Adaptec SCSI RAID 2120S Controller QUick Install Guide

Similar documents
Diskette Drive Installation

Diskette Drive Installation

ドライバインストールガイド

HP User Manual for the Integrated Intel SATA RAID Controller for Microsoft Windows XP Professional and Windows 2000 Profess...

HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル

PCI Express Graphics Products

NSR-500 Installation Guide

NSR-500 Create DVD Installer Procedures

Microsoft Word - Win-Outlook.docx

Actual ESS Adapterの使用について

HA8000-bdシリーズ RAID設定ガイド HA8000-bd/BD10X2

fx-9860G Manager PLUS_J

Microsoft Word - KUINS-Air_W10_ docx

Microsoft Word - PrivateAccess_UM.docx

Microsoft Word - 3Ware_RaidManual.doc

ソフトウェアの更新ユーザーガイド

Introduction Purpose This training course demonstrates the use of the High-performance Embedded Workshop (HEW), a key tool for developing software for

プレインストールOSリカバリ手順書

FTDI Driver Error and Recovery Procedure Check FTDI driver operation Rev :OK, Rev :NG, Rev :NG May 11, 2017 CHECK FTDI DRIVER

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA B. BIOS SATA ( 1) C. RAID BIOS RAID D. SATA RAID/AHCI 2 SATA M.2 SSD ( 2) ( (

Z200/Z200SFF WinXP 64bit マニュアルインストール手順書

Microsoft Windows XP Professional x64 Editionインストール方法説明書

セットアップユーティリティユーザガイド

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

発行 20XX年XX月XX日

発行 20XX年XX月XX日

Z400/Z600 WinXP 64bitマニュアルインストール手順(SATA)ver2

Microsoft Word - KUINS-Air_W8.1_ docx

発行 20XX年XX月XX日

NSR-500 Create USB Installer Procedures

P3FY-A JP.PDF

Z800 WinXP 64bitマニュアルインストール手順(SATA)ver2

Promise FastTrak100 Japanese Manual

Microsoft Word - DWR-S01D_Updater_取扱説明書_120514A.doc

Internet Explorer 1. Under the Tools or Settings icon in the toolbar, click on Internet Options 2. Ensure Delete browsing history on exit box is unche

Z400/Z600 WinXP 64bitマニュアルインストール手順(SAS)ver3

NSR-500 Software Update Installation Procedures

2 3

PRIMEQUEST 1000 シリーズ IO 製品 版数の確認方法

AMT機能セットアップガイド

Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. Windows は米国 Microsoft Corporation の米国およびその他の国における登録商標です 本書の内容は 将来予告なしに変更されることがあります HP 製

1 138

N manual_JP.PDF

橡P3FY-A015-01_A.PDF

RAID RAID 0 RAID 1 RAID 5 RAID * ( -1) * ( /2) * RAID A. SATA SSD B. BIOS SATA ( 1) C. RAID BIOS RAID D. RAID/AHCI 2 SATA SSD ( 1) ( ( 3) 2

BGI PDF

Red Hat Enterprise Linux ES (v. 3)

HP StorageWorks 9000–series Virtual Library System User Guide (抜粋)

HP ThinUpdateを使用したWESシンクライアントイメージリストア手順書

Creative Sound Blaster Audigy 2 ZS

untitled

Z420-Z620 WinXP 32bit SATA マニュアルインストール手順書

Microsoft Word - README_2011_FW.txt

Adaptec SCSI 29320LPE QSG.fm

DWR-S01D Updater 取扱説明書 発行日 :2011/2/28

1 122

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

Z420-Z620 WinXP 64bit SATA マニュアルインストール手順書

ServerView with Data ONTAP-v™ PowerChute® Network Shutdown 設定について

US40cユーザーズガイド

Z220 WinXP 32bit SATA マニュアルインストール手順書

elemmay09.pub

インストールのチェックリストと前提条件

HP Server tc2120 Microsoft Windows 2000 Server SP3 HP P

Adaptec RAID Controller Installation and User’s Guide

Windows XP で使用する 既に Windows XP がインストールされているパソコンで 本 PC カードを使用するための方法 ( サポートソフトをインストールする ) を説明します 1 度セットアップを行えば 今後は本 PC カードを接続するだけで使えるようになります 手順 ステップ 1.

他のOSをお使いになる方へ

Microsoft Word - eRecovery v3-1.doc

IRsolution インストール手順書 修正箇所

LC304_manual.ai

untitled

Cisco MXE のリカバリ

UR28M/UR824/UR44/UR12/UR22mkII Firm UG

Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. Windows は米国 Microsoft Corporation の米国およびその他の国における登録商標です 本書の内容は 将来予告なしに変更されることがあります HP 製

TOOLS for UR44 Release Notes for Windows

How to Use In-flight Wi-Fi service ご利用ガイド 3 Flight Plan will be available for international connecting flights within 24 hours. 3 フライトプランは24時間以内であれば 国際

4 How to Print Cards When you want to print Select the cards you would like to print from your WORD LIST. About the WORD LIST To print multiple cards,

Fast!UTIL が起動すると 以下のメニューが表示されます Configuration Settings Scan Fibre Devices Fibre Disk Utility Loopback Data Test Select Host Adapter Exit Fast!UTIL Con

[DS50-N A] BIOS マニュアル BIOS セットアップユーティリティとは BIOS セットアップユーティリティとは BIOS の設定を確認 変更するためのツールです セットアップユーティリティは 本体に内蔵されているマザーボード上のフラッシュメモリーに格納されています このユ

OUTSIDE FRONT COVER Setup Guide セットアップ ガイド C M Y K PMS 3005

現象 2 仮想マシン起動時に イベントログ ( システムログ ) に次のエラーイベントが記録される イベントログ内容種類 : エラーソース :storvsp イベント ID:5 Cannot load storage device in ' 任意の仮想マシン名 ' because the versi

1 142

Dell System Services and Diagnostic Tools Version 7.0 クイックインストールガイド

Windows Server 2003 のインストール

Z220 WinXP 64bit SATA マニュアルインストール手順書

入学検定料支払方法の案内 1. 入学検定料支払い用ページにアクセス ポータルの入学検定料支払いフォームから 入学検定料支払い用 URL の ここをクリック / Click here をクリックしてください クリックを行うと 入学検定料支払い用のページが新たに開かれます ( 検定料支払い用ページは ポ

目次 本書の取り扱いについて... 3 事前準備... 4 MultiPoint Server 2011 OEM 版のインストール (OS リカバリー用のディスク領域を使う場合の起動方法 )... 5 MultiPoint Server 2011 OEM 版のインストール (OS リカバリー用のメデ

UR28MUR824UR44UR22mkII Firmware Update Guide

2

Rev.2 N 内蔵 RDX N 外付 RDX ファームウェアアップデート手順 RDX 装置をお買い上げいただきましてありがとうございます 本書は N 内蔵 RDX N 外付 RDX のファームウェアアップデート手順を記載しています 1. 概要

DWT-B01 Updater 取扱説明書 発行日 :2011/3/23

Contents Logging in 3-14 Downloading files from e-ijlp 15 Submitting files on e-ijlp Sending messages to instructors Setting up automatic

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

Introduction Purpose This course explains how to use Mapview, a utility program for the Highperformance Embedded Workshop (HEW) development environmen

2

Creative Sound Blaster Audigy 2 ZS クイック スタート ガイド

Steinberg AXR4T Firmware Update Guide

WinBook WV BIOS セットアップ マニュアル BIOS セットアッププログラムについて BIOS セットアッププログラムとはパソコンの BIOS 設定を確認 変更するためのプログラムです 本機では AMI BIOS を使用しています セットアッププログラムは マザーボード上のフラッシュメ

Z820 WinXP 64bit SATA マニュアルインストール手順書

Transcription:

Quick Install Guide Adaptec SCSI RAID 2120S Controller The Adaptec SCSI Raid (ASR) 2120S Controller is supported on the HP Workstation xw series with Microsoft Windows 2000 and Windows XP operating systems only. If you have a workstation with an operating system that is not listed here, check the HP support website at www.hp.com/go/workstationsupport for a systems supported list. This site always has the latest product support information and drivers. NOTE: This guide is intended for those who have some background knowledge or experience with computer hardware and software installation. HP recommends you use the same capacity and type of drives on your workstation as the RAID array you are be creating. For example, if you use 36GB, U320 SCSI, 10K RPM hard drives, all drives should be the same type. More information about RAID and other installation options can be found on the Management Software, Drivers & Documentation CD. This guide covers the following two cases: Case 1 Installing the operating system on the disk array connected to the controller Case 2 Creating a single data array on an existing system Case 1: Installing the Operating System on the Disk Array Connected to the Controller This process reinstalls the operating system to a factory ship condition and could take up to a few hours to complete depending on the speed of your system. Follow the steps below in the order that they are presented: IMPORTANT: All of the following steps must be completed in the order shown below for successful installation of your system. 1. Pre-Installation Preparation 2. Hardware Installation 3. Configuring the RAID array 4. System Restore Process 5. Updating the Driver 6. Window Management Software Installation (Optional)

Case 2: Creating a Single Data Array on an Existing System NOTE: The operating system must be on a separate controller. This option is an easier and shorter process, but your operating system will not be on the RAID array. For this option you might need to order an additional SCSI cable from HP. Follow the steps below in the order they are presented: 1. Pre-Installation Preparation 2. Hardware Installation 3. Configuring the RAID array 4. Updating the driver 5. Window Management Software Installation (Optional) Pre-installation Preparation Be sure your workstation has the latest system BIOS installed. Check the HP support website at www.hp.com/go/workstationsupport. If your system does not have the latest system BIOS, download and upgrade it using the instructions posted on the support website before installing the ASR 2120S adapter. HP recommends you download the latest ASR 2120S driver posted on the HP support website at www.hp.com/go/workstationsupport and create a driver diskette. NOTE: Write down the driver version number, you need it later in this procedure. A driver diskette can also be created by inserting the Management Software, Drivers & Documentation CD into a production system running a Windows OS. 1. In the ADAPTEC Storage Manager window, click Create Driver Disk. 2. On the Command window, press the appropriate number for the operating system you are installing. 3. Insert a blank 3.5-inch diskette into the diskette drive (drive A). 4. Press A in the command window. 5. When the Please select a format option: [F, Q, S]? window appears, press Q. 6. When the message Diskette successfully created is displayed, close the command window by clicking the X at the top-right corner of the window. NOTE: For the best performance, HP recommends that you check the HP support website for the latest drivers and updates. 7. Locate the System Restore CD set that came with your workstation. Check the date printed on the Restore CD and make sure the date is March 2003 or newer. IMPORTANT: If you have a Restore CD set with an older date, you cannot continue. Contact HP support to request a new CD set. 8. Be sure you have a SCSI cable that can accommodate the number of hard drives you want to install in the workstation. Additional SCSI cables can be ordered from HP. Hardware Installation 1. Back up the data on the workstation where you are installing the RAID array. CAUTION: The following steps deletes all data and information on the hard drive where you are creating the RAID array. 2. Shut down the workstation and disconnect the main power cord from the rear of the workstation and from the electrical wall outlet.

3. Open the chassis cover of the workstation. 4. (Case 1 only) Disconnect the SCSI connector on the controller end if your workstation has SCSI hard drives. 5. Install the ASR 2120S adapter in one of the available PCI slots in your workstation. NOTE: Your workstation might have 32-bit PCI or 64-bit PCI slots. It is recommended that you install the ASR 2120S adapter in the 64-bit PCI slot to take advantage of the bus performance, but the adapter can also be installed in a 32-bit PCI slot if your workstation does not have a 64-bit PCI slot. 6. Set the SCSI IDs for each hard drive using the jumper setting on the hard drive label. Each drive MUST have a unique ID or the workstation does not boot. 7. Connect the hard drives to the RAID controller using the SCSI cable. 8. Connect the power cable to each drive. 9. Close the chassis cover. 10. Reconnect the main power cord to rear of the workstation and to the electrical wall outlet. Configuring the RAID Array 1. Turn on the workstation and when you see the HP logo screen, press the Esc key to see the Option ROM Message. NOTE: If you do not see the Option ROM message mentioned in the next step, go into your system BIOS Setup and enable the Option ROM Scan setting. (Follow the on-screen instructions or refer to your system user manual for reference). Save the system configuration and exit. The system reboots. 2. (Case 1 only) Your system might come with an IDE drive or other SCSI controller. To boot from the RAID array you might need to set up the boot device priority so that Bootable Add in Card is set as the boot device (as opposed to the IDE drives) or the Adaptec RAID Controller is listed at the top under Controller Order. Save the configuration changes and exit the setup. The system reboots. NOTE: The BIOS settings might differ depending on your system model. Refer to your system manual for specific BIOS instructions. 3. When you see the option ROM message, Adaptec SCSI RAID BIOS Vx.xx [BUILD xxxx] and <<<Press <Ctrl> <A> for Adaptec RAID Configuration Utility, hold down the Ctrl key then press A to go into the RAID configuration utility. 4. In the menu, press Enter to select the Array Configuration Utility that is highlighted by default. 5. In the menu, use the arrow keys to navigate to Initialize Drives then press Enter. NOTE: All drives used to create the boot array must be initialized. CAUTION: Initializing a drive destroys any existing data. 6. Use the arrow keys to navigate and press the Insert key to select the drives for initialization. 7. When you see the following red warning message Warning! Initialization will erase all Array Information from selected drives. Any Array using any of these drives, as members will be affected. Do you want to continue?, press Y to continue. The system initializes the selected drives. 8. After initializing the drives, the main menu is displayed. Select Create Array by highlighting the item and pressing Enter. 9. Select the drives that you wish to create the array on by highlighting them and pressing the Insert key. Repeat this step until all the drives to be used are selected. When all the desired drives are on the right side, press Enter to continue. 10. On the next screen, make the following selections and entries:

Property Line Displayed Array Type Array Label Array Size Stripe Size Read Caching Write Caching Create RAID via [Done] Entry of Selection Select the RAID type you want, press Enter. Type a suitable name in the space provided, press Enter. Press Enter to use the default drive granularity of GB. Press Enter. Press Enter. Press Enter. Press Enter. Press Enter. NOTE: The RAID type depends on the number of drives available on your system. RAID-0 requires two or more drives. RAID-1 requires two drives, RAID-5 requires three or more drives, and RAID-10 requires four or more even number of drives. 11. When the Creating Array window appears, press Enter to continue with the array configuration. NOTE: The array is available immediately, but continues to build until finished, impacting performance until it is done. 12. Press the Esc key until the Exit Utility window is displayed. Highlight Yes, then press Enter to reboot the system. System Restore Process (Case 1 Only) 1. Insert the first Restore CD that came with your system into the CD-ROM drive. 2. Choose the Language and type of operating system for your system and follow the on-screen instructions to finish the system restore process. NOTE: During this process the system reboots a couple times and might ask for the Operating System CD and other supplemental CDs. This process could take up to a few hours. 3. When the Microsoft Windows Welcome screen is displayed, you have successfully completed the restore process. Updating the Driver (Case 1 Only) 1. Check the driver version using the following steps: a. Right-click My Computer (for Windows XP, My Computer is in the Start menu.) b. Click Manage from the pop up menu. c. Click Device Manager under System Tools in the left window. d. In the right window, click the + sign beside the SCSI and RAID controllers. e. In the sub item, right-click Adaptec SCSI RAID 2120S Controller and click Properties. f. Select the Driver tab in the pop up window. g. Note the driver version and date listed. 2. Compare the driver version with the one you wrote down from the support website earlier. If they are the same, no action is required. However, if the driver on your system is older than the driver posted on the HP website, download and install the new driver now, using the instructions posted on the website.

3. After updating the driver, you are ready to restore your backup data. Installing the Driver (Case 2 Only) 1. After you install the RAID card and boot to Windows 2000 or Windows XP for the first time, the Welcome to the Found New Hardware Wizard window is displayed. 2. Insert the driver diskette that you created earlier in the Pre-Installation Preparation step. 3. Click Next and follow the on-screen instructions to finish the installation. Installing the Windows Management Software (Optional) The Storage Manager Browser Edition utility is included on the CD that came with the RAID adapter. To install the utility: 1. Insert the CD into the CD-ROM drive and the ADAPTEC Storage Manager Browser Edition window is displayed. 2. Click Install Adaptec Storage Manager Browser Edition and follow the on-screen instructions. Your system needs to reboot before you can use the utility. NOTE: Eject and remove the CD before you reboot the system. For details on how to use the tool, click View Documentation on the ADAPTEC Storage Manager Browser Edition window and click Adaptec Advance RAID Software User's Guide.

325581-002 2004 Hewlett-Packard Development Company, L.P. The HP Invent logo is a registered trademark of Hewlett-Packard Development Company, L.P. Microsoft and Windows are trademarks of Microsoft Corporation in the U.S. and other countries.

クイックインストールガイド Adaptec SCSI RAID 2120S コントローラ Adaptec SCSI RAID (ASR) 2120S コントローラは Microsoft Windows 2000 および Windows XP オペレーティングシステムで稼動する HP ワークステーション xw シリーズでサポートされています これ以外のオペレーシングシステムで稼動するワークステーションの場合は HP サポート Web サイト www.hp.com/go/workstationsupport ( 英語 ) で サポートされているシステムを確認してください このサイトには 常に最新の製品サポート情報とドライバが掲載されています 注記 : 本書では コンピュータのハードウェアおよびソフトウェアのインストールの知識と経験のある方を対象としています HP は お客様が構築する RAID アレイと同じ容量 同じ種類のディスクドライブをワークステーションにお使いになることをお勧めします 例えば 36GB U320 SCSI 10K RPM のディスクドライブを使用している場合 すべてのディスクドライブを同じ種類のものにしてください RAID およびその他のインストールオプションについての詳細は Management Software, Drivers & Documentation CD に収録されています 本書では 以下の 2 つのケースについて説明します ケース 1 : コントローラに接続されたディスクアレイにオペレーティングシステムをインストールする ケース 2 : 既存のシステムにシングルデータアレイを作成する ケース 1: コントローラに接続されたディスクアレイにオペレーティングシステムをインストールする この作業は オペレーティングシステムを再インストールして出荷時の状態に戻します お使いのシステムの速度によっては数時間かかる場合があります 以下の手順を記載されている順番に実行してください 重要 : お使いのシステムのインストールを成功させるには 以下の手順を記載されている順番に完了しなければなりません 1. インストールの準備 2. ハードウェアのインストール 3. RAID アレイの構成 4. システムリストアプロセス 5. ドライバの更新 6. Windows 管理ソフトウェアのインストール ( オプション )

ケース 2: 既存のシステムにシングルデータアレイを作成する 注記 : オペレーティングシステムは 別のコントローラにインストールされていなければなりません この方法は 簡単かつ短時間のプロセスですが お使いのオペレーティングシステムは RAID アレイ上にはありません この方法の場合 HP に追加の SCSI ケーブルを注文する必要があります 以下の手順を記載されている順番に実行してください 1. インストールの準備 2. ハードウェアのインストール 3. RAID アレイの構成 4. ドライバの更新 5. Windows 管理ソフトウェアのインストール ( オプション ) インストールの準備 お使いのワークステーションに 最新の BIOS がインストールされていることを確認します HP のサポート Web サイト www.hp.com/go/workstationsupport ( 英語 ) で確認してください お使いのシステムの BIOS が最新でない場合 ASR 2120S アダプタをインストールする前に 最新の BIOS をダウンロードし サポート Web サイトに掲載されている指示にしたがって BIOS を更新してください サポート Web サイト www.hp.com/go/workstationsupport ( 英語 ) に掲載されている最新の ASR 2120S のドライバをダウンロードし ドライバディスクを作成することをお勧めします 注記 : ドライバのバージョン番号をメモしておいてください 後の手順でバージョン番号が必要になります ドライバディスクは Windows オペレーティングシステムで本番稼動しているシステムに Management Software, Drivers & Documentation CD を挿入して作成することもできます 1. [ADAPTEC Storage Manager] ウィンドウで [Create Driver Disk] をクリックします 2. [Command] ウィンドウで インストールするオペレーティングシステムに該当する番号をクリックします 3. フロッピーディスクドライブ (A ドライブ ) に 空の3.5 インチフロッピーディスクを挿入します 4. コマンドウィンドウで [A] を押します 5. [Please select a format option: [F, Q, S]?] ウィンドウが表示されたら [Q] を押します 6. [Diskette successfully created] が表示されたら ウィンドウ右上の 閉じる ボタン ([X]) をクリックしてコマンドウィンドウを閉じます 注記 : パフォーマンスを高めるため HP サポート Web サイトで最新のドライバと更新を確認することをお勧めします 7. お使いのワークステーションに付属のシステムリストア CD セットを用意します リストア CD に印刷されている日付が 2003 年 3 月より新しいものであることを確認します 重要 : 2003 年 3 月より古い日付のリストア CD しかお持ちでない場合 作業は続けられません HP のサポート窓口に問い合わせて 新しい CD を入手してください 8. ワークステーションにインストールするハードディスクの数に対応する SCSI ケーブルがあることを確認します 追加の SCSI ケーブルは HP に注文してください

ハードウェアのインストール 1. RAID アレイをインストールするワークステーションのデータのバックアップを取ります 注意 : 以下の手順を実行すると RAID アレイを作成するハードディスクドライブのすべてのデータと情報が消去されます 2. ワークステーションをシャットダウンし メイン電源コードをワークステーションの背面から抜き 電源コンセントから抜きます 3. ワークステーションのシャーシカバーを開けます 4. ( ケース 1 の場合のみ ) ワークステーションに SCSI ハードドライブが接続されている場合 コントローラ側の SCSI コネクタを抜きます 5. ワークステーションの空いている PCI スロットに ASR 2120S アダプタを取り付けます 注記 : PCI スロットには 32 ビット PCI と 64 ビット PCI の 2 種類ある場合があります バス性能を高めるため ASR 2120S アダプタは 64 ビット PCI スロットに取り付けることをお勧めしますが 64 ビット PCI スロットがない場合は 32 ビット PCI スロットにインストールしてください 6. ハードドライブラベルのジャンパ設定を使って 各ハードドライブの SCSI ID を設定します 各ドライブには固有の ID を割り当てます そうでない場合 ワークステーションは起動しません 7. SCSI ケーブルで ハードドライブを RAID コントローラに接続します 8. 電源ケーブルを各ドライブに接続します 9. シャーシカバーを閉じます 10. メイン電源コードをワークステーションの背面に接続し 電源コンセントに差し込みます RAID アレイの構成 1. ワークステーションの電源を入れ HP ロゴ画面が表示されたら [Esc] キーを押し [Option ROM Message] を表示します 注記 : 次の手順で説明する [Option ROM] メッセージが表示されない場合 お使いのシステムの BIOS 設定で [Option ROM Scan] 設定を有効にしてください ( 画面に表示される指示に従うか お使いのシステムのユーザーマニュアルを参照してください ) システム設定を保存し 終了します システムが再起動します 2. ( ケース 1 の場合のみ ) IDE ドライブ もしくは 他の SCSI コントローラが お使いのシステムに接続されている場合があります RAID アレイから起動できるようにするには [Bootable Add in Card] が起動デバイス (IDE ドライブに対抗するもの ) として設定されるように起動デバイス優先順位を設定するか Adaptec RAID コントローラが [Controller Order] 一覧の一番上にくるようにする必要があります 設定の変更を保存し セットアップを終了します システムが再起動します 注記 : BIOS 設定は お使いのシステムによって異なります お使いの BIOS 特有の指示については システムマニュアルを参照してください 3. Option ROM メッセージ Adaptec SCSI RAID BIOS Vx.xx [BUILD xxxx] と <<<Press <Ctrl> <A> for Adaptec RAID Configuration Utility が表示されたら [Ctrl] キーを押したまま [A] を押し RAID 構成ユーティリティを起動します 4. メニューで [Enter] キーを押し デフォルトでハイライト表示されている [Array Configuration Utility] を選択します

5. メニューで 矢印キーを使って [Initialize Drives] まで移動し [Enter] キーを押します 注記 : 起動用に作成されたすべてのドライブは アレイ用に初期化しなければなりません 注意 : ドライブを初期化すると すべてのデータは消去されます 6. 初期化するドライブを矢印キーで探し [Insert] キーを押してそのドライブ ( 複数選択可能 ) を選択します 7. [Warning! Initialization will erase all Array Information from selected drives. Any Array using any of these drives, as members will be affected. Do you want to continue?] という赤字のメッセージが表示されたら [Y] を押して作業を続行します システムが 選択したドライブを初期化します 8. ドライブの初期化が終了すると メインメニューが表示されます [Create Array] をハイライト表示して選択し [Enter] キーを押します 9. アレイを作成するドライブを ハイライト表示して選択し [Insert] キーを押します 使用するドライブがすべて選択されるまで この手順を繰り返します 該当するすべてのドライブが右側にあるのを確認し [Enter] キーを押して作業を続行します 10. 次の画面で 以下の選択と入力を行います 表示されるプロパティ行 Array Type Array Label Array Size Stripe Size Read Caching Write Caching Create RAID via [Done] 選択の入力 希望する RAID の種類を選択し [Enter] キーを押します 表示されているフィールドに名前を入力し [Enter] キーを押します [Enter] キーを押し デフォルトの GB ドライブ単位で使用するアレイの初期化サイズを入力します [Enter] キーを押します [Enter] キーを押します [Enter] キーを押します [Enter] キーを押します [Enter] キーを押します 注記 : RAID の種類は お使いのシステムで利用可能なドライブの数によって異なります RAID-0 には 2 つ以上のドライブが必要です RAID-1 には 2 つのドライブ RAID-5 には 3 つ以上のドライブ RAID-10 には 4 つ以上の偶数台のドライブが必要となります 11. [Creating Array] ウィンドウが表示されたら [Enter] キーを押し アレイ構成作業を続けます 注記 : アレイは すぐに利用可能となりますが 構築作業を完了するまで続けてください この作業を完了しないと パフォーマンスに影響がでます 12. [Exit Utility] ウィンドウが表示されるまで [Esc] キーを押します [Yes] をハイライト表示させ [Enter] キーを押してシステムを再起動します リストアプロセス ( ケース 1 の場合のみ ) 1. お使いのシステムに付属のリストア CD の 1 枚目を CD-ROM ドライブに挿入します

2. お使いのシステムの [Language] と [type of operating system] を選択し 画面の指示に従ってリストアプロセスを完了します 注記 : この処理中に システムを数回再起動する場合があります その際に オペレーティングシステムの CD やその他の補足 CD が要求される場合があります この処理に数時間かかる場合があります 3. Microsoft Windows の ようこそ 画面が表示されると リストアプロセスは成功終了しています ドライバの更新 ( ケース 1 の場合のみ ) 1. 以下の手順で ドライバのバージョン番号を確認します a. [ マイコンピュータ ] を右クリックします (Windows XP の場合 [ マイコンピュータ ] は [ スタート ] メニューの中にあります ) b. ポップアップメニューで [ 管理 ] をクリックします c. 左側のウィンドウの [ システムツール ] の下の [ デバイスマネージャ ] をクリックします d. 右側のウィンドウで [SCSI と RAID コントローラ ] の隣の [+] マークをクリックします e. サブ項目の [Adaptec SCSI RAID 2120S Controller] を右クリックし [ プロパティ ] をクリックします f. ポップアップウィンドウで [ ドライバ ] タブを選択します g. ドライバのバージョンと日付をメモします 2. 前の手順でメモしたサポート Web サイトに掲載されていたドライバのバージョンと比較します 同じバージョン番号の場合は 処理は必要ありません お使いのシステムのドライバのバージョンが HP の Web サイトに掲載されていたバージョンより古い場合は 新しいドライバをダウンロードし Web に記載されている指示に従ってインストールしてください 3. ドライバの更新後 バックアップデータのリストアが可能となります ドライバのインストール ( ケース 2 の場合のみ ) 1. RAID カードをインストールした後 初めて Windows 2000 または Windows XP を起動すると [ 新しいハードウェアの検索ウィザードの開始 ] が表示されます 2. インストールの準備 で作成したドライバのフロッピーディスクを挿入します 3. [ 次へ ] をクリックし 画面に表示される指示に従ってインストールを完了します Windows 管理ソフトウェアのインストール ( オプション ) RAID アダプタに同梱されている CD に Storage Manager Browser Edition ユーティリティが収録されています インストールは以下の手順で行います 1. CD を CD-ROM ドライブに挿入すると [ADAPTEC Storage Manager Browser Edition] ウィンドウが表示されます 2. [Install Adaptec Storage Manager Brower Edition] をクリックし 画面に表示される指示に従います ユーティリティを使用する前に システムを再起動する必要があります 注記 : システムを再起動する前に CD を取り出しておいてください ツールの使用についての詳細は [ADAPTEC Storage Manager Browser Edition] ウィンドウで [View Documentation] をクリックし [Adaptec Advance RAID Software User's Guide] をクリックしてください

325581-002 2004 Hewlett-Packard Development Company, L.P. The HP Invent logo is a registered trademark of Hewlett-Packard Development Company, L.P. Microsoft および Windows は 米国およびその他の国における Microsoft Corporation の商標です