2
ID
0 1 3 4 2 5
1 2 2 1
0 3 1 4 2 5 A
2 1 1 2
0 3 1 4 2 5
Press <F2> to enter SETUP, <F12> to Netork Press <Ctrl> <A> for SCSISelect(TM) Utility!
0 3 1 4 2 5
0 1 3 4 2 5
1 2 0 1 2
1 1 2
2 1
2 4 3 1
0 3 1 4 2 5
PULL AIR PULL AIR 1 2 3 1 2 3
PULL AIR PULL AIR
Press <F2> to enter SETUP Enter passord [ ]
Main System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Poer ON Delay Time: Platform Event Filtering: PhoenixBIOS Setup Utility Advanced Security Server Boot Exit [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to vie server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit System Time: System Date: Hard Disk Pre-Delay: Primary IDE Master Primary IDE Slave Secondary IDE Master Secondary IDE Slave [14:18:58] [10/04/2007] [Disabled] [CD-ROM] [None] [None] [None] Item Specific Help <Tab>, <Shift-Tab>, or <Enter> selects field. Processor Settings Language: [English (US)] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit ç ñ
Main PhoenixBIOS Setup Utility Processor Settings Item Specific Help Processor Retest: CPU Speed: Processor 1 CPUID: Processor 1 L2 Cache: Processor 2 CPUID: Execute Disable Bit: Virtualization Technology: C1 Enhanced Mode: Intel SpeedStep(R) Technology: Hardare Prefetcher: Adjacent Cache Line Prefetch: [No] 1600 MHz 06F6 4096 KB Not Installed [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Select 'Yes', BIOS ill clear historical processor status and retest all processors on next boot. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Item Specific Help Memory Configuration PCI Configuration Peripheral Configuraion Advanced Chipset Control Additional setup menus to configure Memory devices. Boot-time Diagnostic Screen: Reset Configuration Data: NumLock: Memory/Processor Error: [Disabled] [No] [Off] [Boot] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Memory Configuration Item Specific Help System Memory: Extended Memory: DIMM Group #1 Status: DIMM Group #2 Status: DIMM Group #3 Status: DIMM Group #4 Status: DIMM Group #5 Status: DIMM Group #6 Status: Memory Retest: Extended RAM Step: Memory RAS Feature: Sparing: 601 KB 522752 KB Normal Normal Normal Normal Normal Normal [No] [Disabled] [Interleave] [Disabled] Enables DIMM sparing feature. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility PCI Configuration Item Specific Help Onboard Video Controller Onboard LAN PCI Slot 1B Option ROM: PCI Slot 1C Option ROM: [Enabled] [Enabled] Additional setup menus to configure onboard Video controller. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port A: Base I/O address: Interrupt: Serial Port B: Base I/O address: Interrupt: USB Controller: USB 2.0 Controller: Parallel ATA: Serial ATA: SATA Controller Mode Option: SATA AHCI: [Enabled] [3F8h] [IRQ 4] [Enabled] [2F8h] [IRQ 3] [Enabled] [Enabled] [Enabled] [Enabled] [Enhanced] [Enabled] Configure Serial Port using options: [Disabled] No configuration [Enabled] User configuration F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Advanced PhoenixBIOS Setup Utility Advanced Chipset Control Item Specific Help Multimedia Timer: Intel (R) I/O AT: Wake On Ring: Wake On RTC Alarm: [Disabled] [Enabled] [Disabled] [Disabled] Enable/Disable Multimedia Timer (HPET). F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Main Advanced PhoenixBIOS Setup Utility Security Server Boot Exit User Passord Is: Supervisor Passord Is: Set User Passord Set Supervisor Passord Clear Clear [Enter] [Enter] Item Specific Help Supervisor Passord controls access to the setup utility. Passord on boot: Fixed disk boot sector: Poer Sitch Inhibit: Security Chip Configuration [Disabled] [Normal] [Disabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Security Security Chip Configuration Item Specific Help TPM Support: Current TPM State: Change TPM State: [Enabled] Disabled and Deactivated [No Change] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Physical Presence operations TPM configuration change as requested to State: Enable & Activate Note: This action ill sitch on the TPM Reject Execute Physical Presence operations TPM configuration change as requested to State: Deactivate & Disable Note: This action ill sitch off the TPM WARNING!!! Doing so might prevent security applications that rely on the TPM from functioning as expected Reject Execute Physical Presence operations TPM configuration change as requested to State: Deactivate & Disable Note: This action ill sitch off the TPM WARNING!!! Doing so might prevent security applications that rely on the TPM from functioning as expected Reject Execute
Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit System Management Console Redirection BMC LAN Configuration Event Log Configuration Assert NMI on PERR: Assert NMI on SERR: FRB-2 Policy: Boot Monitoring: Boot Monitoring Policy: Thermal Sensor: BMC IRQ: Post Error Pause: AC-LINK: Poer ON Delay Time: Platform Event Filtering: [Enabled] [Enabled] [Retry 3 Times] [Disabled] [Retry 3times] [Enabled] [IRQ 11] [Enabled] [Last State] [ 20] [Enabled] Item Specific Help Additional setup menus to vie server management features. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server System Management Item Specific Help BIOS Version: Board Part Number: Board Serial Number: System Part Number: System Serial Number: Chassis Part Number: Chassis Serial Number: Onboard LAN1 MAC Address: Onboard LAN2 MAC Address: Management LAN MAC Address: BMC Device ID: BMC Device Revision: BMC Firmare Revision: SDR Revision: xxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xxxxxxx-xxxxxxxx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx xx-xx-xx-xx-xx-xx 01 01 01.00 01.00 All items on this meenu cannot be modified in user mode. If any items require changes, please consult your system Supervisor. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server Console Redirection Item Specific Help BIOS Redirection Port: Baud Rate: Flo Control: Terminal Type: Continue Redirection after POST: Remote Console Reset: [Disabled] [19.2K] [CTS/RTS] [VT100+] [Enabled] [Disabled] Selects the Serial port to use for Console Redirection. Disabled completely disables Console Redirection. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server BMC LAN Configuration Item Specific Help IP Address IP Subnet Mask Default Gateay DHCP: [192.168.001.001] [255.255.255.000] [000.000.000.000] [Disabled] Display IP Address. Web Interface HTTP: HTTP Port Number: HTTPS: HTTPS Port Number: Command Line Interface Telnet: Telnet Port Number: SSH: [Disabled] [ 80] [Disabled] [ 443] [Disabled] [ 23] [Disabled] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server System Event Log Event Log Configuration Setup Notice If you select "System Event Log" menu belo, it may take a fe minutes to display. Item Specific Help Display the System Event Log Clear All Event Logs: [Enter] F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Server System Event Log Item Specific Help SEL Entry Number = SEL Record ID = SEL Record Type = Timestamp = Generator ID = SEL Message Rev = Sensor Type = Sensor Number = SEL Event Type = Event Description = SEL Event Data = 1/121 0904 02 - System Event Record 2007/08/05 10:58:28 20 00 04 12 - System Event 87 - System Event 6F - Sensor specific OEM System Boot Event 41 8F FF This is an entry The System Event Log. Eyes used to vie. Up arro :Neer SEL Don arro :Older SEL <->:Neer SEL <+>:Older SEL Home:Neer SEL End :Older SEL F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit 1: USB CDROM: 2: IDE CD: MATSHITADVD-ROM SR-8178-(P 3: USB FDC: 4: USB KEY: 5: IDE HDD: 6: PCI SCSI: #D50 ID06 LUN0 SEAGATE ST 7: PCI BEV: IBA GE Slot 0C01 v0007 8: : PCI SCSI: #D50 ID07 LUN0 SEAGATE ST : PCI SCSI: #D50 ID08 LUN0 SEAGATE ST : PCI SCSI: #D50 ID09 LUN0 SEAGATE ST : PCI SCSI: #D50 ID0A LUN0 SEAGATE ST : PCI SCSI: #D50 ID0B LUN0 SEAGATE ST : USB HDD: : PCI BEV: IBA GE Slot 0C01 v0007 Item Specific Help Keys used to vie or configure devices: Up and Don arros select a device. <+> and <-> moves the device up or don. <x> exclude or include the device to boot. <Shift + 1> enables or disables a device. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select Sub-Menu F10 Save and Exit
Main PhoenixBIOS Setup Utility Advanced Security Server Boot Exit Exit Saving Changes Exit Discarding Changes Load Setup Defaults Load Custom Defaults Save Custom Defaults Disacard Changes Save Changes [Enter] [Enter] Item Specific Help Exit System Setup and save your changes to CMOS. F1 Help Select Item - /+ Change Values F9 Setup Defaults Esc Exit Select Menu Enter Execute Command F10 Save and Exit
1 2 3 1 2 3 1 2 3 1 2 3
Adapter Selection Adapter No. Bus No Device No Type Firmare Version 0. XX XX MegaRAID SAS 8708EM2 X.XX.XX - XXXX Start
0 3 1 4 2 5