GMCT20 Cable Installation Instructions - National Instruments

Similar documents
TB-2606 Terminal Block Installation Guide (Multilingual)

NI SCXI-1335 Installation Instructions (Multilingual)

NI 651x 仕様 - National Instruments

NI TB-2630B 取り付け手順 - National Instruments

CAL-4353 キャリブレーション手順 - National Instruments

NI 6601/6602 キャリブレーション手順 - National Instruments

NI SCXI-1331 Installation Instructions (Multilingual)

Diskette Drive Installation

Diskette Drive Installation

Archived: LabVIEW Real-Timeモジュールリリースノートおよびアップグレードノート(日本語) - National Instruments

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

TB-2605 Isothermal Terminal Block Installation Guide (Multilingual)

fx-9860G Manager PLUS_J

NI PXI-2585 Specifications (Multilingual)

WIF6002-e



NSR-500 Installation Guide

Specification for Manual Pulse Generator, GFK-2262

AWS Client VPN - ユーザーガイド

TOOLS for UR44 Release Notes for Windows

NI 653X ケーブルアダプタユーザガイド - National Instruments

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part


How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

2

2

2

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

NI 1357/1358/1359 SCXI Controller/Adapter Kit Installation Guide (Multilingual)

2

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

Tab 5, 11 Tab 4, 10, Tab 3, 9, 15Tab 2, 8, 14 Tab 1, 7, 13 2


H8000操作編

SBAL FA-R5F10JBCANA-RX ユーザーズ マニュアル B5D 1

ドライバインストールガイド

0 C C C C C C C

V-SFTのインストール及び画面データの転送手順 V-SFT Installation and Screen Data Transfer Procedure

58 W type W タイプコネクタとは 58 コネクタ S タイプ (M ターミナルタブ幅 2.8mm) の防水コネクタです W TYPE CONNECTOR: THE BLADE WIDTH OF THE MALE TERMINAL FOR THIS CONNECTOR IS IN

MIDI_IO.book

19_22_26R9000操作編ブック.indb

BS・110度CSデジタルハイビジョンチューナー P-TU1000JS取扱説明書

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

FA-78F0138HDGK-8A8-RX ユーザーズ・マニュアル


Z7000操作編_本文.indb


Page 1 of 6 B (The World of Mathematics) November 20, 2006 Final Exam 2006 Division: ID#: Name: 1. p, q, r (Let p, q, r are propositions. ) (10pts) (a

SonicWALL SSL-VPN 4000 導入ガイド

NI PXI-2586 Specifications (Multilingual)


Microsoft Word - PrivateAccess_UM.docx

untitled

FA-78F0849GK-GAK-RX ユーザーズ・マニュアル

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool



0 C C C C C C

Connectors for Automobiles 62 SEALED SERIES Japanese English

PC_14ZY6_BFT150A_US_ indd

LC304_manual.ai


32C2100操作編ブック.indb

2 3


WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

インターネット接続ガイド v110

BNC-2110 取り付けガイド - National Instruments

ダウンロード方法 アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類が あります.tar フォーマットのソフトウェアとデバイス ファイルがバンドルされたセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストール

ダウンロード方法アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類があります.tar フォーマットのソフトウェアとデバイス ファイルの完全なセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストールするための

xEffect_SG_MV_Part2_E_xEffect_SG_MV_E

NI PXI-2503 Specifications (Multilingual)

ベース0516.indd

エレクトーンのお客様向けiPhone/iPad接続マニュアル


untitled

2

DDR3 SDRAMメモリ・インタフェースのレベリング手法の活用

Archived: Installation Guide, NI for Windows Driver Software Archive (English and Japanese) - National Instruments

Microsoft Word - FactoryActivationManagerQuickManualR00

スプリングプローブコネクタ、ライトアングルコネクタ

ダウンロード方法 アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類があります.tar フォーマットのソフトウェアとデバイス ファイルがバンドルされたセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストールす


MLA8取扱説明書

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STW Symbol Symbol otary switch) 05 otary switch Symbol angle of notch 181

Steinberg AXR4T Firmware Update Guide

Introduction Purpose This training course demonstrates the use of the High-performance Embedded Workshop (HEW), a key tool for developing software for

*Ł\”ƒ‚ä(DCH800)

Actual ESS Adapterの使用について

080906_…o…−…^…b…vVSCW

Microsoft Word - j201drills27.doc


MINAS取説アブソ警告クリア方法記載ミス_モータニュース…

FC741E2_091201


Huawei G6-L22 QSG-V100R001_02

iPhone/iPad接続マニュアル

Transcription:

INSTALLATION INSTRUCTIONS GMCT20 Cable Contents Conventions This guide describes how to connect and use the National Instruments GMCT20 cable, which has a maximum voltage rating of 300 V, CAT II. Use this cable to connect either the NI PXI-2585 or the NI PXI-2586 switch module to your application. Caution Only use this cable with the NI PXI-2585 or NI PXI-2586 module. The GMCT20 cable is available in two configurations: GMCT20-GMCT20 GMCT20-BARE WIRE Conventions... 1 What You Need to Get Started... 2 Getting Started with the GMCT20 Cable... 2 Connectors... 4 Cable Configurations... 4 GMCT20-GMCT20 Cable... 4 GMCT20-BARE WIRE Cable... 5 Specifications... 6 Environment... 6 The following conventions are used in this guide:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. italic monospace Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions.

What You Need to Get Started To use the cable, you need the following items: GMCT20 cable NI PXI-2585 or NI PXI-2586 switch module and documentation 1/4 in. (0.6 cm) flathead screwdriver Getting Started with the GMCT20 Cable Complete the following steps to connect the cable to the switch module and your application. Refer to Figures 1 through 3 for illustrations of the cable, and refer to Figure 4 for an illustration of the connector. Caution Always de-energize hazardous voltage sources before connecting or disconnecting this cable. 1. Connect the GMCT20 connector to the front connector on the switch module as shown in Figure 1. 3 2 NI PXI-2585 10x1 Power Multiplexer 1 1 Screws 2 GMCT20 Connector 3 NI PXI-2585 Connector Figure 1. Connecting the Cable to the NI PXI-2585 2. Tighten the screws on the cable with a 1/4 in. (0.6 cm) flathead screwdriver. GMCT20 Cable Installation Instructions 2 ni.com

3. Complete one of the following steps and refer to Tables 1 and 2 in the Cable Configurations section to determine how to connect signals to your application. Connect the second GMCT20 connector on the cable to your application. Connect the unterminated wires to your application. 1 2 2 1 1 GMCT20 Connectors 2 Screws Figure 2. GMCT20-GMCT20 Cable 1 2 3 1 GMCT20 Connector 2 Screws 3 20 Unterminated, Tinned, and Stripped Wires Figure 3. GMCT20-BARE WIRE Cable National Instruments Corporation 3 GMCT20 Cable Installation Instructions

Connectors The cable connects a 20-pin female Positronic GMCT connector (GMCT20 connector) to a second GMCT20 connector or twenty unterminated, tinned, and stripped wires. The GMCT20 connector provides connection to the switch module. The second GMCT20 connector and unterminated cables provide connection to your application. Figure 4 shows the pinout for the GMCT20 connector. PIN B PIN A PIN C PIN W PIN X PIN U Figure 4. GMCT20 Mating Connector Cable Configurations The GMCT20 cable is available in two configurations: GMCT20-GMCT20 GMCT20-BARE WIRE The following sections describe each of the configurations. GMCT20-GMCT20 Cable The GMCT20-GMCT20 cable is recommended for connecting the switch module to your system. Use the pinouts and the pin assignments listed in Table 1 to determine how to connect signals to your application using the GMCT20-GMCT20 cable. Refer to the NI Switches Help for a complete listing of channel names and pinouts. In the following table, letters in parentheses reference the pin designators of the connector. Table 1. Pin Assignment for GMCT20-GMCT20 Cable GMCT20 P1/P2 Pin NI PXI-2585 Channel NI PXI-2586 Channel A CH6 (A) CH6 (A) B COM6 (B) C CH0 (C) COM0 (C) D COM7 (D) E CH5 (E) CH5 (E) F CH0 (F) H CH7 (H) CH7 (H) GMCT20 Cable Installation Instructions 4 ni.com

Table 1. Pin Assignment for GMCT20-GMCT20 Cable (Continued) GMCT20 P1/P2 Pin NI PXI-2585 Channel NI PXI-2586 Channel J COM5 (J) K CH1 (K) COM1 (K) L COM8 (L) M CH4 (M) CH4 (M) N CH1 (N) P CH8 (P) CH8 (P) R COM4 (R) S CH2 (S) COM2 (S) T COM9 (T) U COM0 (U) CH3 (U) V CH2 (V) W CH9 (W) CH9 (W) X CH3 (X) COM3 (X) GMCT20-BARE WIRE Cable The GMCT20-BARE WIRE cable is recommended for connecting the switch module to your system if termination other than a GMCT20 connector is required. One end of the cable terminates with a GMCT20 connector. The other end of the cable has twenty unterminated, tinned, and stripped wires. Use the pinouts and the pin assignments listed in Table 2 to determine how to connect signals to your application. In the following table, letters in parentheses reference the pin designators of the connector. Table 2. Pin Assignment for GMCT20-BARE WIRE Cable GMCT20 Pin Wire Label NI PXI-2585 Channel NI PXI-2586 Channel A BLACK CH6 (A) CH6 (A) B RED COM6 (B) C WHITE CH0 (C) COM0 (C) D GREEN COM7 (D) E ORANGE CH5 (E) CH5 (E) F BLUE CH0 (F) H BROWN CH7 (H) CH7 (H) J YELLOW COM5 (J) K VIOLET CH1 (K) COM1 (K) L GRAY COM8 (L) National Instruments Corporation 5 GMCT20 Cable Installation Instructions

Specifications Maximum voltage...300 V, CAT II Caution A total power load greater than 400 A 2 channels will damage the GMCT20 cable under certain conditions. Refer to the NI PXI-2586 Specifications for example calculations and additional information about load derating. Maximum current Per channel...12 A Simultaneous channelsat maximum current...2 Weight GMCT20-GMCT20...499 g (17.6 oz) GMCT20-BARE WIRE...748 g (26.4 oz) Environment Operating temperature...0 C to 55 C Storage temperature... 20 C to 70 C Relative humidity...5% to 85%, noncondensing Pollution Degree...2 Maximum altitude...2,000 m Indoor use only. Table 2. Pin Assignment for GMCT20-BARE WIRE Cable (Continued) GMCT20 Pin Wire Label NI PXI-2585 Channel NI PXI-2586 Channel M PINK CH4 (M) CH4 (M) N TAN CH1 (N) P RED/GREEN CH8 (P) CH8 (P) R RED/YELLOW COM4 (R) S RED/BLACK CH2 (S) COM2 (S) T WHITE/BLACK COM9 (T) U WHITE/RED COM0 (U) CH3 (U) V WHITE/GREEN CH2 (V) W WHITE/YELLOW CH9 (W) CH9 (W) X WHITE/BLUE CH3 (X) COM3 (X) National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 2009 National Instruments Corporation. All rights reserved. 375861A Aug09

取り付け手順 GMCT20 ケーブル 目次 表記規則 このガイドでは 最大電圧定格が 300 V CAT II の NI GMCT20 ケーブルの接続方法および使用方法について説明します このケーブルを使用して NI PXI-2585 または NI PXI-2586 スイッチモジュールをアプリケーションに接続します 注意このケーブルは NI PXI-2585 または NI PXI-2586 モジュールとのみ使用してください GMCT20 ケーブルには次の 2 つの構成があります GMCT20-GMCT20 GMCT20-BARE WIRE 表記規則...1 使用を開始する前に...2 GMCT20 ケーブルを使用する...2 コネクタ...4 ケーブル構成...4 GMCT20-GMCT20 ケーブル...4 GMCT20-BARE WIRE ケーブル...5 仕様...6 動作環境...6 このドキュメントでは 以下の表記規則を使用します 矢印 ( ) は ネスト化されたメニュー項目やダイアログボックスのオプションをたどっていくと目的の操作項目を選択できることを示します ファイル ページ設定 オプションと表記されている場合は まずファイルメニューをプルダウンし 次にページ設定項目を選択し 最後にダイアログボックスでオプションを選択します このアイコンは 人体への損傷やデータ損失 システムクラッシュなどを回避するために必要な注意事項を示します 斜体 monospace 斜体のテキストは 変数 強調 相互参照 または重要な概念の説明を示します また 斜体のテキストは ユーザが入力する必要がある語句または値のプレースホルダも示します このフォントのテキストは キーボードから入力する必要があるテキストや文字 コードの一部 プログラムサンプル 構文例を表します また ディスクドライブ パス ディレクトリ プログラム サブプログラム サブルーチンなどの名称 デバイス名 関数 演算 変数 ファイル名および拡張子の引用にも使用されます

使用を開始する前に ケーブルを使用するには 以下が必要となります GMCT20 ケーブル NI PXI-2585 または NI PXI-2586 スイッチモジュールおよびドキュメント 1/4 インチ (0.6 cm) マイナスドライバー GMCT20 ケーブルを使用する ケーブルをスイッチモジュールおよびアプリケーションに接続するには次の手順に従います ケーブルの取り付けについては図 1 ~ 3 を参照し コネクタの図解は図 4 を参照してください 注意このケーブルの接続または接続解除を行う前に 必ず危険電圧のソースを切断してください 1. 図 1 に示すように GMCT20 コネクタをスイッチモジュールのフロントコネクタに接続します 3 2 NI PXI-2585 10x1 Power Multiplexer 1 1 ネジ 2 GMCT20 コネクタ 3 NI PXI-2585 コネクタ 図 1 ケーブルを NI PXI-2585 に接続する 2. 1/4 インチ (0.6 cm) マイナスドライバーを使用してネジを締めます GMCT20 ケーブル取り付け手順 2 ni.com/jp

3. 次のいずれかの手順を実行し ケーブル構成 セクションの表 1 および 2 を参照して信号をアプリケーションに接続する方法を確認します ケーブルの 2 つめの GMCT20 コネクタをアプリケーションに接続します 非終端ワイヤをアプリケーションに接続します 1 2 2 1 1 GMCT20 コネクタ 2 ネジ 図 2 GMCT20-GMCT20 ケーブル 1 2 3 1 GMCT20 コネクタ 2 ネジ 3 20 非終端 すずめっき 裸線 図 3 GMCT20-BARE WIRE ケーブル National Instruments Corporation 3 GMCT20 ケーブル取り付け手順

コネクタケーブルを使用して 20 ピンメス Positronic GMCT コネクタ (GMCT20 コネクタ ) を 2 つめの GMCT20 コネクタまたは 20 本の非終端のすずめっき裸線に接続します GMCT20 コネクタは スイッチモジュールへの接続に使用します 2 つめの GMCT20 コネクタおよび非終端ケーブルはアプリケーションへの接続に使用します 図 4 は GMCT20 コネクタのピン配列を示します B A C W X U 図 4 GMCT20 メイトコネクタ ケーブル構成 GMCT20 ケーブルには次の 2 つの構成があります GMCT20-GMCT20 GMCT20-BARE WIRE 次のセクションでは 各構成について説明します GMCT20-GMCT20 ケーブルスイッチモジュールとシステムの接続には GMCT20-GMCT20 ケーブルの使用が推奨されています ピン配列および表 1 のピン割り当て一覧を使用して GMCT20-GMCT20 を使用したアプリケーションへの信号接続方法を確認します チャンネル名およびピン配列の一覧については NI スイッチヘルプ を参照してください 次の表の括弧内の文字はコネクタのピン識別子を示しています 表 1 GMCT20-GMCT20 ケーブルのピン割り当て GMCT20 P1/P2 ピン NI PXI-2585 チャンネル NI PXI-2586 チャンネル A CH6 (A) CH6 (A) B COM6 (B) C CH0 (C) COM0 (C) D COM7 (D) E CH5 (E) CH5 (E) F CH0 (F) GMCT20 ケーブル取り付け手順 4 ni.com/jp

表 1 GMCT20-GMCT20 ケーブルのピン割り当て ( 続き ) GMCT20 P1/P2 ピン NI PXI-2585 チャンネル NI PXI-2586 チャンネル H CH7 (H) CH7 (H) J COM5 (J) K CH1 (K) COM1 (K) L COM8 (L) M CH4 (M) CH4 (M) N CH1 (N) P CH8 (P) CH8 (P) R COM4 (R) S CH2 (S) COM2 (S) T COM9 (T) U COM0 (U) CH3 (U) V CH2 (V) W CH9 (W) CH9 (W) X CH3 (X) COM3 (X) GMCT20-BARE WIRE ケーブル GMCT20-BARE WIRE ケーブルは GMCT20 コネクタ以外の終端が必要な場合のスイッチモジュールとシステム間の接続に推奨されています ケーブルの一端は GMCT20 コネクタで終端されます ケーブルのもう一端は 20 本の非終端のすずめっき裸線です ピン配列および表 2 のピン割り当て一覧を使用して アプリケーションへの信号接続方法を確認します 次の表の括弧内の文字はコネクタのピン識別子を示しています 表 2 GMCT20-BARE WIRE ケーブルのピン割り当て GMCT20 ピンワイヤのラベル NI PXI-2585 チャンネル NI PXI-2586 チャンネル A 黒 CH6 (A) CH6 (A) B 赤 COM6 (B) C 白 CH0 (C) COM0 (C) D 緑 COM7 (D) E オレンジ CH5 (E) CH5 (E) F 青 CH0 (F) H 茶 CH7 (H) CH7 (H) J 黄色 COM5 (J) National Instruments Corporation 5 GMCT20 ケーブル取り付け手順

仕様 表 2 GMCT20-BARE WIRE ケーブルのピン割り当て ( 続き ) GMCT20 ピン ワイヤのラベル NI PXI-2585 チャンネル NI PXI-2586 チャンネル K 紫 CH1 (K) COM1 (K) L 灰色 COM8 (L) M ピンク CH4 (M) CH4 (M) N 黄褐色 CH1 (N) P 赤 / 緑 CH8 (P) CH8 (P) R 赤 / 黄色 COM4 (R) S 赤 / 黒 CH2 (S) COM2 (S) T 白 / 黒 COM9 (T) U 白 / 赤 COM0 (U) CH3 (U) V 白 / 緑 CH2 (V) W 白 / 黄色 CH9 (W) CH9 (W) X 白 / 青 CH3 (X) COM3 (X) 最大電圧...300 V CAT II 注意 400 A 2 をチャンネル数で乗算した値が合計電力負荷を上回ると 特定の条件下では GMCT20 ケーブルが破損します 計算例および負荷の低下については NI PXI-2586 仕様 を参照してください 最大電流チャンネルあたり...12 A 最大電流で同時に使用可能なチャンネル数...2 重量 GMCT20-GMCT20...499 g(17.6 oz) GMCT20-BARE WIRE...748 g(26.4 oz) 動作環境動作温度...0 ~ 55 保管温度... 20 ~ 70 相対湿度...5 ~ 85%( 結露なきこと ) 汚染度...2 最大使用高度...2,000 m 室内使用のみ National Instruments NI ni.com および LabVIEW は National Instruments Corporation ( 米国ナショナルインスツルメンツ社 ) の商標です National Instruments の商標の詳細については ni.com/legal の Terms of Use セクションを参照してください 本文書中に記載されたその他の製品名および企業名は それぞれの企業の商標または商号です National Instruments の製品 / 技術を保護する特許については ソフトウェアで参照できる特許情報 ( ヘルプ 特許情報 ) メディアに含まれている patents.txt ファイル または National Instruments Patent Notice (ni.com/patents) のうち 該当するリソースから参照してください 2009 National Instruments Corporation. All rights reserved. 375861A-01 2009 年 8 月