installation is not completed 1. Start DACCF and execute the Consistency Check 2. Confirm the message below, which shows the object System Drive was properly initialized. System drive found to be Consistent. Press any key to continue. Following message shows the object System Drive has not initialized completely yet. Cannot check consistency of a non-redundant or uninitialized System drive.

2.5 Approximate Execution Time of BGI The following table shows the time required to carry out BGI per 1 GB in the condition that system drives are entirely free from input/output operation. For example, the time required for BGI of the RAID 5 System Drive that is composed of three 9 GB hard disks is 108 minutes approximately (= 6 min/gb * 18 GB), for the total capacity of the System Drive is 18 GB (= 9GB * [3-1]). Use it as rule of thumb because the time depends on the RAID configurations and the type of hard disk drives. [Approximate execution time of DACCF initialization] Number of HDD RAID Level Execution time / GB 2 3 3 8 8 RAID1 RAID6 RAID6 8 min./gb 6 min./gb 10 min./gb 3 min./gb 10 min./gb Remark: Some contents are different from the User Guide but these contents are correct. 2.6 Other Notes The best performance may not be provided before BGI completion. Since DACCF initialization, which does not affect to the System Drive status, writes zero to all area of object System Drive, DACCF initialization erases all data in the object System Drive including the System Drive that BGI is not completed.