Broadcom PCI Express NIC Installation

Similar documents
Broadcom PCI Express NIC Installation

PCI Express Graphics Products

Diskette Drive Installation

Diskette Drive Installation

Microsoft Word - PrivateAccess_UM.docx

Broadcom NetXtreme® Gigabit Ethernet Plus ネットワーク インタフェース カードの取り付け

ドライバインストールガイド

NSR-500 Create DVD Installer Procedures

fx-9860G Manager PLUS_J

FTDI Driver Error and Recovery Procedure Check FTDI driver operation Rev :OK, Rev :NG, Rev :NG May 11, 2017 CHECK FTDI DRIVER

Z400/Z600 WinXP 64bitマニュアルインストール手順(SATA)ver2

HP User Manual for the Integrated Intel SATA RAID Controller for Microsoft Windows XP Professional and Windows 2000 Profess...

発行 20XX年XX月XX日

ソフトウェアの更新ユーザーガイド

Z200/Z200SFF WinXP 64bit マニュアルインストール手順書

NSR-500 Installation Guide

発行 20XX年XX月XX日

TOOLS for UR44 Release Notes for Windows

Z800 WinXP 64bitマニュアルインストール手順(SATA)ver2

Red Hat Enterprise Linux 6 Portable SUSE Linux Enterprise Server 9 Portable SUSE Linux Enterprise Server 10 Portable SUSE Linux Enterprise Server 11 P

Z400/Z600 WinXP 64bitマニュアルインストール手順(SAS)ver3

Microsoft Windows XP Professional x64 Editionインストール方法説明書

発行 20XX年XX月XX日

HP Remote Graphics Software Receiver and Sender Installation Guide

Creative Sound Blaster Audigy 2 ZS

Microsoft Word - Win-Outlook.docx

Actual ESS Adapterの使用について

xwX600 シリーズWindowsXP 64bit SAS マニュアルインストール手順

Quad port LANカード(10GBASE-T) 取扱説明書

xwX600 シリーズWindowsXP 32bit SAS マニュアルインストール手順

2

untitled

Z220 WinXP 32bit SATA マニュアルインストール手順書

2

Z420-Z620 WinXP 32bit SATA マニュアルインストール手順書

LANカード(PG-2871) 取扱説明書

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE



Z220 WinXP 64bit SATA マニュアルインストール手順書

Warnings and cautions WARNING! Any surface or area of the equipment marked with this symbol indicates the presence of a hot surface or hot component.

HP Server tc2120 Microsoft Windows 2000 Server SP3 HP P

untitled

Introduction Purpose This training course describes the configuration and session features of the High-performance Embedded Workshop (HEW), a key tool

2

2

H8000操作編

Z420-Z620 WinXP 64bit SATA マニュアルインストール手順書

Creative Sound Blaster Audigy 2 ZS Quick Start Guide

Creative Sound Blaster Audigy 2 ZS クイック スタート ガイド

NVR Standard HAW-S 2017-R2 Version-up installation manual

LSI MegaRAID SAS Device Driver Installation Guide - 日本語

Yamaha Steinberg USB Driver Release Notes for Mac

NSR-500 Software Update Installation Procedures

はじめに このドキュメントではftServerに関する障害調査を行う際に 必要となるログ データの取得方法を説明しています ログ データの取得には 初期解析用のデータの取得方法と 詳細な調査を行うときのデータ取得方法があります 特別な理由でOS 側のログが必要となった場合には RHELログの取得につ

Introduction Purpose This training course demonstrates the use of the High-performance Embedded Workshop (HEW), a key tool for developing software for


HP ThinUpdateを使用したWESシンクライアントイメージリストア手順書

Adaptec SCSI RAID 2120S Controller QUick Install Guide

Quad port LANカード(10GBASE) 取扱説明書

AMT機能セットアップガイド


PCI Express Sound Blaster X-Fi Titaniumオーディオ カードの取り付け

SSR2011 検証済みドライバ一覧

8x60w Mobile WS WinXP 32/64bit マニュアルインストール手順書

UCS M シリーズ サーバでの Redhat/CentOS オペレーティング システムのインストール

Microsoft Word - 3Ware_RaidManual.doc

ダウンロード方法 アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類が あります.tar フォーマットのソフトウェアとデバイス ファイルがバンドルされたセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストール

getstart.book

BESR2010 検証済みドライバ一覧

NSR-500 Create USB Installer Procedures


Linux のインストール

19_22_26R9000操作編ブック.indb

Flash Loader

Microsoft Word - DWR-S01D_Updater_取扱説明書_120514A.doc

Dell System Services and Diagnostic Tools Version 7.0 クイックインストールガイド

セットアップカード

警告および注意 警告! 装置の表面または領域にこの記号が貼付されている場合は 高温の表面または高温の部品が存在することを示しています この表面に触れると 火傷をするおそれがあります 高温の部品による火傷の危険を防ぐため 必ず 表面の温度が十分に下がってから手を触れてください 警告! 装置の表面または


HA8000シリーズ ユーザーズガイド ~BIOS編~ HA8000/RS110/TS10 2013年6月~モデル

z230/z440/z640/z840用Thunderbolt2 Card セットアップ手順書

L3 Japanese (90570) 2008

Z7000操作編_本文.indb

Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. Windows は米国 Microsoft Corporation の米国およびその他の国における登録商標です 本書の内容は 将来予告なしに変更されることがあります HP 製

入学検定料支払方法の案内 1. 入学検定料支払い用ページにアクセス ポータルの入学検定料支払いフォームから 入学検定料支払い用 URL の ここをクリック / Click here をクリックしてください クリックを行うと 入学検定料支払い用のページが新たに開かれます ( 検定料支払い用ページは ポ

Technische Beschreibung P82R SMD

ソフトウェアインストールガイド v

N manual_JP.PDF

Microsoft Word - PCET10-CL_02a†iWinNT40_PDFŠp†j.doc

Yamaha Steinberg FW Driver for Mac Release Notes

DWR-S01D Updater 取扱説明書 発行日 :2011/2/28

V-SFTのインストール及び画面データの転送手順 V-SFT Installation and Screen Data Transfer Procedure

ダウンロード方法 アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類があります.tar フォーマットのソフトウェアとデバイス ファイルがバンドルされたセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストールす

2 3

Bluetoothお使いになる前に

HP SkyRoom のハードウェアとソフトウェアのインストール

ダウンロード方法アルテラのソフトウェアをインストールするためのダウンロード ファイルには以下の種類があります.tar フォーマットのソフトウェアとデバイス ファイルの完全なセット ダウンロードとインストールをカスタマイズするための個別の実行ファイル ディスクに焼いて他の場所にインストールするための

Microsoft Word - KUINS-Air_W10_ docx

Report Template

Transcription:

Broadcom PCI Express NIC Installation This document describes how to install a Broadcom Network Interface Card (NIC) into a PCI Express slot on your workstation. This card uses the third-generation (3GIO) PCI Express hardware interconnect standard. PCI Express, the successor of the PCI, PCI-X, and AGP I/O standards, delivers greater bandwidth and performance using a point-to-point high-speed serial link technology. PCI Express architecture is stable, scalable, and extensible. Installing your PCI Express NIC Hardware To install your PCI Express card: 1. If you have Internet access, download the latest BIOS and driver updates from the support Web site for your workstation at www.hp.com/support/workstationsupport. NOTE: If you will not have Internet access until after installing the network card, you can download the latest BIOS and driver updates later. 2. After installing the updates, disconnect power from the system, remove the hood cover, and lay the workstation on its side with the system board facing up. 3. If necessary, remove any card hold downs. Refer to the next page for examples of hold downs. 4. Release the PCI levers by first pressing down on them and then out 1. 5. If necessary, remove the applicable PCI slot cover 2. NOTE: The following illustration shows a typical installation. Refer to the illustration on the inside of the access panel for the PCI Express slot location on your HP Workstation. 1 2 3 4 6. Install the PCI Express card 3. Verify that the keyed components of the card align with the socket. 7. Close the PCI levers 4. 1

8. If your card has a hold down, install it to limit the movement of the card when the workstation is being moved. The following illustrations show the installation of some typical card hold downs. Installing your PCI Express NIC Software Microsoft Windows NOTE: For more information on setting up the PCI Express NIC card, see the Broadcom User s Guide that is located on the enclosed CD. 1. Insert the enclosed CD into a CD-ROM drive. Your computer detects the presence of the CD and displays the menu from the CD. 2. To find information on the HP NetXtreme Gigabit Controller by HP and its capabilities, click User s Guide. 2

3. To install the Broadcom Advanced Control Suite, click Advanced Control Suite and follow the on-screen instructions. 4. Install the Broadcom driver: If you can access the Internet, go to the HP Support Web site at www.hp.com/go/workstationsupport and download the latest Broadcom network driver. If you cannot access the Internet, install the Broadcom driver software from this CD, click Browse CD Contents, select the DRVINST folder, double-click the Setup.exe file and follow the on-screen instructions. NOTE: A more recent version of the Broadcom driver might be available on the HP Support Web site, which is available at www.hp.com/go/workstationsupport. NOTE: When HP begins shipping Microsoft Windows XP Professional x64 Edition, the 64-bit Broadcom driver will be available on the Web as a softpaq. If you need 64-bit support and this driver is not on the CD provided, please download and install this softpaq. Linux To to use the BCM5751 NIC with Red Hat Enterprise Linux WS 3, perform the following steps: 1. Go to www.hp.com/go/workstationsupport. 2. Select your workstation. 3. In the I would like to section, click download drivers and software. 4. In the select operating system section, click Red Hat Enterprise Linux 3 (x86) or Red Hat Enterprise Linux 3 (AMD64/EM64T). 5. In the quick jump to downloads by category... section, click Software. 6. Locate HP Installer Kit for Linux - Red Hat Driver Disk for Red Hat Enterprise that is dated 16 Feb 2005 with revision Update 2 Rev. A and click obtain software. 7. Read the agreement and click I Agree to proceed. 8. Save the file, RedHat_TG3_driver_disk.tgz, to a directory on your hard drive. 9. Unpack the file with tar xvfz RedHat_TG3_driver_disk.tgz, which will uncompress and upack three files - RedHat_TG3_driver_disk.iso, tg3-2.4.21-15.1-2.i386.rpm, and tg3-2.4.21-15.1-2.x86_64.rpm. 10. You can either install the rpm appropriate for your architecture, or burn the.iso file to a CD and use it as a Driver Disk during the installation process. 11. Install the rpm: For x86: rpm -ivh tg3-2.4.21-15.1-2-i386.rpm For AMD64/EM64T: rpm -ivh tg3-2.4.21-15.1-2-x86_64.rpm 12. Notice that you now have an entry in /etc/modules.conf: Alias eth<#> tg3 # Added by tg3 RPM 13. Reboot the system and kudzu finds and allows you to configure the new Generic tg3 device as desired. 3

1000 100 10 ACT 14. To use the Driver Disk during the installation process, begin the installation with boot: linux dd and follow the installation instructions. NIC LED behaviors The faceplate on the 10/100/1000BASE-T NIC provides an RJ-45 connector for connecting the NIC to another network device. The NIC has four LEDs, one for each port speed option (10 Mbps, 100 Mbps, and 1000 Mbps), and one for ACT (activity). The three port speed LEDs indicate active links, and the ACT LED indicates data transfer status. After the NIC is installed and the cables are connected properly, the appropriate speed LED is lit and the ACT LED is on if data traffic is present. The following table describes the LED states: LED State Description 1000 ON 1000-Mbps Ethernet link. OFF No 1000-Mps link. There might be link at a different speed, a bad cable or connector, or a configuration mismatch. 100 ON 100-Mbps Ethernet link. OFF No 100-Mps link. There might be link at a different speed, a bad cable or connector, or a configuration mismatch. 10 ON 10-Mbps Ethernet link. OFF No 10-Mps link. There might be link at a different speed, a bad cable or connector, or a configuration mismatch. ACT Blinking Brief bursts of data are detected on the port. ON OFF Streams of data are detected on the port. No data is detected on the port. 4

Broadcom PCI Express NIC のインストール 本書では Broadcom ネットワークインターフェースカード (NIC) をお使いのワークステーションの PCI Express スロットにインストールする方法について説明します このカードは 第 3 世代 (3GIO) PCI Express ハードウェア相互接続規格を採用しています PCI Express は PCI PCI-X および AGP I/O の後継規格です PCI Express は 1 対 1 接続の高速シリアルリンク技術を使用して 広帯域 高性能を実現しています PCI Express アーキテクチャは 安定性 スケーラビリティ 拡張性に優れています PCI Express NIC ハードウェアのインストール PCI Express カードのインストールは 以下の手順で行います 1. インターネットに接続している場合は お使いのワークステーション用の最新の BIOS とドライバのアップデートを 次のサポート Web サイトからダウンロードします www.hp.com/go/workstationsupport ( 英語 ) 注記 : ネットワークカードをインストールしないとインターネットに接続できない場合は 後から最新の BIOS とドライバのアップデートをダウンロードできます 2. アップデートをインストールした後 システムの電源を切断し フードカバーを取り外し システムボードが上を向くよう ワークステーションの側面を下にして置きます 3. 必要に応じて カードホールドダウンを取り外します カードホールドダウンの例は 次のページを参照してください 4. PCI レバーを押し下げてから外に開き レバーを解除します 1 5

5. 必要に応じて PCI スロットのカバーを取り外します 2 注記 : 以下の図は 標準的なインストール例を示します お使いの HP ワークステーションの PCI Express スロットの位置については アクセスパネル内部の図を参照してください 1 2 3 4 6. PCI Express カードをインストールします 3 カードの固定されたコンポーネントが ソケットと合っているか確認します 7. PCI レバーを閉じます 4 6

8. お使いのカードにホールドダウンが付属している場合 ワークステーションを移動する際にカードがずれないよう ホールドダウンでカードを固定してください 以下の図に ホールドダウンの標準的な使用例を示します PCI Express NIC ソフトウェアのインストール Microsoft Windows 注記 : PCI Express NIC カードのセットアップの詳細については 付属の CD に収録されている Broadcom User's Guide を参照してください 1. 付属の CD を CD-ROM ドライブに挿入します コンピュータが CD の存在を検出して CD のメニューを表示します 7

2. HP NetXtreme Gigabit Controller についての情報や機能を確認するには [User's Guide] をクリックします 3. Broadcom Advanced Control Suite をインストールするには [Advanced Control Suite] をクリックして画面に表示される指示に従います 4. Broadcom ドライバをインストールするには 以下の手順を行います インターネットに接続できる場合は 次の HP サポート Web サイトから 最新の Broadcom ネットワークドライバをダウンロードします www.hp.com/go/workstationsupport ( 英語 ) インターネットに接続できない場合は Broadcom ドライバソフトウェアをこの CD からインストールします [Browse CD Contents] をクリックし [DRVINST] フォルダを選択し Setup.exe ファイルをダブルクリックして 画面に表示される指示に従います 注記 : Broadcom ドライバの最新のバージョンは 次の HP サポート Web サイトから利用できます www.hp.com/go/workstationsupport ( 英語 ) 注記 : Microsoft Windows XP Professional x64 Edition 出荷開始時点では Web 上で Broadcom の 64 ビットドライバを softpaq として入手することができます 64 ビット対応ドライバが必要で 付属の CD にそのドライバがない場合 本 softpaq をダウンロードし インストールしてください Linux BCM5751 NIC を Red Hat Enterprise Linux WS 3 で使用するには 以下の手順を行います 1. www.hp.com/go/workstationsupport ( 英語 ) にアクセスします 2. お使いのワークステーションを選択します 3. [I would like to] セクションで [download drivers and software] をクリックします 4. [select operating system] セクションで [Red Hat Enterprise Linux 3 (x86)] または [Red Hat Enterprise Linux 3 (AMD64/EM64T)] をクリックします 5. [quick jump to downloads by category...] セクションで [Software] をクリックします 6. 日付が [16 Feb 2005] でリビジョンが [Update 2 Rev. A] の [HP Installer Kit for Linux - Red Hat Driver Disk for Red Hat Enterprise] を確認して [obtain software] をクリックします 7. 同意内容を読み [I Agree] をクリックして続行します 8. ハードドライブ上のディレクトリに RedHat_TG3_driver_disk.tgz ファイルを保存します 9. tar xvfz RedHat_TG3_driver_disk.tgz を入力して ファイルを解凍します RedHat_TG3_driver_disk.iso tg3-2.4.21-15.1-2.i386.rpm tg3-2.4.21-15.1-2.x86_64.rpm の 3 つのファイルが作成されます 10. お使いのアーキテクチャに対応する rpm をインストールするか または.iso ファイルをCD にコピーしてインストール処理中にドライバディスクとして使用することができます 11. 以下を入力して rpm をインストールします x86 の場合 : rpm -ivh tg3-2.4.21-15.1-2-i386.rpm AMD64/EM64T の場合 : rpm -ivh tg3-2.4.21-15.1-2-x86_64.rpm 8

1000 100 10 ACT 12. /etc/modules.conf に 以下のエントリがあることを確認します Alias eth<#> tg3 # Added by tg3 RPM 13. システムを再起動して kudzu で新しい Generic tg3 device を構成できるようにします 14. インストール処理中にドライバディスクを使用する場合 boot: linux dd を指定してインストールを開始し インストール指示に従ってください NIC LED の動作 10/100/1000BASE-T NIC のフェイスプレートには NIC を他のネットワークデバイスに接続する RJ-45 コネクタがあります NIC には 4 つの LED があり それぞれ各ポート速度オプション (10 Mbps 100 Mbps 1000 Mbps) と ACT ( 動作 ) に対応しています 3 つのポート速度 LED は 稼働中のリンクを示し ACT LED はデータ転送ステータスを示します NIC をインストールした後にケーブルを正しく接続すると 該当する速度の LED が点灯し データ転送がある場合は ACT LED が点灯します 以下の表では LED のステータスを説明します LED 状態説明 1000 点灯 1000 Mbps のイーサネットリンクあり 消灯 1000 Mps のリンクなし 他の速度でのリンクが存在するか ケーブルまたはコネクタが不良か 構成が不適切です 100 点灯 100 Mbps のイーサネットリンクあり 消灯 100 Mps のリンクなし 他の速度でのリンクが存在するか ケーブルまたはコネクタが不良か 構成が不適切です 10 点灯 10 Mbps のイーサネットリンクあり 消灯 10 Mps のリンクなし 他の速度でのリンクが存在するか ケーブルまたはコネクタが不良か 構成が不適切です ACT 点滅ポートでデータの短いバーストが検出されています 点灯 消灯 ポートでデータストリームが検出されています ポートでデータが検出されていません 9

2004-2005 Hewlett-Packard Development Company, L.P. The HP Invent logo is a registered trademark of Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Linux is a U.S. registered trademark of Linux Torvalds. 377598-003 10