LSI MegaRAID SAS-MFI BIOS Version x.xx.xx (Build xxxx xx, xxxx) Copyright (c) xxxx LSI Corporation HA -0 (Bus xx Dev x) LSI MegaRAID SAS xxxxxxx FW package: x.x.x-xxxx x Virtual Drive(s) found on the host adapter. x Virtual Drive(s) handled by BIOS Press <Ctrl><H> for WebBIOS Your VDs that configured for write-back are temporarily running in write-through mode. This is caused by the battery being charged, missing or bad. Please allow the battery to charge for 24 hours before evaluating the battery for replacement. The following VDs are affected: X Press any key to continue.
LSI MegaRAID SAS-MFI BIOS Version x.xx.xx (Build xxxx xx, xxxx) Copyright (c) xxxx LSI Corporation HA -0 (Bus xx Dev x) LSI MegaRAID SAS xxxxxxx FW package: x.x.x-xxxx x Virtual Drive(s) found on the host adapter. x Virtual Drive(s) handled by BIOS Press <Ctrl><H> for WebBIOS Your VDs that configured for write-back are temporarily running in write-through mode. This is caused by the battery being charged, missing or bad. Please allow the battery to charge for 24 hours before evaluating the battery for replacement. The following VDs are affected: X Press any key to continue.
MegaRAID WebBIOS Controller Selection Advanced Software Options Controller Selection *1 Controller Properties Scan Devices Virtual Drives Drives Configuration Wizard Physical View/Logical View Events Exit MegaRAID WebBIOS
-
xx Virtual drive(s) Configured. Array# Mode Stripe Size No.Of Stripes Drive Size Status 00 RAID1 64KB 02 xxxxmb online Press Ctrl-M or Enter to run LSI Software RAID Setup Utility. Management Menu Configure Initialize Objects Rebuild Check Consistency
Exit? YES NO Press <CTRL><ALT><DEL> To Reboot The System
A B C D E Management Menu Configure Initialize Objects Rebuild Check Consistency
A B C Objects Adapter Virtual Drive Physical Drive A B C D E F G H I J K L M Rebuild Rate Chk Const Rate FGI Rate BGI Rate Disk WC Read Ahead Bios State Cont On Error Fast Init Auto Rebuild Auto Resume Disk Coercion Factory Default Adapter 0 = 30 = 30 = 30 = 30 = Off = Off = Enable = Yes = Disable = Off = Enable = None
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Proceed? YES NO
Nothing More To Configure Press Any Key To Continue A-0 A-0 Span-x
Warning! This May Result In Data Loss When Power Fails Press Any key to Continue
Save Configuration? Yes No Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Virtual Drives Virtual Drive 0 Virtual Drive(s) Configured VD RAID Size #Stripes StripeSz State 0 1 xxxxxmb 2 64 KB ONLINE Virtual Drives Virtual Drive 0 Initialize? Yes No
Init of VD Is In Progress VD 0 Initialization. Press Esc to Abort 54 % Completed Stop(S), Continue(C), Or Abort(A) The Initialization Process?
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive Clear Configuration? Yes No
Want To Delete A VD? Yes No
Virtual Drives Virtual Drive 0 Virtual Drive(s) Configured VD RAID Size #Stripes StripeSz State 0 1 xxxxxmb 2 64 KB ONLINE Virtual Drives Virtual Drive 0 Consistency Check? Yes No
CC Under Progress VD 0 Consistency Check. Press Esc to Abort. / 0 % Completed Stop(S), Continue(C), Or Abort(A) The CC Process?
Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)? REBUILDING Rebuilding Of Drive 1 Under Progress. Press Esc To Abort. 0 % Completed Stop(S), Continue(C), Or Abort(A) The Rebuild Process?
Physical Drive Information (Port # 0) Device Identi cation Device Type Capacity Product ID Revision No Link Speed : DISK : xxxxxmb : xxxxxxxxxx : xxxx : xxx Gbps Press Any Key To Continue
Waning! Chosen Cache Setting Will Be Applied To All The VDs In This Array Press Any Key To Continue