カロリメータ.indd



Similar documents
Protecting the global environment for the 21st century REFRIGERANT VAPOR FLOWMETER METHOD Satake Compressor Calorimeter 2

MRI | 所報 | 分権経営の進展下におけるグループ・マネジメント


Table 1. Assumed performance of a water electrol ysis plant. Fig. 1. Structure of a proposed power generation system utilizing waste heat from factori

<95DB8C9288E397C389C88A E696E6462>

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STW Symbol Symbol otary switch) 05 otary switch Symbol angle of notch 181

パナソニック技報

Fig, 1. Waveform of the short-circuit current peculiar to a metal. Fig. 2. Waveform of arc short-circuit current. 398 T. IEE Japan, Vol. 113-B, No. 4,

(2) IPP Independent Power Producers IPP 1995 NCC(New Common Carrier NCC NTT NTT NCC NTT NTT IPP 2. IPP (3) [1] [2] IPP [2] IPP IPP [1] [2]

On the Wireless Beam of Short Electric Waves. (VII) (A New Electric Wave Projector.) By S. UDA, Member (Tohoku Imperial University.) Abstract. A new e

alternating current component and two transient components. Both transient components are direct currents at starting of the motor and are sinusoidal

Huawei G6-L22 QSG-V100R001_02

植物23巻2号

JOURNAL OF THE JAPANESE ASSOCIATION FOR PETROLEUM TECHNOLOGY VOL. 66, NO. 6 (Nov., 2001) (Received August 10, 2001; accepted November 9, 2001) Alterna

untitled

ユーザーズマニュアル

_’¼Œì

LC304_manual.ai

SPSS

EQUIVALENT TRANSFORMATION TECHNIQUE FOR ISLANDING DETECTION METHODS OF SYNCHRONOUS GENERATOR -REACTIVE POWER PERTURBATION METHODS USING AVR OR SVC- Ju

A Nutritional Study of Anemia in Pregnancy Hematologic Characteristics in Pregnancy (Part 1) Keizo Shiraki, Fumiko Hisaoka Department of Nutrition, Sc

Introduction ur company has just started service to cut out sugar chains from protein and supply them to users by utilizing the handling technology of


10-渡部芳栄.indd

Tsuken Technical Information 1

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

NO



Ł\”ƒ_−mflF

Tab 5, 11 Tab 4, 10, Tab 3, 9, 15Tab 2, 8, 14 Tab 1, 7, 13 2

4.1 % 7.5 %

2 10 The Bulletin of Meiji University of Integrative Medicine 1,2 II 1 Web PubMed elbow pain baseball elbow little leaguer s elbow acupun



Corrections of the Results of Airborne Monitoring Surveys by MEXT and Ibaraki Prefecture

揃 Lag [hour] Lag [day] 35

ユーザーズマニュアル

7,, i

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T box number basic type Standard Specification Material of Enclosure Material of F

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility Fro

perature was about 2.5 Ž higher than that of the control irrespective of wind speed. With increasing wind speeds of more than 1m/s, the leaf temperatu


24_ChenGuang_final.indd

製品を支える先端環境技術

Fig. 3 Flow diagram of image processing. Black rectangle in the photo indicates the processing area (128 x 32 pixels).

特-2.indd

00_1512_SLIMLINE_BOOK.indb

untitled

49148

06_学術.indd


Continuous Cooling Transformation Diagrams for Welding of Mn-Si Type 2H Steels. Harujiro Sekiguchi and Michio Inagaki Synopsis: The authors performed

: , , % ,299 9, , % ,


IPSJ SIG Technical Report Vol.2014-EIP-63 No /2/21 1,a) Wi-Fi Probe Request MAC MAC Probe Request MAC A dynamic ads control based on tra

When creating an interactive case scenario of a problem that may occur in the educational field, it becomes especially difficult to assume a clear obj

内容見本_2012_1.indd

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

_Y05…X…`…‘…“†[…h…•


特-11.indd

Journal of Geography 116 (6) Configuration of Rapid Digital Mapping System Using Tablet PC and its Application to Obtaining Ground Truth

*Ł\”ƒ‚ä(DCH800)

WE WESB WENB WESNB 428

1 Fig. 1 Extraction of motion,.,,, 4,,, 3., 1, 2. 2.,. CHLAC,. 2.1,. (256 ).,., CHLAC. CHLAC, HLAC. 2.3 (HLAC ) r,.,. HLAC. N. 2 HLAC Fig. 2


16.16%


7 success of the creation of Soccer town in Urawa is mainly due to strong recognition and identity by local people as the Soccer town in Urawa distric

(2003)

A5 PDF.pwd

評論・社会科学 98号(P)☆/1.鰺坂

p _08森.qxd

千葉県における温泉地の地域的展開

indd

speax45CL/CLW

「フェリー等によるタンク自動車等の輸送に係る調査」における

untitled

speaxJ226YCL

26

MIDI_IO.book

A5 PDF.pwd

自分の天職をつかめ

パナソニック技報

クイックスタートガイド [SC-06D]

_™J„û

<30372D985F95B62D8E52967B8C4F8E7190E690B62E706466>

,

2 3

[2] , [3] 2. 2 [4] 2. 3 BABOK BABOK(Business Analysis Body of Knowledge) BABOK IIBA(International Institute of Business Analysis) BABOK 7

speax55CL 4版


06’ÓŠ¹/ŒØŒì

DPA,, ShareLog 3) 4) 2.2 Strino Strino STRain-based user Interface with tacticle of elastic Natural ObjectsStrino 1 Strino ) PC Log-Log (2007 6)

在日外国人高齢者福祉給付金制度の創設とその課題

橡最終原稿.PDF

100 SDAM SDAM Windows2000/XP 4) SDAM TIN ESDA K G G GWR SDAM GUI

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

Contents Launching of the Thailand-Japan Longstay Promotion Association Longstay and establishing the Thailand-Japan Longstay Promotion Association Re

Transcription:

REFRIGERANT VAPOR FLOWMETER METHOD Satake Compressor Calorimeter Patent Pending Taking compressor calorimeters to the next stage

Protecting the global environment for the 21st century REFRIGERANT VAPOR FLOWMETER METHOD Satake Compressor Calorimeter 2

Advancing to a new level Today, prevention of ozone layer destruction and a problem of global warming caused by combustion waste gas are being widely discussed globally and, in line with this trend, further restricted use of freon and waste gas is demanded as an immediate and critical issue. Nonetheless, air conditioners and refrigerators which satisfy our desires for a comfortable life style have already become essential in our homes as well as industry-wide, and research and development into energy conservation and increased efficiency of these products should be an endless task. Satake has developed and employed compressor calorimeters (CALOACE 21) using the refrigerant vapor flowmeter method, taking the lead in this field, replacing calorimeters of the secondary fluid type, in an attempt to support research and development aimed at achieving greater energy conservation, increased efficiency and promoting global environment protection. Satake s calorimeters are backed by a wealth of technological achievements which are renowned and recognized worldwide. Using Satake s calorimeters to make actual performance and capacity measurements of your compressors, will result in achieving of your research and development goals and fully satisfying your requirements. 3

The future of the calorimeter is now! Satake compressor calorimeter (CALOACE 21) Briefly, the refrigerant vapor flowmeter method is designed to test the refrigerating capacities of various types of independent compressors employed in package air conditioners, room air conditioners, automotive air conditioners, refrigerators, etc., by measuring the rate at which discharged refrigerant vapor flows through the circuits. Although there are several measurement methods, the evaporator calorimeter method (secondary fluid calorimeter method) and the refrigerant liquid flowmeter method have been widely employed so far. Satake leads the field in Japan in developing and employing compressor calorimeters using the refrigerant vapor flowmeter method. In due consideration of environmental protection, the CALOACE 21 does not use freon gas, which is necessary in the case of the secondary fluid calorimeter method. The CALOACE 21 is an compressor calorimeter which uses the latest method to achieve greater energy conservation and more reliable reproducibility. Flowchart of the CALOACE 21 A compressor calorimeter using the refrigerant vapor flowmeter method is designed to test the refrigerating capacities of compressors by measuring the rate at which discharged refrigerant vapor flows through the circuits (according to JIS B 8606 test methods for refrigeration purpose compressors). Use of secondary fluid is not required, and the amount of refrigerant passing through the circuit is reduced to approximately 40% of that in conventional types. Oil separator T Evaporator heat exchanger 6 5 Liquid receiver Condenser heat exchanger 3 4 Small quantities of discharged oil and refrigerant vapor are separated by the oil separator. Separated oil is returned to the specimen air compressor. (Please refer to page 7 for the related matters.) 1 Refrigerant vapor flowmeter Cooling water Refrigerant vapor passes through the refrigerant vapor flowmeter. The flow of refrigerant vapor at that time is measured with the flowmeter. 2 About one-fifth of the discharged refrigerant vapor flows into the condenser heat exchanger, where it is chilled and liquefied. T P T P The remaining discharged refrigerant vapor passes through the bypass line and is fed directly into the heat exchanger. Specimen air compressor They are then combined in the evaporator heat exchanger before being returned to the specimen air compressor. 4

All calorimeters are not created equal Features The CALOACE 21 is applicable to any refrigerant type of specimen air compressor. When compared with Compressor calorimeters employing the secondary fluid calorimeter method 1. Since a heater is no longer necessary in the evaporator heat exchanger, greater energy conservation is realized. 2. As the CALOACE 21 does not use a supercooling heat exchanger, a heater is no longer necessary, thus contributing to greater energy conservation. 3. The refrigerant vapor flowmeter method employs a bypassing type condensing system. Therefore, the refrigeration circuit can be made shorter and the amount of refrigerant passing through it is cut to less than 40% of conventional types. 4. Since the refrigerant vapor flowmeter method employs a bypassing type condensing system and as the capacity of the condenser heat exchanger is also smaller, the refrigerator can be made more compact, thus significantly reducing the electric power consumption of the water tank heater. 5. Thanks to downsizing of both the water tank and the refrigerator, they can now be built into system equipment. Compared with conventional compressor calorimeters, equipment weight has also been reduced and the required installation space decreased to almost 1/2 that of conventional compressor calorimeters. 6. The time required to stabilize the refrigeration cycles has been shortened by 1/2 to 1/3 (compared with that of our conventional equipment). 7. Thanks to all these advantages, not only energy conservation, but also the price has been greatly reduced compared with our secondary fluid type compressor calorimeters. We provide standard software developed by ourselves. Together they control everything from setting up and changing the test conditions, to determining the testing statuses, to collecting necessary data, and to judging stability through data printouts. (The reference values for judging stability and refrigeration capacity, and the integration time for the refrigeration capacity can all be modified.) The reproducibility of the CALOACE 21 is +/-0.5 to +/-1%. Standard refrigeration capacities available Available refrigeration capacities: 1.0kW to 5.0kW; 2.0kW to 12.0kW; 6.0kW to 20kW; and 20kW to 120kW The standard refrigeration capacity measurement range is 1kW to 120kW. Since no secondary fluid is used, the CALOACE 21 refrigerant vapor flowmeter type compressor calorimeter is friendly to the global environment. 5

Structural renovation of the calorimeter is taking place... Comparison of the refrigerant vapor flowmeter and secondary fluid calorimeter methods Evaporator heat exchanger Supercooling heat exchanger Refrigerator Water tank heater Amount of refrigerant used (in the case of the R-22) Installation space required for the system equipment (Cycle equipment) Refrigerant vapor flowmeter method Used (heater: not used) Not used Used (0.75 kw) Used (2kW) About 1.2 to 1.7kg Approximately 2m 2 (incorporating the water tank and refrigerator) Reduction in electric power consumption Secondary fluid calorimeter method Used (heater: 10kW) Used (heater: 1.2kW) Used (3.7kW) Used (18kW) About 2.5 to 3.0kg Approximately 3.22m 2 (incorporating the water tank) Approximately 0.6m 2 (separately installed refrigerator) CALOACE 21 flow sheet display Conditional set point display Running data display Judging stability condition display Data files display (result of test) 6

A decisive factor is the wealth of experience and achievements grained The discharged oil rate measurement is possible 7

Osaka Office 2-18-8, Toko-cho Moriguchi-shi, Osaka 570-0035, Japan and Plant: Phone (06)6992-0371 Fax (06)6998-4947 Tokyo Office 66, Niizo, Toda-shi, Saitama 335-0021, Japan and Plant: Phone (048)433-8711 Fax (048)433-8541 Chubu Sales Iseyama Bldg., 1-1-1, Iseyama, Naka-ku, Nagoya-shi, Aichi 460-0026, Japan Service Center: Phone (052)331-6691 Fax (052)331-2162 Mixing Technology 227-1, Niizo, Toda-shi, Saitama 335-0021, Japan Laboratory: Phone (048)441-9200 Fax (048)444-1042 Associates: Satake 5-52-11, Hoshida-Kita, Katano-shi, Osaka 576-0017, Japan Engineering Co., Ltd. Phone (072)892-1115 Fax (072)892-4546 201204 108 Tel. 86-21-5843-4466 Fax. 86-21-6892-1472 36068171 2 88 38 Tel. 886-2-2995-3173 Fax. 886-2-2995-6436 (Overseas affiliated companies) China Shanghai Satake Cool-Heat & Control Technique Co., Ltd. No.108 BeiCai Chenchun Rd., Pudong New Area, Shanghai 201204, China Tel: 86-21-5843-4466 Fax: 86-21-6892-1472 Taiwan Chuyi System Co., Ltd. No.38, Lane 88, Sec.2, Kuang Fu Rd., Sanchung City, Taipei 36068171, Taiwan Tel: 886-2-2995-3173 Fax: 886-2-2995-6436