NAREGI V1 doc

Size: px
Start display at page:

Download "NAREGI V1 doc"

Transcription

1 GD-ADG NAREGI Middleware 使用手引書 ( 管理者編 ) V 年 3 月 国立情報学研究所

2 Copyright 2004 National Institute of Informatics, Japan. All rights reserved. This file or a portion of this file is licensed under the terms of the NAREGI Public License, found at If you redistribute this file, with or without modifications, you must include this notice in the file.

3 J2SSH Library This product includes software developed by SSHTools ( openssl This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit ( This product includes cryptographic software written by Eric Young This product includes software written by Tim Hudson MyProxy This product includes software developed by Computing Services at Carnegie Mellon University ( This product includes software developed by the NetBSD Foundation, Inc. and its contributors. mod-ssl This product includes software developed by Ralf S. Engelschall for use in the mod_ssl project ( NetBSD libnbcompat This product includes software developed by the NetBSD Foundation, Inc. and its contributors. glite/glite Security Utilities This product includes software developed by The EU EGEE Project ( VOMS/VOMS C API This product includes software developed by the EU DataGrid ( aica This product includes software developed by Akira Iwata Laboratory,Nagoya Institute of Technology in Japan ( Xerces Java Parser, XML Security This product includes software developed by the Apache Software Foundation (

4 登録商標または商標について Java は 米国 Sun Microsystems, Inc. の米国およびその他の国における登録商標または商標です Linux は Linus Torvalds 氏の米国およびその他の国における登録商標または商標です AppArmor opensuse は米国 Novell, Inc. の米国およびその他の国における商標です PBS Professional は 米国 Altair Grid Technologies,LLC の商標です AIX LoadLeveler は米国 International Business Machines Corporation の商標です Globus Toolkit は 米国シカゴ大学の商標です その他 記載されている会社名 製品名は各社の登録商標または商標です

5 はじめに 本書は NAREGI Middleware の使用手引書 ( 管理者編 ) です NAREGI Middleware( 以下 NAREGI ミドルウェア ) は 超高速コンピュータ網形成プロジェクト (National Research Grid Initiative: 通称 NAREGI) において開発されたソフトウェアです NAREGI ミドルウェアは 分散した計算資源を管理するだけでなく 利用環境やプログラミング環境をも含めた 統合グリッド環境を提供いたします NAREGI ミドルウェアを構成する多くのコンポーネントは WSRF(Web Services Resource Framework) に準拠した Web サービスとして実装されています NAREGI ミドルウェアは これらコンポーネントを連携動作させ より使い易く より高度なグリッド環境を実現しています NAREGI ミドルウェアについての詳細は をご覧ください 本書の対象読者本書は NAREGI ミドルウェアの導入作業や運用保守を実施される方 利用される方を対象としています ドキュメント体系 NAREGI ミドルウェアのドキュメントは 次の分冊構成を取っています NAREGI Middleware 機能説明書 NAREGI ミドルウェア全体の機能概要について説明しています NAREGI Middleware 導入手引書 NAREGI ミドルウェア全体を通しての動作条件や rpm パッケージを用いたインストール方法について説明しています ( 本書 ) インストール後の NAREGI ミドルウェア全体を通して運用するにあたり 必要な事項について説明しています NAREGI ミドルウェア各サービス個々の運用に関する詳細は 後述の NAREGI ミドルウェア AG および UG を参照ください NAREGI Middleware 使用手引書 ( 利用者編 ) インストール後の NAREGI ミドルウェア各サービスを利用するにあたり 主に GUI を持つサービスについて操作方法を説明しています NAREGI ミドルウェア各サービスの操作詳細については 後述の NAREGI ミドルウェア UG を参照ください 管理者ガイド NAREGI ミドルウェア AG(Administrator Guide) NAREGI ミドルウェア各サービスの管理者向け使用手引書です サービスを構成するコンポーネントごとに分冊構成を取っています 利用者ガイド NAREGI ミドルウェア UG(User Guide) i

6 NAREGI ミドルウェア各サービスの利用者向け使用手引書です サービスを構 成するコンポーネントのうち 利用者向け機能を持つコンポーネントごとに分冊構成を取っています 重要 NAREGI ミドルウェア V1.1 の最新情報 ( サポートする OS バージョンなど ) については Release Notes を参照ください NAREGI ミドルウェアについてご不明な点がございましたら NAREGI ミドルウェア FAQ も合わせて参照ください ii

7 目次 はじめに... i 1. NAREGI ミドルウェアの起動と停止 ノード構成例 起動方法 サービスの一括起動 サービスの個別起動 停止方法 サービスの一括停止 サービスの個別停止 注意事項 起動 停止 VO へのユーザアカウント登録 CA/RA ノードにおける作業 ライセンス ID の登録 UMS ノードにおける作業 ユーザアカウントの作成 設定ファイルの編集 ユーザ証明書の取得 VO 情報付きプロキシ証明書の格納 プロキシ証明書の登録 サインオン Gfarm2 への利用ユーザの登録 grid-mapfile への登録 ユーザ証明書の再作成 VO の新規作成 前提条件 VO の作成 VO の作成 属性証明書の有効期限設定 VOMS の設定と起動 グループの作成 iii

8 3.4 Role の作成 VO 管理者の登録 VO 情報の設定 VO へのユーザ登録 登録したユーザの VO 情報の設定 NAREGI ミドルウェアの複数 VO 設定 Portal の設定 VO 設定ファイル作成 Portal ノードサービス再起動 IS handle 作成 データグリッドの設定 Gfarm メタサーバの設定 Gfarm ファイルシステムノードの設定 データグリッドアクセス管理システムの設定 データグリッド資源管理システムの設定 証明書の更新 ホスト ( サーバ ) 証明書の更新 構成例 新規ホスト証明書の発行 旗艦ノードへのホスト証明書の保存 サービスの停止 証明書の更新 サービスの起動 ユーザ証明書の更新 旧証明書の情報削除 新証明書の発行 プロキシ証明書の更新 Myproxy への Lifetime 登録時間の設定 ジョブ投入時の Lifetime の設定 資源追加と削除 計算資源の組込み 切り離し時の資源情報の更新 ノード構成 組込み時の資源情報の更新 切り離し時の資源情報の更新 iv

9 6.2 計算資源 (GridVM 計算ノード ) の組込みと切り離し ノード構成例 計算資源の組込み 計算資源の切り離し GridVM 計算ノードがプライベートアドレス時の設定 GridRPC を動作させる場合の注意事項 SBC を動作させる場合の設定 GridVM 管理ノード上の中継プロセスの設定 各計算ノード上のハンドルの修正 メンテナンス 証明書の更新 PSE におけるプロキシ証明書の更新 ユーザ証明書の更新 バックアップとリストア PSE(ACS) データのバックアップとリストア ワークフロー等ユーザ情報のバックアップとリストア Gfarm ファイルシステム上のバックアップとリストア PSE(ACS) における定期更新 GUI サーバ上のテンポラリファイルの削除 ApplicationPool サーバ上のテンポラリファイルの削除 CompileService, DeployService サーバ上のテンポラリファイルの削除 データベースの物理削除 セルドメインデータベースのメンテナンス セルドメインデータベースの比較 セルドメインデータベースの複製 セルドメインデータベースのマージ セルドメインデータベースにおけるデータの削除 資源利用記録および SBC 関連情報におけるデータの削除 GridMPI の実行環境設定 rsh, ssh の環境設定 impi-server の実行資源の設定方法 チューニング アクティビティ数によるジョブ受付け制限のための設定 プログラムの実行時間とファイル転送時間 Java VM の設定 v

10 8.6.4 SBC を用いた連成ジョブの一時ファイルの削除 Globus Toolkit の利用ポートの変更 リカバリ NAREGI-IS データベースの再構築時の処理 IS ハンドル作成時の不要スキーマの削除方法 カスタマイズ 画面構成のカスタマイズ 情報提供形式のカスタマイズ データ管理 ワークフロートラッキング機能のための設定 ログディレクトリの設定 LRPS の EPR ファイルの生成 LRPS の grid-mapfile 設定 JLOGD のログローテーションについて サービス状態情報通知機能のための設定 LRPS の EPR ファイルの生成 LRPS の grid-mapfile の生成 SS-Statd のログローテーションについて 利用量制御機能の設定 GridVM スケジューラ設定ファイルの設定 利用量制御ポリシー設定ファイルの設定 アクセス保護機能の設定 資源情報 VO 対応版 Gfarm 操作手順 IS 利用のための設定 ログ インストール時のログ ログファイル Portal ノード IS ノード SS ノード GridVM 管理ノード データグリッド (DG) ノード Syslog 形式 vi

11 設定方法 SS のログローテーションについて 設定方法 SS Server の再起動 動作確認方法 留意事項 トラブルシューティング ユーザ証明書取得時のエラーメッセージ プロキシ証明書取得時の不具合 UMS への VO 登録時の不具合 UMS ノードにおける作業 SS ノードにおける作業 Portal ノードにおける作業 PSE 使用時の不具合 コンパイル実行時の不具合 デプロイ時の不具合 アプリケーション実行時の不具合 WFT 使用時の不具合 ユーザ GUI に表示されるメッセージ ( その 1) ユーザ GUI に表示されるメッセージ ( その 2) GridMPI ジョブ実行時の不具合 ( その 1) GridMPI ジョブ実行時の不具合 ( その 2) GridMPI ジョブ実行時の不具合 ( その 3) ノードが表示されない不具合 ( その 1) ノードが表示されない不具合 ( その 2) ジョブ実行時の不具合 ( その 1) ジョブ実行時の不具合 ( その 2) ジョブ実行時の不具合 ( その 3) ジョブ実行時の不具合 ( その 4) ジョブ実行時の不具合 ( その 5) ジョブ実行時の不具合 ( その 6) GridMPI 使用時の不具合 プライベートアドレス環境における不具合 SS ノードにおける不具合 ディスク容量に関する不具合 ( その 1) vii

12 ディスク容量に関する不具合 ( その 2) GridVM Scheduler における不具合 起動時のエラーメッセージ ( その 1) 起動時のエラーメッセージ ( その 2) 停止時のエラーメッセージ 制限事項 ワーキングディレクトリおける制限事項 viii

13 1. NAREGI ミドルウェアの起動と停止 本章では rpm パッケージを用いてインストールした NAREGI ミドルウェアの起動方 法と停止方法について説明します 1.1 ノード構成例本章で説明するノード構成の例は次表の通りです 表 ノード構成例 種別旗艦ノード ( 兼 CA/RA ノード ) UMS ノード Portal ノード SS ノード IS-NAS ノード IS-CDAS ノード GridVM 管理ノード GridVM 計算ノード DG-Gfarm-VO ノード DG-DGUFT ノード Gfarm2 メタデータサーバノード兼 Gfarm2 GridFTP サーバノード Gfarm2 ファイルシステムノード (*) GridVM 計算ノードも兼ねる 名称 naregi-cara naregi-ums naregi-portal naregi-ss naregi-isnas naregi-iscdas naregi-gvms1(*) naregi-gvms1, naregi-gvmc1 naregi-gfarm naregi-dguft naregi-gfarm2-md naregi-gfarm2-fs1, naregi-gfarm2-fs2 1.2 起動方法 サービスの一括起動 NAREGI ミドルウェアを構成する各サービスの一括起動の手順を説明します 旗艦ノ ードにおいて 次のコマンドを実行します [installuser@naregi-cara ~]$ /usr/naregi/sbin/nrg-install.sh NAREGI インストーラの起動 ####################################################################### ################# NAREGI TOOL ############################ ####################################################################### ### Select Operation ### ### [1] OS update (this node) ### 1

14 ### [2] setup NAREGI nodes information ### ### [3] OS update (remote nodes) ### ### [4] certificate ### ### [5] install globus (all nodes except UMS,onlyCA,onlyRA) ### ### [-] build UMS ### ### [7] install NAREGI middle rpm-pkg (each node) ### ### [8] start/stop/restart naregi-service ### ### [9] IS handle ### ### [0] exit ### ####################################################################### Select Operation (0-9): 8 start/stop/restart naregi-service ( 本例では8) を選択 Your input : 8 OK? [Y/n]: 空送信 ( リターンキー ) で次へ *********************************************************************** [8] start naregi-service *********************************************************************** start NAREGI service (1) start (2) stop (3) restart (4) status (0) exit Select NAREGI service (0-4): 1 start ( 本例では1) を選択 Your input : 1 OK? [Y/n]: 空送信 ( リターンキー ) で次へ *********************************************************************** [8]-(1) start naregi service *********************************************************************** *********************************************************************** 1. GridVM *********************************************************************** * GridVM Scheduler HOSTs : * naregi-gvms1.naregi.org *********************************************************************** * GridVM Engine HOSTs : * naregi-gvms1.naregi.org * naregi-gvmc1.naregi.org *********************************************************************** Start [gmond] at HOST:[naregi-gvms1.naregi.org]... Starting GANGLIA gmond: [ OK ] Start [Local-Scheduler] at HOST:[naregi-gvms1.naregi.org]... 2

15 Connection to naregi-gvms1.naregi.org closed. Starting PBS PBS mom PBS sched Using license server at PBS server Start [naregi-gridvm-scheduler] at HOST:[naregi-gvms1.naregi.org]... Starting NAREGI GridVM scheduler Daemon: [ OK ] Start [naregi-is-lrps] at HOST:[naregi-gvms1.naregi.org]... Starting NAREGI IS LRPS: [ OK ] Start [globus] at HOST:[naregi-gvms1.naregi.org]... Starting Globus: ( 中略 ) *********************************************************************** [8]-(1) start naregi service complete *********************************************************************** なお UMS ノード上のコンポーネントは NAREGI ミドルウェアの rpm パッケージに含 まれないため サービスを個別に起動する必要があります 手順は 1.2.2(7) UMS ノー ド を参照ください サービスの個別起動 NAREGI ミドルウェア各サービスについて 個別起動の手順を説明します UMS ノード上のサービス以外は NAREGI ミドルウェア rpm パッケージ付属のスクリプトを用いた手順で説明し UMS ノードは glite 付属のスクリプトを用いた手順で説明します 個別起動は 各サービスを稼働させるノードにおいてインストールユーザのアカウントもしくはユーザ root で実施します 以下の例では インストールユーザを installuser としています (1) GridVM 管理ノード (1-1) Ganglia GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/gmond-nrg start コンフィグレーションファイルの設定については 管理者ガイド NAREGI ミドルウェア IS(Distributed Information Service) コンフィグレーションファイルの設定と起動 を参照してください 3

16 (1-2) GridVM Scheduler GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-gridvm-scheduler start なお GridVM Scheduler の起動よりも前にローカルスケジューラが起動されている必要があるので留意ください GridVM Scheduler の起動より前にローカルスケジューラが起動されていない場合 次のエラーメッセージが出力されることがあります Starting GridVM Scheduler Daemon: initialize failed ローカルスケジューラが PBS Professional の場合 対応手順は 起動時のエラーメッセージ ( その 2) をご参照ください また GridVM Scheduler を再起動する場合 何らかの原因で前回の daemon が残ってお り GridVM Scheduler が既に起動済みである旨のエラーメッセージが出力されることが あります Starting GridVM Scheduler Daemon: Already running or check /usr/naregi/gridvm/scheduler/var/id/gvmsd.pid この場合はユーザ root でプロセス ID ファイルを削除後 GridVM Scheduler を起動して ください 対応手順は 起動時のエラーメッセージ ( その 1) をご参照ください (1-3) LRPS GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/naregi-is-lrps start (1-4) Globus コンテナ GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/globus start (1-5) GridVM Engine(GridVM SchedulerとGridVM Engineが同一ノード上の場合 ) GridVM Scheduler と Grid Engine が導入されている同一ノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/naregi-gridvm-engine start 4

17 (2) GridVM 計算ノード (2-1) Ganglia GridVM Engine が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/gmond start (2-2) GridVM Engine GridVM Engine が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-gridvm-engine start (3) IS-CDAS ノード CDAS が導入されているノードにおいて 以下のコマンドを実行します ~]$ sudo /etc/init.d/naregi-is start なお 再起動 ( 停止 起動 ) を繰り返した場合 上記コマンド内で起動している tomcat プロセスが残存する場合があります 再起動は残存 tomcat プロセスの有無を ps コマン ド等で確認し kill コマンド等で終了してから実施ください (4) IS-NAS ノード NAS が導入されているノードにおいて 以下のコマンドを実行します [installuser@naregi-isnas ~]$ sudo /etc/init.d/naregi-is start [installuser@naregi-isnas ]$ sudo /etc/init.d/postgresql start なお IS-NAS に接続する SS ノードを変更した場合など PostgreSQL の SSL クライアン ト設定の更新が必要な場合は 上記手順の前に PostgreSQL の再起動が必要になります [installuser@naregi-isnas ~]$ sudo /etc/init.d/postgresql stop [installuser@naregi-isnas ~]$ sudo /etc/init.d/postgresql start 5

18 (5) SSノード (5-1) SS SS が導入されているノードにおいて 次の各コマンドを実行します ~]$ sudo /etc/init.d/naregi-ss start なお SS は SS の生成するログファイルをローテーションするための設定を行う必要があります 詳細は 10.4 SS のログローテーションについて をご参照ください (5-2) RenewalService SS が導入されているノードにおいて 次の各コマンドを実行します ~]$ sudo /etc/init.d/naregi-rs start (6) Portalノード (6-1) globus Portal が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/globus start (6-2) myproxy Portal が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/myproxy start (6-3) portal Portal が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-portal start (7) UMSノード UMS ノード上の VOMS(gLite VOMS) は NAREGI ミドルウェアのパッケージに含まれないため 次の手順で起動します ~]# /etc/init.d/glite start 6

19 (8) DG-Gfarm-VO ノード (8-1) Gfarm メタデータサーバ ~]$ sudo /etc/init.d/gfarm-pgsql start ~]$ sudo /etc/init.d/gfmd start (8-2) Globus コンテナ ~]$ sudo /etc/init.d/globus start (8-3) Gfarm ファイルシステム ~]$ sudo /etc/init.d/gfsd start (9) DG-DGUFT ノード (9-1) Globus コンテナ ~]$ sudo /etc/init.d/globus start (9-2) Gfarm ファイルシステムノード ~]$ sudo /etc/init.d/gfsd start (10) Gfarm2 メタデータサーバノード ~]$ sudo /etc/init.d/gfarm-pgsql start ~]$ sudo /etc/init.d/gfmd start (11) Gfarm2 ファイルシステムノード ~]$ sudo /etc/init.d/gfsd start 7

20 1.3 停止方法 サービスの一括停止 NAREGI ミドルウェアを構成する各サービスの一括停止の手順を説明します 旗艦ノ ードにおいて 次のコマンドを実行します ~]$ /usr/naregi/sbin/nrg-install.sh NAREGIインストーラの起動 ####################################################################### ################# NAREGI TOOL ############################ ####################################################################### ### Select Operation ### ### [1] OS update (this node) ### ### [2] setup NAREGI nodes information ### ### [3] OS update (remote nodes) ### ### [4] certificate ### ### [5] install globus (all nodes except UMS,onlyCA,onlyRA) ### ### [-] build UMS ### ### [7] install NAREGI middle rpm-pkg (each node) ### ### [8] start/stop/restart naregi-service ### ### [9] IS handle ### ### [0] exit ### ####################################################################### Select Operation (0-9): 8 start/stop/restart naregi-service ( 本例では8) を選択 Your input : 8 OK? [Y/n]: 空送信 ( リターンキー ) で次へ *********************************************************************** [8] start naregi-service *********************************************************************** start NAREGI service (1) start (2) stop (3) restart (4) status (0) exit Select NAREGI service (0-4): 2 stop ( 本例では2) を選択 Your input : 2 OK? [Y/n]: 空送信 ( リターンキー ) で次へ *********************************************************************** [8]-(2) stop naregi service 8

21 *********************************************************************** *********************************************************************** 1. Portal *********************************************************************** Stop [naregi-portal] at HOST:[naregi-portal.naregi.org]... Using JAVA_ENDORSED_DIRS: /usr/naregi/tomcat5/common/endorsed Using GLOBUS_LOCATION: /usr/naregi/gt4 Using CATALINA_BASE: /usr/naregi/tomcat5 Using CATALINA_HOME: /usr/naregi/tomcat5 Using CATALINA_TMPDIR: /usr/naregi/tomcat5/temp Using JAVA_HOME: /usr/lib/jdk Stopping NAREGI Portal: [ OK ] Stop [myproxy] at HOST:[naregi-portal.naregi.org]... Stopping the MyProxy server... done. Connection to naregi-portal.naregi.org closed. ( 中略 ) *********************************************************************** [8]-(2) stop naregi service complete *********************************************************************** なお UMS ノード上のコンポーネントは NAREGI ミドルウェアの rpm パッケージに含 まれないため サービスを個別に停止する必要があります 手順は 1.3.2(7) UMS ノー ド を参照ください サービスの個別停止 NAREGI ミドルウェア各サービスについて 個別停止の手順を説明します UMS ノード上のサービス以外は NAREGI ミドルウェア rpm パッケージ付属のスクリプトを用いた手順を説明し UMS ノードは glite 付属のスクリプトを用いた手順で説明します 個別停止は 各サービスを稼働させるノードにおいてインストールユーザのアカウントもしくはユーザ root で実施します 以下の例では インストールユーザを installuser としています (1) Portalノード (1-1) portal Portal が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-portal ~]$ sudo /etc/init.d/naregi-portal stop (1-2) myproxy Portal が導入されているノードにおいて 次のコマンドを実行します 9

22 ~]$ sudo /etc/init.d/myproxy stop (1-3) globus Portal が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/globus stop (2) SSノード (2-1) RenewalService SS が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-rs stop (2-2) SS SS が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-ss stop (3) IS-NAS ノード NAS が導入されているノードにおいて 以下のコマンドを実行します ~]$ sudo /etc/init.d/naregi-is stop (4) IS-CDAS ノード CDAS が導入されているノードにおいて 以下のコマンドを実行します ~]$ sudo /etc/init.d/naregi-is stop (5) GridVM 計算ノード (5-1) GridVM Engine GridVM Engine が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/naregi-gridvm-engine stop 10

23 (5-2) Ganglia GridVM Engine が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/gmond stop (6) GridVM 管理ノード (6-1) GridVM Engine(GridVM SchedulerとGridVM Engineが同一ノード上の場合 ) GridVM Scheduler と GridVM Engine が導入されている同一ノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/naregi-gridvm-engine stop (6-2) LRPS GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/naregi-is-lrps stop (6-3) GridVM Scheduler GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/naregi-gridvm-scheduler stop なお何らかの理由で GridVM Scheduler の親プロセスが既に停止している場合 次のエラーメッセージが出力されることがあります Shutting down GridVM Scheduler Daemon: PID = xxxxx /usr/naregi/gridvm/scheduler/sbin/gvmsd.sh: kill: no such process この場合は GridVM Scheduler の残存プロセスを停止し プロセス ID ファイルを削除します その後 GridVM Scheduler を一旦起動してから正常に停止させます 対応手順は 停止時のエラーメッセージ を参照してください (6-4) Globus コンテナ GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します [installuser@naregi-gvms1 ~]$ sudo /etc/init.d/globus stop 11

24 (6-5) Ganglia GridVM Scheduler が導入されているノードにおいて 次のコマンドを実行します ~]$ sudo /etc/init.d/gmond-nrg stop (7) UMSノード UMS ノード上の VOMS(gLite VOMS) は NAREGI ミドルウェアのパッケージに含まれないため 次の手順で停止します ~]# /etc/init.d/glite stop (8) DG-Gfarm-VO ノード (8-1) Gfarm ファイルシステムノード ~]$ sudo /etc/init.d/gfsd stop (8-2) Globus コンテナ ~]$ sudo /etc/init.d/globus stop (8-3) Gfarm メタデータサーバ ~]$ sudo /etc/init.d/gfmd stop ~]$ sudo /etc/init.d/gfarm-pgsql stop (9) DG-DGUFT ノード (9-1) Gfarm ファイルシステムノード ~]$ sudo /etc/init.d/gfsd stop (9-2) Globus コンテナ ~]$ sudo /etc/init.d/globus stop 12

25 (10) Gfarm2 メタデータサーバノード (10-1) Gfarm2 メタデータサーバ ~]$ sudo /etc/init.d/gfarm-pgsql stop ~]$ sudo /etc/init.d/gfmd stop (11) Gfarm2 ファイルシステムノード ~]$ sudo /etc/init.d/gfsd stop 1.4 注意事項 GridVM クラスタ (GridVM 管理ノードおよび GridVM 計算ノード ) 上のローカルスケジューラを再起動した場合 GridVM クラスタ上の NAREGI ミドルウェア各サービスも再起動 ( 停止 起動 ) する必要があります 起動 1.2.2(1) GridVM 管理ノード から 1.2.2(2) GridVM 計算ノード の作業を順番に行います 停止 1.3.2(5) GridVM 計算ノード から 1.3.2(6) GridVM 管理ノード の作業を順番に行い停止します 13

26 2. VO へのユーザアカウント登録 本章では rpm パッケージを用いてインストールされた NAREGI ミドルウェアの VO へユーザを登録する際の手順について説明します ここで VO は既に作成されているものとします VO の新規作成手順は 3 VO の新規作成 を参照ください なお CA 局を別途運営している場合は CA UMS および VOMS の管理者向け操作手引書を参照ください NAREGI ミドルウェアはローカルスケジューラを用いて job 管理を行うことから 登録するユーザは 同一 GridVM クラスタ内でのホームディレクトリの共有および grid-mapfile へのアカウント登録が必要です この場合 ユーザ名として job を実行する ( ホームディレクトリが共有されている ) アカウントを登録します grid-mapfile へのアカウント登録は 2.4 grid-mapfile への登録 をご参照ください 2.1 CA/RA ノードにおける作業 ライセンス ID の登録 CA/RA ノードにおいてユーザ root で実施します 次の例で ディレクトリ "globususer" は CA/RA ノードの CA 設定ファイル (aica.conf) で raname として設定されている値です [root@naregi-cara root]# cd /usr/naregi/ra/globususer [root@naregi-cara globususer]# vi en.license ============================== # # ** enroll user registration file (One time LicenseID) ** # ( 略 ) XXX-XXXX-XXX-XXXX ライセンス ID を追記する ライセンス ID として登録できる文字数は 30 文字までです ユニークでランダムなライセンス ID を発行したい場合 データ作成支援ツールを用 いて発行してください データ作成支援ツールについては コンポーネントごとのドキュメント 管理者ガイド NAREGI Middleware CA の 5.6 Web Enroll 補助ツール を参照ください 以下の例では ライセンスヘッダとして NAREGI 初期ベクトルとして 1234 を指定しています [root@naregi-cara globususer]# /usr/naregi/ra/bin/aienrtool -lic -hd NAREGI -iv 1234 >> en.license 14

27 2.2 UMSノードにおける作業続いて UMS ノードにおいてユーザアカウント登録を行います 次の例では VO 名 を rpmtest としています ユーザアカウントの作成 UMS ノードにおいてユーザ root で実施します 次の例では 追加するユーザアカウ ントを naregiuser ユーザアカウントのホームディレクトリを /home/naregiuser としてい ます root]# useradd naregiuser root]# passwd naregiuser Changing password for user naregiuser. New password: Retype new password: passwd: all authentication tokens updated successfully. アカウント作成およびパスワード設定 root]# vipw naregiuser:x:10079:10079::/home/naregiuser: /bin/bash naregiuser:x:10079:10079::/home/naregiuser: /usr/naregi/ums/pass.sh ログインシェル ( 下線部 ) を /usr/naregi/ums/pass.sh に変更 設定ファイルの編集 UMS ノードにおいてユーザ root で実施します vomses ファイルおよび fqan ファイル の syntax は 3.8 登録したユーザの VO 情報の設定 も参照ください [root@naregi-ums root]# cd /home/naregiuser [root@naregi-ums naregiuser]# mkdir.glite.gliteディレクトリを作成 [root@naregi-ums naregiuser]# cd.glite [root@naregi-ums.glite]# vi vomses "rpmtest", "naregi-ums.naregi.org", "15000", "/C=JP/O=naregi/OU=togo/CN=host/nareg i-ums.naregi.org", "rpmtest" vomsesファイルを作成し VO 情報 ("VO 名 "," ホスト名 "," ポート番号 "," ホストcert-subject","VO 名 ") を追記する [root@naregi-ums.glite]# vi fqan /VO=rpmtest/Group=grp1/Role=DefaultRole VO 情報の設定として fqan ファイルを作成 15

28 chown -R naregiuser:naregiuser /home/naregiuser/.glite.glite ディレクトリ配下のファイルとディレクトリの owner と group を変更 ユーザ証明書の取得 NAREGI ミドルウェア Portal 画面の左側メニューにおいて UserManagementServer (UMS) の Login をクリックすると 右側ペインが Login 画面に遷移します ( 図 2.2-1) この Login 画面において ユーザアカウントの作成 で作成したユーザ名 ( ここでは naregiuser) とパスフレーズを入力し Login ボタンをクリックして UMS に接続します 図 Portal 画面 次に 画面左側メニューの Certificate Issue / Renewal をクリックすると Certificate Issue / Renewal 画面 ( 図 2.2-2) へ遷移します この画面からユーザ証明書を取得します 各入力フォームへの入力値は表 を参照ください 16

29 図 Certificate Issue / Renewal 画面 表 画面入力値 入力フォームのラベル 入力値 入力値の例 License ID ライセンス ID(2.1.1 で設 naregi 定した値 ) Your Full Name ユーザ名 naregiuser Private Key Passphrase ユーザ証明書のパスフ ( 任意 ) レーズ Private Key Passphrase(Retype) 同上 同上 全ての値を入力後 Enroll ボタンを押してユーザ証明書を取得します VO 情報付きプロキシ証明書の格納 UMS ノードにおいてユーザ root で実施します [root@naregi-ums.glite]# cd /home/naregiuser/.globus [root@naregi-ums.globus]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-us er ~naregiuser/.globus/usercert.pem add-member grp1 ~naregiuser/.globus/usercert.pem assign-role grp1 DefaultRole --usercert ~naregiuser/.globus/usercert.pem [root@naregi-ums.globus]# /opt/glite/bin/voms-admin --vo rpmtest list-users CN certuri mail DN CA voms /C=JP/O=naregi/OU=togo/CN=voms /C=JP/O=naregi/OU=togo naregiuser /C=JP/O=naregi/OU=togo/CN=Naregi Tarou /C=JP/O=naregi/OU=togo 設定した VO にユーザが登録されているか確認 17

30 2.2.5 プロキシ証明書の登録 NAREGI ミドルウェアの Portal 画面の左側メニュー Proxy Certificate Registration をクリックすると Proxy Certificate Registration 画面 ( 図 2.2-3) へ遷移します この画面からプロキシ証明書を取得します 各入力フォームへの入力値は表 を参照してください 図 Proxy Certificate Registration 画面 表 画面入力値 入力フォームのラベル 入力値 入力 / 選択値の例 Private Key Passphrase ユーザ証明書のパスフレーズ (2.2.3 で設定した値 ) New Proxy Certificate Passphrase プロキシ証明書のパス ( 任意 ) フレーズ VO ユーザの所属 VO rpmtest Group ユーザの所属グループ Grp3 Role 所属グループ内のユーザの Role DefaultRole 全ての値を入力 / 選択後 Register ボタンを押してプロキシ証明書を登録します サインオン NAREGI ミドルウェアの Portal 画面の左側メニュー Sign On をクリックすると Sign On 画面 ( 図 2.2-4) へ遷移します この画面から Sign On します 各入力フォームへの入力値は表 を参照ください 18

31 図 Sign On 画面 表 画面入力値 入力フォームのラベル 入力値 入力 / 選択値の例 User Name で登録したユーザ名 naregiuser Registered Proxy Certificate Passphrase で登録したプロキシ証明書のパスフレーズ サインオンが出来ることを確認後 grid-mapfile の編集を行います 2.3 Gfarm2 への利用ユーザの登録 Gfarm2 が導入されている場合には Gfarm2 へのユーザ登録を行います Gfarm2 管理ユーザ ( 本例では gf2admin) で Gfarm2 メタデータサーバにて 次のコマンドを実行します [gf2admin@naregi-gfarm2-md ~]$ grid-proxy-init Your identity: /C=JP/O=naregi/OU=togo/CN=gf2admin Enter GRID pass phrase for this identity: Creating proxy... Done Your proxy is valid until: Thu Mar 11 06:44: 管理ユーザのパスフレーズを入力 [gf2admin@naregi-gfarm2-md ~]$ /usr/naregi/sbin/gfuseradd D "/C=JP/O=naregi/OU=tog o/cn=naregi Tarou" naregiuser gfuseradd を実行 *********************************************************************** Synchronism VOs *********************************************************************** 19

32 * VO HOSTs: * naregi-ums.naregi.org *********************************************************************** synchronism VOs? [Y/n]: 空送信 ( リターンキー ) で次へ *********************************************************************** get vomsid from HOST:naregi-ums.naregi.org... vomsid:1a7dd7235b92f04f345c7a3e720f42d8e3dbfc74... *********************************************************************** ( 中略 ) *********************************************************************** Synchronism VOs complete *********************************************************************** [gf2admin@naregi-gfarm2-md ~]$ grid-proxy-destroy 2.4 grid-mapfileへの登録ユーザアカウント登録の後 GridVM 管理ノード GridVM 計算ノード DG-Gfarm-VO ノード DG-DGUFT ノード Gfarm2 GridFTP サーバノードおよび Gfarm2 ファイルシステムノードに grid-mapfile を登録します 次の例では ユーザ名を naregiuser ユーザ証明書 DN を /C=JP/O=naregi/OU=togo/CN=Naregi Tarou としています # grid-mapfile-add-entry -dn "/C=JP/O=naregi/OU=togo/CN=Naregi Tarou" -ln "naregi user" gridmap-file への登録 Modifying /etc/grid-security/grid-mapfile... /etc/grid-security/grid-mapfile does not exist... Attempting to create /etc/grid-security/grid-m apfile New entry: "/C=JP/O=naregi/OU=togo/CN=Naregi Tarou" naregiuser (1) entry added # cat /etc/grid-security/grid-mapfile "/C=JP/O=naregi/OU=togo/CN=Naregi Tarou" naregiuser 登録内容の確認 2.5 ユーザ証明書の再作成ユーザ証明書を再作成する場合 あらかじめ VO 情報の削除および登録済の Portal ノードのプロキシ証明書の削除を行う必要があります VO 情報の削除は UMS ノードにおいて ユーザ root で行います 次の例では VO 名を rpmtest ユーザ証明書を再作成するユーザを naregiuser としています 20

33 ~]# cd ~naregiuser/.globus ~]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest delete-user use rcert.pem UMS ノードにおいて登録済みの VO 情報を削除 ~]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest list-users 削除ユーザがリストされないことを確認 次に 登録済のプロキシ証明書の削除を Portal ノードにおいてユーザ root で行いま す 次の例では NAREGI ミドルウェアのインストールディレクトリを /usr/naregi ユー ザ証明書を再作成するユーザを naregiuser としています ~]# cd /usr/naregi/gt4/var/myproxy ~]# rm naregiuser.creds naregiuser.data Portal ノードにおいて登録済みのプロキシ証明書を削除 21

34 3. VOの新規作成 3.1 前提条件 ここでは 以下の条件で新規に VO を作成するものとします 表 VO 設定条件 設定項目 設定値 新規作成 VO 名 rpmtest VO 管理者名 voms 新規作成 VO へ登録するユーザ naregiuser グループ名 grp1 Role 名 DefaultRole port 番号 UMS ノード名 naregi-ums.naregi.org NAREGI ミドルウェアは 予め VO 内に作成したグループにユーザを所属させることが出来ます これによりユーザは 同じグループのメンバと登録したアプリケーションやプログラムを共有することができます グループの詳細については 利用者ガイド NAREGI ミドルウェア PSE を参照ください 以下で説明する操作は UMS ノードにおいて root ユーザで実施します また $GLITE_LOCATION は glitevoms のインストールディレクトリです 3.2 VOの作成 VOの作成コマンドラインから VO を作成します root]# $GLITE_LOCATION/sbin/voms-admin-configure install --vo rp mtest --port dbapwd mysql --smtp-host localhost --mail-from VO の作成 ( 略 ) Installation complete. Note that you must start up your new VO yourself: /opt/glite/etc/init.d/voms start rpmtest /opt/glite/etc/init.d/voms-admin start rpmtest --port は新規登録する VO に対応する port 番号を指定します なお VO ごとに異なる port 番号を指定する必要があります --dbapwd は UMS 導入時に mysql に設定したパスワードを指定します ( 導入手引書 MySQL 設定 を参照ください ) 22

35 --smtp-host は NAREGI サービスが生成したメールを送信するホスト名 ( 既定は localhost) --mail-from は NAREGI サービスが生成したメールを送信するアドレス ( 既定は root@localhost) を指定します 属性証明書の有効期限設定属性証明書の有効期限 ( 既定では 秒 ) を必要に応じて変更します $GLITE_LOCATION/etc/voms/vo 名 /voms.conf に以下を追記します --timeout= 時間 ( 秒 ) なお この値はプロキシ証明書の有効期限 ( 規定では 168 時間 = 秒 ) と合わせておくことを推奨します VOMS の設定と起動 UMS ノード上の VOMS(gLite VOMS) を起動します [root@naregi-ums root]# $GLITE_LOCATION/etc/config/scripts/glite-voms-server-config.p y --configure 設定情報を VOMS に登録 ( 略 ) The glite VOMS Server configuration was successfully completed You can start now the VOMS server via the option start [root@naregi-ums root]# [root@naregi-ums root]# $GLITE_LOCATION/etc/config/scripts/glite-voms-server-config.p y --start 作成したVOのVOMSサーバの起動 Check.bash_profile content Check.bashrc content Check.cshrc content Check.tcshrc content Starting MySQL [OK] Starting MySQL daemon [OK] Stopping tomcat5: Starting tomcat5: [OK] Starting Tomcat [OK] Starting edg-voms(rpmtest) [OK] The rpmtest VO is enabled in the following contexts: /var/lib/tomcat5/conf/catalina/localhost/voms-admin-rpmtest.xml The siblings webapp is enabled in the following contexts: /var/lib/tomcat5/conf/catalina/localhost/voms-siblings.xml (Tomcat will automatically recognize the changes in a moment.) Staring the glite R-GMA Servicetool service Check.bash_profile content Check.bashrc content Check.cshrc content Check.tcshrc content 23

36 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Starting the glite R-GMA Service Publisher xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Starting rgma-servicetool: [OK] Starting glite R-GMA Service Publisher [OK] glite R-GMA Service Publisher successfully started The glite R-GMA Servicetool service has been started [OK] The glite VOMS Server was successfully started root]# root]# $GLITE_LOCATION/etc/config/scripts/glite-voms-server-config.p y --status ステータスの確認 Owner of file or directory /var/glite is root:root Owner of file or directory /var/glite is root:root ( 略 ) xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Checking status of glite VOMS Server xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Status of VOs VOMS-admin server: Testing rpmtest: [ OK ] Status of VOs VOMS server: Testing rpmtest: [ OK ] Check.bash_profile content Check.bashrc content Check.cshrc content Check.tcshrc content xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Checking status of glite R-GMA Service Publisher xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx The glite R-GMA Service Publisher is running. 3.3 グループの作成 VO にグループを登録します なおグループを作成する前に VOMS が起動している必要があります [root@naregi-ums root]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-group grp1 24

37 root]# グループの配下にサブグループ ( 本例では subgrp1) を作成する場合は 半角スラッシ ュで区切って指定します [root@naregi-ums root]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-group grp1/subgrp1 [root@naregi-ums root]# 3.4 Roleの作成 VO に Role を作成します なお Role を作成する前に VOMS が起動している必要があります [root@naregi-ums root]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-role D efaultrole [root@naregi-ums root]# 3.5 VO 管理者の登録 VO に管理者を登録します なお VO 管理者を登録する前に VOMS が起動している必要があります 次の例では ユーザ voms の VO へのユーザ登録 (create-user) と VO 管理者としての登録 (assign-role VO VO-Admin) とを同時に行っています また ~voms/.globus/usercert.pem は VO 管理者のユーザ証明書への path を指定します [root@naregi-ums root]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-user ~ voms/.globus/usercert.pem assign-role VO VO-Admin ~voms/.globus/usercert.pem [root@naregi-ums root]# 3.6 VO 情報の設定作成した VO の情報を vomses ファイルに記述します vomses ファイルの syntax は次の通りです "VO nickname", "hostname", "Port_number", "Host_Cert_Subject", "your-vo" UMS ノードのホスト証明書の DN は NAREGI ミドルウェアインストール実施前の事前設定情報を参照ください また設定にあたり 既存 VO との port 番号の重複に注意ください 25

38 root]# vi $GLITE_LOCATION/etc/vomses vomses ファイルの編集 "rpmtest","naregi-ums.naregi.org","15000","/c=jp/o=naregi/ou=togo/cn=host/naregi-ums. naregi.org","rpmtest" root]# 3.7 VOへのユーザ登録作成した VO と Role グループへユーザ( 本例では naregiuer) を登録します ~naregiuser/.globus/usercert.pem は 登録するユーザ ( naregiuser) のユーザ証明書への path を指定します [root@naregi-ums root]# $GLITE_LOCATION/bin/voms-admin --vo rpmtest create-user ~ naregiuser/.globus/usercert.pem add-member grp1 ~naregiuser/.globus/usercert.pem assignrole grp1 DefaultRole --usercert ~naregiuser/.globus/usercert.pem [root@naregi-ums root]# 3.8 登録したユーザのVO 情報の設定 VO に登録したユーザのホームディレクトリ /.glite ディレクトリ ( 無い場合は作成 ) に移動し vomses ファイルと fqan ファイルを作成します. vomses ファイルの syntax は次の通りです ( 3.6 VO 情報の設定 と同様 ) "VO nickname", "hostname", "Port_number", "Host_Cert_Subject", "your-vo" fqan ファイルの syntax は次の通りです /VO=<VO 名 >/Group=<Group 名 >/Role=<Role 名 > 改行 行の最後に改行が必要 UMS ノードのホスト証明書の DN は NAREGI ミドルウェアインストール実施前の事前設定情報を参照ください また設定にあたり 既存 VO との port 番号の重複に注意ください [root@naregi-ums root]# vi ~naregiuser/.glite/vomses "rpmtest","naregi-ums.naregi.org","15000","/c=jp/o=naregi/ou=togo/cn=host/naregi-ums. naregi.org","rpmtest" vomses ファイルの編集 [root@naregi-ums root]# vi ~naregiuser/.glite/fqan /VO=rpmtest/Group=grp1/Role=DefaultRole fqan ファイルの編集 [root@naregi-ums root]# chown -R naregiuser:naregiuser ~naregiuesr/.glite 26

39 4. NAREGI ミドルウェアの複数 VO 設定 4.1 Portal の設定 Portal ノードにおいて以下の操作を行います VO 設定ファイル作成 Portal が参照する VO 設定ファイルを作成します 既存の VO 設定ファイルを利用し て 新規の VO 名でコピーしてください コピー後に ユーザ及びグループ名を portal に変更します ここでは既に存在する VO 名を rpmtest 新規作成 VO を rpmtest2 としま す # cd /var/lib/tomcat5/webapps/portal/web-inf/conf # cp VO=rpmtest1.xml VO=rpmtest2.xml # chown portal:portal VO=rpmtest2.xml Portal ノードサービス再起動 VO 設定ファイルを作成後 Portal ノード上のサービスを再起動してください 再起動 の手順は 1.2.2(6) Portal を参照ください 4.2 IS handle 作成 Portal ノードと全計算ノードに 追加した VO 用の IS handle を作成します 以下のファイルをコピーして新たな VO 名に変更し 同じディレクトリに配置してください Portal ノード :/home/portal/naregi/conf/is-handle_<vo 名 > 計算ノード :/usr/naregi/sbc/handle/is-handle_<vo 名 > /usr/naregi/sbc/handle/is-as-url-_<vo 名 > 4.3 データグリッドの設定以下の例では NAREGI ミドルウェアのインストールディレクトリを /usr/naregi としています Gfarmメタサーバの設定 Gfarm メタデータサーバ naregi-gfarm において ユーザ root で VO を追加します オプション -v で VO 名を オプション -l でデータベースの保存先ディレクトリを指定しています なおオプションの詳細は 管理者ガイド NAREGI ミドルウェア DataGrid 27

40 を参照してください mkdir backup cp /usr/naregi/etc/gfarm/* backup/ バックアップを作成 config-gfarm-vo -l /usr/naregi/var/gfarm-metadata -a gsi -v rpmtes t2 VO を追加 Gfarm ファイルシステムノードの設定 Gfarm メタサーバ naregi-gfarm の /usr/naregi/etc/gfarm/vo 名 _gfarm.conf を Gfarm ファ イルシステムノードすべてに複製します 次の例では scp コマンドを用いて複製してい ます scp /usr/naregi/etc/gfarm/* naregi-duft:/usr/naregi/gfarm/etc/gfarm/ Gfarm ファイルシステムノード各々にコピー 次に Gfarm メタサーバおよび Gfarm ファイルシステムノード各々において ユーザ root で gfs デーモンを再起動し スプールディレクトリを設定します export PATH=/usr/naregi/bin:$PATH コマンドへの PATH を設定 /etc/init.d/gfsd restart gfs デーモンの再起動 config-gfsd-vo -v rpmtest2 /usr/naregi/var/gfarm-spool VO に対しスプールディレクトリを設定 Gfarm ファイルシステムノード naregi-duft についても上記と同じ手順を実施します データグリッドアクセス管理システムの設定 Portal ノード naregi-portal において ユーザ portal でデータグリッドアクセス管理シス テムの設定ファイル dg.prop.xml に VO の設定を追加します ここで 設定する URL は Gfarm 用 GridFTP サーバのアドレスです ~]$ vi /usr/naregi/tomcat5/shared/classes/dg.prop.xml 設定ファイルを編集 ( 略 ) <entry key="dams.gfarm.gridftp.rpmtest2">naregi-gfarm.naregi.org:2811</entry > ( 略 ) 28

41 下線部分を追加 データグリッド資源管理システムの設定 Gfarm メタデータサーバ naregi-gfarm において ユーザ globus で次のコマンドを実行 し データグリッド資源管理システムの設定ファイル dgmonitor.xml を作成します ここ で dgmonitor.xml は dai_installer.pl の実行ディレクトリに生成されます cd /usr/naregi/drms mv dgimporter.xml dgimporter.xml.bak 既存ファイルが存在する場合は退避 mv $GLOBUS_LOCATION/etc/ogsadai_wsrf $GLOBUS_LOCAT ION/ogsadai_wsrf_bak 既存の設定ファイル群を退避 OGSA-DAI インストールおよび設定スクリプトを実行 /etc/init.d/globus stop Globus コンテナを停止 /etc/init.d/globus start Globus コンテナを起動 次に 作成した dgmonitor.xml を Portal ノード naregi-portal にコピーします この際 Portal ノード上のユーザは portal であることに注意ください なお Portal ノード上に既存の設定ファイル (/usr/naregi/tomcat5/webapps/datagrid/web-inf/classes/dgmonitor.xml) が存在する場合は 念のため 予め退避することを推奨します scp dgmonitor.xml apps/datagrid/web-inf/classes/ Portal ノードへユーザ portal でコピー 設定を有効にするために Tomcat を再起動します 29

42 5. 証明書の更新 5.1 ホスト ( サーバ ) 証明書の更新 構成例 本節で用いる構成例は次の通りです 表 ノード構成例 ノード種別 ノード名 旗艦ノード ( 兼 CA/RA ノード ) naregi-cara.naregi.org Portal ノード naregi-portal.naregi.org SS ノード naregi-ss.naregi.org IS-NAS ノード naregi-isnas.naregi.org IS-CDAS ノード naregi-iscdas.naregi.org GridVM 管理ノード ( 兼 GridVM 計算ノード ) naregi-gvms1.naregi.org GridVM 計算ノード naregi-gvmc1.naregi.org DG-Gfarm-VO ノード naregi-gfarm.naregi.org DG-DGUFT ノード naregi-dguft.naregi.org UMS ノード naregi-ums.naregi.org /C=JP/O=naregi/OU=togo 表 認証局 DN 例 DN 新規ホスト証明書の発行認証局より新しいホスト証明書を入手します 入手については各センターの運用規定に従ってください 旗艦ノードへのホスト証明書の保存認証局が発行した新規証明書 ( ホスト証明書 CA 証明書 ) と作成した秘密鍵ファイルを 旗艦ノードの /usr/naregi/cert/host/ 各ノード名 (FQDN) 配下に保存します なお保存にあたっては 証明書と秘密鍵ファイルを次のように保存してください 30

43 種類 ファイル名 Owner Group Permission ホスト証明書 hostcert.pem root root 711 秘密鍵ファイル hostkey.pem root root 711 CA 証明書 naregica.cer root root 711 ~]# cd /usr/naregi/cert/host host]# ls -l total 104 drwx--x--x 2 root root 4096 May 13 18:10 naregi-cara.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-dguft.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-gfarm.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-gvmc1.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-gvms1.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-iscdas.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-isnas.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-portal.naregi.org drwx--x--x 2 root root 4096 May 13 18:10 naregi-ss.naregi.org 旗艦ノード CA/RA ノード以外 [root@naregi-cara host]# cd naregi-ss.naregi.org [root@naregi-cara naregi-ss.naregi.org]# ls -l SS ノードの例 total 24 -rwx--x--x 1 root root 1062 May 13 18:10 hostcert.pem ホスト証明書 -rwx--x--x 1 root root 891 May 13 18:10 hostkey.pem 秘密鍵ファイル -rwx--x--x 1 root root 1176 May 13 18:10 naregica.cer CA 証明書 [root@naregi-cara naregi-ss.naregi.org]# サービスの停止 (1) UMSノード以外のノード NAREGI ミドルウェアの各サービスを一括停止します 停止手順は NAREGI ミドルウェア導入手引書 2.9.1(3) NAREGI サービスの一括停止 を参照ください (2) UMS ノード UMS ノード上のサービスを停止します 停止手順は 1.3.2(7) UMS ノード を参照ください 31

44 5.1.5 証明書の更新 旗艦ノードへのホスト証明書の保存 で保存した証明書と秘密鍵ファイルを 表 ノード構成例 の旗艦ノード ( 兼 CA/RA ノード ) 以外のノードへ配置します なお以下の例では scp コマンドを用いていますが ftp コマンドや rcp コマンドでも構 いません (1) GridVM 計算ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvmc1.naregi.org/hostcert.pem ho stcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvmc1.naregi.org/hostkey.pem ho stkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvmc1.naregi.org/naregica.cer na regica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 32

45 (2) GridVM 管理ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvms1.naregi.org/hostcert.pem ho stcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvms1.naregi.org/hostkey.pem ho stkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gvms1.naregi.org/naregica.cer nar egica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 (3) IS-CDAS ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-iscdas.naregi.org/hostcert.pem ho stcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 33

46 旗艦ノードから該当ノード名配下のホスト証明書を取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-iscdas.naregi.org/hostkey.pem hos tkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-iscdas.naregi.org/naregica.cer nar egica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 続いて PostgreSQL の証明書を更新します # /etc/init.d/postgresql stop PostgreSQLサービスの停止 # cd $PGSQL_HOME/data # cp /etc/grid-security/containercert.pem server.crt # chown postgres:postgres server.crt # chmod 644 server.crt # cp /etc/grid-security/containerkey.pem server.key # chown postgres:postgres server.key # chmod 400 server.key PostgreSQL 証明書の更新 # /etc/init.d/postgresql start PostgreSQLサービスの起動 34

47 (4) IS-NAS ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-isnas.naregi.org/hostcert.pem host cert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-isnas.naregi.org/hostkey.pem host key.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-isnas.naregi.org/naregica.cer nare gica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 続いて PostgreSQL の証明書を更新します # /etc/init.d/postgresql stop PostgreSQLサービスの停止 # cd $PGSQL_HOME/data # cp /etc/grid-security/containercert.pem server.crt # chown postgres:postgres server.crt # chmod 644 server.crt # cp /etc/grid-security/containerkey.pem server.key 35

48 # chown postgres:postgres server.key # chmod 400 server.key PostgreSQL 証明書の更新 # /etc/init.d/postgresql start PostgreSQL サービスの起動 (5) SS ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-ss.naregi.org/hostcert.pem hostcer t.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-ss.naregi.org/hostkey.pem hostkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-ss.naregi.org/naregica.cer naregic a.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 # cd /etc/grid-security/vomsdir /etc/grid-security/vomsdir ディレクトリに移動 36

49 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-ums.naregi.org/hostcert.pem host cert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから UMS ノード名配下のホスト証明書を取得し Owner と Permission を変更 (6) Portal ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-portal.naregi.org/hostcert.pem ho stcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-portal.naregi.org/hostkey.pem hos tkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-portal.naregi.org/naregica.cer nar egica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 37

50 続いて Portal 用の証明書を更新します # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # cp containercert.pem portalcert.pem # chown portal:portal portalcert.pem # chmod 644 portalcert.pem Portal 用の証明書を作成し OwnerとPermissionを変更 # cp containerkey.pem portalkey.pem # chown portal:portal portalkey.pem # chmod 400 portalkey.pem Portal 用の秘密鍵を作成し OwnerとPermissionを変更 (7) DG-Gfarm-VO ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gfarm.naregi.org/hostcert.pem ho stcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gfarm.naregi.org/hostkey.pem hos tkey.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-gfarm.naregi.org/naregica.cer nar egica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem 38

51 # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 (8) DG-DGUFT ノード # cd /etc/grid-security /etc/grid-security ディレクトリに移動 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-dguft.naregi.org/hostcert.pem hos tcert.pem # chown root:root hostcert.pem # chmod 644 hostcert.pem 旗艦ノードから該当ノード名配下のホスト証明書を取得し OwnerとPermissionを変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-dguft.naregi.org/hostkey.pem host key.pem # chown root:root hostkey.pem # chmod 400 hostkey.pem 旗艦ノードから該当ノード名配下の秘密鍵ファイルを取得し Owner と Permission を変更 # scp naregi-cara.naregi.org:/usr/naregi/cert/host/naregi-dguft.naregi.org/naregica.cer nare gica.cer # chown root:root naregica.cer # chmod 644 naregica.cer # cp p naregica.cer naregica.pem 旗艦ノードから該当ノード名配下の CA 証明書を取得し Owner と Permission を変更 # cp hostcert.pem containercert.pem # chown globus:globus containercert.pem # chmod 644 containercert.pem Globus コンテナ証明書を作成し Owner と Permission を変更 # cp hostkey.pem containerkey.pem # chown globus:globus containerkey.pem # chmod 400 containerkey.pem Globus コンテナキーを作成し Owner と Permission を変更 39

 

  利用者ガイド NAREGI Middleware UMS (User Management Server) 2008 年 10 月 国立情報学研究所 ドキュメントリスト 管理者ガイドグループ IS(Distributed Information Service) IS(Distributed Information Service) - LRPSConfig - SS(Super Scheduler)

More information

AICryptoライブラリについて

AICryptoライブラリについて 管理者ガイド NAREGI Middleware UMS (User Management Server) 2010 年 11 月 国立情報学研究所 ドキュメントリスト 管理者ガイドグループ 管理者ガイド NAREGI Middleware IS(Distributed Information Service) 管理者ガイド NAREGI Middleware IS(Distributed Information

More information

Microsoft Word doc

Microsoft Word doc NAREGI(version beta 1.0.1) 環境の構築 名古屋大学情報連携基盤センター永井亨 1. はじめに名古屋大学情報連携基盤センターでは PC クラスタ上に NAREGI ミドルウェア (version beta 1.0.1) によるグリッド環境を構築した 以下でシステムの概要を報告する 2. システム構築システム構築は年 5 月に開始し 8 月に終了した 構築にあたって発生した障害等を付表に示す

More information

Copyright National Institute of Informatics, Japan. All rights reserved. This file or a portion of this file is licensed under the terms of

Copyright National Institute of Informatics, Japan. All rights reserved. This file or a portion of this file is licensed under the terms of NAREGI Middleware 導入手引書 V 1.1 2008 年 10 月 国立情報学研究所 Copyright 2004-2008 National Institute of Informatics, Japan. All rights reserved. This file or a portion of this file is licensed under the terms of

More information

OpenAM 9.5 インストールガイド オープンソース ソリューション テクノロジ ( 株 ) 更新日 : 2013 年 7 月 19 日 リビジョン : 1.8

OpenAM 9.5 インストールガイド オープンソース ソリューション テクノロジ ( 株 ) 更新日 : 2013 年 7 月 19 日 リビジョン : 1.8 OpenAM 9.5 インストールガイド オープンソース ソリューション テクノロジ ( 株 ) 更新日 : 2013 年 7 月 19 日 リビジョン : 1.8 目次 1. はじめに 1 1.1 本文書の目的... 1 1.2 前提条件... 1 1.3 略語...1 2. 事前準備 2 2.1 ホスト名の名前解決... 2 3. Linix 版パッケージ 3 3.1 システム要件... 3 3.1.1

More information

SLAMD導入手順

SLAMD導入手順 SLAMD 導入手順 2007 年 5 月 日本 LDAP ユーザ会 関口薫 目次 1 はじめに...1 1.1 目的...1 1.2 SLAMD とは...1 1.3 ソフトウェア環境...2 2 LDAP サーバのインストール 設定...2 2.1 SLAMD の設定...2 2.2 OpenLDAP の設定...3 3 SLAMD サーバのインストール 設定...3 3.1 JDK のインストール...3

More information

SecureAssist Enterprise Portal アップグレードガイド Version 対応版 パッケージのダウンロード アップグレード全体の流れ アップグレード作業の詳細手順

SecureAssist Enterprise Portal アップグレードガイド Version 対応版 パッケージのダウンロード アップグレード全体の流れ アップグレード作業の詳細手順 2016.09.29 SecureAssist Enterprise Portal アップグレードガイド Version 3.0.3 対応版 パッケージのダウンロード アップグレード全体の流れ 目次 * 本資料について * SecureAssist Enterprise Portal アップグレード準備パッケージのダウンロード * SecureAssist Enterprise Portal アップグレード作業の概要

More information

InterSafe_Sales_Guide

InterSafe_Sales_Guide URL フィルタリングソフト InterSafe v6.x Java メモリ修正パッチ 目次 はじめに 3 1. 適用手順 3 1-1. Windows 版 4 適用手順 4 適用結果の確認 4 1-2. Linux 版 5 適用手順 5 適用結果の確認 5 1-3. Solaris 版 6 適用手順 6 適用結果の確認 6 はじめに InterSafe WebFilter Ver.6.0 および

More information

Microsoft Word - WE-InstMan382J sol.doc

Microsoft Word - WE-InstMan382J sol.doc WebEdge 3.8.2J インストール ガイド マニュアル バージョン 3.8.2 2007 年 12 月 Open Technologies 目次 1. WebEdge 3.8.2 のインストール... 1 1.1 必要とされるシステム... 1 1.1.1 ハードウェア... 1 1.1.2 ソフトウェア... 1 1.1.3 必要とされるプラウザ... 1 1.1.4 必要な設定情報...

More information

 

  管理者ガイド NAREGI Middleware Mediator 2008 年 10 月 国立情報学研究所 ドキュメントリスト 管理者ガイドグループ 管理者ガイド NAREGI Middleware IS(Distributed Information Service) 管理者ガイド NAREGI Middleware IS(Distributed Information Service) - LRPSConfig

More information

Cuoreテンプレート

Cuoreテンプレート R 1.1 株式会社クオーレ < 1 > 目次 1 XAMPP の設定を行う... 3 1.1 ダウンロード... 3 1.2 初期設定... 4 1.2.1 Apache MySQL の起動... 5 2 ソースコードをダウンロードする... 6 3 WEB サーバにソースコードをアップロードする... 7 4 インストール... 8 5 POSTGRESQL をインストールする... 13 5.1

More information

Microsoft Word - Win-Outlook.docx

Microsoft Word - Win-Outlook.docx Microsoft Office Outlook での設定方法 (IMAP および POP 編 ) How to set up with Microsoft Office Outlook (IMAP and POP) 0. 事前に https://office365.iii.kyushu-u.ac.jp/login からサインインし 以下の手順で自分の基本アドレスをメモしておいてください Sign

More information

intra-mart ワークフローデザイナ

intra-mart ワークフローデザイナ intra-mart ワークフローデザイナ Version 5.0 インストールガイド 初版 2005 年 6 月 17 日 変更年月日 2005/06/17 初版 > 変更内容 目次 > 1 はじめに...1 1.1 インストールの概要...1 1.2 用語について...1 1.3 前提条件...1 2 インストール手順...2 2.1 サーバへのファイルのインストール...2

More information

Linkexpress トラブル初期調査資料 採取コマンド使用手引書

Linkexpress トラブル初期調査資料 採取コマンド使用手引書 FUJITSU Software Linkexpress Standard Edition V5.0L15 Linkexpress Enterprise Edition V5.0L15 Linkexpress トラブル初期調査資料採取コマンド使用手引書 Windows/Windows(64) J2X1-2740-14Z0(00) 2014 年 12 月 まえがき 本書の目的 本書は 下記製品でエラーが発生した場合の初期調査資料の採取方法を説明します

More information

Helix Swarm2018.1アップグレード手順

Helix Swarm2018.1アップグレード手順 2018 Helix Swarm2018.1 アップグレード手順 パッケージインストール編 目次 はじめに. 2 アップグレードの流れ 2 1. アップグレード準備. 3 1.1 リポジトリ設定の追加.. 3 1.2 GPG キー ( 公開鍵 ) インストール. 4 1.3 EPEL パッケージのインストール 4 2. Helix Swarm/ オプショナルパッケージのアップグレード 5 2.1 Helix

More information

Mental ray for Maya インストール手順 1 Mental ray plug-in のインストール 1.1 下記リンクの NVIDIA mental ray の製品ページにて必要事項を記入し 必要なバージョンのチェックボックスを入れてから 今すぐダウンロード をクリックすると 記載し

Mental ray for Maya インストール手順 1 Mental ray plug-in のインストール 1.1 下記リンクの NVIDIA mental ray の製品ページにて必要事項を記入し 必要なバージョンのチェックボックスを入れてから 今すぐダウンロード をクリックすると 記載し Mental ray for Maya インストール手順 1 Mental ray plug-in のインストール 1.1 下記リンクの NVIDIA mental ray の製品ページにて必要事項を記入し 必要なバージョンのチェックボックスを入れてから 今すぐダウンロード をクリックすると 記載したメールアドレス宛にダウンロードリンクが送られてくるのでインストーラーを入手する http://www.nvidia.co.jp/object/download-mental-ray-jp.html

More information

App Bridge Monitor Linux Agent インストールガイド Ver.1.9.0

App Bridge Monitor Linux Agent インストールガイド Ver.1.9.0 App Bridge Monitor Linux Agent インストールガイド Ver.1.9.0 目次 1. 本書の役割... 1 2. 監視対象ノードの登録... 2 3.Agent のインストール... 7 3.1 監視対象サーバへのログイン... 7 3.2 セットアップファイルのダウンロード... 7 3.3 インストール... 7 3.4 初期設定... 8 3.5 サービスの起動...

More information

目次 1. 動作環境チェック 動作必要環境 Java のインストール Java のインストール Firebird のインストール Firebird のインストール Adobe Reader のインストール

目次 1. 動作環境チェック 動作必要環境 Java のインストール Java のインストール Firebird のインストール Firebird のインストール Adobe Reader のインストール ORCA PROJECT Linux 対応版インストールマニュアル (Version 2.0.0 対応 ) Ubuntu 10.04 Lucid 用 2.0.0 版 2013 年 3 月 8 日 目次 1. 動作環境チェック...3 1.1. 動作必要環境...3 2. Java のインストール...3 2.1. Java のインストール...3 3. Firebird のインストール...4 3.1.

More information

目次 1. はじめに 本文書の目的 前提条件 略語 事前準備 ホスト名の名前解決 Linux 版パッケージ システム要件 ソフトウェア要件 パッケージ構成

目次 1. はじめに 本文書の目的 前提条件 略語 事前準備 ホスト名の名前解決 Linux 版パッケージ システム要件 ソフトウェア要件 パッケージ構成 OpenAM 11 インストールガイド オープンソース ソリューション テクノロジ ( 株 ) 作成日 : 更新日 : 2013 年 12 月 26 日 2018 年 10 月 15 日 リビジョン : 1.7 目次 1. はじめに 1 1.1 本文書の目的...1 1.2 前提条件...1 1.3 略語...1 2. 事前準備 2 2.1 ホスト名の名前解決...2 3. Linux 版パッケージ

More information

ELC 5.3

ELC 5.3 AppWave Enterprise License Center 5.3 インストール & セットアップ簡易ガイド もくじシステム要件... 1 リファレンス... 1 ELC 5.3 のダウンロード... 1 ELC 4.2 からのアップグレード... 1 インストール... 1 セットアップ... 3 Web ホスティングサイトによるライセンスのホスト設定... 8 クライアントライセンスの配布...

More information

別紙 : 検証環境の構築手順 ( 章 ) 1. サーバ設定 1.1 IP アドレス設定 サーバは以下の 6 台を用いる pgpool-ii サーバ 2 台 DB サーバ 3 台 上位サーバ 1 台 OS は全サーバで CentOS 6.4 x86_64 とする pgpool-ii のサー

別紙 : 検証環境の構築手順 ( 章 ) 1. サーバ設定 1.1 IP アドレス設定 サーバは以下の 6 台を用いる pgpool-ii サーバ 2 台 DB サーバ 3 台 上位サーバ 1 台 OS は全サーバで CentOS 6.4 x86_64 とする pgpool-ii のサー 別紙 : 検証環境の構築手順 (13.1.1 章 ) 1. サーバ設定 1.1 IP アドレス設定 サーバは以下の 6 台を用いる pgpool-ii サーバ 2 台 DB サーバ 3 台 上位サーバ 1 台 OS は全サーバで CentOS 6.4 x86_64 とする pgpool-ii のサーバは NIC を 3 つ持っているとする (eth0, eth1, eth2) このうち eth0 をサービス提供と

More information

セットアップカード

セットアップカード R3.4 セットアップカード - 第 1.01 版 - Copyright NEC Corporation 2003-2016. All rights reserved. 商標について LogCollector は日本電気株式会社の登録商標です Microsoft Windows Windows Server Windows Vista Internet Explorer および SQL Server

More information

インテル® Parallel Studio XE 2019 Composer Edition for Fortran Windows : インストール・ガイド

インテル® Parallel Studio XE 2019 Composer Edition for Fortran Windows : インストール・ガイド インテル Parallel Studio XE 2019 Composer Edition for Fortran Windows インストール ガイド エクセルソフト株式会社 Version 1.0.0-20180918 目次 1. はじめに....................................................................................

More information

Apache2.2(mod_ssl) は ECDSA 鍵について非対応となっております 1-2. 証明書のインストール Apache(mod_ssl) への証明書のインストール方法について記述します 事前準備 事前準備として サーバ証明書 中間 CA 証明書を取得してください 事前準備

Apache2.2(mod_ssl) は ECDSA 鍵について非対応となっております 1-2. 証明書のインストール Apache(mod_ssl) への証明書のインストール方法について記述します 事前準備 事前準備として サーバ証明書 中間 CA 証明書を取得してください 事前準備 Apache(mod_ssl) 編 改版履歴 版数 日付 内容 担当 V.1.1 2014/12/22 初版 NII V.1.2 2015/5/15 中間 CA 証明書のファイル名を修正 NII V.1.3 2015/12/11 サーバ証明書設定について注釈を追加 NII V.2.0 2018/2/26 SHA1の記載内容の削除 NII V.2.1 2018/3/26 CT 対応版の中間 CA 証明書について説明を追加

More information

dvi

dvi { SSH { 3 3 1 telnet ID ( ) ID ( 1) SSH(Secure SHell) (ID ) SSH SSH SSH login : userid password : himitsu login : userid psaaword: himitsu login : userid password : himitsu 1. Host 11 7 UNIX ( sakura)

More information

FUJITSU Storage ETERNUS BE50 S2 運用ガイド Symantec Backup Exec 2014 修正適用編

FUJITSU Storage ETERNUS BE50 S2 運用ガイド Symantec Backup Exec 2014 修正適用編 FUJITSU Storage ETERNUS BE50 S2 運用ガイド Symantec Backup Exec 2014 修正適用編 改版履歴 版数改版日変更内容 1.0 版 2015 年 2 月初版 2 はじめに 本書は FUJITSU Storage ETERNUS BE50 S2 に Backup Exec 2014 の修正プログラムを適用する手順について説明した資料です 本書は 事前の予告なく変更される場合があります

More information

Cybozu SP Apps バージョン 2.1 インストールマニュアル

Cybozu SP Apps バージョン 2.1 インストールマニュアル バージョン 2.1 インストールマニュアル 第 2.3 版 Cybozu はじめに はじめに このマニュアルでは SharePoint Server 2013 に Cybozu SP Apps バージョン 2.1.x をインストールする方法や 最新のバージョンにバージョンアップする方法を説明します 対象読者 Cybozu SP Apps をインストールする管理者 本書で使用している表記本書では 次の表記を使用しています

More information

インテル® Parallel Studio XE 2019 Composer Edition for Fortran Windows 日本語版 : インストール・ガイド

インテル® Parallel Studio XE 2019 Composer Edition for Fortran Windows 日本語版 : インストール・ガイド インテル Parallel Studio XE 2019 Composer Edition for Fortran Windows 日本語版インストール ガイド エクセルソフト株式会社 Version 2.1.0-20190405 目次 1. はじめに.................................................................................

More information

はじめに このドキュメントではftServerに関する障害調査を行う際に 必要となるログ データの取得方法を説明しています ログ データの取得には 初期解析用のデータの取得方法と 詳細な調査を行うときのデータ取得方法があります 特別な理由でOS 側のログが必要となった場合には RHELログの取得につ

はじめに このドキュメントではftServerに関する障害調査を行う際に 必要となるログ データの取得方法を説明しています ログ データの取得には 初期解析用のデータの取得方法と 詳細な調査を行うときのデータ取得方法があります 特別な理由でOS 側のログが必要となった場合には RHELログの取得につ ftserver におけるログ取得手順 (Linux 編 ) Rev 0.5: 2017/06/08 1 はじめに このドキュメントではftServerに関する障害調査を行う際に 必要となるログ データの取得方法を説明しています ログ データの取得には 初期解析用のデータの取得方法と 詳細な調査を行うときのデータ取得方法があります 特別な理由でOS 側のログが必要となった場合には RHELログの取得について

More information

OSSTechドキュメント

OSSTechドキュメント OSSTech 製 OpenLDAP 2.4 パッケージ インストールガイド オープンソース ソリューション テクノロジ ( 株 ) 作成日 : 2012 年 3 月 30 日 更新日 : 2016 年 5 月 13 日 リビジョン : 4.7 目次 1. はじめに 1 2. Linux 版 OpenLDAP 2.4 パッケージ 2 2.1 システム要件...2 2.1.1 ソフトウェア要件...2

More information

SonicDICOM Cloud Connector インストール手順書 SonicDICOM Cloud Connector とは 検査装置が撮影した画像を自動的にクラウドへアップロー ドするためのソフトウェアです 1 前準備 クラウド上に PACS を作成する SonicDICOM Cloud

SonicDICOM Cloud Connector インストール手順書 SonicDICOM Cloud Connector とは 検査装置が撮影した画像を自動的にクラウドへアップロー ドするためのソフトウェアです 1 前準備 クラウド上に PACS を作成する SonicDICOM Cloud SonicDICOM Cloud Connector インストール手順書 SonicDICOM Cloud Connector とは 検査装置が撮影した画像を自動的にクラウドへアップロー ドするためのソフトウェアです 1 前準備 クラウド上に PACS を作成する SonicDICOM Cloud Connector を動作させるには SonicDICOM PACS Cloud でアカウント登録しクラウド上に

More information

Windows Phone 用 Cisco AnyConnect セキュアモビリティクライ アントユーザガイド(リリース 4.1.x)

Windows Phone 用 Cisco AnyConnect セキュアモビリティクライ アントユーザガイド(リリース 4.1.x) Windows Phone 用 Cisco AnyConnect セキュアモビリティクライアントユーザガイド ( リリース 4.1.x) AnyConnect ユーザガイド 2 AnyConnect の概要 2 Windows Phone サポート対象デバイス 2 Windows Phone 上の AnyConnect のインストールまたはアップグレード 3 Windows Phone デバイス上の

More information

Airwave_upgrade.pdf

Airwave_upgrade.pdf Aruba Networks 社 Airwave バージョンアップ手順書 複製禁止 取扱注意 平成 25 年 7 月 1 目次 1. はじめに... 3 2. 事前準備... 4 2.1. 準備するもの... 4 2.2. アップグレードパス... 4 2.3. 32BITOS と 64BITOS について... 5 3. 事前作業... 6 3.1. 定期バックアップファイルの取得... 6 3.2.

More information

SystemDirector Developer's Studio(V3.2) 適用ガイド

SystemDirector Developer's Studio(V3.2) 適用ガイド 目次 2.7. TPTPの初期設定... 2 2.7.1. Agent Controllerのインストール 設定および起動...2 2.8. CVSのインストール... 3 2.8.1. CVSNT2.5.02 のインストール...3 2.8.2. cvsntのcvsリポジトリー作成...4 2.8.3. cvsntのユーザ作成...5 2.8.4. cvs-1.11.20 のインストール...6

More information

Cybozu SP Apps インストールマニュアル

Cybozu SP Apps インストールマニュアル インストールマニュアル 第 2.4 版 Cybozu はじめに はじめに このマニュアルでは SharePoint 2010 に Cybozu SP Apps バージョン 1.1.x をインストールする方法や 最新のバージョンにバージョンアップする方法を説明します 対象読者 Cybozu SP Apps をインストールする管理者 本書で使用している表記 本書では 次の表記を使用しています 表記 意味

More information

SAMBA Stunnel(Windows) 編 1. インストール 1 セキュア SAMBA の URL にアクセスし ログインを行います xxx 部分は会社様によって異なります xxxxx 2 Windows 版ダウンロード ボ

SAMBA Stunnel(Windows) 編 1. インストール 1 セキュア SAMBA の URL にアクセスし ログインを行います   xxx 部分は会社様によって異なります xxxxx 2 Windows 版ダウンロード ボ 操作ガイド Ver.2.3 目次 1. インストール... - 2-2. SAMBA Stunnel 利用... - 8-2.1. 接続確認... - 8-2.2. 編集... - 11-2.3. インポート... - 14-2.4. 削除... - 15-2.5 フォルダショートカットの作成... - 16-3. 動作環境... - 18-4. 参考資料 ( 接続状況が不安定な場合の対処方法について

More information

Oracle Business Intelligence Standard Edition One のインストール

Oracle Business Intelligence Standard Edition One のインストール Oracle Business Intelligence Standard Edition One のインストール 第 1 版 作成日 :2007 年 7 月 31 日 更新日 :2007 年 7 月 31 日 目次 はじめに... 3 Ⅰ. インストール作業... 4 Ⅱ. 起動状況の確認... 8 Ⅱ-1. Oracle BI Administration Tool の起動... 8 Ⅱ-2.

More information

Microsoft Word - JRE_Update_6.doc

Microsoft Word - JRE_Update_6.doc WebSAM DeploymentManager (HP-UX) における Java 2 Runtime Environment の更新について Rev.6 2008 年 4 月 NEC 本文書では WebSAM DeploymentManager (HP-UX) をご使用のお客様におきまして Java 2 Runtime Environment を更新する際の手順についてお知らせいたします Java

More information

CLUSTERPRO MC StorageSaver 1.1 for Linux リリースメモ 2015(Jun) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル 補足事項 注意事項

CLUSTERPRO MC StorageSaver 1.1 for Linux リリースメモ 2015(Jun) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル 補足事項 注意事項 リリースメモ 2015(Jun) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル 補足事項 注意事項 はしがき 本書は ( 以後 StorageSaver と記載します ) の 動作に必要な手順について説明します (1) 商標および登録商標 Red Hat は 米国およびその他の国における Red Hat,Inc. の商標または登録商標です SUSE

More information

Application Note Application Note No. ESC-APN 文書番号 : ESC-APN Tcl link library インストールガイド はじめに Tcl link library インストールガイド ( 以下 本書 ) では Act

Application Note Application Note No. ESC-APN 文書番号 : ESC-APN Tcl link library インストールガイド はじめに Tcl link library インストールガイド ( 以下 本書 ) では Act No. ESC-APN-006-05 文書番号 : ESC-APN-006-05 Tcl link library インストールガイド はじめに Tcl link library インストールガイド ( 以下 本書 ) では ActiveState Software Inc.( 以下 ActiveState 社 ) のフリーソフトウェアである Active Tcl と microview-plus

More information

ActiveImage Protector 2016 R2 for Express5800 / ftサーバ

ActiveImage Protector 2016 R2 for Express5800 / ftサーバ ActiveImage Protector 2016 R2 for Express5800/ft サーバ VMware ESX/ESXi システムのバックアップ 復元ガイド Express5800/R320e-E4/M4 Express5800/R320f-E4/M4 VMware 対応モデル用 第 1 版 - 2018 年 4 月 10 日 Copyright 2018 NetJapan, Inc.

More information

ServerView with Data ONTAP-v™ PowerChute® Network Shutdown 設定について

ServerView with Data ONTAP-v™ PowerChute® Network Shutdown 設定について ServerView with Data ONTAP-v TM PowerChute Network Shutdown 設定について 富士通株式会社 2011 年 6 月 目次 1. はじめに...2 2. 待ち時間の計画...2 3. PowerChute Network Shutdown のインストール...4 4. PowerChute Network Shutdown の設定...7 5.

More information

Red Hat Enterprise Linuxのcron(8)デーモンにデフォルト定義されたtmpwatch命令の動作による、WebOTXのトラブル対処方法

Red Hat Enterprise Linuxのcron(8)デーモンにデフォルト定義されたtmpwatch命令の動作による、WebOTXのトラブル対処方法 Red Hat Enterprise Linux の cron(8) デーモンにデフォルト定義された tmpwatch 命令の動作による WebOTX のトラブル対処方法 2009 年 2 月 NEC 第二システムソフトウェア事業部 1. 概要 Red Hat Enterprise Linux では OS インストール後の初期状態において cron(8) デーモンによって実行される命令が複数定義されます

More information

【Alfresco勉強会】セットアップ&インストール_pptx

【Alfresco勉強会】セットアップ&インストール_pptx Alfresco勉強会 初期インストール編 株式会社ヴィセント 2014年 2014年5月21日 21日 Copyright 2014 Vicent Co.,Ltd All right reserved 1 内容 勉強会の環境について Alfresco One トライアル版ダウンロード さくらクラウドへの接続 基本情報 Alfresco One トライアル版インストール Copyright 2014

More information

Access Manager 3.2/4.0 証明書の有効期限の確認と更新手順について

Access Manager 3.2/4.0 証明書の有効期限の確認と更新手順について Access Manager 3.2/4.0 の証明書の有効期限の確認と更新手順について 1. Access Manager 証明書の有効期限について Access Manager 3.2 および 4.0 ( 以下 Access Manager) のサーバ証明書については下記の期限があり 製品仕様に基づき定期的に更新 (2 年間延長 ) する必要がございます 新規環境構築時 10 年 ただし Admin

More information

Office 365監査ログ連携機能アクティブ化手順書

Office 365監査ログ連携機能アクティブ化手順書 Discoveries InSite IntelliReport Office 365 監査ログ連携機能アクティブ化手順書 第四版 2018 年 6 月 26 日 Copyright 2018 Discoveries Inc. All Rights Reserved 目次 1 はじめに... 1 本書の目的... 1 作業対象者... 1 2 作業手順... 2 Office 365 監査機能のアクティブ化...

More information

目次 1 環境 バージョン インストール環境 インストール手順 前提条件 CentOS SSHD の設定 VSFTPD の設定 コンテンツ管理 CGI のイ

目次 1 環境 バージョン インストール環境 インストール手順 前提条件 CentOS SSHD の設定 VSFTPD の設定 コンテンツ管理 CGI のイ 私立大学情報教育協会 教育コンテンツ相互利用システム コンテンツ管理 CGI インストールマニュアル 目次 1 環境... 3 1.1 バージョン... 3 1.2 インストール環境... 3 2 インストール手順... 4 2.1 前提条件... 4 2.1.1 CentOS... 4 2.2 SSHD の設定... 7 2.3 VSFTPD の設定... 8 2.4 コンテンツ管理 CGI のインストール...

More information

PowerPoint Presentation

PowerPoint Presentation 製品ソフトウェアのセットアップ手順 UNIX/Linux 編 1. セットアップファイルの選択開発環境 / 実行環境 / バージョン /Hotfix/ インストール先 OS 2. 対象セットアップファイルのダウンロード開発環境の場合は 2 つのファイルが対象 3. ソフトウェア要件の確認 4. ソフトウェアのインストール 5. ライセンスの認証 1 1. セットアップファイルの選択 選択項目選択肢該当チェック

More information

<MW-400k > InterSec/MW400k アップデート適用手順書 2017 年 8 月 1 版

<MW-400k > InterSec/MW400k アップデート適用手順書 2017 年 8 月 1 版 InterSec/MW400k アップデート適用手順書 2017 年 8 月 1 版 改版履歴 版数 改版日付 内容 1 2017 年 8 月 新規作成 - 2 - 目次 商標について... - 4 - はじめに... - 5 - アップデートモジュール適用時の注意 制限事項...- 6 - スタンドアロン構成...- 6 - フェイルオーバクラスタ構成...- 7-1.

More information

Microsoft Word - winscp-LINUX-SCPを使用したファイル転送方法について

Microsoft Word - winscp-LINUX-SCPを使用したファイル転送方法について 作成 : 平成 18 年 2 月 28 日 修正 : 平成 27 年 3 月 4 日 SCP を使用したファイル転送方法について 目次 1. はじめに... 1 2. WinSCP のインストール... 2 2.1. ダウンロード... 2 2.2. インストール... 2 3. WinSCP の使用... 7 3.1. 起動... 7 3.2. 設定... 7 3.3. 接続... 9 3.4.

More information

WebOTXプロファイラを使用したメモリリーク調査方法

WebOTXプロファイラを使用したメモリリーク調査方法 WebOTX プロファイラを使用したメモリリーク調査方法 2006 年 10 月初版 改版履歴 i 目次 1. はじめに...1 2. OutOfMemoryErrorの確認...1 3. JavaVMのヒープ使用量の確認...2 4. WebOTXプロファイラの利用...5 4.1. WebOTXプロファイラを利用するための設定...5 4.1.1. ドメインのJavaVMオプションにプロファイラのオプションの追加...5

More information

Microsoft Word - D JP.docx

Microsoft Word - D JP.docx Application Service Gateway Thunder/AX Series vthunder ライセンスキー インストール 手順 1 1.... 3 2. vthunder... 3 3. ACOS... 3 4. ID... 5 5.... 8 6.... 8 61... 8 62 GUI... 10 2 1. 概要 2. vthunder へのアクセス 方法 SSHHTTPSvThunder

More information

CLUSTERPRO X for Windows PPガイド

CLUSTERPRO X for Windows PPガイド CLUSTERPRO X for Windows PP ガイド (WebSAM Storage RepNavi Suite) 2018.06.15 第 03 版 改版履歴版数 改版日付 内容 1 2012/08/10 PPガイドより分冊し 新規作成 2 2012/12/07 3 2018/06/15 機能概要 最新情報の入手先 の記述を更新 機能概要 の記述内容を更新 Copyright NEC Corporation

More information

CLUSTERPRO MC RootDiskMonitor 1.1 for Linux リリースメモ 2013(Sep) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル

CLUSTERPRO MC RootDiskMonitor 1.1 for Linux リリースメモ 2013(Sep) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル リリースメモ 2013(Sep) NEC Corporation ライセンス パッケージのインストール セットアップ マニュアル はしがき 本書は ( 以後 RootDiskMonitor と記載しま す ) の動作に必要な手順について説明します (1) 商標および登録商標 Red Hat は 米国およびその他の国における Red Hat,Inc. の登録商標または商標です SUSE は 米国およびその他の国における

More information

RADIUS サーバを使用して NT のパスワード期限切れ機能をサポートするための Cisco VPN 3000 シリーズ コンセントレータの設定

RADIUS サーバを使用して NT のパスワード期限切れ機能をサポートするための Cisco VPN 3000 シリーズ コンセントレータの設定 RADIUS サーバを使用して NT のパスワード期限切れ機能をサポートするための Cisco VPN 3000 シリーズコンセントレータの設定 目次 概要前提条件要件使用するコンポーネントネットワーク図 VPN 3000 コンセントレータの設定グループの設定 RADIUS の設定 Cisco Secure NT RADIUS サーバの設定 VPN 3000 コンセントレータ用のエントリの設定 NT

More information

スライド 1

スライド 1 TIES v8.5 TIES V8 のインストール方法 TIES 機能モジュールの利用方法 目次 TIES V8のインストール方法について P.2 TIES V8のインストール P.3~11 TIES 機能モジュールのインストール方法について P.12 TIES 機能モジュールのインストール P.13~15 Moodle2.5でのNFSの設定 P.16~18 発行 :NPO 法人 CCC-TIES

More information

HULFT の通信をよりセキュアに HULFT と SSH Tectia を組み合わせたセキュアで強力なファイル転送 Compatibility Note 2008 年 9 月 株式会社セゾン情報システムズの企業内 企業間通信ミドルウェアである HULFT は ファイル転送のアプリケーションとして

HULFT の通信をよりセキュアに HULFT と SSH Tectia を組み合わせたセキュアで強力なファイル転送 Compatibility Note 2008 年 9 月 株式会社セゾン情報システムズの企業内 企業間通信ミドルウェアである HULFT は ファイル転送のアプリケーションとして HULFT の通信をよりセキュアに HULFT と SSH Tectia を組み合わせたセキュアで強力なファイル転送 Compatibility Note 2008 年 9 月 株式会社セゾン情報システムズの企業内 企業間通信ミドルウェアである HULFT は ファイル転送のアプリケーションとして 主に流通業 製造業で大きなシェアを誇るパッケージソフトウェアです SSH Tectia ソリューションを

More information

TSUBAME利用手引き

TSUBAME利用手引き TSUBAME3.0 利用の手引き TSUBAME ポータル編 2018/10/30 東京工業大学学術国際情報センター共同利用推進室 Copyright (C) 2010-2018 GSIC All Rights Reserved. TSUBAME ポータル利用の手引き もご参照ください http://www.t3.gsic.titech.ac.jp/docs/tsubame3.0_portal_users_guide.html

More information

iStorage ソフトウェア VMware vCenter Plug-in インストールガイド

iStorage ソフトウェア VMware vCenter Plug-in インストールガイド istorage ソフトウェア VMware vcenter Plug-in インストールガイド はじめに このインストールガイドでは WebSAM Storage VMware vcenter Plug-in のインストールに関して説明しています 本製品は VMware vcenter Server と連携する製品のため VMware vcenter Server が稼働するサーバへインストー ルします

More information

Dental Photo Scape インストールガイド 第 13 版 歯科医院用画像管理ソフトウェア Dental Photo Scape インストールガイド 東九州ソフトウェア開発 連絡先ホームページ URL 電子メールアドレス : :

Dental Photo Scape インストールガイド 第 13 版 歯科医院用画像管理ソフトウェア Dental Photo Scape インストールガイド 東九州ソフトウェア開発 連絡先ホームページ URL 電子メールアドレス :   : 歯科医院用画像管理ソフトウェア Dental Photo Scape インストールガイド 東九州ソフトウェア開発 連絡先ホームページ URL 電子メールアドレス : http://www.eksd.jp : support@mail.eksd.jp - 1 - 東九州ソフトウェア開発 目次 はじめに... 3 本書について... 3 動作に必要なパーソナルコンピュータの要件... 4 情報の保存場所について...

More information

PowerPoint プレゼンテーション

PowerPoint プレゼンテーション イチからはじめる Linux サーバ構築ハンズオン 事前準備用資料 株式会社リーデックス はじめに 弊社の勉強会にご興味を持っていただきありがとうございます Linuxサーバ構築ハンズオンを受講いただくにあたり 必要なソフトのインストールと環境構築の手順をまとめました 資料はWindows 環境前提で記載してありますが Macでも少しの読み替えで対応できると思います 当日の時間内にインストールからスタートするとインターネットの回線状況によっては環境構築だけで

More information

CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Apr) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (H

CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Apr) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (H CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Apr) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (HP-UX 版 ) istorage M シリーズを使用する場合の StorageSaver 設定手順

More information

目次 1. 改版履歴 概要 WEB 版薬剤在庫管理システムのインストール 事前準備 インストール アプリケーションのセットアップ WEB 版薬剤在庫管理システムの初期設定

目次 1. 改版履歴 概要 WEB 版薬剤在庫管理システムのインストール 事前準備 インストール アプリケーションのセットアップ WEB 版薬剤在庫管理システムの初期設定 WEB 版薬剤在庫管理システム インストール手順 初期設定 初版 2018 年 10 月 01 日 日本医師会 ORCA 管理機構株式会社 目次 1. 改版履歴... 2 2. 概要... 3 3. WEB 版薬剤在庫管理システムのインストール... 4 3-1. 事前準備... 4 3-2. インストール... 5 3-3. アプリケーションのセットアップ... 6 4. WEB 版薬剤在庫管理システムの初期設定...

More information

Linux修正適用手順書

Linux修正適用手順書 PowerChute Business Edition v6.1.2j 改版履歴 2005/07/22 第 1.0 版新規作成 2005/08/05 第 1.1 版誤表記等を一部修正 - 2 - もくじ 1. 本書について...4 2. 作業の流れ...5 3. 適用対象製品の確認...6 3.1. インストール形式の確認...6 3.2.bin ファイルで製品をインストールした場合の確認...7

More information

Microsoft Word - XOOPS インストールマニュアルv12.doc

Microsoft Word - XOOPS インストールマニュアルv12.doc XOOPS インストールマニュアル ( 第 1 版 ) 目次 1 はじめに 1 2 XOOPS のダウンロード 2 3 パッケージの解凍 4 4 FFFTP によるファイルアップロード手順 5 5 ファイルアップロード後の作業 11 6 XOOPS のインストール 15 7 インストール後の作業 22 8 XOOPS ログイン後の作業 24 愛媛県総合教育センター情報教育研究室 Ver.1.0.2

More information

ロードバランサー配下のシボレス IdP 環境設定に関する検証実験 2009 年 12 月 22 日国立情報学研究所学術ネットワーク研究開発センター山地一禎, 中村素典

ロードバランサー配下のシボレス IdP 環境設定に関する検証実験 2009 年 12 月 22 日国立情報学研究所学術ネットワーク研究開発センター山地一禎, 中村素典 ロードバランサー配下のシボレス IdP 環境設定に関する検証実験 2009 年 12 月 22 日国立情報学研究所学術ネットワーク研究開発センター山地一禎, 中村素典 2 1. 目的ロードバランサー配下で複数のシボレス IdP からなるクラスタを構築するための設定方法を調べることを目的とする. 2. 実験環境検証実験は, ロードバランサー 1 台 (F5 ネットワークスジャパン株式会社 BIG-IP),

More information

Server Core適用ガイド

Server Core適用ガイド Systemwalker Service Quality Coordinator Server Core 適用ガイド Windows B1WS-0811-01Z0(00) 2008 年 9 月 まえがき 本書の目的 本書は Systemwalker Service Quality Coordinator V13.3.0 を Microsoft(R) Windows Server(R) 2008 Server

More information

改版履歴 版数 改版日付 改版内容 /03/14 新規作成 2013/03まで製品サイトで公開していた WebSAM DeploymentManager Ver6.1 SQL Server 2012 製品版のデータベース構築手順書 ( 第 1 版 ) を本 書に統合しました 2

改版履歴 版数 改版日付 改版内容 /03/14 新規作成 2013/03まで製品サイトで公開していた WebSAM DeploymentManager Ver6.1 SQL Server 2012 製品版のデータベース構築手順書 ( 第 1 版 ) を本 書に統合しました 2 第 1 版 改版履歴 版数 改版日付 改版内容 1 2013/03/14 新規作成 2013/03まで製品サイトで公開していた WebSAM DeploymentManager Ver6.1 SQL Server 2012 製品版のデータベース構築手順書 ( 第 1 版 ) を本 書に統合しました 2 目次 1. 使用しているデータベース (DPMDBI インスタンス ) を SQL Server

More information



 Thunder ADC( ロードバランサー ) における クライアント証明書認証の設定手順 Ver.1.0 2015 年 9 月 Copyright by JCCH Security Solution Systems Co., Ltd., All Rights reserved JCCH セキュリティ ソリューション システムズ JS3 およびそれらを含むロゴは日本および他の国における株式会社 JCCH

More information

CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Sep) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (H

CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Sep) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (H CLUSTERPRO MC StorageSaver istorage M シリーズ使用時の設定手順 (HP-UX 版 Linux 版 Windows 版 ) 2013(Sep) NEC Corporation istorage M シリーズを使用する場合の StorageSaver 設定手順 (HP-UX 版 ) istorage M シリーズを使用する場合の StorageSaver 設定手順

More information

情報処理概論(第二日目)

情報処理概論(第二日目) 実習資料 Linux 入門講習会 九州大学情報基盤研究開発センター 注意 : この内容は wisdom.cc.kyushu-u.ac.jp の任意の ID で利用できますが, ファイルの削除等を含んでいるので各コマンドの意味を理解するまでは講習会用 ID で利用することをお勧めします. 1 実習 1 ログイン ファイル操作 ディレクトリの作成 ファイルの移動, コピー, 削除 ログアウト 2 ログイン

More information

PowerPoint プレゼンテーション

PowerPoint プレゼンテーション PUBLIS Free 利用するまでに [ 前提 ] この作業フローを実施するには 下記の条件がクリアされている必要があります Microsoft Azure/BizSpark どちらかの環境があること Microsoft アカウントが取得済みであること 1 サブスクリプションファイルを作成する 2 PUBLIS Free を Microsoft Azure/BizSpark に展開する 3 PUBLIS

More information

2. FileZilla のインストール 2.1. ダウンロード 次の URL に接続し 最新版の FileZilla をダウンロードします URL: なお バージョンが異なるとファイル名が

2. FileZilla のインストール 2.1. ダウンロード 次の URL に接続し 最新版の FileZilla をダウンロードします URL:   なお バージョンが異なるとファイル名が 作成 : 平成 18 年 2 月 28 日 修正 : 平成 29 年 5 月 26 日 SFTP を使用したファイル転送方法について 目 次 1. はじめに... 1 2. FileZilla のインストール... 2 2.1. ダウンロード... 2 2.2. インストール... 2 3. FileZilla の使用... 7 3.1. 起動... 7 3.2. 設定... 8 3.3. 接続...

More information

HeartCoreインストールマニュアル

HeartCoreインストールマニュアル HeartCore インストールマニュアル (JSP 版 ) October2013 Ver1.1-1 - 改訂履歴 改訂日 改訂内容 Ver1.0 2013 年 07 月 マニュアル改訂 Ver1.1 2013 年 10 月 フォーマット改訂 - 2 - 目次 1. 本文書の目的と対象...- 4-1.1. 概要説明... - 4-2. インストールの流れ...- 4-3. MySQL ユーザの作成...-

More information

ServerView ESXi CIM Provider VMware vSphere ESXi 6.5 インストールガイド

ServerView ESXi CIM Provider VMware vSphere ESXi 6.5 インストールガイド 2017 年 1 月 11 日富士通株式会社 ServerView ESXi CIM Provider VMware vsphere ESXi 6.5 インストールガイド VMware vsphere ESXi 6.5 をインストールしたサーバを監視 管理する場合 ServerView ESXi CIM Provider を使用するか またはリモートマネジメントコントローラを使用した サーバ監視 管理を行うことができます

More information

Microsoft Windows Internet Explorer は 米国 Microsoft Corporation の 米国およびその他の国における登録商標または商標です Linux は Linus Torvalds 氏の日本およびその他の国における登録商標または商標です Red Hat

Microsoft Windows Internet Explorer は 米国 Microsoft Corporation の 米国およびその他の国における登録商標または商標です Linux は Linus Torvalds 氏の日本およびその他の国における登録商標または商標です Red Hat 作成日 :2017/07/06 ******************************************************************************* ** ** ** FUJITSU Cloud Service K5 ** ** ** ** ソフトウェアカフェテリアサービス向けソフトウェア説明書 ** ** Linux 版 ** ** Interstage

More information

SRX License

SRX License SRX ライセンスキー投入手順 株式会社日立ソリューションズネットワークビジネス部セキュリティグループ リビジョン 4.0 初版 2010/05/30 最新版 2012/12/27 Hitachi Solutions, Ltd. 2010-2012. All rights reserved. SRX ライセンスキー投入手順 Contents 1. ライセンスキーの自動インポート ( インターネット接続必須

More information

WebARENA SuiteX V2 EC-CUBE 2.13 インストールマニュアル ( 標準 MySQL+ 非 SSL ) 作成 :2014 年 2 月 Ver.1.1

WebARENA SuiteX V2 EC-CUBE 2.13 インストールマニュアル ( 標準 MySQL+ 非 SSL ) 作成 :2014 年 2 月 Ver.1.1 WebARENA SuiteX V2 EC-CUBE 2.13 インストールマニュアル ( 標準 MySQL+ 非 SSL ) 作成 :2014 年 2 月 Ver.1.1 注意事項 EC-CUBE は株式会社ロックオンの提供するソフトウェアです ここでは株式会社ロックオンから提供されている EC-CUBE バージョン 2.13 のパッケージをご利用される前提で 基本的な設置手順を掲載しております

More information

Samba Install and Update Guide

Samba Install and Update Guide OSSTech 製 OpenLDAP 2.3 パッケージ インストールガイド v2.0 オープンソース ソリューション テクノロジ ( 株 ) 作成日 : 2008 年 12 月 10 日更新日 : 2010 年 8 月 30 日リビジョン : 2.0 目次 1. はじめに...1 2. OpenLDAP 2.3 パッケージのインストール...2 2.1 対応 Linux ディストリビューション...2

More information

R76/Gaia ブリッジ構成設定ガイド

R76/Gaia ブリッジ構成設定ガイド R76/GAiA ブリッジ構成設定ガイド ( スタンドアロン構成 ) Last updated Aug 16, 2013 Ver 1.0 はじめに 本章の手順は 以下の項目が満たされている事を前提条件としています 事前に GAiA R76 のインストールが完了していること 管理コンソールに SmartConsole がインストールされていること 対象となるアプライアンス機器は Model 2200

More information

手順例_Swivel_SSL証明書

手順例_Swivel_SSL証明書 SSL 証明書作成手順例 ( ご参考 ) 参考 https://kb.swivelsecure.com/wiki/index.php/ssl_certificate_pinsafe_appliance_how_t o_guide 証明書に利用するホスト名は VIP の NAT として登録している userportal.xxxx.co.jp を利用する Webmin 用の SSL 証明書は別物で 自己証明書を継続利用する

More information

目次 1. 改版履歴 概要 WEB 版薬剤在庫管理システムのインストール 事前準備 インストール アプリケーションのセットアップ 日レセと連携するための有効化設定 WEB

目次 1. 改版履歴 概要 WEB 版薬剤在庫管理システムのインストール 事前準備 インストール アプリケーションのセットアップ 日レセと連携するための有効化設定 WEB WEB 版薬剤在庫管理システム インストール手順 初期設定 初版 2018 年 11 月 12 日 日本医師会 ORCA 管理機構株式会社 目次 1. 改版履歴... 2 2. 概要... 3 3. WEB 版薬剤在庫管理システムのインストール... 4 3-1. 事前準備... 4 3-2. インストール... 5 3-3. アプリケーションのセットアップ... 6 3-4. 日レセと連携するための有効化設定...

More information

Sophos Enterprise Console

Sophos Enterprise Console スタートアップガイド 製品バージョン : 5.5 次 このガイドについて...1 システム要件... 2 Linux コンピュータの保護... 3 動による Sophos Anti-Virus の新規インストール... 3 インストールパッケージの作成...3 インストールパッケージを使 した Sophos Anti-Virus のインストール...5 UNIX コンピュータの保護... 6 動による

More information

Microsoft Windows Internet Explorer は 米国 Microsoft Corporation の 米国およびその他の国における登録商標または商標です Linux は Linus Torvalds 氏の日本およびその他の国における登録商標または商標です Red Hat

Microsoft Windows Internet Explorer は 米国 Microsoft Corporation の 米国およびその他の国における登録商標または商標です Linux は Linus Torvalds 氏の日本およびその他の国における登録商標または商標です Red Hat 作成日 :2017/07/06 ******************************************************************************* ** ** ** FUJITSU Cloud Service K5 ** ** ** ** ソフトウェアカフェテリアサービス向けソフトウェア説明書 ** ** Linux 版 ** ** Interstage

More information

Cybozu SP Apps インストールマニュアル

Cybozu SP Apps インストールマニュアル インストールマニュアル 第 2 版 サイボウズ株式会社 はじめに はじめに 本書では SharePoint Server 2007 に Cybozu SP Apps バージョン 1.0.x をインストールする方法を説明しています 対象読者 本書は Cybozu SP Apps バージョン 1.0.x のインストール作業を担当される方を対象として書かれています 本書で使用している表記 表記 意味 注意

More information

ServerView ESXi CIM Provider VMware vSphere ESXi 6.5 インストールガイド

ServerView ESXi CIM Provider VMware vSphere ESXi 6.5 インストールガイド 2017 年 12 月 12 日富士通株式会社 ServerView ESXi CIM Provider VMware vsphere ESXi 6.5 インストールガイド VMware vsphere ESXi 6.5 をインストールしたサーバを監視 管理する場合 ServerView ESXi CIM Provider を使用するか またはリモートマネジメントコントローラを使用した サーバ監視

More information

CLUSTERPRO MC ProcessSaver 2.1 for Linux リリースメモ 2016(Mar) NEC Corporation ライセンス パッケージのインスト ル セットアップ マニュアル 障害発生時の手順 補足事項 注意事項

CLUSTERPRO MC ProcessSaver 2.1 for Linux リリースメモ 2016(Mar) NEC Corporation ライセンス パッケージのインスト ル セットアップ マニュアル 障害発生時の手順 補足事項 注意事項 リリースメモ 2016(Mar) NEC Corporation ライセンス パッケージのインスト ル セットアップ マニュアル 障害発生時の手順 補足事項 注意事項 改版履歴 版数 改版 内容 1.0 2015.03 新規作成 2.0 2016.03 MC 2.1 に対応 i はしがき 本書は ( 以後 ProcessSaver と記載します ) の 動作に必要な手順について説明します (1) 商標および登録商標

More information

eYACHO 管理者ガイド

eYACHO 管理者ガイド eyacho 管理者ガイド 第 1 版 - ios は Cisco の米国およびその他の国における商標または登録商標であり ライセンスに基づき使用されています - Apple ipad は Apple Inc. の商標です - Microsoft, Excel および Internet Explorer は 米国 Microsoft Corporation の 米国およびその他の国における登録商標または商標です

More information

Microsoft Word - SSL-VPN接続サービスの使い方

Microsoft Word - SSL-VPN接続サービスの使い方 作成 : 平成 29 年 06 月 29 日 更新 : 平成 30 年 07 月 28 日 SSL-VPN 接続サービスの使い方 内容 SSL-VPN 接続サービスの使い方... 1 1. SSL-VPN 接続サービスについて... 1 2. SSL-VPN 接続サービスの留意点... 1 3. SSL-VPN 接続サービスの利用に必要となるもの... 2 4. SSL-VPN 接続サービスを利用する手順...

More information

新OS使用時の留意事項

新OS使用時の留意事項 2014 年 3 月富士通株式会社 新 OS 使用時の留意事項 Fujitsu Software Interstage Print Manager( 以降 Interstage Print Manager) の動作オペレーティングシステムに以下をサポートします Windows 8 Windows 8.1 2012 2012 R2 この動作環境においても従来と同等の機能をご利用になれますが ご利用に関しての留意事項について説明します

More information

Microsoft Word - ShareFastClientManual_JP_R1-1-0.doc

Microsoft Word - ShareFastClientManual_JP_R1-1-0.doc ShareFast クライアントユーザマニュアル Stable Release 1.1 東京大学大学院工学系研究科環境海洋工学専攻稗方和夫 Mail: hiekata@nakl.t.u-tokyo.ac.jp 2 更新履歴 バージョン 更新日 更新内容 * 更新者 1.0.0 7/26/2006 - 書類を作成 ピルンロジャナカモンサン 1.0.1 7/31/2006 - インストールの詳細情報を追加

More information

SAMBA Stunnel(Mac) 編 1. インストール 1 セキュア SAMBA の URL にアクセスし ログインを行います xxxxx 部分は会社様によって異なります xxxxx 2 Mac OS 版ダウンロー

SAMBA Stunnel(Mac) 編 1. インストール 1 セキュア SAMBA の URL にアクセスし ログインを行います   xxxxx 部分は会社様によって異なります xxxxx 2 Mac OS 版ダウンロー 操作ガイド Ver.2.3 目次 1. インストール... - 2-2. SAMBA Stunnel 利用... - 5-2.1. 接続確認... - 5-2.2. 編集... - 9-2.3. インポート... - 12-2.4. 削除... - 14-3. 動作環境... - 15-4. 参考資料 ( 接続状況が不安定な場合の対処方法について )... - 16-4.1. サービスの再起動...

More information

Maser - User Operation Manual

Maser - User Operation Manual Maser 3 Cell Innovation User Operation Manual 2013.4.1 1 目次 1. はじめに... 3 1.1. 推奨動作環境... 3 2. データの登録... 4 2.1. プロジェクトの作成... 4 2.2. Projectへのデータのアップロード... 8 2.2.1. HTTPSでのアップロード... 8 2.2.2. SFTPでのアップロード...

More information

intra-mart e-Builder ver 5

intra-mart e-Builder ver 5 e-builder ver 5.0.0 インストールガイド Page 1 ================================================================== 名称 e-builder version 5.0.0 制作者名 NTTDATA INTRAMART Corp. 動作環境 Page Producer (Windows2000, Xp) Framework

More information

Calpont InfiniDBマルチUM同期ガイド

Calpont InfiniDBマルチUM同期ガイド Calpont InfiniDB マルチ UM 同期ガイド Release 3.5.1 Document Version 3.5.1-1 December 2012 2801 Network Blvd., Suite 220 : Frisco, Texas 75034 : 972.999.1355 info@calpont.com : www.calpont.com Copyright 2012 Calpont

More information

改訂履歴 初版 2004 年 1 月 23 日 新規作成 2 版 2004 年 2 月 3 日 フォントの設定 を追加 3 版 2004 年 7 月 13 日 リソースファイルのダウンロード を追加 バージョン番号表記を変更 4 版 2005 年 11 月 21 日 リソースファイルのダウンロード

改訂履歴 初版 2004 年 1 月 23 日 新規作成 2 版 2004 年 2 月 3 日 フォントの設定 を追加 3 版 2004 年 7 月 13 日 リソースファイルのダウンロード を追加 バージョン番号表記を変更 4 版 2005 年 11 月 21 日 リソースファイルのダウンロード Java インストール手順書 第 8 版 ( 社 ) 日本医師会 ORCA Project - 1 - Copyright(C)2009 Japan Medical Association.All rights reserved. 改訂履歴 初版 2004 年 1 月 23 日 新規作成 2 版 2004 年 2 月 3 日 フォントの設定 を追加 3 版 2004 年 7 月 13 日 リソースファイルのダウンロード

More information

CLUSTERPRO MC StorageSaver for BootDisk 2.1 (for Windows) インストールガイド 2016(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール

CLUSTERPRO MC StorageSaver for BootDisk 2.1 (for Windows) インストールガイド 2016(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール CLUSTERPRO MC StorageSaver for BootDisk 2.1 (for Windows) インストールガイド 2016(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール 改版履歴 版数 改版 内容 1.0 2015.3 新規作成 2.0 2016.3 バージョンアップに伴い改版 i はしがき

More information

ServerViewのWebアクセス制限方法

ServerViewのWebアクセス制限方法 [ 重要 ]ServerView のセキュリティ 1. 説明 ServerView コンソール (ServerView 管理コンソール ServerView WebExtension ServerView S2 Serverview AlarmService) の扱う情報の中には 管理者名等の個人情報や その他の重要情報が含まれています 外部からアクセスできるドメインに設置する装置には ServerView

More information

DHCPサーバのクラスタ化

DHCPサーバのクラスタ化 DHCP サーバのクラスタ化 次 DHCP サーバのクラスタ化 概要 この文書は CLUSTERPRO for Linux による DHCP サーバのクラスタ化に関する情報を載せています 目次 1 はじめに 1.1 改版履歴 1.2 免責事項 1.3 商標 2 構築手順 2.1 構築環境 2.2 事前準備 2.3 DHCP サーバの設定 2.4 クラスタ構成情報の作成 2.5 クラスタ構成情報の適用

More information

CLUSTERPRO MC StorageSaver for BootDisk 1.2 (for Windows) インストールガイド 2014(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール

CLUSTERPRO MC StorageSaver for BootDisk 1.2 (for Windows) インストールガイド 2014(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール CLUSTERPRO MC StorageSaver for BootDisk 1.2 (for Windows) インストールガイド 2014(Mar) NEC Corporation はじめに 製品導入の事前準備 本製品のインストール 本製品の初期設定 本製品のアンインストール 改版履歴 版数改版内容 1.0 2014.3 新規作成 i はしがき 本書は CLUSTERPRO MC StorageSaver