Similar documents
I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STW Symbol Symbol otary switch) 05 otary switch Symbol angle of notch 181

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility Fro

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T box number basic type Standard Specification Material of Enclosure Material of F

LC304_manual.ai

1 2 3

Microsoft Word - PCM TL-Ed.4.4(特定電気用品適合性検査申込のご案内)

untitled


080906_…o…−…^…b…vVSCW

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

xEffect_SG_MV_Part2_E_xEffect_SG_MV_E

Tornado Series selection SW TiCN HSS Co FAX VL PM

03-03 Bush Mentori.pdf

メタルバンドソー

音響部品アクセサリ本文(AC06)PDF (Page 16)

Connectors for Automobiles 62 SEALED SERIES Japanese English

The hand operated type HB unit is a worm gear drive which may be used for any valve or device requiring a 90 movement. The HB worm gear actuator is es

fx-9860G Manager PLUS_J

WIF6002-e

TK-M700…p†[…c…−…X…g

Direct Motor Drive Lead Screws / Resin Lead Screw type RM / RM RM Resin Lead Screw type RM / Resin MoBo 2 MRH 2 Features A 2-phase Stepping Motor is m

00_1512_SLIMLINE_BOOK.indb

Options(Unit : mm) Finger guards Model :19-139E :19-139H 53 Surface treatment :Nickel-chrome plating (silver) :Cation electropainting (black) Inlet si

2

2

alternating current component and two transient components. Both transient components are direct currents at starting of the motor and are sinusoidal

01.eps


1..FEM FEM 3. 4.

KOMET KUB K2® 小径対応ヘッド交換式ドリル

2 3

(1 ) (2 ) Table 1. Details of each bar group sheared simultaneously (major shearing unit). 208

*Ł\”ƒ‚ä(DCH800)

cms.pdf


PC_14ZY6_BFT150A_US_ indd

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

DIN Connector_p2-25.qxd

Specification for Manual Pulse Generator, GFK-2262


C(W)500 AT,TK PB

2

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

アクアEXオイルホールロング(CC2015).indd

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part


BS・110度CSデジタルハイビジョンチューナー P-TU1000JS取扱説明書

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

03-01 Senyouki.pdf

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

WE WESB WENB WESNB 428

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

DZ-GX20/DZ-MV780取扱説明書(上巻)

;y ;y ;; yy ;y;; yy y;y;y;y ;y; ;; yy ; y Portable CD player Operating Instructions RQT5364-S

2

Features Features FeaturesThread milling cutters 1


Fig. 1 Schematic construction of a PWS vehicle Fig. 2 Main power circuit of an inverter system for two motors drive

Tab 5, 11 Tab 4, 10, Tab 3, 9, 15Tab 2, 8, 14 Tab 1, 7, 13 2


H8000操作編

NEW AquaREVO Drills Stub/Regular AQRVDS AQRVDR


KSKH(MX).indd

0 C C C C C C C

UT(W1600).indd

Fig, 1. Waveform of the short-circuit current peculiar to a metal. Fig. 2. Waveform of arc short-circuit current. 398 T. IEE Japan, Vol. 113-B, No. 4,

Options Unit : mm Finger guards Color Model Surface treatment Nickel-chrome plating silver DC Fan 4mm Air Flo

C FGIH C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C

Page 1 of 6 B (The World of Mathematics) November 20, 2006 Final Exam 2006 Division: ID#: Name: 1. p, q, r (Let p, q, r are propositions. ) (10pts) (a

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part


Huawei G6-L22 QSG-V100R001_02

TH-42PAS10 TH-37PAS10 TQBA0286


% + RP-BC30 BATTERY CHARGER STAND K -! # % $ $ % % # $ $ $ %

- 1 -

Z7000操作編_本文.indb

Thread Milling Cutter Series

2

DZ-HS503 取扱説明書

HG…p†[…c…J…^…“…O

+ -

IEC :2014 (ed. 4) の概要 (ed. 2)


/ Motor Specifications Direct Motor Drive Ball Screws / Precision Ball Screw type MB / MB MB Precision Ball Screw type MB / MoBo C3 5 5 Features A 5-p

GP05取説.indb

Journal of Japan Institute of Light Metals, Vol. 58, No. 2 (2008), pp

Air Flow - Static Pressure Characteristics PWM Duty Cycle % 1% 5% CRA312P4K

Continuous Cooling Transformation Diagrams for Welding of Mn-Si Type 2H Steels. Harujiro Sekiguchi and Michio Inagaki Synopsis: The authors performed

untitled

DZ-GX3300/GX3100/GX3100取扱説明書

DZ-HS303 取扱説明書

MIDI_IO.book

19_22_26R9000操作編ブック.indb

取説_VE-PV11L(応用編)

FG/FCG Pressure-Temperature Compensated Flow Control Valves, Tokyo Keiki Inc.

MINAS取説アブソ警告クリア方法記載ミス_モータニュース…

58 W type W タイプコネクタとは 58 コネクタ S タイプ (M ターミナルタブ幅 2.8mm) の防水コネクタです W TYPE CONNECTOR: THE BLADE WIDTH OF THE MALE TERMINAL FOR THIS CONNECTOR IS IN

Transcription:

02

03

04

05

06

07

01 01 11

01 Flameproof Junction Box Junction Box Series Our junction boxes are designed and manufactured based on the Recommended Practices for Explosion-Protected Electrical Installations in General Industries NIIS-TR-NO.39 (2006) 2852 instruction for junction box as pull box and Junction box. Cable entries will be designed on quantity and size requested by customer. Concerning Junction Box, there is no explosion proof certification system in Japan, therefore Explosion proof Certificate or Explosion proof Label on products are not available. The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight to 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. Junction Box can be available for Zone 1 and Zone 2 Hazardous Area as Terminal Box. Standard Threads for.conduit piping shall be PF (B-class) Threads but, when needing A-class Threads, please specify A- class threads (PF or G) when ordering. The threads will be applied PF (B-class) if ordering Conduit size such as G16, G22 and etc. Requirement for Hydrogen Explosion Protection (d3a) The products below mentioned can be applied for Hydrogen hazardous protection with special threads and additional price. Cable Glands for Hydrogen hazardous protection shall be used for type SXBM (A-class : custom made) and type SXC-B (A-class : custom made). 12

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T box number basic type Standard Specification Material of Enclosure Material of Fixing Bolt Material of Sealing Packing Painting Color Aluminum Alloy Casting Stainless Steel Chloroprene Rubber Meramine stove paint Outside 01 Ambient Temperature Subject to non freezing Relative Humidity Subject to condensation Altitude 1000m or less Standard Specification Material of Enclosure Aluminum Alloy Casting box number basic type Material of Sealing Packing Painting Color Chloroprene Rubber Meramine stove paint Outside Ambient Temperature Subject to non freezing Relative Humidity Subject to condensation Altitude 1000m or less When ordering, please fill Information Sheet on page44. After the order we cannot accept any change of cable entries. 13

01 Flameproof Junction Box STH-04/06 14

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-04/06 01 NPT 15

01 Flameproof Junction Box STH-0 16

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 17

18 Flameproof Junction Box 01 STH-1 STH-1 STH-1

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 19

20 Flameproof Junction Box 01 STH-3 STH-3 STH-3

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 21

22 Flameproof Junction Box 01 STH-5 STH-5 STH-5

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 23

24 Flameproof Junction Box 01 STH-6 STH-6 STH-6

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 25

26 Flameproof Junction Box 01 STH-7 STH-7 STH-7

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 27

28 Flameproof Junction Box 01 STH-8 STH-8 STH-8Vertical Vertical Vertical

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 29

30 Flameproof Junction Box 01 STH-8 STH-8 STH-8Horizontal Horizontal Horizontal

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 31

32 Flameproof Junction Box 01 STH-9 STH-9 STH-9

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 33

34 Flameproof Junction Box 01 STH-11 STH-11 STH-11

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 35

36 Flameproof Junction Box 01 STH-12 STH-12 STH-12

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 37

38 Flameproof Junction Box 01 STH-13 STH-13 STH-13

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 39

40 Flameproof Junction Box 01 STH-3M1 STH-3M1 STH-3M1

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STH-5M1 01 41

42 Flameproof Junction Box 01 STH-7M1 STH-7M1 STH-7M1

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STH-9M1 01 43

44

01 IFlameproof N S T R UPull M EBox N T A T I O N & E L E C T R I C A L E Q U I P M E N T The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight to 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. 01 Please use the Pull Box depends on the Cable Entry size, number and connections. Standard Threads for.conduit piping shall be PF (B-class) Threads but, when needing A-class Threads, please specify A-class threads (PF or G) when ordering. The threads will be applied PF (B-class) if ordering Conduit size such as G16, G22 and etc. box number basic Type Standard Specification Material of Enclosure Material of Sealing Packing Painting Color Ambient Temperature Relative Humidity Altitude Aluminum Alloy Casting Chloroprene Rubber Meramine stove paint Outside Subject to non freezing Subject to condensation 1000m or less When ordering, please fill Information Sheet on page54. After the order we cannot accept any change of cable entries. 45

01 Flameproof Pull Box SPH-11 46

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 47

01 Flameproof Pull Box SPH-111 48

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 49

01 Flameproof Pull Box SPH-12 50

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 51

01 Flameproof Pull Box SPH-13 52

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 53

54

01 Increased safety Junction Box The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight to 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. 01 Junction Box can be available for Zone 2 Hazardous Area as Terminal Box. Standard Threads for.conduit piping shall be PF (B-class) Threads but, when needing A-class Threads, please specify A-class threads (PF or G) when ordering. The threads will be applied PF (B-class) if ordering Conduit size such as G16, G22 and etc. box number basic Type Standard Specification Material of Enclosure Material of Fixing Bolt Material of Sealing Packing Painting Color Ambient Temperature Relative Humidity Altitude Aluminum Alloy Casting Stainless Steel Chloroprene Rubber Meramine stove paint Outside Subject to non freezing Subject to condensation 1000m or less box number basic Type Standard Specification Material of Enclosure Material of Fixing Bolt Material of Sealing Packing Painting Color Ambient Temperature Relative Humidity Altitude Stainless Steel Stainless Steel Chloroprene Rubber Plain Subject to non freezing Subject to condensation 1000m or less When ordering, please fill Information Sheet on page89 or 96. After the order we cannot accept any change of cable entries. 55

56 Increased safety Junction Box 01 ASTH-8 ASTH-8 ASTH-8

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 57

01 Increased safety Junction Box ASTH-10 58

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 59

60 Increased safety Junction Box 01 ASTH-20 ASTH-20 ASTH-20

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 61

62 Increased safety Junction Box 01 ASTH-30 ASTH-30 ASTH-30

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 63

64 Increased safety Junction Box 01 ASTH-60 ASTH-60 ASTH-60

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 65

66 Increased safety Junction Box 01 ASTH-70 ASTH-70 ASTH-70

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 67

68 Increased safety Junction Box 01 ASTH-90 ASTH-90 ASTH-90

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 69

70 Increased safety Junction Box 01 ASTH-100 Vertical ASTH-100 Vertical ASTH-100 Vertical

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 71

72 Increased safety Junction Box 01 ASTH-100 ASTH-100 ASTH-100 Horizontal Horizontal Horizontal

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 73

74 Increased safety Junction Box 01 ASTH-110Vertical ASTH-110Vertical ASTH-110Vertical

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 75

76 Increased safety Junction Box 01 ASTH-110 ASTH-110 ASTH-110Horizontal Horizontal Horizontal

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 77

78 Increased safety Junction Box 01 ASTH-130 ASTH-130 ASTH-130

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 79

80 Increased safety Junction Box 01 ASTH-140 ASTH-140 ASTH-140

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 81

01 Increased safety Junction Box ASTH-160 82

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 83

01 Increased safety Junction Box ASTH-160L 84

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 01 85

86 Increased safety Junction Box 01 ASTH-20M ASTH-20M ASTH-20M

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ASTH-30M 01 87

88 Increased safety Junction Box 01 ASTH-40M ASTH-40M ASTH-40M

89

90 Increased safety Stainless Steel Junction Box 01 SXTB-1 SXTB-1 SXTB-1

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-2 SXTB-2 SXTB-2 01 91

92 Increased safety Stainless Steel Junction Box 01 SXTB-3 SXTB-3 SXTB-3 SXTB-3 SXTB-3 SXTB-3

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-4 SXTB-4 SXTB-4 01 93

94 Increased safety Stainless Steel Junction Box 01 SXTB-5 SXTB-5 SXTB-5 SXTB-5 SXTB-5 SXTB-5

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-75 SXTB-75 01 95

96

97 01 01 Terminal 01

01 Types of name plate 98

01 Hood 01 99

01 Table 100

02 Conduit Fitting and Accessories Explanation Hot dip galvanized size Type Y 45 45 degree back cover YB 45 45 degree side cover B 90 90 degree back cover T Tee side cover Flameproof Elbow and Tee This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. The products are also provided sealing packing for water proof purpose and available outdoor use. basic type Hot dip galvanized size Type 90 degree back cover 90 degree left cover 90 degree right cover 45 degree back cover 45 degree side cover Tee back cover Tee side cover size basic type Hot dip galvanized Type Vertical Universal with Drain basic type Increased Safety Elbow and Tee The products are also provided sealing packing for water proof purpose and available outdoor use. This product can be use for Zone 2 with easy to install and construction by 2 screws. Flameproof Sealing Fitting This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. 102

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Hot dip galvanized cover type Standard Dome size Type 3-way 4-way basic type Hot dip galvanized size Type 3-way 4-way basic type Flameproof Junction Box This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. The products are also provided sealing packing for water proof purpose and available outdoor use. Increased Safety Junction Box The products are also provided sealing packing for water proof purpose and available outdoor use. This product can be use for Zone 2 with easy to install and construction. For the stop screw, it can do installation very easily 02 Female thread Male thread Type adaptor reducer basic type Flameproof Adaptor and Reducer This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product can be use when you have discrepancies between the size of Conduit Pipe and Cable Entries. 103

02 Conduit Fitting and Accessories size Type Male thread x Female thread Flameproof Union Coupling This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product is available for union purpose. basic type size basic type Flameproof Nipple This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product is available for connector between Conduit Pipe. size basic type Flameproof 90degree Elbow This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product is available for connector to bend 90 degree connection at narrow space. size basic type Flameproof Close-up Plug This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product is available for closed plug of spare cable entries. Hot dip galvanized size basic type 104

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T size basic type Flameproof Breather This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product is available for drain and breath of box. 02 size basic type Flameproof Drain This product can be use for hazardous location Zone 1 and Zone 2 with easy to install and construction. This product can be use when the dew condensation which accumulates inside the box is discharged size Clamp basic type This product can be use for fixing and support of Conduit Pipe. 105

02 Flameproof Elbow and Tee SXEY-16H54H45 SXEYB-16H54H45 106

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXEB-16H54H90 02 SXET-16H54H 107

02 Increased Safety Elbow and Tee ISEB-16H54H90 108

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ISEL-16H54H90 02 ISER-16H54H90 109

02 Increased Safety Elbow and Tee ISEY-16H54H45 ISEYB-16H54H45 110

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ISEF-16H54H 02 ISET-16H54H 111

02 Increased Safety Branch Box ISE282-162H ISE28-162H 112

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ISE282-163H 02 ISE28-163H 113

02 Flameproof Sealing Fitting SFT-16H28H SFT-36H104H 114

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SFG-16H104H 02 SFD-16H104H 115

02 Sealing Compound S-kon developed by Shimada Electric, is a sealing compound with the following outstanding features. A) Inorganic components provide non-inflammable performance. B) Sealing can be obtained simply by adding water and stirring the mixture. C) Hardening begins 30 minutes after mixing at room temperature. D) Excellent adherence prevents cracks and deformation. The sealing compound (bulk fiber)only, (50g) Operating hole Filler hole Sealing installation Operation of the sealing in metallic conduit wiring depends next Either of the partitions of the electric wire pipe conduit which penetrates the partition with Zone 1 place and the other place side of one side. However in the electric wire pipe conduit with the sealing fitting and the partition do not provide the joint on the middle. In the electric wire pipe conduit of 54 or more, when as a general rule within the 45áp, place, and the pipe conduit length which if possible are approached to that exceed 15m from the terminal box or the boxes which receives the wire splicing part, Every below pipe conduit long 1m in the ratio 1 suitable place. 116

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T With the conduct tube which enters and leaves the terminal box and the joint box of the switchboard and the cabinet panels, from these the place where if possible it approaches to those within the 45áp Above inside diameter of the conduct tube (smallest 20mm) height of being full layer of the sealing compound, to become. 02 S-kon How to use : After the line is completing, In addition to you inspect presence error such as wiring, As description below please use 1, With the white cottony sealing fiber which we have attached to make the sealing dam on the bottom of packed bed, please flow out and preventing 2, Mix water 45cc for S Kon 100g, and please fill it up after stirring it well. 3, When you pour fitting while beating lightly, to fill air tightly, it's more effective. 4, After fill the dense plug for 30 minute, please do not move the plug. 5, Please be careful sufficiently so that sealing compounding doesn't span the screw part of a filler inlet. This CAN adds tap water, and I have decided to be stirred rather a little big 117

02 Sealing Compound 118

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 02 119

02 Flameproof Junction Box SGT-16H54H 120

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SGX-16H54H 02 121

02 Flameproof Junction Box SGT-16DH54DH 122

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SGX-16DH54DH 02 123

02 Increased Safety Junction Box ASGT-16H54H 124

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ASGX-16H54H 02 125

02 Flameproof Adaptor SA22-16104-70 126

02 Flameproof Reduser SR16-2270-104 02 127

02 Flameproof Union Coupling SUM-16104 SUF-16104 128

02 Flameproof Nipple 90degree Elbow SNP-16104 02 SSE-1628 129

02 Flameproof Close-up Plug SBPN-1654 SMB-70H104H 130

02 Flameproof Breather Drain SBC-3/81 02 SDC-3/81 131

02 Clamp SC-1654 132

03 Flameproof Cable Gland Cable Gland This is the Flameproof Cable Glands to use for Cable Wiring in the hazardous location. It is much easier to install and maintenance and modification compared with Conduit Wiring with Sealing Fitting. The Standard Threads are applied PF (B-class). G(A-class). Please be sure to read the following item to have use it safely without reusing. 1, The packing used once, please be sure to exchange it. The explosion protection performance can't be maintained any more. Please tighten. 2, Packing up surely. Please use something a gap inside the cable isn't so that flammable gas may be difficult to pour into. 3, A used cable (), and the cable surface is smooth and unevenness isn't and by which a section is a cylinder. There is nothing set especially with the cable it's possible to use for explosion protection construction, but CV, CVS and VCT, etc. will recommend you because there are no inner gaps. When using a Corrugated cable. Please select SXK. using a cable (Corrugated cable), please select SXK. 134

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility From research institute of industrial safety technical guide. Appendix 3 1.2.1 pressure-resistant single hole gasket type retreat methodological Hardness (JIS spring type hardness Hs) 45~65 Pull strength 7MPa above Extension 350% or more As for depth of the induction penetration section after the gasket tightening, when it is below the 2cm 3 according to the content volume of the container, below the ~100cm 3 above 5mm and above the 2cm 3 when above 8mm, it exceeds the 100cm 3, it makes above 12mm. Minimum of effective bulk compressibility of the gasket does 5%. 03 Table Standard angle and dimension of Threads 135

03 Flameproof Cable Gland EXPC-16B28B Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass Packing number B(for fixing equipment) size basic type Chloroprene Rubber Nitrile Rubber Nickel electroplating Select Packing Number 136

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T EXBM-16B28B Packing number Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass B(for fixing equipment) size basic type Chloroprene Rubber Nitrile Rubber Nickel electroplating 03 Select Packing Number 137

03 Flameproof Cable Gland SXBM-16B28B Packing number B(for fixing equipment) size basic type When it is below the content 2000cm 3 ExdC it is enabled. Below the content 6000cm 3 it is enabled with d3a only in case of the screw of A class. Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass Chloroprene Rubber Nitrile Rubber Nickel electroplating Select Packing Number 138

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXC-16B54B SXC-16BY54BY Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass Packing number Packing case without O-ring Packing case with O-ring B(for fixing equipment) size basic type Chloroprene Rubber Nitrile Rubber Nickel electroplating 03 in the drawing is BY type Select Packing Number 139

03 Flameproof Cable Gland NSTPC-16104 NSTPC-16Y104Y Packing number Packing case without O-ring Packing case with O-ring B(for fixing equipment) R(for movement equipment) size basic type Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass Chloroprene Rubber Nitrile Rubber Nickel electroplating in the drawing is Y type Thread size more than 70 Select Packing Number 140

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T CSFX-16B54B When it is below the content 2000cm 3 ExdC it is enabled. Packing number Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass B(for fixing equipment) size basic type Chloroprene Rubber Nitrile Rubber Nickel electroplating 03 Select Packing Number 141

03 Flameproof Cable Gland (Corrugated) SXK-1654 Standard Specification Substance material Pressure resistant packing material O-ring material Surface treatment Brass Conformity cable range number (outer) Conformity cable range number (inner) size basic type Chloroprene Rubber Nitrile Rubber Nickel electroplating When it is below the content 2000cm 3 ExdC it is enabled. Armoring Dia. Select Packing Number 142

03 Flameproof Cable Gland SBM-16104 Standard Specification Packing number B(for fixing equipment) R(for movement equipment) size basic type Substance material Pressure resistant packing material Surface treatment Standard Specification Substance material Pressure resistant packing material Surface treatment Zinc alloy die-cast Chloroprene Rubber Nickel electroplating Brass Chloroprene Rubber Nickel electroplating 03 Thread size more than 70 Select Packing Number 143

03 Flameproof Cable Gland ESBM-1622 Standard Specification Material Pressure resistant packing material Surface treatment Packing number B(for fixing equipment) R(for movement equipment) size basic type Substance:Brass Gland:Zinc alloy die-cast Chloroprene Rubber Nickel electroplating Select Packing Number 144

03 General Machine Use Cable Gland CSW-16CR104CR size basic type Standard Specification Substance material Packing material Surface treatment Brass Chloroprene Rubber Nickel electroplating 03 CSW-16BCR104BCR B(for fixing equipment) size basic type Standard Specification Substance material Packing material Surface treatment Brass Chloroprene Rubber Nickel electroplating 145

Flameproof Cable Gland Parts 146 03 Number A type size basic type Above table applied for following cable glands

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Number B type size 03 basic type Above table applied for following cable glands Packing Numbers are only 1 and 2 for CSFX, SXK, SXC, SXV, SXS, SXG, SXM in each size. Number C type size basic type Above table applied for following cable glands 147

03 Flameproof Cable Gland Parts 148

04 Flexible Conduit Explanation size Male Thread Female Thread basic type size Male Thread Female Thread basic type Packing number packing case with O-ring packing case without O-ring size basic type Packing number basic type size basic type Packing number packing case with O-ring packing case without O-ring size basic type Packing number packing case with O-ring packing case without O-ring size basic type 150

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector packing case with O-ring packing case without O-ring size length basic type 04 151

04 Flexible Conduit Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector packing case with O-ring packing case without O-ring size length basic type Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector packing case with O-ring packing case without O-ring size length basic type Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector packing case with O-ring packing case without O-ring size length basic type 152

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Packing number size length basic type Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type 04 If other length required, please fill followings Indicate the length in millimeter Male connector x Female connector Male connector x Male connector Female connector x Female connector size basic type Please refer page146,147 for packing details 153

04 Flexible Conduit Component Details ST-16104 Flexible Covering Steel Vinyl chloride STM-16104 STF-16104 154

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T NSTPG-16104 NSTPG-16Y104Y 04 Select Packing Number 155

04 Flexible Conduit Component Details SXG-1654 SXG-16Y54Y Select Packing Number ESTPG-1622 ESTPG-16Y22Y Select Packing Number 156

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T MYLEX-1654 Flexible Covering Steel Vinyl chloride SLEX-1654 04 Flexible Covering Steel Vinyl chloride 157

04 Flexible Conduit Component Details MSM-1654 MSF-1654 158

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T MSW-1654 04 SXM-16G54G Select Packing Number 159

04 Flexible Conduit Component Details Flexible 160

04 Flexible Conduit Bend Radius As for efficiency of the flexible conduit for piping of flameproof construction the bending test which parallels to the cylinder which possesses the diameter of 10 times that of finished major diameter of the part of the tube in normal temperature 10 times it cannot raise the abnormality of the time and cracking etc over again, furthermore withstand the internal hydraulic power of 20kgf/cm 2. (From explosion-proof guide) Efficiency of the flexible conduit for wiring of safe increase explosion-proof construction has the diameter of 10 times that of finished major diameter of the part of the tube in normal temperature. The bending test which parallels to the cylinder 10 times the time, do not cause cracking and other abnormalities over again. (From explosion-proof guide) The bottom chart internal diameter of the flameproof construction flexible conduit, bend radius when using, machine strength, show weight 04 blade blade 161

04 Flameproof Flexible Conduit SFC-16104 Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type Flexible : stainless steel Stainless steel wire 162

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SFCS-16104 Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type Flexible : stainless steel Stainless steel wire 04 163

04 Flameproof Flexible Conduit with Cable Glands NSTPS-16104 NSTPS-16Y104Y Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector Flexiblestainless steel wire Packing case with O-ring this item has certificate of Exd IIB size length basic type Select Packing Number 164

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T NSTPV-16104 NSTPV-16Y104Y Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector Flexible Covering Packing case with O-ring this item has certificate of Exd IIB size length basic type Select Packing Number 04 165

04 Flameproof Flexible Conduit with Cable Glands SXS-1654 SXS-16Y54Y Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector Packing case with O-ring this item has certificate of Exd IIB size length basic type Flexiblestainless wire Select Packing Number 166

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXV-1654 SXV-16Y54Y Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector Packing case with O-ring this item has certificate of Exd IIB size length basic type Flexible Covering 04 Select Packing Number 167

04 Flameproof Flexible Conduit with Cable Glands SXM-1654 Packing number Flameproof connector x Female connector Flameproof connector x Male connector both ends Flameproof connector size length basic type Flexible Select Packing Number 168

04 Increased Safety Flexible Conduit SFAC-16104 Male connector x Female connector Male connector x Male connector Female connector x Female connector size length basic type Flexible Covering 04 169

05 Flameproof Push Button Switch EXPB-1 Standard Specification Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 172

05 Flameproof Selector Switch EXSS-1 05 Standard Specification Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB Normal point of contact constitution Normal point of contact constitution 173

05 Flameproof Rotary Switch EXCS-1 Standard Specification Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 174

05 Flameproof Indicator Light EXPL-1 Standard Specification Globe Hard Glass Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 05 Lens Color Red Green Yellow Amber White AC110 220V is trans type. DC110V is DC-DC connecter type. 175

05 Flameproof Ammeter/Voltmeter EXAM-1- EXVM-1- Instrument rating Ammeter Voltmeter Product type Standard Specification Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 176

05 Flameproof Tumbler Switch EXTS-151 1 Gang Rated Current Contact arrangement Product type 05 Standard Specification Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 177

05 Flameproof Tumbler Switch STS-152 Two gang Rated Current Contact arrangement Product type Standard Specification 178

179

05 Flameproof Control Box These items are using an aluminum alloy cast, so the weight is corrosion-resistant and excel halo tolerance and is light-weight and it's about 1/3 compared with conventional cast iron and made of steel plate. Therefore abbreviation of the cost performance and the crane which carries around and is an installation stand to a work site is useful for labor-saving. You're using petroleum refinery, establishment of a chemical plant, the electric power and a common duct, addition and remodeling widely. The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. Please use Zone 1 for a connection of cable wire at a place and Zone 2 place. When it is used with the outside, inserting in the waterproof box. Stand Buzzer Pilot lamp Push button Selector switch Rotary switch Ammeter Number of the box Product type Standard Specification What is Control Equipment The Switches can be monitored and control for Electrical Equipment and Facilities which operated, measured, monitored, protected and combination. What is Control Box The various Control Equipment combined with Selector Switch, Amp meter, Pilot Lamp, Buzzer and etc.., and control, monitor for main circuit, control circuit and operation circuit. What is Operation Switch The various Operation Switches combined with Push Button, Selector switch, Cam Rotary Switch and etc., and controlled Electrical Equipment. What is Relay The built-in item the relay (only relay) those which consist When ordering, please fill information Sheet on page 199. 180

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STW Symbol Symbol otary switch) 05 otary switch Symbol angle of notch 181

05 Flameproof Control Box STW Rated Specification(Pilot lamp) Pilot lamp Symbol Rated Specification(Ammeter) Ammeter Symbol Rated Specification(Buzzer) Buzzer Symbol Rated Specification(Ammeter) Ammeter Symbol 182

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Symbol Symbol to change 30,100,200,500 to change 15,30,100,200,500 to change 30,100,200,500 05 Symbol Motor capacity 183

05 Flameproof Control Box STW-2 Same model official approval pass article 184

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example Combination of Ammeter and Switch Combination of Switch 05 Combination of Pilot Lamp and Switch 185

05 Flameproof Control Box STW-3 Same model official approval pass article 186

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example 05 187

05 Flameproof Control Box STW-5 Same model official approval pass article fuse Power consumption of relay and timer are : 1.2VA 188

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example Only Rotary switch 05 189

05 Flameproof Control Box STW-6 Same model official approval pass article Fuse Electro-magnetic contactor 190

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example 05 191

05 Flameproof Control Box STW-7 Same model official approval pass article Certificate number T25003, switch unit shall install with control switch with indicator lamp, buzzer or ammeter. Certificate number T48212, switch unit shall install with control switch with indicator lamp or ammeter Certificate number T49615, switch unit shall install with indicator lamp or buzzer It's installed and electric machinery rating of the unit is indicated on P181-183. A symbol of the installed unit is mention the below. 192

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example 05 193

05 Flameproof Control Box STW-7A5 Same model official approval pass article Fuse Thermal relay 194

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example 05 195

05 Flameproof Control Box STW-LB50/NF50 Same model official approval pass article Fuse Plugging Relay Current transformer 196

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Sample model example 05 197

05 Flameproof Control Box Standard Specification The whole type Standard Specification 198

199

06 Flameproof circuit breakers These items are using an aluminum alloy cast, so the weight is corrosion-resistant and excel halo tolerance and is light-weight and it's about 1/3 compared with conventional cast iron and made of steel plate. Therefore abbreviation of the cost performance and the crane which carries around and is an installation stand to a work site is useful for labor-saving. You're using petroleum refinery, establishment of a chemical plant, the electric power and a common duct, addition and remodeling widely. The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. Please use Zone 1 for a connection of cable wire at a place and Zone 2 place. The type of SNF is for outside user, please inserting in the water-proof box for use. Rated Current Ammeter Motor Breaker Frame size Poles number Basic type Standard Specification Rated Current Frame size Poles number Basic type Standard Specification When ordering, please fill information Sheet on page 209. 202

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SNF-230330 SNF-250350 06 203

06 Flameproof circuit breakers SNF-2100/3100 204

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SNF-250AM/350AM SNF-2100AM/3100AM 06 205

06 Flameproof circuit breakers EXNF Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 206

06 Flameproof earth leakage circuit breakers These items are using an aluminum alloy cast, so the weight is corrosion-resistant and excel halo tolerance and is light-weight and it's about 1/3 compared with conventional cast iron and made of steel plate. Therefore abbreviation of the cost performance and the crane which carries around and is an installation stand to a work site is useful for labor-saving. You're using petroleum refinery, establishment of a chemical plant, the electric power and a common duct, addition and remodeling widely. The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. Please use Zone 1 for a connection of cable wire at a place and Zone 2 place. Rated Current Frame size Poles number Basic type Standard Specification 06 When ordering, please fill information Sheet on page 209. 207

06 Flameproof earth leakage circuit breakers EXLB Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 208

209

06 Flameproof Electro-magnetic switch These items are using an aluminum alloy cast, so the weight is corrosion-resistant and excel halo tolerance and is light-weight and it's about 1/3 compared with conventional cast iron and made of steel plate. Therefore abbreviation of the cost performance and the crane which carries around and is an installation stand to a work site is useful for labor-saving. You're using petroleum refinery, establishment of a chemical plant, the electric power and a common duct, addition and remodeling widely. The adoption of Aluminum Alloy Casting corrosion resistance and reduced weight 1/3 of the conventional cast iron or steel plate boxes, ensures your labor saving plans with easy installation and wiring. Widely used in the construction of Refinery, Chemical, Power and Heavy Chemical Industries. Please use Zone 1 for a connection of cable wire at a place and Zone 2 place. The type of SMG is for outside user, please inserting in the water-proof box for use. Inreversible type Push Button switches (On,Off) Lamp Rated capacity Basic type Standard Specification Manual rest type (On,Off,Reset) Automatic return type (On,Off) Rated capacity Basic type Standard Specification When ordering, please fill information Sheet on page 220. Standard is automatic return. When you need manual reset, please specify O. 210

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SMG-122 Non Irreversible type Non operation switch 06 Standard Wiring drawing 211

06 Flameproof Electro-magnetic switch SMG-122-O Non Irreversible type operation switch Standard Wiring drawing 212

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SMG-3775 Non Irreversible type Non operation switch 06 Standard Wiring drawing 213

06 Flameproof Electro-magnetic switch SMG-175-R Irreversible type Non operation switch Standard Wiring drawing 214

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SMG-175-O Non Irreversible type operation switch 06 Standard Wiring drawing 215

06 Flameproof Electro-magnetic switch SMG-175-OR Irreversible type operation switch Standard Wiring drawing 216

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SMG-155-LO Non Irreversible type operation switch, Pilot Lamp 06 Standard Wiring drawing 217

06 Flameproof Electro-magnetic switch SMG-155-LOR Non Irreversible type operation switch, Pilot Lamp Standard Wiring drawing 218

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T EXMG Following Cable Gland is necessary attachment (additional charge) SXCB TypeSXCB 06 219

220

07 Increased safety Illumination Characteristics To attach to flat on the panel surface, because there are no times when air current inside the booth is disturbed it is optimum to the paint booth line. Front opening and closing type (type EFRA) with back opening and closing type (type EFRB) installation size and installation system are identical. It's the hinge system, so to remove 3 bolts can do a lamp exchange easily. Material of main parts Substance, Framework Steel sheet Front glass Tempered glass Terminal box Cast iron Reflector Steel sheet Specification Explosion class : eg3 Conformity lamp : FLR40S(FLR40S/36) Light method : Rapid start type Ballast safety measure : Protection mechanism attaching condenser built-in Frequency Painting Color : white (Body,Reflector) Melamine resin printing paint Hub Specification : PF3/4 (22) 4-way plug External form size Front opening and closing type (Type EFRA-4) Back opening and closing type (Type EFRB-4) 222

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Installation size (Front opening and closing type,back opening and closing type) Type Explanation Frequency 550Hz 660Hz Voltage 1100V 2200V Lamp 16 lampw 440W How to opening and closing A:Front opening and closing type B:Back opening and closing type Other voltage available on request. 07 223

07 Increased safety emergency fluorescent light 40W 50% (Only one Lamp ON ) Emergency power type (Battery built-in) Characteristics To attach to flat on the panel surface, because there are no times when air current inside the booth is disturbed it is optimum to the paint booth line. Front opening and closing type (type EFRA) with back opening and closing type (type EFRB) installation size and installation system are identical. It's the hinge system, so to remove 3 bolts can do a lamp exchange easily. Inspection switch, Charge monitor. Material of main parts Substance, Framework Steel sheet Front glass Tempered glass Terminal box Aluminum casting Reflector Steel sheet Reflector Aluminum casting Specification Explosion class : ed3ag3 Conformity lamp : FLR40S Light method : Rapid start type (Emergency high frequency) Ballast safety measure : Protection mechanism attaching condenser built-in Frequency Emergency luminous flux ratio : 30min or more Emergency luminous flux ratio : 50% above Painting Color : white (Body,Reflector) Melamine resin printing paint Hub Specification : PF3/4 (22) 4-way plug External form size Front opening and closing type (Type EFRA-4E) Back opening and closing type (Type EFRB-4E) 224

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Installation size (Front opening and closing type,back opening and closing type) Type Explanation Emergency Lamp Frequency 550Hz 660Hz Voltage 1100V 2200V Lamp 16 LampW 440W How to opening and closing A:Front opening and closing type B:Back opening and closing type 07 Other voltage available on request. Connecting diagram 225

07 Flameproof illumination hand lamp FEMW-3100/1100 This items are diffusion light 360 times, so work by darkness is also possible FEMW-3100 type adopts the electronic starter system, and is maintenance as well as instant lighting up of fluorescent lamp-free (for FEMW-1100, Grosz starter system). It is the safety design where as for FEMW-3100 type the protection network works at the time of final period of the fluorescent lamp and automatically cuts off the illumination circuit. Because and, the substance in the aluminum alloy which is superior in corrosion-resistant characteristic, is superior even in waterproof characteristic, in order to withstand also coast area and the use of the outside, we are designed. Also lamp life approximately 5 times and being economic in comparison with the incandescent lamp, the hexagonal wrench (the accessory) with 1 it can make the exchange of the fluorescent lamp simple. Standard Specification Aluminum Alloy Casting Please be sure to read the following item to have use it safely. The lamp for exchange please use a designated thing. There are 50Hz and 60Hz for the power supply frequency, so when ordering, please designate it. The cable retreat section packing has inside diameter 17,(3RNCT3 core 2mm 2 suitable) 226

07 Flameproof rotary warning light IECW-1116 This item small size per minute sends the spark of 120 times with the revolution of the parabolic reflector, at once it can watch even from the distance. The glove is designed to be dual structure, as for those of the especially outer part mechanical strength is strong because the hard glass is used, furthermore for the guard attaching of the stainless steel make the degree of safety for destruction is high, the gas whose explosiveness such as complex chemical paint construction is high, is optimum to the use on the site where it occurs. Standard Specification 07 227

07 Explosion-proof portable electric light becomes In IEC protective class IP66, because the fluorescent resin is used in the front ring section which equipped the side lamp which can do, to illuminate wide scope on the side, and completely in addition to the front high brightness halogen lamp which is not problem in inspection job in the rain, is twin light/write change system, you can discover directly in the darkness. Please do a battery exchange at non-dangerous location using a special tool. In Zone 0 can not use. The type of battery that can be incorporated 228

08 Junction BoxEnclosure SXTB-04/06 Standard Specification Standard Brand SXTB-04 Standard Brand SXTB-06 08 231

08 Junction BoxEnclosure STH-1 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 232

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STH-3 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 233

08 Junction BoxEnclosure STH-5 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 234

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STH-6 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 235

08 Junction BoxEnclosure STH-7 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 236

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ASTH-10 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 237

08 Junction BoxEnclosure ASTH-20 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 238

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ASTH-30 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 239

08 Junction BoxEnclosure ASTH-60 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 240

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T ASTH-70 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 241

08 Junction BoxEnclosure ASTH-90 Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 242

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-1 Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 243

08 Junction BoxEnclosure SXTB-2AB AB side opening SXTB-2CB B side opening Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 244

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-3AB AB side opening SXTB-3CB B side opening Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 245

08 Junction BoxEnclosure SXTB-4AB AB side opening SXTB-4CB B side opening Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 246

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-5AB AB side opening SXTB-5CB B side opening Standard Specification Standard Brand 08 Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 247

08 Junction BoxEnclosure SXTB-75B B side opening Standard Specification Standard Brand Maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 248

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-200- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification 08 Standard Brand 249

08 Junction BoxEnclosure SXTB-300- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification Standard Brand 250

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-400- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification 08 Standard Brand 251

08 Junction BoxEnclosure SXTB-500- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification Standard Brand 252

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXTB-600- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification 08 Standard Brand 253

08 Junction BoxEnclosure SXTB-800- basic type Junction Box Enclosure All Open Type A.B side Open Type B side Open Type All Close Type Standard Specification Standard Brand 254

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T DA211 JUNCTION BOX ENCLOSURE 08 Terminal maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 255

08 Junction BoxEnclosure DA231 JUNCTION BOX ENCLOSURE Terminal maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 256

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T DA261 JUNCTION BOX ENCLOSURE Terminal 08 maximum number of Hubs (In case using our E1WF, E1TF, A2F, SXE) 257

08 CableGlands E1WF/ Standard Specification Substance material Pressure resistant packing material Surface treatment Brass Entry Thread(MGNPT) Entry Thread size Chloroprene Rubber Nickel electroplating Kind of packing (2:Standard size of CR 3:Standard size of Si 4:Special size of CR 7:Special size of Si) Gland material (N:Brass S:SUS304 U:SUS316 L:SUS316L) basic type 258

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 259

08 CableGlands E1TF/ Standard Specification Substance material Pressure resistant packing material Surface treatment Brass Entry Thread(MGNPT) Entry Thread size Chloroprene Rubber Nickel electroplating Kind of packing (2:Standard size of CR 3:Standard size of Si 4:Special size of CR 7:Special size of Si) Gland material (N:Brass S:SUS304 U:SUS316 L:SUS316L) basic type 260

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 261

08 CableGlands A2F/ Standard Specification Substance material Pressure resistant packing material Surface treatment Brass Chloroprene Rubber Nickel electroplating Entry Thread(MGNPT) Entry Thread size Kind of packing (2:Standard size of CR 3:Standard size of Si 4:Special size of CR 7:Special size of Si) Gland material (N:Brass S:SUS304 U:SUS316 L:SUS316L) basic type 262

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 263

08 CableGlands SXE/ Standard Specification Substance material Pressure resistant packing material Surface treatment Brass Entry Thread(MGNPT) Entry Thread size Chloroprene Rubber Nickel electroplating Kind of packing (2:Standard size of CR 3:Standard size of Si 4:Special size of CR 7:Special size of Si) Gland material (N:Brass S:SUS304 U:SUS316 L:SUS316L) basic type 264

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 265

08 Accessories SAX 266

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 267

08 Accessories SRX 268

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T 08 269

08 Accessories 270

08 Conduit Hub SXCH- Material (C:Brass S:Stainless steel) Entry Female Thread size Entry Male Thread size basic type 08 271

08 Close up Plugs EXBP- Entry Male Thread size basic type Standard Specification Material Surface treatment Brass, Steel, Stainless steel Nickel electroplating 272

08 Accessories Standard Specification Substance material PVC Standard Specification Substance material Standard Specification Substance material Standard Specification Substance material Standard Specification Substance material 08 273