Cable Gland This is the s to use for Cable Wiring in the hazardous location. It is much easier to install and maintenance and modification compared with Conduit Wiring with Sealing Fitting. The Standard Threads are applied PF (B-class). G(A-class). Please be sure to read the following item to have use it safely without reusing. 1, The packing used once, please be sure to exchange it. The explosion protection performance can't be maintained any more. Please tighten. 2, Packing up surely. Please use something a gap inside the cable isn't so that flammable gas may be difficult to pour into. 3, A used cable (), and the cable surface is smooth and unevenness isn't and by which a section is a cylinder. There is nothing set especially with the cable it's possible to use for explosion protection construction, but CV, CVS and VCT, etc. will recommend you because there are no inner gaps. When using a Corrugated cable. Please select SXK. using a cable (Corrugated cable), please select SXK. 134
I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T Pressure-resistant gasket type retreat method effective bulk compressibility From research institute of industrial safety technical guide. Appendix 3 1.2.1 pressure-resistant single hole gasket type retreat methodological Hardness (JIS spring type hardness Hs) 45~65 Pull strength 7MPa above Extension 350% or more As for depth of the induction penetration section after the gasket tightening, when it is below the 2cm 3 according to the content volume of the container, below the ~100cm 3 above 5mm and above the 2cm 3 when above 8mm, it exceeds the 100cm 3, it makes above 12mm. Minimum of effective bulk compressibility of the gasket does 5%. 03 Table Standard angle and dimension of Threads 135
EXPC-16B28B Standard Specification Packing number size Select Packing Number 136
I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T EXBM-16B28B Packing number Standard Specification size 03 Select Packing Number 137
SXBM-16B28B Packing number size When it is below the content 2000cm 3 ExdC it is enabled. Below the content 6000cm 3 it is enabled with d3a only in case of the screw of A class. Standard Specification Select Packing Number 138
I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T SXC-16B54B SXC-16BY54BY Standard Specification Packing number Packing case without O-ring Packing case with O-ring size 03 in the drawing is BY type Select Packing Number 139
NSTPC-16104 NSTPC-16Y104Y Packing number Packing case without O-ring Packing case with O-ring R(for movement equipment) size Standard Specification in the drawing is Y type Thread size more than 70 Select Packing Number 140
I N S T R U M E N T A T I O N & E L E C T R I C A L E Q U I P M E N T CSFX-16B54B When it is below the content 2000cm 3 ExdC it is enabled. Packing number Standard Specification size 03 Select Packing Number 141
(Corrugated) SXK-1654 Standard Specification Conformity cable range number (outer) Conformity cable range number (inner) size When it is below the content 2000cm 3 ExdC it is enabled. Armoring Dia. Select Packing Number 142
SBM-16104 Standard Specification Packing number R(for movement equipment) size Standard Specification Zinc alloy die-cast 03 Thread size more than 70 Select Packing Number 143
ESBM-1622 Standard Specification Material Packing number R(for movement equipment) size Substance: Gland:Zinc alloy die-cast Select Packing Number 144