Microsoft Word - SQ8_製品仕様書_E

Similar documents
Microsoft Word - SL4_製品仕様書_E

Basic Specification for MT4 Series Rated currents Your part number SOC product Rated Your part SOC product Rated Remarks name currents number name cur

Basic Specification for ET Series Rated currents Your part number SOC product Rated Your part SOC product Rated Remarks name currents number name curr

Basic Specifications for MCFA Series Rated currents Packaged on tape Your part No. SOC product name Rated current Packaged in a plastic bag Your part

Microsoft Word - PCM TL-Ed.4.4(特定電気用品適合性検査申込のご案内)


Tab 5, 11 Tab 4, 10, Tab 3, 9, 15Tab 2, 8, 14 Tab 1, 7, 13 2

alternating current component and two transient components. Both transient components are direct currents at starting of the motor and are sinusoidal

利隆塑料

内蔵ハードディスクユニット-20GB (PG-HD2E4H) 内蔵ハードディスクユニット-40GB (PG-HD4E4H)取扱説明書 HARD DISK DRIVE 20GB(PG-HD2E4H) HARD DISK DRIVE 40GB(PG-HD4E4H) USER'S GUIDE

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T STW Symbol Symbol otary switch) 05 otary switch Symbol angle of notch 181

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

IEC :2014 (ed. 4) の概要 (ed. 2)

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

ユーザーズマニュアル

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T box number basic type Standard Specification Material of Enclosure Material of F

Description

Huawei G6-L22 QSG-V100R001_02

How to read the marks and remarks used in this parts book. Section 1 : Explanation of Code Use In MRK Column OO : Interchangeable between the new part

LC304_manual.ai

- 1 -

WARNING To reduce the risk of fire or electric shock,do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabi

2

2

MKS-05 "TERRA-Pプラス 日本語訳取扱説明書

2

I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility Fro

H8000操作編

2

Z7000操作編_本文.indb


: (20ºC +/- 5ºC) : : 3 : : RV Bose Corporation hereby declares that this product is in compliance with the essential requirements and other relevant p

Fig. 1 Schematic construction of a PWS vehicle Fig. 2 Main power circuit of an inverter system for two motors drive

March 8, 2011 March 8,




Tornado Series selection SW TiCN HSS Co FAX VL PM


メタルバンドソー

クイックスタートガイド [SC-03E]



i5 Catalyst Case Instructions JP

Direct Motor Drive Lead Screws / Resin Lead Screw type RM / RM RM Resin Lead Screw type RM / Resin MoBo 2 MRH 2 Features A 2-phase Stepping Motor is m

PC_14ZY6_BFT150A_US_ indd

FreeSpace.book

137. Tenancy specific information (a) Amount of deposit paid. (insert amount of deposit paid; in the case of a joint tenancy it should be the total am

DZ-GX20/DZ-MV780取扱説明書(上巻)


32C2100操作編ブック.indb


MIDI_IO.book

1 2 3

19_22_26R9000操作編ブック.indb

untitled


00_1512_SLIMLINE_BOOK.indb

Mitsubishi FR-BAL Manual

1. Database&Logic Word/Excel/PPT/PDF&Web Ultimate Dictionary 4. Jukkou&Rewrite 5. Convenience&Safety 6. Chinese&Korean 7. Support&Consultation 8

/ Motor Specifications Direct Motor Drive Ball Screws / Precision Ball Screw type MB / MB MB Precision Ball Screw type MB / MoBo C3 5 5 Features A 5-p

音響部品アクセサリ本文(AC06)PDF (Page 16)

DZ-HS503 取扱説明書

DZ-GX3300/GX3100/GX3100取扱説明書

DZ-HS303 取扱説明書

52-2.indb

cms.pdf

PowerPoint プレゼンテーション

ユーザーズマニュアル

LM35 高精度・摂氏直読温度センサIC

Agilent 4339B High Resistance Meter Operation Manual

Motivation and Purpose There is no definition about whether seatbelt anchorage should be fixed or not. We tested the same test conditions except for t


03-01 Senyouki.pdf

2

JIS A 5308 a1 moll moll moll (JP) REAGENT CHEMICALS ninth edition ACS SPECIFICATIONS Replication Duplicate standardiz

JOURNAL OF THE JAPANESE ASSOCIATION FOR PETROLEUM TECHNOLOGY VOL. 66, NO. 6 (Nov., 2001) (Received August 10, 2001; accepted November 9, 2001) Alterna

Specification for Manual Pulse Generator, GFK-2262

2 3

スプリングプローブコネクタ、ライトアングルコネクタ

植物23巻2号

fx-9860G Manager PLUS_J

クイックスタートガイド [SC-06D]

インターネット接続ガイド v110

untitled

untitled

Options Unit : mm Finger guards Color Model Surface treatment Nickel-chrome plating silver DC Fan 4mm Air Flo

Bull. of Nippon Sport Sci. Univ. 47 (1) Devising musical expression in teaching methods for elementary music An attempt at shared teaching

untitled

OPERATING INSTRUCTION RNTD Model NTD Model To the use r In order to use the torque driver properly and safely,please read the instructions before oper

Microsoft Word - CDEIR10D50ME_Ver1.0_E.docx

Options(Unit : mm) Finger guards Model :19-139E :19-139H 53 Surface treatment :Nickel-chrome plating (silver) :Cation electropainting (black) Inlet si

pc725v0nszxf_j

untitled

*1 *2 *1 JIS A X TEM 950 TEM JIS Development and Research of the Equipment for Conversion to Harmless Substances and Recycle of Asbe

FC741E2_091201

パナソニック技報

P3FY J E

Transcription:

Basic Specification for SQ8 Series SOC product name SQ8 Rated current Certification UL198G Listed Rated currents ma 3 A CSA C22.2 No. 59.2 Certified Rated currents ma 3 A Dimensions and construction End-cap (Nickel plated brass) 14±1 4.0±0.2 Solder 1 2 φ4.6±0.15 Fuse-element Glass-tube (mm) Marking Marking 1: SOC SQ8 Marking 2: 125V Rated current Electrical characteristics Certification Rated voltage Rated current (I N ) UL CSA AC 125 V ma 3 A 00 A Rated breaking current PF= 0.7 0.8 Temperature rise Not more than 70 K at 1.1 I N Current carrying capacity 1.1 I N for not less than 15 min after temperature stabilization. Overload operation Within min at 1.35 I N Within 2 min at 2.0 I N Rated currents Your part number SOC product name Rated Rated Your part number SOC product name currents currents SQ8 ma ma SQ8 1A 1 A SQ8 250mA 250 ma SQ8 1.25A 1.25 A SQ8 315mA 315 ma SQ8 2A 2 A SQ8 400mA 400 ma SQ8 2.5A 2.5 A SQ8 500mA 500 ma SQ8 3A 3 A Environment-related substances The six hazardous substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE)) specified in the EU RoHS Directive are not used intentionally in this product. This product conforms to the EU RoHS Directive 2011/65/EU. Lead content as impurities is not more than 0.1 wt%. The information in this specification shall be subject to change without notice. June 17, 2015

Safety Precautions When Selecting and Using Fuses WARNING: Read and follow these precautions before selecting and using fuses. Failure to properly select, install, and use fuses can result in serious injury, death, or property damage. Before final fuse selection, always test the proposed fuse in your actual equipment to ensure that the fuse satisfies all your operational and safety requirements. Use the fuses within the specification requirements. Exceeding specification requirements may result in injury, death, or fire. Do not use the fuse where it is exposed to high humidity, and corrosive and flammable gases. Doing so may result in nuisance operations, disconnection of the fuse-element, or explosions. Shut down the power before touching the fuse. Failure to do so may result in electrocution or serious burns. Do not apply ultrasonic cleaning to the fuse. Ultrasonic cleaning may result in disconnection of the fuse-element. AC 30V DC Be aware that the breaking ability of a fuse will differ depending on whether the circuit is an AC or a DC circuit. Fuses intended for use in AC circuits should therefore not be employed in DC circuits, and vice versa, as this may result in accidents such as explosions, property damage, and serious injury. Check if the circuit voltage is large enough for fuse operation. When the circuit voltage is too small, the fuse may not operate even though an abnormal current passes through it as the current decreases due to the increase of the fuse resistance. Do not form the lead when the temperature of the fuse is greater than or equal to 40 C. Lead forming at these temperatures may result in disconnection of the fuse-element as the load is applied to it. Do not apply coating or potting to the fuse. Doing so may result in disconnection of the fuse-element or a change in the fuse s characteristics. Use sample fuses only for evaluation. Do not reuse fuses. Properly dispose of used fuses. Consider the effect of the ambient temperature when you use the fuse. The electrical performance of the fuse may vary depending on the temperature. When inserting a fuse into a fuseholder, avoid applying excessive force as this may result in the fuse cracking or contact failure which will significantly reduce its ability to work properly or shorten its life. Use the fuse in a place where the vibration and impact levels are within the specified limits. Exceeding these limits may result in disconnection of the fuse-element. When the fuse is used for a life support system or equipment that requires high reliability, examine and evaluate the fuse in actual circuit conditions more carefully than is necessary for other general electronic equipment.

FOR REFERENCE ONLY ( ご参考 ) I-t Curve この I-t 特性図は 弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります 参考値であり保証値ではありません ヒューズの特性はその使用条件により変化しますので お客様にヒューズのご使用条件下で ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります This I-t curve is a plot of the average values of the measurements obtained under conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values. The characteristics of the fuse may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Type: SQ8 Control No.: 130610 10A 電流 Current 1A 3 A 2.5 A 2 A 1.25 A 1 A 500 ma 400 ma 315 ma 250 ma 0.1A ma 10ms ms 1s 10s s 溶断時間 Pre-arcing time SOC Corporation

I 2 t-t Curve FOR REFERENCE ONLY ( ご参考 ) この I 2 t-t 特性図は 弊社が試験条件を特定して測定した実測値の平均値だけをプロットしてあります 参考値であり保証値ではありません ヒューズの特性はその使用条件により変化しますので お客様にヒューズのご使用条件下で ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります This I 2 t-t curve is a plot of the average values of the measurements obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values. The characteristics of the fuse may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Type: SQ8 Control No.: 130610 I 2 t 10A 2 s 1A 2 s 0.1A 2 s 3 A 2.5 A 2 A 1.25 A 1 A 500 ma 400 ma 315 ma 250 ma ma 0.01A 2 s 1E-3A 2 s 1ms 10ms ms 1s Time SOC Corporation

FOR REFERENCE ONLY ( ご参考 ) 周囲温度の影響 - 定格電流値のリレーティング Influence of Ambient Temperature - The Re-rating of the Rated Current この周囲温度に対する定格電流の変化を示すグラフは 周囲温度 40 C 25 C 及び 85 C に於いて弊社が特定した条件で測定した 3 点の実測値であり お客様での実使用条件を考慮したものではありません ヒューズの特性はその使用条件により変化しますので お客様にヒューズのご使用条件下で ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります This chart is a plot of the measurements obtained at the ambient temperatures of 40 C, 25 C and 85 C under conditions specified by SOC. The conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Type: SQ8 ma Control No.: 110113 Type: SQ8 250mA Control No.: 130117 Type: SQ8 315mA Control No.: 130117 - -40-20 0 20 40 - -40-20 0 20 40 - -40-20 0 20 40 Type: SQ8 400mA Control No.: 130117 Type: SQ8 500mA Control No.: 130117 Type: SQ8 1A Control No.: 130117 - -40-20 0 20 40 - -40-20 0 20 40 - -40-20 0 20 40 SOC Corporation

FOR REFERENCE ONLY ( ご参考 ) 周囲温度の影響 - 定格電流値のリレーティング Influence of Ambient Temperature - The Re-rating of the Rated Current この周囲温度に対する定格電流の変化を示すグラフは 周囲温度 40 C 25 C 及び 85 C に於いて弊社が特定した条件で測定した 3 点の実測値であり お客様での実使用条件を考慮したものではありません ヒューズの特性はその使用条件により変化しますので お客様にヒューズのご使用条件下で ヒューズがお客様のご要求を満足しているかを実際にご確認頂く必要があります This chart is a plot of the measurements obtained at the ambient temperatures of 40 C, 25 C and 85 C under conditions specified by SOC. The conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Type: SQ8 1.25A Control No.: 130117 Type: SQ8 2A Control No.: 130117 Type: SQ8 2.5A Control No.: 130117 - -40-20 0 20 40 - -40-20 0 20 40 - -40-20 0 20 40 Type: SQ8 3A Control No.: 130117 Type: MQ2 4AN1 Control No.: 130117 Type: MQ2 5AN1 Control No.: 130117 - -40-20 0 20 40 SOC Corporation

Technical Specifications for SQ8 Series 1. Construction Insulating tube: Lead-free glass Fuse-element End-cap: Nickel plated brass Solder: 1 A or less (Sn-0.7Cu) 1.1 A 3 A (Sn-3.0Ag-0.5Cu) Adhesive: Epoxy resin 2. Usage conditions Ambient temperature: 40 C +85 C Note: The current carrying capacity of the fuse may vary depending on the ambient temperature. Ambient humidity: 85% RH or less 3. Storage conditions and storage period Products packaged as delivered can be stored for one year after shipping from SOC. Ambient temperature: 30 C +40 C (No condensation) Ambient humidity: 85% RH or less Ambient atmosphere: Not exposed to corrosive gas or sea breeze. No visible dust. Not exposed to direct sunlight. Load: No application of load that may cause deformation or degradation of the product. 4. Typical cold resistance (for reference only) Rated current Typical cold Typical cold Rated current resistance resistance ma 6.4 Ω 1 A 1 mω 250 ma 1.6 Ω 1.25 A 90 mω 315 ma 1.1 Ω 2 A 65 mω 400 ma 750 mω 2.5 A 45 mω 500 ma 465 mω 3 A 38 mω The information in this specification shall be subject to change without notice. June 18, 2015

Packaging Specifications for SQ8 Series 1. Fuses to be delivered shall be packed as follows: (1) 1,000 fuses are packed into a colorless transparent polyethylene bag. (2) An identification label is attached to each bag. (3) Each bag of 1,000 fuses is packed into the cardboard case shown in the figure below. If the number of fuses to be packed in is less than 1,000, the fuses are still packed into the case in the same manner. (4) The following are indicated on the surface of the cardboard case: Your part number (by request) Quantity of fuses Packaged date Country of origin Manufacturer Production facilities Indications required by the applicable standards 53 145 115 (mm) 2. Lot number The lot number indicates the following: Example: 1 5 0 1 2 3 9 1 Date manufactured (January 23, 2015) Process code The information in this specification shall be subject to change without notice. June 18, 2015