Microsoft PowerPoint - SWTW2014_SV TCL 3D TSV Cu Pillar Challenges_Experience_akn.ppt

Similar documents
JOURNAL OF THE JAPANESE ASSOCIATION FOR PETROLEUM TECHNOLOGY VOL. 66, NO. 6 (Nov., 2001) (Received August 10, 2001; accepted November 9, 2001) Alterna

錫-亜鉛-アルミニウム系鉛フリーはんだの実用化

Microsoft Word - PCM TL-Ed.4.4(特定電気用品適合性検査申込のご案内)

(1 ) (2 ) Table 1. Details of each bar group sheared simultaneously (major shearing unit). 208

The Evaluation on Impact Strength of Structural Elements by Means of Drop Weight Test Elastic Response and Elastic Limit by Hiroshi Maenaka, Member Sh



0801297,繊維学会ファイバ11月号/報文-01-青山

The Effect of the Circumferential Temperature Change on the Change in the Strain Energy of Carbon Steel during the Rotatory Bending Fatigue Test by Ch

On the Wireless Beam of Short Electric Waves. (VII) (A New Electric Wave Projector.) By S. UDA, Member (Tohoku Imperial University.) Abstract. A new e

パナソニック技報

Vol. 48 No. 3 Mar PM PM PMBOK PM PM PM PM PM A Proposal and Its Demonstration of Developing System for Project Managers through University-Indus

NO

自分の天職をつかめ


スライド 1

J. Jpn. Inst. Light Met. 65(6): (2015)

<30372D985F95B62D8E52967B8C4F8E7190E690B62E706466>

A Study on Throw Simulation for Baseball Pitching Machine with Rollers and Its Optimization Shinobu SAKAI*5, Yuichiro KITAGAWA, Ryo KANAI and Juhachi

Fig. 4. Configuration of fatigue test specimen. Table I. Mechanical property of test materials. Table II. Full scale fatigue test conditions and test


II

環境負荷低減に向けた低温接合技術

_念3)医療2009_夏.indd

16_.....E...._.I.v2006

ï\éÜA4*

Microsoft Word - Meta70_Preferences.doc



Study on Application of the cos a Method to Neutron Stress Measurement Toshihiko SASAKI*3 and Yukio HIROSE Department of Materials Science and Enginee

<95DB8C9288E397C389C88A E696E6462>

Steel Construction Vol. 6 No. 22(June 1999) Engineering

Visual Evaluation of Polka-dot Patterns Yoojin LEE and Nobuko NARUSE * Granduate School of Bunka Women's University, and * Faculty of Fashion Science,

IPSJ SIG Technical Report Vol.2016-CE-137 No /12/ e β /α α β β / α A judgment method of difficulty of task for a learner using simple

テストコスト抑制のための技術課題-DFTとATEの観点から

Fig. 1. Relation between fatigue crack propagation rate and stress intensity factor range. Fig. 2. Effect of stress ratio on fatigue crack opening rat

電子部品はんだ接合部の熱疲労寿命解析

Title 泌尿器科領域に於ける17-Ketosteroidの研究 17-Ketosteroidの臨床的研究 第 III 篇 : 尿 Author(s) 卜部, 敏入 Citation 泌尿器科紀要 (1958), 4(1): 3-31 Issue Date URL

企業の信頼性を通じたブランド構築に関する考察


52-2.indb

24 Depth scaling of binocular stereopsis by observer s own movements

soturon.dvi

UDC : ' : '24' : '24'26' : : A Study of Condition of Pits Formation and Their Fe


Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

(43) Vol.33, No.6(1977) T-239 MUTUAL DIFFUSION AND CHANGE OF THE FINE STRUCTURE OF WET SPUN ANTI-PILLING ACRYLIC FIBER DURING COAGULATION, DRAWING AND


Microsoft Word - Win-Outlook.docx

鉛フリー無電解Niめっき皮膜中の共析物がはんだ実装信頼性に及ぼす影響

Continuous Cooling Transformation Diagrams for Welding of Mn-Si Type 2H Steels. Harujiro Sekiguchi and Michio Inagaki Synopsis: The authors performed

大学論集第42号本文.indb

Corrections of the Results of Airborne Monitoring Surveys by MEXT and Ibaraki Prefecture

Contents Launching of the Thailand-Japan Longstay Promotion Association Longstay and establishing the Thailand-Japan Longstay Promotion Association Re

-2-

1 Fig. 1 Extraction of motion,.,,, 4,,, 3., 1, 2. 2.,. CHLAC,. 2.1,. (256 ).,., CHLAC. CHLAC, HLAC. 2.3 (HLAC ) r,.,. HLAC. N. 2 HLAC Fig. 2

Fig, 1. Waveform of the short-circuit current peculiar to a metal. Fig. 2. Waveform of arc short-circuit current. 398 T. IEE Japan, Vol. 113-B, No. 4,

LC304_manual.ai


1 2 3

.N..

P036-P041

Journal of Geography 116 (6) Configuration of Rapid Digital Mapping System Using Tablet PC and its Application to Obtaining Ground Truth

Bull. of Nippon Sport Sci. Univ. 47 (1) Devising musical expression in teaching methods for elementary music An attempt at shared teaching

2

The Evaluation of LBB Behavior and Crack Opening Displacement on Statically Indeterminate Piping System Subjected to Monotonic Load The plastic collap

1..FEM FEM 3. 4.

車両開発における構造・機構のCAE

特-4.indd

Fig. 1 Sampling positions from the ingot. Table 2 Chemical compositions of base metal (%) Fig. 2 (unit: mm) Shape and size of fatigue test specimen. T



,


2001 Received November 28, 2014 Current status and long-term changes of the physique and physical fitness of female university students Shiho Hiraku Y

CONTENTS Public relations brochure of Higashikawa September No.755 2

第4回 JISSスポーツ科学会議 ポスターセッション


AND9137JP - SO8FLパッケージ用ユニバーサル・フットプリント




Transcription:

3D TSV Cu Pillar Probing Challenges & Experience 3 次元 TSV プロービングの課題と経験 Ray Grimm/Mohamed Hegazy SV TCL An SV Probe Company Linjianjun (David) Hi Silicon Rick Chen SPIL

The Challenges 2

Cu Pillar Bump Reliability Shear Test Each Assembly/Packaging house has done many DOEs & optimized their bump geometry, UBM, PI thickness to optimize reliability. Reliability Test Bump Structure Corner Corner Fig 1. Stress Point after FC Attach Reflow Fig 2. Stress Point After Assembly 3

Cu Pillar Bump Probing w/staggered Probe High Risk of Peeling & Fracture Failures: 剥がれ 破断不良のリスク Bump shear tests were performed as per the JEDEC standards (JEDD22-B117).: バンプせん断試験は JEDEC 規格 (JEDD22-B117) に従って実施した For Bump Shear Test, the wedge force at 20%~30% of Total Height of Pillar Eg.TH= 80µm, shear test start at 25µm & the other to solder cap at 70µm. After the shear test was complete, the next step is for TCT Thermal Cycle for 1000 cycles, and results were observed to be passing. If the geometry is not optimized then fractures will show up on the stress points. Same concept was performed if probing on 2 different conditions 70µm 25µm Shear Force Test Spec >7mgf/µm 2 Optimum Probe High Risk Probe shear force apply on stress point. 4

The SV TCL Experience 5

Recap of previous activities Case #1 :2010 Copper Pillar & Bump Probing Engineering lab tests Case #2: 2012 50µm Pitch Array w/logictouch First trial on customer wafer 6

Case #1 Copper Pillar & Bump Probing Internal Work to Study Contact Behavior of Cu pillar Bumps at 60µm Pitch with Various Solder Cap Materials: 60um ピッチバンプ : Cu pillar with Eutectic Solder Cap: 共晶はんだ Cu pillar with Lead free Solder Cap: 鉛フリーはんだ Cu pillars Demonstrated : 実証 Critical stress points and mechanical failure mechanisms of the probe card as well as the Cu Pillar : 機械的不良 Critical parameters to achieve reliable and stable contact to different configurations : 問題となるパラメータ Presented at SWTW 2010 Eutectic Cap Direct on Cu Lead Free Cap 7

Case #2 50µm Pitch Array w/logictouch Co presented with ASE at SWTW 2012 8

So where have we gone since SWTW 2010 and 2012? SWTW2010,2012 以後の結果 9

Case#3 Production Reliability DOE Huawei/Hi Silicon/SPIL Cu Pillar + Solder Cap Probe Mark DOE Mobile Chip Hi3620 10

DOE set up 11

Probe Mark Size Sampling Plan 12

Probe Mark Size Analysis 13

RVSI Inspection Robotic vision bump inspection system 14

Die Test Results No Bin shifting observed Stability shown even with increasing TD and OD 15

Probe Mark SEM Verification 16

Ion Miller Verification of Low K Layer No Low K cracking observed 17

X Ray Results No Abnormality observed 18

C SAM Results C Mode Scanning Acoustic Microscope No Abnormality observed 19

No Abnormality observed T Ray Results Terahertz Radiation 20

Current Status : 現状 High yield observed : 高いイールド 98% Die yield 99% Mechanical bump damage yield 2 more Devices successfully completed reliability testing: 追加 2 デバイスの信頼性テスト良好 More than 10 devices are in full production:10 以上のデバイスを量産使用 21

Lifetime study versus actual 針寿命の考察結果 22

Probe mark and expected life time with aggressive clean Trio2milFlat pitch@80um Customer Patrs_ID Device # Close die Test Site Initial tip extension Current Tip extension Current TDs TDs per mil of tip extension loss Life expectanc y in TDs HIS HI0007 HI-3516 2 1317 2 18.26 16.67 135,736 85,369 875,881 1-Obtain initial and current tip extension and TDs 2-Obtain TDs per mil of tip extension loss 3-Obtain life expectancy based on available tip extension and TDs per mil of tip extension loss 23

Actual life time with optimized clean Trio2milFlat pitch@80um 1,921,787 TDs 2 Million TDs! 24

Summary: まとめ Copper pillar probing requires not only electrical considerations, but also very precise mechanical probing techniques: 銅ピラープローブは 電気的考慮だけでなく 非常に精密な機械特性測定技術を必要とする The positional accuracy of the probe contacts to the copper pillar is critical to prevent shearing and fractures during probing: 銅ピラーに対するプローブコンタクトの位置合わせが プロービング時の剪断および破断を防止するために重要である 2 mil Trio probe contacts are an ideal solution for copper pillar applications: 2ミルのTrioプローブは銅ピラー アプリケーションに理想的なソリューションである Low cost: 低コスト Tried and proven technology: 実証済み技術 Repairable: リペア可能 Short lead time to market: 短納期 25