OVERVIEW ProLiant ML570 Generation 3 ProLiant ML570 (SCSI ) SCSI ID SCSI LED IDE DVD-ROM ( ) Ultra320 SCSI A B C 3.5 ( ) ( ) ProL

Similar documents
OVERVIEW ProLiant ML350 ProLiant ML350 Generation 4p A B 2 A B C D IDE CD-ROM 3.5 USB 6 PCI (PCI-X 4 PCI Express 2) Smart ProLiant M

HP ProLiant ML370 Generation

OVERVIEW ProLiant ML350 Generation 4 ProLiant ML IDE CD-ROM USB 6 4 () PCI (PCI-X 4 PCI-Express 2) ( ) A B C D C D 0 5 () N0 N3 () C D 2 (

ProLiant DL380 Generation 4 システム構成図

システムユニット構成ツリーの見方

OVERVIEW ProLiant DL380 ProLiant DL380(X3060) IDs 2-5 IDs 0-5 IDs 0 1 A 3.5 IDE CD-ROM B LED LED Wide Ultra3/Ultra320 C U 0

OVERVIEW ProLiant ML370(X2800, X3060, X3200) ProLiant ML370 A B D B C D B C 2 () (2 ) (1.6 ) 3.5 LED 48 IDE CD-ROM 5.25 Wide Ultra3/

OVERVIEW ProLiant DL365 ProLiant DL365 A 1 4 SATA 5 6 * 2 Systems Insight Display /SATA 6* 2 Smart P400i Smart E200i ( ) / PCI Express x8(x8 ) PCI Exp

システムユニット構成ツリーの見方

OVERVIEW ProLiant ML350(X2800, X3060) ProLiant ML350 A B C D IDE CD-ROM Wide Ultra3/Ultra320 PCI (64 /100Mz PCI-X 4 32 /33Mz PCI 1) ( ) (CP) P

システムユニット構成ツリーの見方

OVERVIEW ProLiant ML370(X2400, X2800, X3060, X3200) ProLiant ML370 A B D B C D B C 2 () (2 ) (1.6 ) 3.5 LED 48 IDE CD-ROM 5.25 Wide Ultra3/U

システムユニット構成ツリーの見方

HP ProLiant ML310 Generation 5 システム構成図

ProLiant DL385 Generation 2 システム構成図

OVERVIEW ProLiant ML350 G5 Storage Server ProLiant ML350 G5 Storage Server LFF(3.5") A B C D SFF(2.5") 4 16 DVD 2 6 LFF(3.5") /SATA A B C D E 6(PCI Ex

OVERVIEW ProLiant ML350 G4p Storage Server SATA ProLiant ML350 G4p Storage Server A B 2 A B C D 3.5 S1 S6 3.5 SATA IDE CD-ROM 3.5 USB 6 PCI (P

ProLiant DL380 Generation 4 システム構成図

ProLiant ML150 Generation 3 システム構成図

ProLiant ML110 システム構成図

ProLiant DL180 システム構成図

HP ProLiant ML310 Generation 3 システム構成図

ProLiant ML110 Generation 4 システム構成図

ProLiant DL380 SAN Storageモデル システム構成図

ProLiant DL165 G6 システム構成図

OVERVIEW hp StorageWorks NAS 2000s hp StorageWorks NAS 2000s A 3.5 B 3.5 IDE DVD-ROM C LED LED Ultra320 SCSI ( ) NAS 2000s NAS 2000s NAS

ProLiant ML115 Generation 1 システム構成図

OVERVIEW ProLiant ML370 Generation 5 ProLiant ML370 G5 A B B C USB SATA RAID 3 PCI-X 64 /133Mz 2 Systems Insight Display(SID) PCI E

ProLiant DL380 Generation 4 システム構成図

ProLiant DL385 Generation5 システム構成図

ProLiant ML110 Generation 4 システム構成図

OVERVIEW ProLiant ML330 ProLiantML330(P1266)ATA PAQ V 0 A IDE CD-ROM PCI 64 PCI ( ) A B B B C D E 0 1 (1 ) (IDE ) 3.5 (1 ) (SCSI ) ProLi

ProLiant BL20p Generation 4 システム構成図

ProLiant ML115 Generation 1 システム構成図

ProLiant BL35p システム構成図

ProLiant DL140 システム構成図

ProLiant BL460c システム構成図

ProLiant BL25p Generation 2システム構成図

OVERVIEW ProLiant ML110 G2 Storage Server ProLiant ML110 G2 Storage Server A C D SATA NH 320GB 01 (1TB) (1TB) Ultra320 SCSI 6 SATA RAID Serial

HP ProLiant ML110 Generation 5 システム構成図

ProLiant DL580 G5 システム構成図

ProLiant SL6000 Sclable System システム構成図

システムユニット構成ツリーの見方

ProLiant DL380 G6 システム構成図

ProLiant DL1000 マルチノード サーバー システム構成図

PROLIANT ML

PROLIANT ML

OVERVIEW ProLiant ML350 Generation 5 ProLiant ML350 G5 (2.5 ) A B C D USB A B C D E Xeon E Gz (2.5" ) 1 8 (2.5" ) 4 6(PCI Express 3 PCI-

ProLiant BL460c システム構成図

(MSA )

( ) LinuxLinux HP Linux( Linux DAT USB DAT SAS DAT LTO SAS LTO DAT (/USB ) / (2.5m) DAT / (6 ) B21 7,700 ( 8,085 )

OVERVIEW * SATA MSA SAS(Serial Attached ) FC ( ) FC SATA(Serial ATA) PC SMB SATA 1GB SATA TCO I/O SAS FC(FC-AL) 8 /1 24 /1 5400rpm 7200rpm 1000


OVERVIEW hp StorageWorks NAS 500s hp StorageWorks NAS 500s A C D () 4 SATA RAID Ultra320 SCSI Serial ATA 3.5 DVD-ROM hp StorageWorks NAS 500s


OVERVIEW ProLiant ML110 Storage Server ProLiant ML110 Storage Server A C D () 4 SATA RAID Ultra320 SCSI Serial ATA 3.5 DVD-ROM DVD-ROM ProLia

OVERVIEW MSA [SCSI ] HP StorageWorks MSA 20 (P.3) HP StorageWorks MSA 30 (P.4) HP StorageWorks MSA 500 (P.7) HP StorageWorks MSA 500 G2 (P.11) [ ] HP

OVERVIEW ProLiant DL100 Storage Server ProLiant DL100 Storage Server LED USB (PS/2) (PS/2) USB UID RJ-45 4 SATA RAID SCSI ( ) ProLiant DL100 Storage S

OVERVIEW MSA [SCSI ] HP StorageWorks MSA 20(P.3) HP StorageWorks MSA 30(P.4) HP StorageWorks MSA 500(P.7) HP StorageWorks MSA 500 G2(P.11) [ ] HP Stor

ProLiant BL480c システム構成図

OVERVIEW MSA [SCSI ] hp StorageWorks MSA 20(P.3) hp StorageWorks MSA 30 StorageWorks 4300(P.4) hp StorageWorks MSA 500 (P.8) hp StorageWorks MSA 500 (

BL tc2120ml110dl140dl145 ProLiant Essentials Foundation ProLiant Essentials Foundation OS DOS Insight ProLiant Essentials Foundation ( MS-DOS ) ProLia

BL tc2120ml110dl140dl145 ProLiant Essentials Foundation ProLiant Essentials Foundation OS DOS Insight ProLiant Essentials Foundation ( MS-DOS ) ProLia

サーバ製品 システム構成図 ( オプションリスト ) 2004 年 4 月 15 日 1

ProLiant BL260c G5 システム構成図

OVERVIEW hp StorageWorks NAS 1500s hp StorageWorks NAS 1500s LED USB (PS/2) (PS/2) USB UID RJ-45 4 SATA RAID hp StorageWorks NAS 1500s 320GB 1TB 36798

ProLiant BL460c G6 システム構成図

HP StorageWorks P4000 G2 SAN Solutions (LeftHand ) システム構成図

BL tc2120 ProLiant Essentials Foundation ProLiant Essentials Foundation OS DOS Insight ProLiant Essentials Foundation ( MS-DOS ) ProLiant Essentials F

Standard Features 550MHz ProLiant 6400R 6/550-2M /550-1M / MHz ProLiant 6400R 6/500-

StorageWorks MSA2000 シリーズ システム構成図

Pentium III Standard Features 600MHz ProLiant 3000R 6/ Smart3200 Wide Ultra2 550MHz ProLiant 3000R 6/

OVERVIEW MSL2024 Ultrium448,Ultrium920,Ultrium960,Ultrium1840 MSL2024 2U (1 ) Ultrium448 Ultrium920 Ultrium960 Ultrium1840 SCSI SAS FC 1 Ultriu

MSA2300ファミリ システム構成図

HP StorageWorks テープバックアップ・シリーズ

MSA2000ファミリ システム構成図

1

15†FHPPS02 P111†`125

HP StorageWorks ストレージ総合カタログ

rx600_s3_sas.pdf


HP ProLiant 500シリーズ

Express5800/140Hb (2002/01/22)

2000 9

2011年2月 Express5800シリーズ Gモデル

rx600_s2.pdf

テープバックアップ・シリーズ

SharePoint 2003 Performance White Paper

Express5800/120Ra-1

rx600_s3.pdf

HP ProLiantサーバ 価格改定製品一覧

BL tc2120ml110dl140dl145 ProLiant Essentials Foundation ProLiant Essentials Foundation OS DOS Insight ProLiant Essentials Foundation ( MS-DOS ) ProLia

HP BLADE WORKSTATION ソリューション

Express5800/120Le


rx600_s2.pdf

HP Compaq Business Desktop dx7300シリーズ

HP xw9400 Workstation

blade.pdf

HP BladeSystem c-Class Infrastructure Component システム構成図

Transcription:

P ProLiant ML570 Generation 3 2007 3 8 1

OVERVIEW ProLiant ML570 Generation 3 ProLiant ML570 (SCSI ) SCSI ID 0 7 8 9 3.5 SCSI LED IDE DVD-ROM 5.25 3.5 ( ) Ultra320 SCSI A B C 3.5 ( ) ( ) ProLiant ML570 G3 ( ) R03 X3660-1M 1P 1GB 385943-291( ) 64 Xeon MP 3.66Gz 1P/1C 4P/4C /CPU 1MB L2 / Intel E8500 (667Mz FSB) 1GB (PC2-3200 ECC DDR2 SDRAM) 64GB ( ) DVD-ROM IDE DVD-ROM ( 8 /DVD-ROM 24 /CD-ROM) 1 ( 1) 10 (1 Ultra320 SCSI 2 (8+2)) Ultra320 SCSI ( ) ( ) 3TB ( ) 105TB (Modular Smart Array 30 SB 25 ) 10 (PCI Express x4 4 64 /133Mz PCI-X 2 (3.3V) 64 /100Mz PCI-X 4 (3.3V)* 2 ) NC7782 PCI-X Gigabit NIC 10/100/1000 (WOL PXE ) RJ-45 2 USB2.0 4 ( 1/ 2/ 1) ilo RJ-45 Ultra320 SCSI 1280 1024 1677 (100V ) 1122W* 3 12A (100V) / 8A (200V)* 4 100-120V (50z-60z) / 200-240V (50z-60z)* 4 * 1 C 0.027 (W D ) 483 711 282mm ( ) 6U () 62.1kg ProLiant Essentials Foundation Pack (SmartStart CD Management CD) OS Windows 2000 Server/Advanced Server Windows Server 2003 Standard/Enterprise Edition Linux* 5 1 2 4 64 /100Mz PCI-X 2 2 3 1P/1C 1 ( 2 ) 4 100V NEMA5-15P 200V C14-19 (200V PDU UPS ) 1P/1C 1 5Linux URL http://www.hp.com/jp/linux URL http://h50146.www5.hp.com/products/servers/proliant/ml570g3_sh.html 2

OVERVIEW ProLiant ML570 Generation 3 ProLiant ML570 (SCSI ) SCSI ID 0 7 8 9 3.5 SCSI LED IDE DVD-ROM 5.25 3.5 ( ) Ultra320 SCSI A B C 3.5 ( ) ( ) ProLiant ML570 G3 ( ) DC X3/2x2M 2P 2GB SCSI R 399364-291( ) Xeon 7040 3Gz 2P/4C 4P/8C /CPU 2 2MB L2 / Intel E8500 (667Mz FSB) 2GB (PC2-3200 ECC DDR2 SDRAM) 64GB ( ) DVD-ROM IDE DVD-ROM ( 8 /DVD-ROM 24 /CD-ROM) 1 ( 1) 10 (1 Ultra320 SCSI 2 (8+2)) Ultra320 SCSI ( ) ( ) 3TB ( ) 105TB (Modular Smart Array 30 SB 25 ) 10 (PCI Express x4 4 64 /133Mz PCI-X 2 (3.3V) 64 /100Mz PCI-X 4 (3.3V)* 2 ) NC7782 PCI-X Gigabit NIC 10/100/1000 (WOL PXE ) RJ-45 2 USB2.0 4 ( 1/ 2/ 1) ilo RJ-45 Ultra320 SCSI 1280 1024 1677 (100V ) 1345W* 3 12A (100V) / 8A (200V)* 4 100-120V (50z-60z) / 200-240V (50z-60z)* 4 * 1 C 0.012 (W D ) 483 711 282mm ( ) 6U () 62.1kg ProLiant Essentials Foundation Pack (SmartStart CD Management CD) OS Windows 2000 Server/Advanced Server Windows Server 2003 Standard/Enterprise Edition Linux* 5 1 2 4 64 /100Mz PCI-X 2 2 3 2P/2C 2P/4C 2 ( ) 4 100V NEMA5-15P 200V C14-19 (200V PDU UPS ) 2P/2C 2P/4C 2 5Linux URL http://www.hp.com/jp/linux URL http://h50146.www5.hp.com/products/servers/proliant/ml570g3_sh.html 3

OVERVIEW ProLiant ML570 Generation 3 ProLiant ML570 Generation 3 2007 3 LinuxLinux P Linux(http://www.hp.com/jp/linux/) Linux ProLiant ML570 G3 (6U) R03 X3660-1M 1P 1GB 385943-291 870,000 ( 913,500 ) ProLiant ML570 G3 (6U) Dual Core X7040 3Gz x2 2x2MB L2 2GB SCSI 399364-291 2,160,000 ( 2,268,000 ) (61-91cm) ProLiant Essentials Foundation Pack SmartStart CD( ) Management CD(Insight ) OS DOS ProLiant Insight SmartStart ( MS-DOS ) Xeon MP 3.66Gz 1MB 385903-B21 220,000 ( 231,000 ) 4 () Xeon 7040 3Gz 2x2MB L2 Dual Core 399889-B21 660,000 ( 693,000 ) 4

1GB (2 512MB PC2-3200) 343055-B21 30,000 ( 31,500 ) 1GB 1 2GB 2 2GB (2 1GB PC2-3200) 343056-B21 54,000 ( 56,700 ) 4GB (2 2GB PC2-3200) 375004-B21 140,000 ( 147,000 ) 4GB (2 2GB PC2-3200) 343057-B21 240,000 ( 252,000 ) 8GB (2 4GB PC2-3200) 348106-B21 900,000 ( 945,000 ) 348107-B21 36,000 ( 37,800 ) 1 4 1 3 (6 ) DIMM 2 1 ( ) ( 12 ) 4 7 8GB 2 64GB 1 ML570 G3 (2 4 ) RAID (4 ) URL http://h50146.www5.hp.com/products/servers/proliant/technology/ adv_mem/index.html ( ECC ) 64GB 1 / ( ) 1 2 48GB ( 64GB) 2 1 2 16GB ( 16GB) 4 1 2( 1) 3 4( 2) 32GB ( 64GB) 1 2 RAID 4 4 48GB ( 64GB) 1 DIMM 2 DIMM 4 (P.3) http://www.compaq.co.jp/products/servers/proliant/whitepaper/wp034_050501/ index.html OS / A B C 1 2 3 4 5 6 7 5

SCSI Ultra320 SCSI ( 2 2 ) VDCI 1 SCSI - SCSI SCSI SCSI Ultrium960 SCSI VDCI 3.5 SCSI PCI-X SCSI 64bit/133Mz Ultra320 SCSI G2 374654-B21 16,000 ( 16,800 ) 68 1 VDCI 1 1 (Ultium 960 ) 3.5 SCSI VDCI PCI-X 133Mz ML570 G3 100Mz PCI-X 100Mz 1 SCSI ( ) Wide Ultra2/Ultra3/Ultra320 SCSI SCSI SCSI SCSI SCSI Ultra320 SCSI 64bit/133Mz Ultra320 SCSI G2 ProLiant Windows Server 2003 Windows Server 2003 SP1 CD-ROM 6

PCI-X Smart P600 337972-B21 92,000 ( 96,600 ) SAS/SATA x4 SAS 2 ( 1 / 1 x4 SAS ) 64 /133Mz PCI-X 256MB / RAID 6(ADG) SAS x4 MSA SAS (MSA50) 512MB 372538-B21 80,000 ( 84,000 ) 256MB 512MB ( ) PCI-X 133Mz ML570 G3 100Mz PCI-X 100Mz Smart ACU(Array Configuration Utility) Windows 2000 SP3 URL http://h50146.www5.hp.com/support/customer_advisories/cats030329_01.html RAID 6(ADG)(Advanced Data Guarding) 2 2 ( 4 ) Smart P600 ProLiant Windows Server 2003 Windows Server 2003 SP1 CD-ROM 7

PCI-X Smart 641 291966-B21 50,000 ( 52,500 ) SCSI Ultra320 SCSI (1) 64 /133Mz PCI-X 64MB 3.5 SCSI 128MB 351580-B21 30,000 ( 31,500 ) 192MB Smart 642 291967-B21 70,000 ( 73,500 ) Ultra320 SCSI (1 VDCI 1) 64 /133Mz PCI-X 64MB 2 1 1 Smart 6404/256 273914-B21 160,000 ( 168,000 ) Ultra320 SCSI 4 (2 VDCI 4) 64 /133Mz PCI-X 256MB / RAID 6(ADG) Smart 6404 2 ( / ) 3 RAID VDCI MSA SATA SCSI 512MB 372538-B21 80,000 ( 84,000 ) 128MB 256MB 512MB ( ) Smart 6402/128 273915-B21 98,000 ( 102,900 ) Ultra320 SCSI (2 VDCI 2) 64 /133Mz PCI-X 128MB / RAID 6(ADG) 2 273911-B21 70,000 ( 73,500 ) 2 ( VDCI 2) 2 3 RAID 512MB PCI-X 133Mz ML570 G3 100Mz PCI-X 100Mz 1 ( ) Smart SCSI SCSI ACU(Array Configuration Utility) Windows 2000 SP3 URL http://h50221.www5.hp.com/cpo_tc/customer_advisories/ca_servers/cats030329_01.html RAID 6(ADG)(Advanced Data Guarding) 2 2 ( 4 ) 8

PCI Express MSA1000 MSA1500 EVA4000/6000/8000 (EBS) FC1142SR 4Gb PCI-e BA AE311A 151,000 ( 158,550 ) PCI Express x4 OS Windows 2000 Windows Server 2003 Linux LC MSA1000 MSA1500 EVA4000/6000 EVA8000 FC FC1242SR 4Gb PCI-e BA AE312A 233,000 ( 244,650 ) LC PCI Express x4 800MB/s 2 2 OS Windows 2000 Windows Server 2003 Linux 4Gb PCI-e FC BA (FC2142SR) LC A8002A 151,000 ( 158,550 ) PCI Express x4 OS Windows 2000 Windows Server 2003 Linux Linux2.4 4Gb PCI-e FC BA (FC2242SR) LC A8003A 233,000 ( 244,650 ) PCI Express x4 800MB/s 2 2 OS Windows 2000 Windows Server 2003 Linux Linux2.4 ML570G3 4 PCI Express EVA4000/6000/8000 2 ( ) LinuxLinux(http://www.hp.com/jp/linux) MSA SAN (EBS) URL EBS Compatibility Matrix http://h18006.www1.hp.com/products/storageworks/tapecompatibility.html 9

PCI-X MSA1000 MSA1500 EVA4000/6000/8000 (EBS) FCA2214 281541-B21 178,000 ( 186,900 ) 64 /133Mz PCI-X OS Windows 2000 Windows Server 2003 Linux MSA1000 V2 Windows Windows 2000(SP3 ) Windows Server 2003 FCA2214DC 321835-B21 288,000 ( 302,400 ) LC LC 64 /133Mz PCI-X 400MB/s 2 2 OS Windows 2000 Windows Server 2003 Linux MSA1000 V2 Windows Windows 2000(SP3 ) Windows Server 2003 MSA MSA1000 MSA1000 MSA1500 EVA4000/6000 EVA8000 FC FC1143 4Gb PCI-X 2.0 266Mz BA LC AB429A 152,000 ( 159,600 ) 64 /266Mz PCI-X OS Windows 2000 Windows Server 2003 Linux FC1243 4Gb PCI-X 2.0 266Mz BA LC AE369A 234,000 ( 245,700 ) 64 /266Mz PCI-X 800MB/s 2 2 OS Windows 2000 Windows Server 2003 Linux FC2143 4Gb PCI-X 2.0 266Mz BA LC AD167A 152,000 ( 159,600 ) 64 /266Mz PCI-X OS Windows 2000 Windows Server 2003 Linux Linux2.4 FC2243 4Gb PCI-X 2.0 266Mz BA LC AD168A 234,000 ( 245,700 ) 64 /266Mz PCI-X 800MB/s 2 2 OS Windows 2000 Windows Server 2003 Linux Linux2.4 PCI-X 133Mz 266Mz ML570 G3 100Mz PCI-X 100Mz EVA4000/6000/8000 2 ( ) LinuxLinux(http://www.hp.com/jp/linux) MSA SAN (EBS) URL EBS Compatibility Matrix http://h18006.www1.hp.com/products/storageworks/tapecompatibility.html 10

3.5 SCSI SCSI Ultra320 SCSI Ultra320 SCSI SCSI Ultra320 SCSI 8 2 2 10 1 SCSI ( ) 0+1 4+5 SCSI 2 36.4GB 15krpm (Ultra320 SCSI 1 ) 286776-B22 34,000 ( 35,700 ) 72.8GB 10krpm (Ultra320 SCSI 1 ) 286714-B22 38,000 ( 39,900 ) 72.8GB 15krpm (Ultra320 SCSI 1 ) 286778-B22 50,000 ( 52,500 ) 146.8GB 10krpm (Ultra320 SCSI 1 ) 286716-B22 50,000 ( 52,500 ) 146.8GB 15krpm (Ultra320 SCSI 1 ) 347708-B22 86,000 ( 90,300 ) 300GB 10krpm (Ultra320 SCSI 1 ) 350964-B22 100,000 ( 105,000 ) 300GB 15krpm (Ultra320 SCSI 1 ) 411089-B22 150,000 ( 157,500 ) Ultra320 SCSI Ultra320 SCSI SCSI SCSI 11

DAT ( ) 68 SCSI 2 (Ultra320 SCSI) 68 DAT 72i/40i 1 SCSI 4 68 StorageWorks DAT 72( ) Q1522B 98,000 ( 102,900 ) Wide Ultra3 SCSI 36/72GB ( ) (1 ) 1 P DAT 72 C8010A 3,600 ( 3,780 ) 1 36/72GB DDS 1 C5709A 880 ( 924 ) Ultra320 SCSI 2 SCSI DAT (USB ) USB StorageWorks DAT72-USB( ) DW026A 88,000 ( 92,400 ) USB 2.0 36/72GB DAT Insight Agent ( ) (1 ) 1 P DAT 72 C8010A 3,600 ( 3,780 ) 1 36/72GB DDS 1 C5709A 880 ( 924 ) StorageWorks DAT40-USB( ) DW022A 60,000 ( 63,000 ) USB 2.0 DDS-4 20/40GB DAT Insight Agent ( ) (1 ) 1 DDS4 150m 40GB 1 C5718A 1,400 ( 1,470 ) 20/40GB DDS 1 C5709A 880 ( 924 ) USB DAT USB 12

LTO ( ) 68 SCSI 2 (Ultra320 SCSI) 68 LTO 1 SCSI 4 68 StorageWorks Ultrium 920( ) E841A 530,000 ( 556,500 ) Ultra320 SCSI 400/800GB LTO ultrium 1 (1 ) P ultrium 800GB RW C7973A 24,000 ( 25,200 ) 400/800GB 1 P ultrium 800GB WORM C7973W 26,000 ( 27,300 ) 400/800GB 1 P ultrium 1 C7978A 7,000 ( 7,350 ) 68 StorageWorks Ultrium 448( ) DW016A 280,000 ( 294,000 ) Wide Ultra3 SCSI 200/400GB LTO ultrium 1 (1 ) ultrium 1 (400GB) C7972A 10,000 ( 10,500 ) 200/400GB P ultrium 1 C7978A 7,000 ( 7,350 ) 68 StorageWorks Ultrium 232( ) DW064A 180,000 ( 189,000 ) Wide Ultra3 SCSI 100/200GB LTO ultrium 1 (1 ) P ultrium 1 (200GB) C7971A 6,400 ( 6,720 ) 100/200GB P ultrium 1 C7978A 7,000 ( 7,350 ) Ultra320 SCSI 2 SCSI 13

DVD-ROM/FD CD-RW/DVD-ROM 331903-B21 20,000 ( 21,000 ) DVD-ROM DVD-ROM 8 DVD-ROM 24 CD-ROM CD-R 24 CD-RW 16 Roxio DVD+R/RW 383975-B21 24,000 ( 25,200 ) CD-R 48 /CD-RW 32 /CD-ROM 48 /DVD 16 / DVD+R DL 8 / DVD+R 16 /DVD-R 16 / DVD-R DL 4 DVD-RW 6 /DVD+RW 8 Roxio CD-ROM DVD-ROM 390164-B21 6,000 ( 6,300 ) 1.44MB/720KB 14

PCI Express NC110T PCI Express Gigabit (10Base-T, 100Base-TX, 1000Base-T) 434905-B21 13,000 ( 13,650 ) PCI Express x1 NC320T PCI Express Gigabit (10Base-T, 100Base-TX, 1000Base-T) 367047-B21 22,000 ( 23,100 ) PCI Express x1 NC360T PCI Express Gigabit (10Base-T, 100Base-TX, 1000Base-T) 412648-B21 34,000 ( 35,700 ) PCI Express x4 NC373T PCI Express Gigabit 394791-B21 36,000 ( 37,800 ) (10Base-T, 100Base-TX, 1000Base-T) PCI Express x4 iscsi TOE RDMA NC380T PCI Express Gigabit 394795-B21 50,000 ( 52,500 ) (10Base-T, 100Base-TX, 1000Base-T) PCI Express x4 iscsi TOE RDMA NC373F PCI Express Gigabit 394793-B21 88,000 ( 92,400 ) (1000Base-SX) PCI Express x4 iscsi TOE RDMA LC PCI Express 10Gbit NC510C PCI Express 10 Gigabit (10GBase-CX4) 414129-B21 240,000 ( 252,000 ) 1 1GB PCI Express x8 NIC NC510F PCI Express 10 Gigabit (10GBase-SR) 414126-B21 480,000 ( 504,000 ) 1 1GB PCI Express x8 NIC LC ML570 G3 4 PCI Express 4 NIC 407481-B22 RDMA Pack 1 (NIC / ) P Web http://h18023.www1.hp.com/support/files/networking/jp/index.html Intelligent Networking Pack Accelerated iscsi Pack RDMA Pack 432046-B21 Networking Software Media Kit NIC 1 512MB 2-8 1GB 9 2GB RDMA RDMA 1 1GB 15

PCI-X NC7782 PCI-X Gigabit (10Base-T, 100Base-TX, 1000Base-T) NC7771 PCI-X Gigabit (10Base-T, 100Base-TX, 1000Base-T) 290563-B21 22,000 ( 23,100 ) NC370T 1000T Gigabit (10Base-T, 100Base-TX, 1000Base-T) 374191-B22 32,000 ( 33,600 ) iscsi TOE RDMA NC7170 PCI-X Gigabit 313881-B21 34,000 ( 35,700 ) (10Base-T, 100Base-TX, 1000Base-T) (10Base-T, 100Base-TX, 1000Base-T) NC340T 4 PCI-X Gigabit 391661-B21 70,000 ( 73,500 ) NC310F PCI-X Gigabit 1000-SX (1000Base-SX) LC 368169-B21 84,000 ( 88,200 ) NC370F 1000SX Gigabit 374193-B22 84,000 ( 88,200 ) (1000Base-SX) iscsi TOE RDMA LC PCI-X 64 /133Mz PCI-X ML570 G3 100Mz 100Mz NIC 407481-B22 RDMA Pack 1 (NIC / ) P Web http://h18023.www1.hp.com/support/files/networking/jp/index.html Intelligent Networking Pack Accelerated iscsi Pack RDMA Pack 432046-B21 Networking Software Media Kit NIC 1 512MB 2-8 1GB 9 2GB RDMA RDMA 1 1GB PCI NC1020 Gigabit (10Base-T, 100Base-TX, 1000Base-T) 353377-B21 11,000 ( 11,550 ) 32 33/66Mz PCI PCI-X PCI PCI PCI-X PCI-X PCI PCI PCI PCI-X PCI-X PCI ( PCI ) NIC ( (SLB TLB) ) NIC NIC 10 100 1000 Base-xx ( ) URL http://h50146.www5.hp.com/products/servers/proliant/support/support_02/support02_03_02.html 16

Integrated Lights-Out(iLO) RJ-45 Integrated Lights-Out(iLO) Integrated Lights-Out (ilo) Advanced Pack CD Integrated Lights-Out (ilo) Advanced Pack 263825-B21 48,000 ( 50,400 ) Integrated Lights-Out(iLO) ( 1 ) Insight Lights-Out Edition / Integrated Lights-Out * 1 OS / RAS * 1 * 1 1 Integrated Lights-Out Integrated Lights-Out(iLO) Advanced Pack ProLiant URL http://h50146.www5.hp.com/products/servers/proliant/essentials/ ProLiant ProLiant 1 URL http://h50087.www5.hp.com/education/course_info.asp?code=ys61311 Insight Lights-Out Edition 227251-371 70,000 ( 73,500 ) 32 PCI 3 2( 64 /100Mz PCI-X ) RJ-45 AC (100V) CD 17

348114-291 60,000 ( 63,000 ) 100V NEMA5-15P 1 2P/2C 2P/4C 348114-B21 60,000 ( 63,000 ) 200V C14-19 1 (10 ) AC200V C14-19 (8 ) 291034-B21 6,000 ( 6,300 ) IEC-IEC C13 UPS PDU 200V UPS PDU UPS PDU C19-20 (2.5m) 295633-B22 6,000 ( 6,300 ) IEC C20 IEC C19 C19 200V UPS 200V 235604-291 6,000 ( 6,300 ) NEMA L6-20P NEMA L6-20R 200V NEMA L6-20P 200V ( ) 348108-B21 20,000 ( 21,000 ) 2P/2C 2P/4C ( ) (6U) 348112-B21 50,000 ( 52,500 ) 348113-B21 50,000 ( 52,500 ) 18

3 SATA 1 9:00 17:00( ) P Care Pack P Care Pack 4 ML570 3 5 4 / 8:45 17:30 ( ) 17:30 4 P Care Pack ProLiant ML570 4 3 UA366E 164,000 172,200 4 4 UA367E 375,000 393,750 4 5 UA368E 587,300 616,665 4 24x7 3 U4592E 411,000 431,550 4 24x7 4 U8121E 700,000 735,000 4 24x7 5 U8087E 989,000 1,038,450 P Care Pack 4 24x7 ML570 3 5 4 24x7 /24 7 ( ) 4 P Care Pack ProLiant (4 4 24x7) () (Named Account Incident Manager) (4 4 24x7) / P Care Pack ProLiant 3 ProLiant UD777E 4 ProLiant UD778E 5 ProLiant UD779E / * 162,000 / 108,000 216,000 / 162,000 270,000 / 216,000 / * 170,100 / 113,400 226,800 / 170,100 283,500 / 226,800 2007.04.30 19 CRT/TFT P UPS 20 CRT/TFT MSA 10 3 4 5 ( ) 24 7 URL http://h50087.www5.hp.com/support/area/index.asp?service=iss P Care Pack (4 4 24x7) DAS P Care Pack URL http://www.hp.com/jp/p_sup P Care Pack URL http://h50146.www5.hp.com/services/ps/carepack/fixed/index.html P Care Pack P Care Pack P Care Pack Web P Care Pack URL http://www.hp.com/jp/carepack/ 19

MEMORY ProLiant ML570 R03 X3660-1M 1P 1GB DIMM 2 1 DIMM DIMM 1 2 3 4 DIMM A B C DIMM DIMM 1 DIMM 2 ( C ) 1GB A B C 1 2 3 4 5 6 1 512MB 512MB 2( ) 3( ) 4( ) 1 57GB A B C 1 2 3 4 5 6 1 512MB 512MB 2GB 2GB 2GB 2GB 2( ) 4GB 4GB 4GB 4GB 3( ) 4GB 4GB 4GB 4GB 4( ) 4GB 4GB 4GB 4GB 2 64GB A B C 1 2 3 4 5 6 1 4GB 4GB 4GB 4GB 2( ) 4GB 4GB 4GB 4GB 3( ) 4GB 4GB 4GB 4GB 4( ) 4GB 4GB 4GB 4GB 1GB (2 512MB PC2-3200 ) 343055-B21 2GB (2 1GB PC2-3200 ) 343056-B21 4GB (2 2GB PC2-3200 ) 343057-B21 4GB (2 2GB PC2-3200 ) 375004-B21 8GB (2 4GB PC2-3200 ) 348106-B21 348107-B21 20

MEMORY ProLiant ML570G3 ProLiant ML570 Generation 3 DC X3/2x2M 2P 2GB SCSI R DIMM 2 1 DIMM DIMM 1 2 3 4 DIMM A B C DIMM DIMM 1 DIMM 2 ( C ) 2GB A B C 1 2 3 4 5 6 1 512MB 512MB 512MB 512MB 2( ) 3( ) 4( ) 1 54GB A B C 1 2 3 4 5 6 1 512MB 512MB 512MB 512MB 2GB 2GB 2( ) 4GB 4GB 4GB 4GB 3( ) 4GB 4GB 4GB 4GB 4( ) 4GB 4GB 4GB 4GB 2 64GB A B C 1 2 3 4 5 6 1 4GB 4GB 4GB 4GB 2( ) 4GB 4GB 4GB 4GB 3( ) 4GB 4GB 4GB 4GB 4( ) 4GB 4GB 4GB 4GB 1GB (2 512MB PC2-3200 ) 343055-B21 2GB (2 1GB PC2-3200 ) 343056-B21 4GB (2 2GB PC2-3200 ) 343057-B21 4GB (2 2GB PC2-3200 ) 375004-B21 8GB (2 4GB PC2-3200 ) 348106-B21 348107-B21 21