Symmetra LX UPS Models 200 V, 4 8 kva 208/240 V, 4 8 kva 220/230/240 V, 4 8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva
- APC TM by Schneider Electric <18 kg <40 lb 18-32 kg 40-70 lb 32-55 kg 70-120 lb >55 kg >120 lb - Symmetra LX 1
Schneider Electric IT Corporation UPS UPS UPS UPS (XLBP) XLBP UPS XLBP UPS 230 V EMC UPS 10 m UPS UPS A UPS 3.5 ma UPS UPS UPS UPS 2 - Symmetra LX
UPS AC DC AC DC OFF OFF / 2 5 APC TM by Schneider Electric - Symmetra LX 3
Symmetra LX PowerView APC by Schneider Electric APC by Schneider Electric Web www.apc.com PowerView PowerView LOAD ON UPS ON BATT BYPASS UPS FAULT UPS PowerView ESC Escape 1? Enter 4 - Symmetra LX
ESC +? + Escape + + Enter 2 1 PowerView RM 1 3 PowerView UPS Esc Chrg 100% Load 20% 206Vin 208Vout 60Hz Runtime: 00hr 27min Esc Control Status >Setup Accessories Logging Display Diags Help 14 Control Status Setup Accessories Logging Display Diagnostics Help Load ON Load OFF UPS APC PowerView - Symmetra LX 5
UPS Symmetra LX UPS 1. UPS AC ON 2. ON a. ON b. UPS UPS PDU ON 3. UPS ON 4. UPS ON AC UPS 4 Chg 100% Load 000% 220 Vin 000 Vout, 60 Hz Runtime 00hr 30min 6 - Symmetra LX
1. Esc Setup ( ) ENTER Control Status >Setup Accessories Logging Display Diags Help 2. Other ( ) ENTER Settings Shutdown Defaults Output Freq Alarms Bypass Copy >Other 3. Output ( ) ENTER ENTER Self Test UPS ID Vout Reporting >Output Enabled UPS_IDEN AUTO 208V - Symmetra LX 7
Symmetra LX 1. Esc Control ( ) ENTER > Control Logging Status Setup Display Diags Accessories Help 2. Turn UPS Output On UPS ENTER Graceful Turn Off Start Runtime Cal >Turn UPS Output On 3. YES ( ) Confirm: Turn UPS On CANCEL >YES, Turn UPS On 4. Start Now UPS HAS BEEN COMMANDED TO TURN LOAD POWER ON 5. 90 LOAD ON UPS LOAD IS ON Press any key 8 - Symmetra LX
UPS 1. Esc > Control Logging Status Setup Accessories Display Diags Help 2. Turn UPS Output Off UPS Graceful Turn Off Start Runtime Cal >Turn UPS Output Off 3. YES ( ) Confirm: Turn UPS Off NO, ABORT >YES, Turn UPS Off UPS HAS BEEN COMMANDED TO TURN LOAD POWER OFF 90 LOAD ON UPS LOAD IS OFF Press any key 4. UPS - Symmetra LX 9
PowerView UPS UPS PowerView UPS UPS 1. ESC' 'Control' > Control Logging Status Setup Accessories Display Diags Help 2. UPS into Bypass UPS >UPS into Bypass Do Self Test Simulate Power Fail Graceful Reboot 3. YES ( ) Confirm: UPS into Bypass NO, ABORT >YES, UPS into Bypass LOAD ON BYPASS UPS IS BYPASSED Press any key 10 - Symmetra LX
ON UPS UPS 1. 2. ON - Symmetra LX 11
PowerView CD APC by Schneider Electric web http://www.apc.com 1. 2. PowerView 3. PowerView 4. UPS PowerView RJ-45 12 - Symmetra LX
5. PowerView UPS RJ-45 PowerView DB-9 UPS RJ-45 6. UPS APC by Schneider Electric web http://www.apc.com/support 7. PowerView 3 Esc Help ENTER 3 LCD 6 1 ESC 8. HyperTerminal 8 1 19,200 bps Xmodem PowerView PowerView 9. PowerView 6 7 10. 11. PowerView RJ-45 12.PowerView RJ-45 UPS 13.2 PowerView 14. 15. 2 UPS PowerView - Symmetra LX 13
PowerView APC by Schneider Electric PowerView UPS UPS Turn UPS Output On/Off Do Self Test Simulate Power Fail(ure) Graceful Reboot Graceful Turn Off Start/Stop Runtime Cal(ibration) UPS into/out of Bypass Setup-Shutdown PowerChute Setup-Shutdown PowerChute 25% 100% 14 - Symmetra LX
PowerView Date/Time dd/mmm/yyyy 11-Aug-2003 hh:mm:ss 21:36:10 Password Password A Z 0 9 _ Timeout 1 2 5 10 ( ) 30 ; 1 2 4 Invalidate UPS Information PowerView Beeper At UPS UPS At Display PowerView + 30 Volume Click Contrast LCD 0 1 2 3 4 5 6 7 Config Fault and Diagnostics (Main) Intelligence Module - Symmetra LX 15
Redundant Intelligence Module Power Modules Batteries PowerView Scroll Up Scroll Down UPS View Log View Statistics Configure Logging Power Events UPS Control 64 ENTER UPS UPS UPS Faults User Activity Measure UPS Events List Event Groups Power Events UPS Control Events User Activities UPS Fault Measure UPS Events Clear Log 16 - Symmetra LX
Ø Vin Vout Iout % load assuming no redundancy % load allowing for n+ redundancy Frequencies Battery Status Screen Power Module Status Screen Alarm Thresholds Status Screen Miscellaneous Status Screen 4 1 3 > > UPS Shutdown Defaults Low Batt(ery) Dur(ation) Shutdown Delay Return Delay Return Battery Capacity UPS 25 7 10 12 15 18 20 0 20 60 120 240 480 720 960 020 60 120 240 480 720 960 015 25 35 50 60 75 90 - Symmetra LX 17
Output Freq(uency) UPS 50 ± 3 Hz 50 ± 0.1 Hz 60 ± 3 Hz 60 ± 0.1 Hz Alarms Redundancy 01 2 Bypass Copy Other Load Runtime Self Test UPS ID Output Vout Reporting UPS : UPS UPS UPS UPS 8 1 2 3 4 5 6 7 8 9 10 12 kva 0:05 10 15 30 45 1 2 3 4 5 6 7 8 UPS UPS 7 14 / 200 V / 208 V / 240 V 220 V / 230 V / 240 V 18 - Symmetra LX
PowerView PowerView UPS APC by Schneider Electric APC by Schneider Electric web http://www.apc.com PowerView #Pwr modules changed since last ON. Pwr ON 1 UPS #Batteries changed since last ON. Pwr ON 1 UPS No Redundant Intelligence Module (IM). IM IM 2 IM Batt capacity less than Return Batt Cap. UPS 1 2 Input Freq outside configured range. UPS 1 2 PowerView (Startup>Setup>OuputFreq) 3 AC adequate for UPS but not for bypass. UPS 1 2 Low/No AC input, start-up on battery. UPS UPS 1 2 - Symmetra LX 19
PowerView # of batteries increased. 1 # of batteries decreased. 1 # of Pwr Modules increased. 1 Intelligence Module inserted. Intelligence Module removed. Redundant Intelligence Module inserted. Redundant Intelligence Module removed. # of External Battery Cabinets increased. # of External Battery Cabinets decreased. Redundancy Restored. Redundancy Restored. Load is No Longer above Alarm Threshold. Min Runtime restored. IM IM IM IM 1 1 UPS 20 - Symmetra LX
PowerView Bad Battery Module. Bad Power Module. Intelligence Module is installed and failed. Redundant Intelligence Module is installed and failed. Load is above kva alarm threshold. Redundancy has been lost. Redundancy is below alarm threshold. IM IM UPS Symmetra LX Physical 1 2 PowerView 1 2 3 0 (Startup > Setup > Alarms > Redundancy > Zero) 1 2 3 PowerView (Startup > Setup > Alarms > Redundancy) Runtime is below alarm threshold. 1 2 3 4 PowerView (Startup > Setup > Alarms > Runtime) - Symmetra LX 21
PowerView Bypass is not in range (either freq or voltage). UPS 1 (Startup>Setup>OutputFreq) 2 Bypass contactor stuck in bypass position. Bypass contactor stuck in online position. UPS UPS APC by Schneider Electric UPS has detected an internal fault and is in bypass mode. UPS UPS in bypass due to overload. UPS 1 2 System is in Maintenance Bypass. UPS On Battery. UPS UPS Need Bat Replacement. 1 UPS Fault. UPS APC by Schneider Electric Shutdown or unable to transfer to Batt due to overload. UPS 1 2 3 22 - Symmetra LX
PowerView Load Shutdown from Bypass.Input Freq/Volts outside limits. Fault, Battery Charger Failure. Fault, Bypass Relay Malfunction. Fault, Internal Temp exceeded normal limits. Input circuit breaker tripped open. System level fan failed. The Redundant Intelligence Module (IM) is in control. IIC inter-module communications failed. UPS 1 1 UPS UPS UPS IM IM MIM 1 APC by Schneider Electric 1 2 APC by Schneider Electric APC by Schneider Electric APC by Schneider Electric - Symmetra LX 23
UPS 1. 2. UPS 3. APC by Schneider Electric web http://www.apc.com a. UPS RMA b. 4. UPS APC Web 5. UPS 6. RMA APC by Schneider Electric web http://www.apc.com APC 24 - Symmetra LX
APC by Schneider Electric APC by Schneider Electric APC by Schneider Electric Web APC by Schneider Electric Knowledge Base www.apc.com APC by Schneider Electric Web www.apc.com/support/ APC by Schneider Electric Knowledge Base esupport APC by Schneider Electric E-mail www.apc.com/support/contact APC by Schneider Electric APC by Schneider Electric 2018 APC by Schneider Electric.APC APC Smart-UPS Symmetra Schneider Electric Industries S.A.S. JA 990-1546B-003 05/2018