NSR-500 Software Update Installation Procedures

Similar documents
NSR-500 Installation Guide

NSR-500 Create DVD Installer Procedures

Microsoft Word - Win-Outlook.docx

fx-9860G Manager PLUS_J

Microsoft Word - KUINS-Air_W10_ docx

NSR-500 Create USB Installer Procedures

Microsoft Word - KUINS-Air_W8.1_ docx

ドライバインストールガイド

How to Use In-flight Wi-Fi service ご利用ガイド 3 Flight Plan will be available for international connecting flights within 24 hours. 3 フライトプランは24時間以内であれば 国際

入学検定料支払方法の案内 1. 入学検定料支払い用ページにアクセス ポータルの入学検定料支払いフォームから 入学検定料支払い用 URL の ここをクリック / Click here をクリックしてください クリックを行うと 入学検定料支払い用のページが新たに開かれます ( 検定料支払い用ページは ポ

Actual ESS Adapterの使用について

ServerView with Data ONTAP-v™ PowerChute® Network Shutdown 設定について

HA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2

Introduction Purpose This training course demonstrates the use of the High-performance Embedded Workshop (HEW), a key tool for developing software for

V-SFTのインストール及び画面データの転送手順 V-SFT Installation and Screen Data Transfer Procedure

HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル

TOOLS for UR44 Release Notes for Windows

BS・110度CSデジタルハイビジョンチューナー P-TU1000JS取扱説明書

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

LC304_manual.ai

Microsoft Word - PrivateAccess_UM.docx

学部ゼミ新規申請方法 (Blackboard 9.1) Seminar Application Method for Undergraduate Seminar Courses ゼミ新規申請は Blackboard で受け付けます! 次セメスターにゼミ履修を希望する学生は 下記マニュアルに従ってゼミ

1 142

% + RP-BC30 BATTERY CHARGER STAND K -! # % $ $ % % # $ $ $ %

C-720 Ultra Zoom 取扱説明書

FTDI Driver Error and Recovery Procedure Check FTDI driver operation Rev :OK, Rev :NG, Rev :NG May 11, 2017 CHECK FTDI DRIVER

0 C C C C C C C

Diskette Drive Installation

UR28M/UR824/UR44/UR12/UR22mkII Firm UG

UR28MUR824UR44UR22mkII Firmware Update Guide

AMT機能セットアップガイド

< 付録A: ソフトウェアアップデート >

1 138

Diskette Drive Installation

MENU 키를 누르면 아래의 화면이 나타납니다

2

1 122

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

取扱説明書_KX-PW100CL

Microsoft PowerPoint - Ritsu-Mate出願操作マニュアル(学部英語版) _STEP4.pptx

ダウンロードサイト利用説明書(利用者)

Microsoft Word - DWR-S01D_Updater_取扱説明書_120514A.doc

この手順は AVT-C281J の製品のファームウェアバージョン又は MCU バージョンをアップデートする為のものです 作業には必ず PC 上で事前準備が必要になります お手数ではございますが下記手順に従って作業をしていただけます様にお願いいたします [ ご準備いただくもの ] 作業用 PC (Wi

この手順はAVT-C281Lの製品のファームウェアバージョン又はMCUバージョンをアップデートする為のものです 作業には必ず PC 上で事前準備が必要になります お手数ではございますが下記手順に従って作業をしていただけます様にお願いいたします [ ご準備いただくもの ] 作業用 PC (Window

2

2 3

0 C C C C C C

取説_KX-PW38CL_PW48CL

by CASIO W61CA For Those Requiring an English/Chinese Instruction

RR-US470 (RQCA1588).indd

プレインストールOSリカバリ手順書

取説_KX-PW101CL_PW102CW

MOTIF XF 取扱説明書

Contents Logging in 3-14 Downloading files from e-ijlp 15 Submitting files on e-ijlp Sending messages to instructors Setting up automatic

Steinberg AXR4T Firmware Update Guide


WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

Fortinet社

Microsoft Word - DUC登録方法.doc

H8000操作編

Microsoft Word - JAPANESE - Setup Login Credentials.doc

DWR-S01D Updater 取扱説明書 発行日 :2011/2/28

HP ThinUpdateを使用したWESシンクライアントイメージリストア手順書


iSCSI ストレージ機器のセットアップ手順

Z7000操作編_本文.indb

BGI PDF

Microsoft Word - README_2011_FW.txt


2 3

はじめに このドキュメントではftServerに関する障害調査を行う際に 必要となるログ データの取得方法を説明しています ログ データの取得には 初期解析用のデータの取得方法と 詳細な調査を行うときのデータ取得方法があります 特別な理由でOS 側のログが必要となった場合には RHELログの取得につ


Microsoft Word - PPTP-manual(MacOS)_ _revised(E)

OUTSIDE FRONT COVER Setup Guide セットアップ ガイド C M Y K PMS 3005

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

BIOSセットアップメニュー 一覧

目次 1. HLA Fusion 3.0 がインストール可能な環境 HLA Fusion 3.0 のインストール HLA Fusion 3.4 のインストール 初期設定用データベース接続 ( 初めての方のみ ) 既存データベースのUpg

2. 投稿マニュアル.xlsm

*Ł\”ƒ‚ä(DCH800)

任意の間隔での FTP 画像送信イベントの設定方法 はじめに 本ドキュメントでは AXIS ネットワークカメラ / ビデオエンコーダにおいて任意の間隔で画像を FTP サー バーへ送信するイベントの設定手順を説明します 設定手順手順 1:AXIS ネットワークカメラ / ビデオエンコーダの設定ページ

クライアント証明書申請 インストール方法 Client certificate application and installation manual 2018 年 6 月 目次 [Table of Contents] はじめに [About This Manual] クライアント証明

SMA 400 / 200 商品入荷時のファームウェアのインストール手順 エンドユーザ様向け

2

Manual_Win81_JP.md

PCI Express Graphics Products

US40cユーザーズガイド

ETH0 と ETH1 はそれぞれ独立した IP アドレスを持っているので 指定のブラウザのアドレスバーに対 応した IP アドレスを入力し アクセスします 万が一アクセスできない場合には 最終章の 困ったときは を参照ください ユニットの WebGUI にログイン Chrome を開き シークレッ

Flash Loader


LC-24_22_19K30.indb

Microsoft Word - D JP.docx



2

2

2

ソフトウェアの更新ユーザーガイド

IPCClient(英語)の使用方法

Transcription:

NSR Software Update Installation Procedures Overview Handle this information with care because this installation procedure is not intended for use by customers. This document describes software update installation procedures for NSR-500. Update installation provides more function and support of more camera models. And it improves software bugs. The effectiveness of update installation is different in each software version. You should confirm the release note before update installation. And configuration data and recording data remain after update installation. Applicable Model NSR-500 Series To Be Required - Either of the followings Install-USB-Device (*1) Install-DVD (*1) and DVD-Drive with USB interface - USB keyboard (*2) Note. (*1) Please refer to Create USB install media ( Installer for USB )or Create DVD install media ( Installer for DVD ). Installer for USB, Installer for DVD (at Software Download ) http://www.sony.net/products/ipela/nsr/nsr500/ (*2) Use a general USB keyboard. The one with special keys, buttons or sticks may not work. 1

NSR Software Update Installation Procedures Procedures 1. Connect Install-USB-Device or DVD Drive into which Install-DVD is inserted. Then push power button to start up. 2. Press u key. Note. If you can not see the above message, there may be problem in your installation device. In the case of Install-USB-Device, if you change USB memory to other one, you may be able to see the above. In the case of Install-DVD, if you change DVD drive or install-dvd to others, you may be able to do it. A confirmation message may appear. Please click y in that case. 2

NSR Software Update Installation Procedures 3. System will start to update bios and software in HDD. Note. After there has been no input over several minutes, screen saver runs and nothing is displayed on the screen. If you want to display the screen again, please press Enter key. 4. In the case of Install-USB-Device, the following message is displayed after this installation completed. Disconnect Install-USB-Device. Then press space key to shutdown system. In the case of install-dvd, system is shut down automatically after this installation completed. Disconnect DVD drive. 3

NSR Software Update Installation Procedures 5. Push power button to continue installation procedures. Wait until finishing the procedure of NSR Application installation. It may take several munities. 6. After the procedure of 5, rebooting is started automatically. If you had executed setup wizard before update installation, login screen will be displayed. Proceed to the next step. If you have not executed it, the screen of setup wizard will be displayed. Execute setup wizard. (Refer Installation Manual of NSR-500) Proceed to the next step after that. Note. File system checking and repairing will be executed on boot time. Although the message Not safe last power off - begin filesystem repair may be displayed on boot splash, however there is no side effect to filesystem. Please wait for finishing the process. (15min at the most) 7. Confirm software version. (Refer User Guide of NSR-500) Please go to the procedure step-12 for version 1.3.0 or higher. 8. Configure setting related UPS on setup menu regardless of using UPS in every update installation. When you will not use UPS, select Disable and push OK button to finish reconfiguration. (Refer User Guide of NSR-500) 9. Configure setting of Audio on setup menu in every update installation. When there is no change for audio configuration, push OK button to finish reconfiguration. When only AUDIO OUT can be selected, do the same. (Refer User Guide of NSR-500) 4

NSR Software Update Installation Procedures 10. In the case of recording to iscsi, you should execute again the following steps related setting of iscsi because the connection between the NSR-500 Series and iscsi is reset after update installation. If it is not so, proceed to the step-11. 10-1. Open the Setup Menu of the NSR. 10-2. Select Disk menu. 5

NSR Software Update Installation Procedures 10-3. Select iscsi install 10-4. Enter IP Address of the iscsi Disk connected with the NSR and crick Add button. Enter IP address must be the same as that set. 10-5. List of Array will be displayed, when connection has succeeded. 11. User Name and Password are initialized after update installation, when Auto Logon had been enabled and they had been configured. Configure User Name and Password again after update installation. 12. Reboot to finish reconfiguration. 6

NSR ソフトウェアアップデートインストール手順 お客様に行っていただく作業ではありませんので情報の取り扱いにご注意ください 概要 この文書は NSR-500 のアップデートインストール手順について記載します アップデートインストールにより 機能の向上 サポートするカメラ機種の追加 問題の修正などが行われます 内容はソフトウェアバージョンごとに異なりますので アップデートを行う前に 必ずリリースノートをご確認ください また アップデートを行っても 構成情報やカメラの記録データは保持されます 対象モデル NSR-500 シリーズ 準備するもの カーソルが点滅する 以下のどちらかが必要です - インストール USB メモリ ( 注 1) - インストール DVD ( 注 1) および USB インターフェイスを持った DVD ドライブ USB キーボード ( 注 2) ( 注意 ) ( 注 1) Create USB install media (Installer for USB) もしくは Create DVD install media (Installer for DVD) を参照ください Installer for USB Installer for DVD (Software Download) http://www.sony.net/products/ipela/nsr/nsr500/ ( 注 2) 汎用の USB キーボードをお使いください 特殊なキーやボタンは使用できない場合があります 7

手順 NSR ソフトウェアアップデートインストール手順 1. インストール USB メモリもしくはインストール DVD を挿入した DVD ドライブを接続してください DVD ドライブは電源オンの状態にしてください その後 パワーボタンを押して起動してください 2. u キーを押してください ( 注意 ) 上記メッセージが表示されない場合 お使いのインストールデバイスに問題がある可能性がございます インストール USB メモリをお使いの場合には USB メモリを別のものに交換して再実行してください インストール DVD をお使いの場合には DVD ドライブもしくはインストール DVD を別のものに交換して再実行してください 入力確認メッセージが表示される場合があります その場合は y を押してください 8

NSR ソフトウェアアップデートインストール手順 3. BIOS のアップデートと HDD へのソフトウェアのアップデートが開始されます ( 注意 ) 数分間キーボード入力がない場合 スクリーンセーバーが動作し 画面に何も表示されなくなります 画面を再表示させたい場合には Enter キーを押してください 4. インストール USB メモリをお使いの場合 アップデートが完了すると以下のメッセージが表示されます インストール USB メモリを取り外し スペースキーを押してシャットダウンしてください インストール DVD をお使いの場合には アップデートが完了すると自動的にシャットダウンします DVD ドライブを取り外してください 9

NSR ソフトウェアアップデートインストール手順 5. アップデート作業を継続するために電源スイッチを押してください NSR アプリケーションのインストールが完了するまでお待ちください この作業は数分間かかります 6. 5 の作業が完了すると 自動的に再起動します アップデートインストール実施前にセットアップウィザードを実施済みの場合にはログイン画面が表示されます 7 の作業にお進みください セットアップウィザードを実施していない場合には セットアップウィザードが表示されます 手順に従って実行してください ( 詳しくは NSR-500 の設置説明書を御覧ください ) セットアップウィザードが完了すると自動的再起動が実施されます ログイン画面が表示されたら 7 の作業にお進みください ( 注意 ) システムを立ち上げた時に ファイルシステムの状態チェック 復旧処理が実行されます この際 前回に電源が正しく OFF にされなかった 旨のメッセージが表示される場合がありますが 問題はございませんので処理の完了をお待ちくださいますようお願いいたします ( 記録状態によりますが 最長で 15 分程度で完了します ) 7. バージョン情報をご確認ください ( 詳しくは NSR-500 のユーザーガイドをご覧ください ) バージョンが 1.3.0 以上の場合は 12 の作業に進んでください 8. 必ずセットアップメニューの UPS 画面で再設定を行ってください UPS をご使用にならない場合も Disable を選択し OK ボタンを押して再設定を完了ください ( 詳しくは NSR-500 のユーザーガイドを御覧ください ) 9. 必ず Audio 画面で Audio の再設定を行ってください 設定を変更しない場合や AUDIO OUT しか選択できない場合でも Audio 画面を開き OK ボタンを押して再設定を完了させてください ( 詳しくは NSR-500 のユーザーガイドを御覧ください ) 10

NSR ソフトウェアアップデートインストール手順 10. iscsi をご利用の場合は アップデートインストール後 iscsi との接続の設定が初期化されます 以下の手順にしたがって iscsi の再設定を行なってください ご利用でない場合には 11 の作業に進んでください 10-1. Setup Menu を開きます 10-2. Disk を選択します 11

NSR ソフトウェアアップデートインストール手順 10-3. iscsi Install を選択します 10-4. NSR に接続している iscsi Disk の IP Address を入力し 追加 を押します 10-5. 接続が成功すると Array のリストが表示されます 以前の記録設定で記録が再開されます 11. Auto Logon を設定した状態でアップデートを行うと アップデート後に登録されていたユーザー名とパスワードが初期化されます アップデート後にユーザー名とパスワードを再入力してください 12. 設定を完了するため再起動をしてください 12