TB-2606 Terminal Block Installation Guide (Multilingual)

Similar documents
TB-2605 Isothermal Terminal Block Installation Guide (Multilingual)

NI TB-2630B 取り付け手順 - National Instruments

GMCT20 Cable Installation Instructions - National Instruments

Diskette Drive Installation

Diskette Drive Installation

NI SCXI-1335 Installation Instructions (Multilingual)

CAL-4353 キャリブレーション手順 - National Instruments

NI SCXI-1331 Installation Instructions (Multilingual)

Specification for Manual Pulse Generator, GFK-2262

2

NI 1357/1358/1359 SCXI Controller/Adapter Kit Installation Guide (Multilingual)


PCI Express Graphics Products

NI 6601/6602 キャリブレーション手順 - National Instruments

NI 651x 仕様 - National Instruments

H8000操作編

2

2



内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

2



untitled

NI 653X ケーブルアダプタユーザガイド - National Instruments




Microsoft Word - Win-Outlook.docx

19_22_26R9000操作編ブック.indb

BS・110度CSデジタルハイビジョンチューナー P-TU1000JS取扱説明書

M. 端子台 ( 脱落防止タイプ )/ M. Terminal Block(Screw Holding Type) スクリューホールド (SH) 端子台 / Screw Hold 意匠登録済み /Design Registered /Steel.0m/m :AC0V A :DC00V 0MΩ abo

Archived: LabVIEW Real-Timeモジュールリリースノートおよびアップグレードノート(日本語) - National Instruments

Z7000操作編_本文.indb

SBAL FA-R5F10JBCANA-RX ユーザーズ マニュアル B5D 1

fx-9860G Manager PLUS_J

00_1512_SLIMLINE_BOOK.indb

SonicWALL SSL-VPN 4000 導入ガイド

2

TOOLS for UR44 Release Notes for Windows

Tab 5, 11 Tab 4, 10, Tab 3, 9, 15Tab 2, 8, 14 Tab 1, 7, 13 2

MIDI_IO.book

62B2-J-0009e_ccc

MINAS取説アブソ警告クリア方法記載ミス_モータニュース…

080906_…o…−…^…b…vVSCW

elemmay09.pub

P3FY J E

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

AWS Client VPN - ユーザーガイド

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

0 C C C C C C C

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

Sliding Rack Mount Kit Installation

Connectors for Automobiles 62 SEALED SERIES Japanese English

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

32C2100操作編ブック.indb

Microsoft Word - ★(9215) 332_O.doc

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility Fro

- 1 -

NSR-500 Installation Guide



FA-78F0849GK-GAK-RX ユーザーズ・マニュアル


N PCIe SSD搭載キット 取り扱いの手引き

PowerPoint Presentation

323742RH500操作編.indb

Microsoft Word - PrivateAccess_UM.docx

NI PXI-2503 Specifications (Multilingual)

2 3

Creative Sound Blaster Audigy 2 ZS Quick Start Guide

Page 1 of 6 B (The World of Mathematics) November 20, 2006 Final Exam 2006 Division: ID#: Name: 1. p, q, r (Let p, q, r are propositions. ) (10pts) (a

0 C C C C C C

NSR-500 Create DVD Installer Procedures

untitled

FA-78F0138HDGK-8A8-RX ユーザーズ・マニュアル

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

PC_14ZY6_BFT150A_US_ indd

注意 Caution 1) AMT-KS を溶接ロボット等に取り付ける際には 必ず溶接機の電源を OFF にし 電気が流れていないことを確認した後 作業を行ってください Keep off of the welding power source during AMT-KS installation w

32_42H3000操作編ブック.indb

ZV500操作編_本文.indb

Archived: Installation Guide, NI for Windows Driver Software Archive (English and Japanese) - National Instruments

NI 9925屋外IP54ケース 取り付けガイド - National Instruments


橡P3FY-A015-01_A.PDF

VE-GP32DL_DW_ZA

1) 1) Props of preparation. Wire Scale Spike Cutter Hammer Tape Marker (, ) Rope(For Sezing) 2) 2) Marking A 22 A point Position of twenty-two times t

DDR3 SDRAMメモリ・インタフェースのレベリング手法の活用

_QSG_ENJA

M セットアップガイド / USB-to-Serial Adaptor Setup Guide USB/RS-485 通信変換ユニット :PBFM-U6 をご購入いただき, まことにありがとうございます 本書は通信変換機のセットアップ手順を記載しています なお,PCIF ソフトの使用方

ユーザーズマニュアル

細線同軸コネクタ 製品シリーズ

BNC-2110 取り付けガイド - National Instruments

*Ł\”ƒ‚ä(DCH800)

WE WESB WENB WESNB 428

Transcription:

INSTALLATION GUIDE TB-2606 Terminal Block Contents Introduction This installation guide describes how to install and connect signals to the TB-2606 terminal block for use with the NI 2501 and NI 2503 PXI switch cards. Introduction... 1 What You Need to Get Started... 2 Signal Names... 2 Signal Connection... 3 Installing Your Terminal Block... 5 Installing the Analog Bus Plug... 6 Specifications... 8 The TB-2606 consists of a printed circuit board with screw terminals. The terminal block connects directly to the front panel I/O connector of the NI 2501 or NI 2503. The TB-2606 provides the necessary routing to configure the NI 2501 or NI 2503 as a 6 4 two-wire matrix. The NI 2501 and NI 2503 have four 6 1 two-wire multiplexers. The modules can internally connect the four 6 1 multiplexers to create a 24 1 two-wire multiplexer. However, the TB-2606 is needed to provide the necessary wiring so the four 6 1 multiplexers are configured as a 6 4 two-wire crosspoint matrix. The TB-2606 provides screw terminal connections to the column and row inputs of the matrix. The front side of the terminal block has two additional connectors for connecting to the analog bus. You can use the low-voltage AB plug to connect the analog bus of adjacent switch cards.

What You Need to Get Started Signal Names You need the following to set up and use your terminal block: One of the following PXI switch cards: NI 2501 NI 2503 NI 2501/2503 User Manual TB-2606 terminal block 0.10 in. slotted screwdriver No. 1 Phillips screwdriver Wire cutters Wire insulation stripper Analog bus connectors (to connect to multiple cards) The TB-2606 provides the following screw terminal connections. Name Pin Number Name Pin Number R0-27 C3-30, 21, 13, 3 R0+ 61 C3+ 64, 55, 47, 37 R1-26 C4-29, 20, 12, 2 R1+ 60 C4+ 63, 54, 46, 36 R2-10 C5-28, 19, 11, 1 R2+ 44 C5+ 62, 53, 45, 35 R3-9 AB0-18 R3+ 43 AB0+ 52 C0-33, 25, 16, 6 AB1-17 C0-67, 59, 50, 40 AB1+ 51 C1-32, 24, 15, 5 EXTERNAL TRIGGER 41 C1+ 66, 58, 49, 39 SCAN ADVANCED 42 C2-31, 23, 14, 4 GND 7, 56 C2+ 65, 57, 48, 38 CHSGND CONNECTOR SHELL Type Title Here 2 ni.com

Signal Connection See your NI 2501/2503 User Manual for examples of how to connect your signals. Refer to Figure 1 as you perform the following steps to connect your signals to your terminal block (the numbers in parentheses refer to items in Figure 1). 1. Remove the terminal block cover (1) by unscrewing the two cover screws (2) using the 0.10 in. slotted screwdriver. 2. Loosen or remove the strain relief bar (3) by loosening the two strain relief screws (10). 3. Use wire cutters and wire insulation strippers to strip the wire ends as necessary to connect them to screw terminals. 4. Loosen the screws in the screw terminals with the 0.10 in. slotted screwdriver. 5. Insert the stripped wires into the screw terminals. Tighten the screws with the 0.10 in. slotted screwdriver. 6. Connect safety ground or shield wires to the chassis ground connection tab (7) using the provided solder lug (6). 7. Tighten or replace the strain relief screws (10). 8. Replace the terminal block cover (1) and tighten the cover screws (2). National Instruments Corporation 3 Type Title Here

1 3 2 4 5 6 7 8 4 9 10 1 Cover 2 Cover Screws (captive) 3 Strain Relief Bar 4 Chassis Connection Screws 5 Ground Lug Screw 6 Ground Solder Lug 7 Chassis Ground Tab 8 Connection to Switch Card 9 Analog Bus Connectors 10 Strain Relief Screws Figure 1. TB-2606 Parts Locator Diagram Type Title Here 4 ni.com

Installing Your Terminal Block Refer to Figure 2 as you perform the following steps to connect the terminal block to the NI 2501 or NI 2503 connector (the numbers in parentheses refer to items in Figure 2). Note The TB-2606 terminal block must be installed on the NI 2501/2503 switch card after the card is installed in the chassis. 1. Install the switch card (3) into the chassis and tighten the two module screws (2). 2. Guide the terminal block onto the switch card connector (4). 3. Tighten the two terminal block mounting screws (1). Caution The connectors of both the switch card and the terminal block are polarized. You can attach them in only one way. Do not force the terminal block when inserting it into or removing it from the NI 2501 or NI 2503 connector. National Instruments Corporation 5 Type Title Here

3 2 1 4 2 1 1 Terminal Block Mounting Screws 2 Module Screws 3 Switch Card 4 Switch Card Connector Installing the Analog Bus Plug Figure 2. Connecting the TB-2606 to the Switch Card Refer to Figure 3 as you perform the following steps to install the analog bus plug. The cover should be attached to the terminal block before you connect the analog bus plug because the plug screws into the cover (the numbers in parentheses refer to items in Figure 3). 1. With two terminal blocks connected to boards in adjacent slots, connect the analog bus plug (3) into the analog bus connector (1) of each terminal block. 2. Tighten the screw (2) on the analog bus plug using the 0.10 in. slotted screwdriver. Type Title Here 6 ni.com

1 2 3 1 Analog Bus Connector 2 Analog Bus Plug Screw 3 Analog Bus Plug Figure 3. Installing the Analog Bus Plug National Instruments Corporation 7 Type Title Here

Analog Bus Connector The front side of the terminal block has two connectors for connecting to the analog bus. The low-voltage analog bus plug can be used to connect the analog buses of adjacent switch cards, as shown in Figure 3. The signal connections for the analog bus are shown in Figure 4. No Connection AB0+ AB1+ No Connection AB1+ AB0+ AB1 No Connection AB0 AB1 No Connection AB0 Figure 4. Analog Bus Connector Specifications Dimensions...8.4 by 10.7 by 2.0 cm (3.3 by 4.2 by 0.80 in.) Max voltage (signal + common mode)...each input should remain within 30 V rms or 60 VDC of ground and all other channels to eliminate the possibility of hazardous shock. National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 1999 2007 National Instruments Corporation. All rights reserved. 372260B Nov07

取り付けガイド TB-2606 端子台 目次 はじめに この取り付けガイドでは TB-2606 端子台の取り付け方法 および NI 2501 および NI 2503 PXI スイッチモジュールへの信号接続 使用する方法について説明しています はじめに... 1 使用する前に... 2 信号名... 2 信号接続... 3 端子台を取り付ける... 5 アナログバス用プラグを取り付ける... 6 仕様... 8 TB-2606 は ネジ留め式端子を装備したプリント基板で構成されています この端子台は NI 2501 または NI 2503 のフロントパネル I/O コネクタに直接接続できます また TB-2606 は NI 2501 および NI 2503 が 6 4 の 2 線式マトリックスとして構成される際に必要な接続経路を提供します NI 2501 および NI 2503 には 4 つの 2 線式 6 1 マルチプレクサがあります モジュールは 4 つの 6 1 マルチプレクサを内部的に接続し 2 線式の 24 1 マルチプレクサを作成します しかし 4 つの 6 1 マルチプレクサを 2 線式 6 4 クロスポイントマトリクスとして構成するには TB-2606 で必要な配線を行う必要があります TB-2606 ではマトリクスの列と行をネジ留め式端子で接続することができます この端子台のフロント側には アナログバスに接続できるコネクタが 2 つあります 低電圧 AB プラグを使用して隣接したスイッチカードのアナログバスに接続できます

使用する前に 端子台の設定および使用には 以下が必要です 次の PXI スイッチカードのいずれか 1 つ NI 2501 NI 2503 NI 2501/2503 ユーザマニュアル TB-2606 端子台 0.10 in. マイナスドライバー No. 1 プラスドライバーワイヤカッターワイヤストリッパー アナログバス用コネクタ ( 複数カードへの接続用 ) 信号名 TB-2606 のネジ留め式端子の接続は次のようになっています 名前 ピン番号 名前 ピン番号 R0 27 C3 30, 21, 13, 3 R0+ 61 C3+ 64, 55, 47, 37 R1 26 C4 29, 20, 12, 2 R1+ 60 C4+ 63, 54, 46, 36 R2 10 C5 28, 19, 11, 1 R2+ 44 C5+ 62, 53, 45, 35 R3 9 AB0 18 R3+ 43 AB0+ 52 C0 33, 25, 16, 6 AB1 17 C0 67, 59, 50, 40 AB1+ 51 C1 32, 24, 15, 5 EXTERNAL TRIGGER 41 C1+ 66, 58, 49, 39 SCAN ADVANCED 42 C2 31, 23, 14, 4 GND 7, 56 C2+ 65, 57, 48, 38 CHSGND CONNECTOR SHELL TB-2606 端子台取り付けガイド 2 ni.com/jp

信号接続 信号接続の例については NI 2501/2503 ユーザマニュアル を参照してください 次の手順に従って信号を端子台に接続する際には 図 1 を参照してください ( 括弧の中の番号は 図 1 にあるアイテムを示す ) 1. 0.10 in. マイナスドライバーを使用して 2 つのネジ (2) を外し 端 子台のカバー (1) を取り外します 2. 2 つのストレインリリーフネジ (10) を緩めてストレインリリーフ バー (3) を緩める または取り外します 3. ワイヤカッターおよびワイヤストリッパーを使用して ネジ留め式端 子に接続できるようにワイヤの両端の絶縁被覆を少し取り除きます 4. ネジ留め式端子のネジを 0.10 in. のマイナスドライバーで緩めます 5. 裸線部分をネジ留め式端子に挿入します 0.10 in. マイナスドライ バーでネジを締めます 6. 付属の圧着端子 (6) を使用して 接地ワイヤまたはシールドワイヤ をグランド接続用タブ (7) に接続します 7. ストレインリリーフネジ (10) を締める または取り付けます 8. 端子カバー (1) を元のように取り付けて ネジ (2) を締めます National Instruments Corporation 3 TB-2606 端子台取り付けガイド

1 3 2 4 5 6 7 8 4 9 10 1 カバー 2 カバー用ネジ ( 拘束 ) 3 ストレインリリーフバー 4 シャーシ接続用ネジ 5 接地端子用ネジ 6 接地用圧着端子 7 シャーシ接地用タブ 8 スイッチカードへの接続口 9 アナログバス用コネクタ 10 ストレインリリーフネジ 図 1 TB-2606 部品位置のダイアグラム TB-2606 端子台取り付けガイド 4 ni.com/jp

端子台を取り付ける 以下の手順を実行して端子台を NI 2501 または NI 2503 コネクタに接続する際は 図 2 を参照してください ( 括弧の中の番号は 図 2 にあるアイテムを示す ) メモ NI 2501/2503 スイッチカードをシャーシに取り付けた後に TB-2606 端子台をカードに取り付ける必要があります 1. スイッチカード (3) をシャーシに取り付けて 2 つのモジュールネジ (2) を締めます 2. 端子台をスイッチカードのコネクタ (4) に接続します 3. 2 つの端子台取り付けネジ (1) を締めます 注意 スイッチカードと端子台の両コネクタには極性があります そのため 一方向にのみ接続可能です NI 2501 または NI 2503 コネクタに端子台を無理やり押し込んだり力ずくで外したりしないでください National Instruments Corporation 5 TB-2606 端子台取り付けガイド

3 2 1 4 2 1 1 端子台取り付けネジ 2 モジュールネジ 3 スイッチカード 4 スイッチカードコネクタ 図 2 TB-2606 をスイッチカードに接続する アナログバス用プラグを取り付ける 以下の手順に従ってアナログバス用プラグを取り付ける際は 図 3 を参照してください アナログバス用プラグはカバーにネジ留めされるため プラグを接続する前にカバーを端子台に取り付けておく必要があります ( 括弧の中の番号は 図 3 の中のアイテムを示す ) 1. 隣接するモジュールに取り付けられた 2 つの端子台において 各端子台のアナログバス用プラグ (3) をアナログバス用コネクタ (1) に接続します 2. アナログバス用プラグのネジ (2) を 0.10 in. マイナスドライバーで締めます TB-2606 端子台取り付けガイド 6 ni.com/jp

1 2 3 1 アナログバス用コネクタ 2 アナログバス用プラグのネジ 3 アナログバス用プラグ 図 3 アナログバス用プラグを取り付ける National Instruments Corporation 7 TB-2606 端子台取り付けガイド

アナログバスコネクタ この端子台のフロント側には アナログバスに接続できるコネクタが 2 つあります 図 3 に示すように 低電圧アナログプラグを使用して隣接したスイッチカードのアナログバスに接続できます 図 4 は アナログバスの信号接続を示します No Connection AB0+ AB1+ No Connection AB1+ AB0+ AB1 No Connection AB0 AB1 No Connection AB0 図 4 アナログバス用コネクタ 仕様 外形寸法...8.4 10.7 2.0 cm (3.3 4.2 0.80 in.) 最大電圧 ( 信号 + コモンモード )... 感電によるショックを防止するためには 各入力値を 30 V rms 内 またはグランドとその他すべてのチャンネル間は 60 VDC 以内にする必要があります National Instruments NI ni.com および LabVIEW は National Instruments Corporation ( 米国ナショナルインスツルメンツ社 ) の商標です National Instruments の商標の詳細については ni.com/legal の Terms of Use セクションを参照してください 本文書中に記載されたその他の製品名および企業名は それぞれの企業の商標または商号です National Instruments の製品を保護する特許については ソフトウェアに含まれている特許情報 ( ヘルプ 特許情報 ) CD に含まれている patents.txt ファイル または ni.com/patents のうち 該当するリソースから参照してください 1999 2007 National Instruments Corporation. All rights reserved. 372260B-01 2007 年 11 月