マススペクトロメトリー関係用語集

Size: px
Start display at page:

Download "マススペクトロメトリー関係用語集"

Transcription

1 IUPAC Draft Recommendation: Standard Definitions of Terms Relating to Mass Spectrometry 2 16) Da, u, ev, Pa, m/z IUPAC 6. (-) (/) LC-MS (liquid chromatograph mass spectrometer) LC/MS (liquid chromatography mass spectrometry) 7. daughter ion

2 ( ) abundance sensitivity m 1 m / m 1 m 1 accelerating voltage accelerator mass spectrometry (AMS) MeV acceptance accurate mass 1 mda ( u) measured accurate mass exact mass additivity of mass spectra 14

3 adduct ion (cationized molecule) [M NH 4 ],[M Na],[M Cl] adiabatic ionization a-ion a C C N (fragment ion) a-cleavage a- a (homolytic cleavage) analog ion (CH 3 CO ) (CH 3 CS ) analyte (fast atom bombardment) (electrospray ionization) (matrix) anion radical (radical anion) 15

4 anionized molecule anion: (pseudo-molecular ion quasi-molecular ion) (molecular-related ion) appearance energy (AE) (electron ionization) (fragment ion) (appearance potential) appearance potential (AP) (appearance energy) array detector associative ion/molecule reaction associative ionization A M atmospheric pressure chemical ionization (APCI) (chemical ionization) 16

5 atmospheric pressure ionization (API) (atmospheric pressure chemical ionization), (electrospray ionization), (liquid ionization) atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) (matrix-assisted laser desorption/ionization) atmospheric pressure photoionization (APPI) (photoionization) (atmospheric pressure chemical ionization) atmospheric pressure spray atomic mass unit (amu) (unified atomic mass unit) atomic weight (relative atomic mass) (IUPAC) (standard atomic weight) 17

6 (unified atomic mass unit) autodetachment autoionization (ionization energy) A M M M e average mass (monoisotopic mass) B/E linked scan B/E B/E B/E (linked scan at constant B/E) B[1 (E/E 0 )] 1/2 /E linked scan B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E (linked scan at constant B[1 (E/E 0 )] 1/2 /E) B 2 /E linked scan B 2 /E B 2 /E B 2 /E (linked scan at constant B 2 /E) background mass spectrum 18

7 (residual mass spectrum) base peak (BP) base peak chromatogram (base peak) (hyphenated method) bath gas (bu#er gas) b-cleavage b- b (homolytic cleavage) b-ion b C N N (fragment ion) blackbody infrared radiative dissociation (BIRD) (ion trap) (infrared multiphoton dissociation) bu#er gas (ion trap) (collision quadrupole) (collision gas) 19

8 calculated exact mass p. 40, exact mass capillary electrophoresis mass spectrometry (CE/MS) capillary-skimmer collision-induced dissociation (electrospray ionization) (collision-induced dissociation) (nozzle-skimmer collision-induced dissociation) (skimmer collision-induced dissociation) (collision-induced dissociation) (skimmer) cation radical (radical cation) cationized molecule cation (pseudomolecular ion quasi-molecular ion) (molecular-related ion) center-of-mass collision energy (collisional excitation) 1 E lab M i (collision gas) 20

9 M n E cm E cm E lab [M n /(M n M i )] 5keV 1,000 u He 19.9 ev (center-of-mass kinetic energy) (laboratory collision energy) center-of-mass kinetic energy (center-of-mass collision energy) centroid acquisition m/z (continuum acquisition) channel electron multiplier (continuous dynode electron multiplier) channeltron (continuous dynode electron multiplier) charge exchange ionization (ion/molecule reaction) charge exchange reaction (charge transfer reaction) 21

10 charge inversion mass spectrum (charge inversion reaction) m/z charge inversion reaction (precursor ion) M M (collision gas) X M M M X M X 2 M X M X e charge mediated fragmentation (fragmentation) (charge remote fragmentation) charge number 1 q e z z q/e charge permutation reaction (charge number) charge remote fragmentation (CRF) (fragmentation) [M H], [M Na] (even-electron ion) (high-energy collision-induced dissocia- 22

11 tion) (remote site fragmentation) (charge mediated fragmentation) charge stripping reaction (CSR) z M z (collision gas) M (z r) (ionizing collision) M z X M (z r) re (X s se ) charge transfer reaction (charge exchange reaction) (charge number) (ion/neutral reaction) (charge permutation reaction) (electron capture reaction) (charge stripping reaction) chemical ionization (CI) (reagent gas) [R H] X (reactant ion) M M 23

12 [R H] M [M H] R C 2 H 5 M [M H] C 2 H 6 X M [M H] HX (negative ion chemical ionization) chemi-ionization (penning ionization) (associative ionization) (chemical ionization) chromatogram (chromatography) chromatograph (chromatography) chromatography c-ion c C N N C a N (fragment ion). cleavage (homolytic cleavage) (heterolytic cleavage) (frag- 24

13 mentation) (dissociation) cluster M A B M n,a n,a n B m (n, m 2) cluster ion (cluster). M n, M n, [M n H],[M n H] collision cell (collision-induced dissociation) (collision gas) collision chamber (collision cell) collision gas (collisional excitation) (ion/molecule reaction) collision quadrupole m/z (bu#er gas) (collision gas) (quadrupole) (hybrid mass spectrometer) q EBqQ RF (RF-only quadrupole) 25

14 (ion guide) collision reaction cell (charge exchange reaction) (ion/neutral reaction) (hexapole) (octapole) (inductively coupled plasma mass spectrometry) collisional activation (CA) (collisional excitation) collisional excitation (collision gas) (center-of-mass collision energy) collisionally activated dissociation (CAD) (collision-induced dissociation) collision-induced dissociation (CID) (fragmentation) (collisionally activated dissociation) (collisional excitation) complex ion (spark source mass spectrometry) 26

15 consecutive reaction monitoring (CRM) n 3 MS n MS n constant neutral loss scan 2 (mass analyzer) (tandem mass spectrometer) (metastable ion decay) (collision-induced dissociation) (constant neutral loss spectrum) constant neutral loss spectrum m/z (precursor ion) constant neutral mass gain scan 2 (mass analyzer) (tandem mass spectrometer) (collision gas) (ion/molecule reaction) (constant neutral mass gain spectrum) constant neutral mass gain spectrum (collision gas) (ion/molecule reaction) m/z (product ion) continuous dynode electron multiplier (secondary electron) 27

16 discrete dynode electron multiplier (channel electron multiplier) (channeltron) (secondary electron multiplier) continuous flow fast atom bombardment (CF-FAB) (analyte) (fast atom bombardment) continuum acquisition (profile acquisition) (centroid acquisition) conversion dynode corona discharge Coulomb explosion (1) M z n (2) (electrospray ionization) 28

17 (Rayleigh limit) curved field reflectron R 2 V 2 x 2 x V R (reflectron) cycloidal mass spectrometer (prolate trochoidal mass spectrometer) cyclotron motion q B v qv B dalton (Da) Da SI SI (unified atomic mass unit) 10 kda, 1 MDa, 10 mda Daly detector (photomultiplier) (conversion dynode) daughter ion (product ion) 29

18 daughter ion analysis (product ion analysis) daughter ion scan (product ion scan) daughter ion spectrum (product ion spectrum) deconvolution (electrospray ionization) (multiplycharged ion) 0 delayed extraction (DE) (desorption ionization) (time-of-flight mass spectrometer) (mass resolution) delayed extraction deprotonated molecule M H [M H] (fast atom bombardment) (electrospray ionization) 30

19 Derrick shift MIKE (collision-induced dissociation) (collision gas) (precursor ion) (product ion) MIKE MIKE (mass-analyzed ion kinetic energy spectrometry) desorption chemical ionization (DCI) (in-beam chemical ionization) (in-beam method) desorption electron ionization (DEI) (in-beam electron ionization) (in-beam method) desorption electrospray ionization (DESI) (electrospray ionization) desorption ionization (DI) (field desorption) (fast atom bombardment) (matrix-assisted laser desorption/ionization) desorption ionization on silicon (DIOS) (porous silicon) 31

20 (desorption ionization) (surface-assisted laser desorption/ionization) detection limit (sensitivity) diagnostic ion (precursor ion) (product ion) (electron ionization) (diagnostic ion) di#erential pumping di#usion pump Torr 10 2 Torr dimeric ion [M 2 ] direct analysis of daughter ions (DADI) MIKE (mass-analyzed ion kinetic energy 32

21 spectrometry) direct chemical ionization (in-beam chemical ionization) (in-beam method) direct dissociation (molecular ion) direct exposure method (in-beam method) direct exposure probe (DEP) (direct insertion probe) (ionization chamber) (desorption electron ionization) (desorption chemical ionization) (direct inlet) direct infusion (electrospray ionization) direct inlet (electron ionization) (chemical ionization) (ionization chamber) 33

22 (reactant ion) direct insertion probe (DIP) (ionization chamber) (direct inlet) direct liquid introduction (DLI) (chemical ionization) (ionization chamber) direction focusing m/z (magnetic sector) discharge ionization 19 discrete dynode electron multiplier (secondary electron) (continuous dynode electron multiplier) (secondary electron multiplier) 34

23 dissociative ionization A BC A B C e (dissociative Penning ionization) (dissociative ionization) dissociative Penning ionization (dissociative ionization) distonic ion (diradical) (radical cation) (radial anion) CH 2 OH 2 (distonic ion) CH 3 OH double-focusing mass spectrometer (velocity focusing) (direction focusing) (electric sector: E) (magnetic sector: B) E B (forward geometry, EB geometry) B E (reverse geometry BE geometry) dynamic field mass spectrometer m/z dynamic pulse heating 2500 K 35

24 E 2 /V linked scan E 2 /V E 2 /V E 2 /V (linked scan at constant E 2 /V) einzel lens 3 electric sector (sector mass spectrometer) (time-of-flight mass spectrometer) (electrostatic energy analyzer) electrohydrodynamic ionization (EHI EHDI) ( 10 kv) (spray ionization) (cluster ion) (massive-cluster impact ionization) [M H] [M Na] 36

25 electron accelerating voltage (electron ionization) electron a$nity E EA M M M e M M electron capture chemical ionization (ECCI) (chemical ionization) electron capture dissociation (ECD) (multiply protonated molecule) (charge number) (odd-electron ion) [M nh] (n 1) electron capture ionization (ECI) M electron capture reaction (charge transfer reaction) 37

26 (multiply-charged ion) (autoionization) transferionization electron energy (electron ionization) (electron volt, ev) electron impact ionization (electron ionization) electron ionization (EI) ev (electron impact ionization) electron volt (ev) 1 ev SI SI 1eV (40) J 2 electrospray (ES) kv electrospray ionization (ESI) (electrospray) 38

27 kv Taylor cone (Rayleigh limit) electrostatic energy analyzer (ESA) (electric sector) emittance (1) (ion optics) (2) 3/2 (perviance) [A V 3/2 ] energy focusing even-electron ion [M H],[M H],CH 3,NH 4,OH 39

28 even-electron rule (odd-electron ion) (fragmentation) (even-electron ion) (odd-electron rule) exact mass (10 3 u) (monoisotopic mass) calculated exact mass Accurate mass excess energy (fragmentation) extracted ion chromatogram (EIC) 1 m/z (relative intensity) (hyphenated method) Faraday cup (secondary electron) 40

29 fast atom bombardment (FAB) kev Ar, Xe (matrix fast atom bombardment) (solid fast atom bombardment) (gas-phase fast atom bombardment) fast ion bombardment (FIB) kev (liquid secondary ionization) fast particle bombardment (FPB) kev kev (fast atom bombardment) (fast ion bombardment) field desorption (FD) (field desorption/ionization) field desorption/ionization (field desorption) field emitter (field desorption) (field ionization) 41

30 field ionization (FI) field ionization kinetics (FIK) (field ionization) field-free region (FFR) first stability region (transmission quadrupole mass spectrometer) (Paul ion trap) (Mathieu stability diagram) fission fragment ionization (plasma desorption/ionization) flash desorption (electron ionization) (chemical ionization) 42

31 focal plane detector (FPD) m/z (mass spectrograph) forward geometry (double-focusing mass spectrometer) forward library search (mass spectral library) (reverse library search) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICRMS) m/z m/z (cyclotron motion) (ion cyclotron resonance mass spectrometer) 43

32 Fourier transform mass spectrometry (FTMS) m/z (Fourier transform ion cyclotron resonance mass spectrometry) fragment fragment ion 1 (product ion) (precursor ion) (daughter ion) fragment ion scan (product ion scan) fragment ion spectrum (product ion spectrum) fragment peak (fragment ion) fragmentation 44

33 fringe field (electric sector) (magnetic sector) full width at half maximum (FWHM) 1 (sector mass spectrometer) 10 2 (mass resolution) gas chromatograph-mass spectrometer (GC-MS) gas chromatography/mass spectrometry (GC/MS) gas-phase fast atom bombardment (fast atom bombardment) glow discharge ionization granddaughter ion (2nd generation product ion) gridless reflectron 45

34 (reflectron) hard ionization (fragmentation) (soft ionization) heavy ion induced desorption (HIID) MeV u (fast particle bombardment) Herzog shunt (field-free region) (electric sector) (magnetic sector) heterolysis (heterolytic cleavage) heterolytic cleavage (fragment) 2 2 high temperature mass spectrometer (Knudsen cell mass spectrometer) high-energy collision-induced dissociation 1keV (laboratory collision energy) (collision-induced dissociation) (low-energy collision-induced dissoci- 46

35 ation) 1 (single collision) high-field asymmetric waveform ion mobility spectrometry (FAIMS) FAIMS 50 (RF-DC ion mobility spectrometry) (ion mobility spectrometry) homolysis (homolytic cleavage) homolytic cleavage (fragment) 2 1 (odd-electron ion) 1 (fragmentation) (even-electron ion) homolytic cleavage hybrid mass spectrometer MS/MS (mass spectrometry/mass spectrometry) (massanalyzer) hydrogen/deuterium exchange (HDX) (collision gas) 47

36 hyphenated method ICF flange ICF (conflat flange) (International ConFlat flange) imaging mass spectrometry m/z in-beam chemical ionization (in-beam method) in-beam electron ionization (in-beam method) in-beam method (ionization chamber) (reactant ion) (electron ionization) (chemical ionization) (direct exposure method) (field desorption) (ion/molecule reaction) (in-beam chemical ionization) (inbeam electron ionization) 48

37 M [M H] (direct chemical ionization) (desorption chemical ionization) (desorption electron ionization) inductive cleavage 2 inductively coupled plasma (ICP) MHz MHz Ar 5,000 7,000 K inductively coupled plasma mass spectrometry (ICP-MS) (inductively coupled plasma) infrared multiphoton dissociation (IRMPD) CO 2 (low-energy collision-induced dissociation) (fragmentation) in-gel digestion 49

38 (peptide mass fingerprinting) in-source collision-induced dissociation (collisional excitation) (ion desolvation) in-source decay (ISD) (matrix-assisted laser desorption/ionization: MALDI) (postsource decay) MALDI (ionization chamber) (fragmentation) (prompt fragmentation) MALDI c (c-ion) z (z-ion) intensity m/z (relative intensity) internal standard m/z intramolecular proton bound protonated molecule (protonated 50

39 molecule) ion fragment ion accelerating voltage ion collector (Faraday cup) (secondary electron multiplier) ion cooling (ion trap) (sensitivity) (mass resolving power) MS/MS (mass spectrometry/mass spectrometry) ion cyclotron resonance mass spectrometer (ICRMS) (cyclotron motion) m/z m/z Q (cyclotron motion) (Fourier transform ion cyclotron resonance mass spectrometer) 51

40 ion desolvation ion energy loss spectrum (relative intensity) (ion kinetic energy spectrometry) MIKE (mass-analyzed ion kinetic energy spectrometry) ion gate (ion mobility spectrometry) (time-of-flight mass spectrometer) (mass gate) ion guide (collision quadrupole) ion kinetic energy spectrometry (IKES) IKE (double-focusing mass spectrometer) (metastable ion) (electric sector) (scan) (ion energy loss spectrum) MIKE (mass-analyzed ion kinetic energy spectrometry) 52

41 ion mirror (time-of-flight mass spectrometer) (energy focusing) (reflectron) ion mobility spectrometry (IMS) (bu#er gas) (charge number) (v) (E) (v me) (m) (mobility) ion optics ion source (ionization chamber) ion spray (pneumatically-assisted electrospray ionization) ion trap (IT) 53

42 (Paul ion trap) (Penning ion trap) (Kingdon trap) ion trap mass spectrometer (ITMS) (ion trap) (Paul ion trap) m/z (time-of-flight mass spectrometer) m/z (linear ion trap) Kingdon trap Orbitrap (Fourier transform ion cyclotron resonance: FT-ICR) ion/ion reaction (ion ion reaction) ion/molecule reaction (charge exchange reaction) (ion-molecule reaction) 54

43 ion/neutral complex (fragmentation) (precursor ion) (product ion) (ion-neutral complex) ion/neutral exchange reaction (ion neutral exchange reaction) ion/neutral reaction (ion neutral reaction) ionic dissociation 1 1 (charge number) ionization ionization chamber (reactant ion) 55

44 ionization cross section ionization e$ciency ionization e$ciency curve ionization energy (IE) 1 ionization potential (ionization energy) ionizing cell ionization chamber ionizing collision 1 ionizing voltage (electron ionization) 56

45 ion-pair formation 1 2M [M H] [M H] AX A X AX A X ion-to-photon detector (photomultiplier) (conversion dynode) isomeric ion isotope cluster (isotope pattern) isotope dilution mass spectrometry (IDMS) (internal standard) isotope e#ect (isotope labeling) (gas chromatography/mass spectrometry) (fragment ion) isotope labeling 1 (frag- 57

46 mentation) (internal standard) isotope pattern (isotope cluster) isotope peak (isotopolog ions) isotope ratio mass spectrometry (IRMS) isotopically enriched ion C 13 C 13 C 1.1 isotopolog ions (monoisotopic ion) CH 4 CH 3 D (isotope pattern) isotopomeric ions 58

47 kinetic energy analyzer kinetic energy release (KER) (1) (metastable ion decay) (precursor ion) (2) (metastable ion) (metastable peak) kinetic energy release distribution (KERD) (metastable ion) (kinetic energy release) kinetic method (tandem mass spectrometry) (relative abundance) 59

48 Kingdon trap (ion trap) m/z (mass analyzer) Orbitrap, Knudsen cell 1mm RF Knudsen cell mass spectrometer (high temperature mass spectrometer) (electron ionization) Knudsen e#usion mass spectrometer (Knudsen cell mass spectrometer) 60

49 laboratory collision energy (collision-induced dissociation) (V) (charge number) z e (electron volt) (center-of-mass collision energy) laser ablation (LA) laser beam ionization laser desorption (LD) fragment laser desorption/ionization (LDI) laser ionization (LI) laser microprobe mass spectrometry (LMMS) 61

50 (laser desorption/ionization) laser spray (LS) kv W (electrospray) linear ion trap (LIT) (Paul ion trap) linked scan 2 (mass analyzer) (tandem mass spectrometer) (magnetic sector) (electric sector) 1 (sector mass spectrometer) 2 (product ion spectrum) (precursor ion spectrum) (constant neutral loss spectrum) (constant neutral mass gain spectrum) linked scan at constant B/E B/E B/E (magnetic sector) (electric sector) 1 (sector mass spectrometer) V B 62

51 E B E (field-free region) (product ion spectrum) B/E (B/E linked scan) linked scan at constant B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E (magnetic sector) (electric sector) 1 (sector mass spectrometer) V B E B[1 (E/E 0 )] 1/2 /E B E (field-free region) (constant neutral loss spectrum) (constant neutral mass gain spectrum) E 0 E B[1 (E/E 0 )] 1/2 /E (B[1 (E/E 0 )] 1/2 /E linked scan) linked scan at constant B 2 /E B 2 /E B 2 /E (magnetic sector) (electric sector) 1 (sector mass spectrometer) V B E B 2 /E B E (field-free region) (precursor ion spectrum) B 2 /E (B 2 /E linked scan) 63

52 linked scan at constant E 2 /V E 2 /V E 2 /V (magnetic sector) (electric sector) 1 (sector mass spectrometer) E V E 2 /V E V (field-free region) (product ion spectrum) E 2 /V (E 2 /V linked scan) liquid chromatograph-mass spectrometer (LC-MS) liquid chromatography/mass spectrometry (LC/MS) liquid ionization (LI) Ar (ion/molecule reaction) (matrix) (soft ionization) (atmospheric pressure ionization) (Penning ionization) liquid secondary ionization (LSI) 64

53 (fast particle bombardment) (secondary ionization) low-energy collision-induced dissociation 1,000 ev (laboratory collision energy) (collision-induced dissociation) (multiple collision) (collisional excitation) (high-energy collision-induced dissociation) m/z m/z m z (charge number) (unified atomic mass unit) (mass-to-charge-ratio) m/z m/z m/z 100 m/z 100 m/z thomson, Th magnetic deflection (magnetic sector) magnetic field scan 65

54 magnetic sector m/z magnetic shim (magnetic sector) (fringe field) mass SI (kg) SI (unified atomic mass unit) mass accuracy (ppm) (exact mass) mass analysis m/z mass analyzer m/z 66

55 mass calibration m/z m/z mass chromatogram (extracted ion chromatogram) mass defect (1) (mass number) (nominal mass) (monoisotopic mass) (mass excess) (2) (mass defect) mass discrimination (sensitivity) mass excess (mass defect) mass fragmentogram (gas chromatography/mass spectrometry) m/z (relative intensity) (selected ion monitoring) 67

56 mass gate m/z (ion gate) mass limit m/z mass marker (sector mass spectrometer) m/z (mass calibration) mass number A (nominal mass) mass range m/z mass resolution m/z m/z D(m/z) (m/z)/d(m/z) 1. m/z 2. D(m/z) D(m/z) 68

57 3. D(m/z) 2 mass resolving power (mass resolution) m/z D(m/z) mass selective axial ejection (mass selective instability) (Paul ion trap) m/z mass selective instability (Paul ion trap) m/z mass spectral library m/z (monoisotopic mass spectrum) mass spectrograph m/z (focal plane detector) (mass spectrometer) 69

58 mass spectrometer m/z mass spectrometric detector mass spectrometric thermal analysis (MTA) mass spectrometry (mass spectrometer) (mass spectrograph) (mass spectroscopy) mass spectrometry/mass spectrometry (MS/MS) MS/MS m/z 1 m/z (precursor ion) (tandem mass spectrometry) (mass analyzer) (tandem mass spectrometry in space) (ion trap) (tandem mass spectrometry in time) mass spectroscope (mass spectrometer) 70

59 (mass spectrograph) mass spectroscopy m/z (relative abundance) (mass spectrometry) mass spectrum (relative abundance) m/z mass-analyzed ion kinetic energy spectrometry (MIKES) MIKE (magnetic sector) (electric sector) 1 (reverse geometry) (sector mass spectrometer) V B m/z (precursor ion) (field-free region) (product ion) (electric sector) (scan) (product ion spectrum) (kinetic energy release distribution) (double-focusing mass spectrometer) (direct analysis of daughter ions) massive-cluster impact ionization (MCI) ( 0.01 mm) 71

60 10 7 u kv (fast atom bombardment) (electrohydrodynamic ionization) mass-to-charge ratio m/z m/z Mathieu stability diagram (transmission quadrupole mass spectrometer) (Paul ion trap) matrix (fast atom bombardment) (liquid secondary ionization) (matrix-assisted laser desorption/ionization) (massive-cluster impact ionization) (liquid ionization) matrix fast atom bombardment (fast atom bombardment) 72

61 matrix-assisted laser desorption/ionization (MALDI) (matrix) (laser desorption/ionization) matrix-assisted plasma desorption (MAPD) (analyte) (plasma desorption/ionization) Matsuda plate Mattauch Herzog geometry (electric sector) p/(4 2) (magnetic sector) p/2 (magnetic deflection) (double-focusing mass spectrometer) (mass spectrograph) McLa#erty rearrangement EI g g 6 g 73

62 measured accurate mass p. 14, accurate mass membrane inlet mass spectrometry (membrane introduction mass spectrometry) membrane interface mass spectrometry (membrane introduction mass spectrometry) membrane introduction mass spectrometry (MIMS) (analyte) (membrane separator) (membrane inlet mass spectrometry) (membrane interface mass spectrometry) metastable ion (MI) (mass analyzer) (stable ion) (unstable ion) metastable ion decay (MID) (metastable ion) 74

63 metastable peak (metastable ion) microchannel plate (MCP) (continuous dynode electron multiplier) (secondary electron) microelectrospray (micro-es) 1 ml min 1 (electrospray ionization) (nanoelectrospray) milli-atomic mass unit (millidalton, mda) milli-mass unit (mmu) (unified atomic mass unit) 1 dalton, Da 10 SI (millidalton, mda) molecular anion (molecular ion) 75

64 molecular beam mass spectrometry (MBMS) molecular cation (molecular ion) molecular ion 1 1 (radical ion). molecular protonated ion (protonated molecule) molecular weight (atomic weight) u, Da, g molecular-related ion (pseudo-molecular ion quasi-molecular ion) (protonated molecule) (cationized molecule) [M Na] [M H] momentum dispersion (magnetic sector) 76

65 monoisotopic mass (exact mass) MS/MS spectrum MS/MS (precursor ion spectrum) (product ion spectrum), (1st generation product ion spectrum) MS 3 spectrum MS 3 (2nd generation product ion spectrum) MS n MS n n (multiple-stage mass spectrometry) (precursor ion) (product ion) n n MS n 1 (triple quadrupole mass spectrometer) n 2 (ion trap mass spectrometer) n 2 MS/MS n (nth generation product ion) multiphoton ionization (MPI) (photoionization) multiple collision (collision gas) (product ion) 77

66 (ion trap) (collision cell) (triple quadrupole mass spectrometer) (collisioninduced dissociation) multiple reaction monitoring (MRM) (selected reaction monitoring) multiple-stage mass spectrometry m/z 2 n (nth generation product ion) MS n multiply deprotonated molecule M H [M nh] n (electrospray ionization) multiply protonated molecule M H [M nh] n (electrospray ionization) multiply-charged ion M 3,M 3,[M 5H] 5 [M 5H] 5 nanoelectrospray (nano-es) 100 nl min 1 78

67 (electrospray ionization) (microelectrospray) (nanospray) nanospray (nanoelectrospray) negative ion M,[M H],[M O] negative ion chemical ionization (NICI) (chemical ionization) M OH F M [M H] Cl M [M Cl] e M M OH or F M [M H] H 2 OorHF Cl M [M Cl] neutral fragment reionization (NFR) (collision cell) MS/MS (mass spectrometry/mass spectrometry) neutral loss (precursor ion) 79

68 neutralization reionization mass spectrometry (NRMS) m/z (collision gas) (collision cell) (fragmentation) Nier-Johnson geometry (electric sector) p/2 p/3 (magnetic deflection) (magnetic sector) (double-focusing mass spectrometer) nitrogen rule C, H, O, S, P (nominal mass) nominal mass (mass number) non-classical ion 5 80

69 nozzle-skimmer collision-induced dissociation (capillary-skimmer collision-induced dissociation) nth generation product ion n (precursor ion) (product ion) n 4 M 1 M 2 M 3 M 4 M 5 M 4 M 5 M 3 M 2 M 1 (multiple-stage mass spectrometry) (granddaughter ion) nth generation product ion spectrum n n (nth generation product ion) octapole 8 (octapole lens) (mass analyzer) (ion guide) odd-electron ion M (radical ion) 81

70 odd-electron rule (even-electron rule). oil di#usion pump 10 7 Pa (di#usion pump) oil sealed vacuum pump (rotary vane pump) onium ion orbitrap (Kingdon trap) organic secondary ion mass spectrometry kev kev Ar,Xe,Cs (static secondary ion mass spectrometry) 82

71 orthogonal acceleration (orthogonal extraction) orthogonal extraction (timeof-flight mass spectrometer) (ion mobility spectrometry) (orthogonal acceleration) parent ion (precursor ion) parent ion scan (precursor ion scan) parent ion spectrum (precursor ion spectrum) partial charge exchange reaction (partial charge transfer reaction) partial charge transfer reaction particle beam (PB) 83

72 (ionization chamber) (electron ionization) (chemical ionization) (liquid chromatograph-mass spectrometer) pascal (Pa) SI Nm 2 1Pa 10 mbar, 133 Pa 1 Torr 1 mmhg. Paul ion trap m/z m/z m/z (ion trap) (Mathieu stability diagram) peak peak intensity peak matching m/z m/z (reference ion) 84

73 m/z Penning ion trap (ion trap) (Fourier transform ion cyclotron resonance mass spectrometer) (mass analyzer) Penning ionization 2 (chemi-ionization) photodissociation 1 photo-induced dissociation (PID) 1 2 (infrared multiphoton dissociation) photoionization (PI) (hn) 85

74 plasma desorption/ionization (PDI) 252 Cf 106 Tc Ba 18 (fission fragment ionization) pneumatically-assisted electrospray ionization (electrospray ionization) (ionspray) point detector pole-piece positive ion M,[M H],[M Na] post-acceleration detector (PAD) m/z 86

75 post-source decay (PSD) (1) (matrixassisted laser desorption/ionization) (metastable ion decay) (2) (collisioninduced dissociation) (product ion) m/z (reflectron) (reflectron time-of-flight mass spectrometer) precursor ion (product ion) (unimolecular dissociation) (ion/molecule reaction) (parent ion) precursor ion scan (precursor ion spectrum) (parent ion scan) precursor ion spectrum (product ion) (precursor ion) (parent ion spectrum) 87

76 pre-ionization state (autoionization) principal ion BBr 3 11 B 79 Br 81 2 Br (isotope pattern) CH 13 3 CH 3 CH 2 D 2 (isotopically enriched ion) (isotopolog ion) principal isotope product ion (precursor ion) (fragment ion) (unimolecular dissociation) (ion/molecule reaction) (daughter ion) product ion analysis (product ion spectrum) (daughter ion analysis) product ion scan (product ion spectrum) (daughter ion scan) 88

77 (product ion analysis) product ion spectrum (precursor ion) (product ion) (fragment ion spectrum) (daughter ion spectrum) MS/MS (MS/MS spectrum) (precursor ion spectrum) (2nd generation product ion spectrum) profile acquisition (continuum acquisition) prolate trochoidal mass spectrometer m/z (cycloidal mass spectrometer) prompt fragmentation (in-source decay) proteome PROTEin genome 1994 M. R. Wilkins 89

78 (proteomics) proteomics (proteome) proton a$nity (PA) 298 K ( DH) (protonated molecule) (multiply protonated molecule) (proton acceptor) (proton donor) (deprotonated molecule) [M H] Brønsted Brønsted protonated molecular ion (protonated molecule) protonated molecule M H [M H] (pseudo-molecular ion quasi-molecular ion) [M Na],[M H] (protonated molecular ion) 2 90

79 proton-bound dimer M (M H M) 2 M 1 M 2 (M 1 H M 2 ) pseudo-molecular ion (protonated molecule) (cationized molecule) [M Na] [M H] pyrolysis gas chromatography mass spectrometry (PyGC/MS) pyrolysis mass spectrometry (PyMS) quadratic field reflectron 2 (reflectron) quadrupole ion storage (QUISTOR) (Paul ion trap) quadrupole ion trap (QIT) (Paul ion trap) quadrupole lens 4 91

80 quadrupole mass filter (QMF) (transmission quadrupole mass spectrometer) quadrupole mass spectrometer (QMS) (transmission quadrupole mass spectrometer) quasi-equilibrium theory (QET) Eyring Rosenstock, Wallenstein, Wahrhaftig Eyring 1952 (molecular ion) (non-radiative transition) Rice Ramsperger Kassel Marcus RRKM Miller Klots Chesnavichi Bowers (statistical phase space theory) (kinetic energy release) quasi-molecular ion (protonated molecule) (cationized molecule) [M Na] [M H] 92

81 radial electrostatic field analyzer (electrostatic energy analyzer) (electric sector) radical anion (radical ion) radical cation (radical ion) radical ion M M. 2 M (2 )(2 ) Rayleigh limit (electrospray ionization) reactant ion (chemical ionization) (reagent gas) CH 5,NH 4, t-c 4 H 9 93

82 reagent gas (ion/molecule reaction) (precursor ion) (product ion) (chemical ionization) (reagent ion) CH 4, NH 3, iso-c 4 H 10 (ion trap) (collision cell) reagent ion (chemical ionization) rearrangement ion (fragmentation) rearrangement reaction (rearrangement ion) (McLa#erty rearrangement) recombination energy 1 (vertical ionization energy) reconstructed ion chromatogram (extracted ion chromatogram) reference ion (stable ion) 94

83 reflectron (time-of-flight mass spectrometer) m/z (mass resolving power) (ion mirror) reflectron time-of-flight mass spectrometer (field-free region) (product ion) 2 (post-source decay) relative abundance (relative intensity) relative atomic mass (atomic weight) relative intensity 100 (base peak) m/z m/z

84 ( S) (height) (area) (abundance) relative molecular mass (unified atomic mass unit) (molar mass) relative sensitivity coe$cient (spark source mass spectrometry) (1.00) (relative intensity) remote site fragmentation (charge remote fragmentation) repeller voltage (ionization chamber) residual gas analyzer (RGA) residual mass spectrum 96

85 (background mass spectrum) resonance ion ejection (Paul ion trap) resonance ionization (RI) (resonance-enhanced multiphoton ionization) resonance-enhanced multiphoton ionization (REMPI) (multiphoton ionization) 1 (ionization cross section) reverse geometry (double-focusing mass spectrometer) reverse library search (mass spectral library) (forward library search) 97

86 RF-DC ion mobility spectrometry FAIMS (high-field asymmetric waveform ion mobility spectrometry) RF-only quadrupole RF (collision quadrupole) rotary pump (rotary vane pump) rotary vane pump (rotary pump) 10 2 Pa (turbo molecular pump) (oil rotary pump) scan (time-of-flight mass spectrometer) (Fourier transform mass spectrometry) (scan) second field-free region (electric sector) (magnetic sector) (doublefocusing mass spectrometer) (ionization chamber) 98

87 second law treatment (high temperature mass spectrometer) DH 0 v (third law treatment) secondary electron secondary electron multiplier (SEM) 100 ev 1 Cu Be 2 (discrete dynode electron multiplier) (continuous dynode electron multiplier) secondary ion mass spectrometry (SIMS) Ar,O 2,Cs (liquid secondary ion mass spectrometry) 99

88 secondary ionization secondary neutral mass spectrometry (SNMS) (secondary ion mass spectrometry) (fast atom bombardment) sector mass spectrometer (magnetic sector) 1 m/z (electric sector) 1 (doublefocusing mass spectrometer) selected ion detection (SID) (selected ion monitoring) selected ion flow tube (SIFT) m/z (ion/molecule reaction) selected ion monitoring (SIM) 1 m/z (liquid chromatography/mass spectrometry) 100

89 (gas chromatography/mass spectrometry) 14 selected reaction monitoring (SRM) 2 (MS n ) (product ion spectrum) 1 (product ion) (tandem mass spectrometry in space) (tandem mass spectrometry in time) (precursor ion) m/z m/z (selected ion monitoring) (multiple reaction monitoring) self-chemical ionization (self-ci) (analyte) (reactant ion) (chemical ionization) sensitivity 101

90 (detection limit) separator (gas chromatograph-mass spectrometer) He simple cleavage (fragmentation) (rearrangement reaction) single collision 1 (multiple collision) (collision gas) 1 1 L (collision cell) n 1 snl 1 s (doublefocusing mass spectrometer) (collision-induced dissociation) single-focusing mass spectrometer (direction focusing) (double-focusing mass spectrometer) skimmer 1mm 102

91 (electrospray ionization) (ion desolvation) skimmer collision-induced dissociation (capillaryskimmer collision-induced dissociation) soft ionization (fragmentation) (hard ionization) solid fast atom bombardment (fast atom bombardment) sonic spray ionization (SSI) (atmospheric pressure ionization) (multiply protonated molecule) space charge e#ect (space charge) (sensitivity) (mass resolving power) (mass accuracy) 103

92 spark ionization spark source mass spectrometry (spark ionization) spike (isotope dilution mass spectrometry) spray ionization (electrospray ionization) (thermospray ionization) (sonic spray ionization) sputtered neutral mass spectrometry (secondary neutral mass spectrometry) stability diagram (Mathieu stability diagram) stable ion (rearrangement reaction) (metastable ion) (unstable ion) 104

93 static field static secondary ion mass spectrometry (secondary ion mass spectrometry) ions/cm 2 stored waveform inverse Fourier transform (SWIFT) SWIFT (Paul ion trap) (Fourier transform ion cyclotron resonance mass spectrometer) MS/ MS (mass spectrometry/mass spectrometry) (precursor ion) superelastic collision (collision of the second kind) surface ionization (SI) (ionization energy) Saha Langmuir 105

94 surface-assisted laser desorption/ionization (SALDI) (desorption ionization) (desorption ionization on silicon) surface-enhanced laser desorption/ionization (SELDI) SELDI (analyte) (matrix-assisted laser desorption/ionization) surface-induced dissociation (SID) (collision-induced dissociation) surface-induced reaction (SIR) sustained o#-resonance irradiation (SORI) (Fourier transform ion cyclotron resonance mass spectrometer) (ion/neutral reaction) (cyclotron motion) (Penning ion trap) (collisional excitation) 106

95 (low-energy collision-induced dissociation) tandem mass spectrometer MS/MS (mass spectrometry/mass spectrometry) tandem mass spectrometry MS/MS (mass spectrometry/mass spectrometry) tandem mass spectrometry in space (mass analyzer) MS/MS (mass spectrometry/mass spectrometry) (precursor ion) (product ion) m/z MS/MS (MS/MS in space) tandem mass spectrometry in time (Paul ion trap) (Fourier transform ion cyclotron resonance mass spectrometer) 1 (mass analyzer) (product ion spectrum) MS/MS (mass spectrometry/mass spectrometry) (precursor ion) (product ion) MS/MS (MS/MS in time) target gas (collision gas) 107

96 thermal ionization (TI) thermal surface ionization (TSI) (surface ionization) 1,000 W Re thermogravimetry mass spectrometry (TG/MS) thermospray (TS) Pa thermospray ionization (TSI) (thermospray) (discharge ionization) (electron ionization) third law treatment (high temperature mass spectrometer) DH 0 v (298 K) DH 0 v (second law treatment) 108

97 thomson (Th) m/z time lag focusing (TLF) (time-of-flight mass spectrometer) (energy focusing) (delayed extraction) time-of-flight mass spectrometer (TOF-MS) (field-free region) m/z (reflectron time-of-flight mass spectrometer) Torr 1 Torr 1 mmhg 1.33 mbar 133 Pa SI pascal, Pa total emission current (electron ionization) total ion chromatogram (total ion current chromatogram) total ion current (TIC) m/z m/z 109

98 total ion current chromatogram (TICC) (gas chromatography/mass spectrometry) (liquid chromatography/mass spectrometry) (total ion current) total ion chromatogram (TIC) total ion current chromatogram (TICC) total ion detection (TID) (total ion monitoring) total ion monitoring (TIM) (selected ion monitoring) (liquid chromatography/mass spectrometry) (gas chromatography/mass spectrometry) m/z transmission e$ciency (mass analyzer) transmission quadrupole mass spectrometer 4 (quadrupole) (Mathieu equation) 110

99 m/z m/z (quadrupole mass filter) (Mathieu stability diagram) triple quadrupole mass spectrometer (transmission quadrupole mass spectrometer) 2 m/z (collision cell) (tandem mass spectrometer) trochoidal focusing mass spectrometer prolate trochoidal mass spectrometer troidal field turbo molecular pump (rotary vane pump) (di#erential pumping) unified atomic mass unit (u)

100 (83) kg u SI SI m/z (charge number) SI kg atomic mass unit amu (standard atomic weight) unimolecular dissociation unstable ion (collision cell) (in-source decay), (metastable ion) (stable ion) vaporization coe$cient (Knudsen cell) a a c P e J c J c a c P e (2pMkT) 1/2 a c 112

101 J v J v J c J v a a v a 1 (Knudsen cell mass spectrometer) velocity focusing m/z (time-of-flight mass spectrometer) vertical ionization voltage scan (accelerating voltage) (electric field scan) Wien filter x-ion x C C (fragment ion) C y-ion y C N (fragment ion) C 113

102 z-ion z C N N C a (fragment ion) C 114

103 anion radical (radical anion) appearance potential (AP) (electron ionization) IUPAC (appearance energy) atomic mass unit (amu) unified atomic mass unit, u dalton, Da B/E linked scan B/E B/E B/E B/E (linked scan at constant B/E) B[1 (E/E 0 )] 1/2 /E linked scan B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E B[1 (E/E 0 )] 1/2 /E (linked scan at constant B[1 (E/E 0 )] 1/2 /E) B 2 /E linked scan B 2 /E B 2 /E B 2 /E B 2 /E (linked scan at constant B 2 /E) cation radical (radical cation) 115

104 cycloidal mass spectrometer (prolate trochoidal mass spectrometer) daughter ion (product ion) daughter ion analysis (product ion analysis) daughter ion scan (product ion scan) daughter ion spectrum (product ion spectrum) direct analysis of daughter ions (DADI) MIKE (mass-analyzed ion kinetic energy spectrometry) E 2 /V linked scan E 2 /V E 2 /V E 2 /V E 2 /V (linked scan at constant E 2 /V) electron impact ionization (electron ionization) field desorption/ionization (field desorption) 116

105 fragment ion scan (product ion scan) fragment ion spectrum spectrum) (product ion granddaughter ion (2nd generation product ion) ionization potential (ionization energy) ion spray (pneumatically-assisted electrospray ionization) mass chromatogram (extracted ion chromatogram) mass excess (mass defect) mass spectroscope (mass spectrometer) (mass spectrograph) mass spectroscopy (mass spectrometry) 117

106 mass-to-charge-ratio m/z milli-atomic mass unit (millidalton mda) milli-mass unit (mmu) (millidalton mda) molecular protonated ion (protonated molecule) molecular-related ion (protonated molecule) (cationized molecule) [M Na] [M H] MS/MS spectrum MS/MS (precursor ion spectrum) (product ion spectrum) MS 3 spectrum MS 3 (2nd generation product ion spectrum) multiple reaction monitoring (MRM) (selected reaction monitoring: SRM) nanospray (nanoelectrospray) 118

107 orbitrap (Kingdon trap) parent ion (precursor ion) parent ion scan (precursor ion scan) parent ion spectrum (precursor ion spec- trum) protonated molecular ion (protonated molecule) pseudo-molecular ion (protonated molecule) (cationized molecule) [M Na] [M H] quasi-molecular ion (protonated molecule) (cationized molecule) [M Na] [M H] reconstructed ion chromatogram (extracted ion chromatogram) 119

108 selected ion detection (selected ion monitoring) target gas (collision gas) thomson (Th) m/z m/z Torr 1 Torr 1 mmhg 133 Pa, 1 Pa 10 mbar. SI pascal, Pa total ion chromatogram (TIC) (total ion current chromatogram) total ion detection (TID) (total ion monitoring) trochoidal focusing mass spectrometer prolate trochoidal mass spectrometer 120

109 isotopomeric ions 58 Einzel lens 36 acceptance 14 analog ion 15 anion radical 15, 115 anionized molecule 16 abundance sensitivity 14 oil sealed vacuum pump 82 oil di#usion pump 82 array detector 16 stable ion 104 stability diagram 104 ion 51 ion/ion reaction 54 ion mobility spectrometry (IMS) 53 ion kinetic energy spectrometry (IKES) 52 ion energy loss spectrum 52 ionization 55 ion guide 52 ionic dissociation 55 ionization energy (IE) 56 ionization e$ciency 56 ionization e$ciency curve 56 ionization chamber 55 ionizing cell 56 ion accelerating voltage 51 ionization cross section 56 ionizing voltage

110 ionization potential 56, 117 ion gate 52 ion source 53 ion optics 53 ion-to-photon detector 57 ion collector 51 ion cyclotron resonance mass spectrometer (ICRMS) 51 ion spray 53, 117 ion desolvation 52 ion-pair formation 57 transmission e$ciency 110 ion trap (IT) 53 ion trap mass spectrometer (ITMS) 54 ion/neutral complex 55 ion/neutral exchange reaction 55 ion/neutral reaction 55 ion/molecule reaction 54 ion mirror 53 ion mobility spectrometry (IMS) 53 ion cooling 51 isomeric ion 57 single collision 102 imaging mass spectrometry 48 in-source collision-induced dissociation 50 in-source decay (ISD) 50 in-beam electron ionization 48 in-beam method 48 in-beam chemical ionization 48 Wien filter 113 kinetic energy analyzer 59 kinetic energy release (KER)

111 kinetic energy release distribution (KERD) 59 momentum dispersion 76 liquid ionization (LI) 64 liquid chromatography/mass spectrometry (LC/MS) 64 liquid chromatograph-mass spectrometer (LC-MS) 64 liquid secondary ionization (LSI) 64 energy focusing 39 emittance 39 MS n 77 mass spectrometry/mass spectrometry (MS/MS) 70 electrospray (ES) 38 electrospray ionization (ESI) 38 electrohydrodynamic ionization (EHI EHDI) 36 orbitrap 82, 119 octapole 81 onium ion 82 parent ion 83, 119 parent ion scan 83, 119 parent ion spectrum 83, 119 curved field reflectron 29 associative ionization 16 associative ion/molecule reaction 16 rotary pump 98 dissociative ionization 35 dissociative Penning ionization 35 cleavage 24 chemical ionization (CI) 23 chemi-ionization

112 di#usion pump 32 fission fragment ionization 42 excess energy 40 gas chromatography/mass spectrometry (GC/MS) 45 gas chromatograph-mass spectrometer (GC-MS) 45 accelerator mass spectrometry (AMS) 14 accelerating voltage 14 cationized molecule 20 cation radical 20, 115 bath gas 19 bu#er gas 19 sensitivity 101 base peak (BP) 19 base peak chromatogram 19 odd-electron ion 81 odd-electron rule 82 gas-phase fast atom bombardment 45 pseudo-molecular ion 91, 119 quasi-molecular ion 92, 119 reverse geometry 97 reverse library search 97 capillary-skimmer collision-induced dissociation 20 capillary electrophoresis mass spectrometry (CE/MS) 20 flash desorption 42 resonance ionization (RI) 97 resonance ion ejection 97 resonance-enhanced multiphoton ionization (REMPI) 97 pneumatically-assisted 124

113 electrospray ionization 86 Kingdon trap 60 tandem mass spectrometry in space 107 space charge e#ect 103 even-electron ion 39 even-electron rule 40 Coulomb explosion 28 Knudsen cell 60 Knudsen cell mass spectrometer 60 Knudsen e#usion mass spectrometer 60 cluster 25 cluster ion 25 gridless reflectron 45 glow discharge ionization 45 chromatograph 24 chromatography 24 chromatogram 24 calculated exact mass 20 exact mass 40 in-gel digestion 49 atomic mass unit (amu) 17, 115 detection limit 32 atomic weight 17 high-energy collision-induced dissociation 46 high temperature mass spectrometer 46 fast ion bombardment (FIB) 41 fast atom bombardment (FAB) 41 fast particle bombardment (FPB) 41 post-acceleration detector (PAD) 86 RF-DC ion mobility spectrometry 98 blackbody infrared radiative dissociation (BIRD) 19 solid fast atom bombardment

114 corona discharge 28 constant neutral mass gain scan 27 constant neutral mass gain spectrum 27 constant neutral loss scan 27 constant neutral loss spectrum 27 continuum acquisition 28 conversion dynode 28 thermospray (TS) 108 thermospray ionization (TSI) 108 cycloidal mass spectrometer 29, 116 cyclotron motion 29 recombination energy 94 reconstructed ion chromatogram 94, 119 di#erential pumping 32 reference ion 94 residual gas analyzer (RGA) 96 residual mass spectrum 96 triple quadrupole mass spectrometer 111 tandem mass spectrometry in time 107 self-chemical ionization (self-ci) 101 collision quadrupole 25 quadrupole ion storage (QUISTOR) 91 quadrupole ion trap (QIT) 91 quadrupole mass spectrometer (QMS) 92 quadrupole mass filter (QMF) 92 quadrupole lens 91 sustained o#-resonance irradiation (SORI) 106 laboratory collision energy

115 mass 66 mass analysis 66 mass accuracy 66 mass calibration 67 mass discrimination 67 mass limit 68 mass accuracy 66 mass number 68 mass selective axial ejection 69 mass selective axial ejection 69 mass selective instability 69 mass-to-charge ratio 72, 118 mass range 68 mass resolution 68 mass resolving power 69 mass spectroscopy 71, 117 mass spectrometry (MS) 70 mass spectrograph 69 mass spectrometer 70 mass spectrometric detector 70 mass analyzer 66 mass discrimination 67 autoionization 18 autodetachment 18 magnetic field scan 65 magnetic sector 66 sector mass spectrometer 100 magnetic field scan 65 magnetic deflection 65 reagent ion 94 reagent gas 94 principal ion 88 center-of-mass kinetic energy

116 center-of-mass collision energy 20 heavy ion induced desorption (HIID) 46 appearance energy (AE) 16 appearance potential (AP) 16, 115 principal isotope 88 metastable ion (MI) 74 metastable ion decay (MID) 74 metastable peak 75 forward geometry 43 quasi-equilibrium theory (QET) 92 forward library search 43 focal plane detector (FPD) 43 collision gas 25 collisional activation (CA) 26 collisionally activated dissociation (CAD) 26 collision cell 25 collision chamber 25 collision cell 25 collision reaction cell 26 collision-induced dissociation (CID) 26 collisional excitation 26 vaporization coe$cient 112 desorption ionization on silicon (DIOS) 31 intensity 50 diagnostic ion 32 hydrogen/deuterium exchange (HDX) 47 vertical ionization 113 (SWIFT ) stored waveform inverse Fourier transform (SWIFT) 105 skimmer 102 skimmer collision-induced dissociation 103 scan 98 static secondary ion mass 128

117 spectrometry 105 spark ionization 104 spark source mass spectrometry 104 spike 104 sputtered neutral mass spectrometry 104 spray ionization 104 positive ion 86 electrostatic energy analyzer (ESA) 39 forward geometry 43 accurate mass exact mass 14, 40 infrared multiphoton dissociation (IRMPD) 49 separator 102 (SELDI ) surface-enhanced laser desorption/ ionization (SELDI) 106 total ion chromatogram 109, 120 total ion detection (TID) 110, 120 total ion current (TIC) 109 total ion current chromatogram (TICC) 110 total ion monitoring (TIM) 110 pre-ionization state 88 precursor ion 87 precursor ion scan 87 precursor ion spectrum 87 selected ion detection (SID) 100, 120 selected ion monitoring (SIM) 100 selected reaction monitoring (SRM) 101 selected ion flow tube (SIFT) 100 centroid acquisition 21 total emission current 109 scan 98 relative sensitivity coe$cient 96 relative intensity 95 relative atomic mass

118 relative abundance 95 relative molecular mass 96 accurate mass 14 measured accurate mass 74 velocity focusing 113 kinetic method 59 sonic spray ionization (SSI) 103 soft ionization 103 target gas 107, 120 turbo molecular pump 111 first stability region 42 atmospheric pressure ionization (API) 17 atmospheric pressure chemical ionization (APCI) 16 atmospheric pressure spray 17 atmospheric pressure photoionization (APPI) 17 atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) 17 third law treatment 108 dynamic pulse heating 35 second field-free region 98 second law treatment 99 time lag focusing (TLF) 109 multiply-charged ion 78 multiply deprotonated molecule 78 multiply protonated molecule 78 multiphoton ionization (MPI) 77 multiple collision 77 multiple reaction monitoring (MRM) 78, 118 multiple-stage mass spectrometry 78 deprotonated molecule 30 desorption ionization (DI)

119 desorption electrospray ionization (DESI) 31 desorption chemical ionization (DCI) 31 desorption electron ionization (DEI) 31 dalton (Da) 29 fringe field 45 single-focusing mass spectrometer 102 simple cleavage 102 tandem mass spectrometry 107 tandem mass spectrometer 107 adiabatic ionization 15 unimolecular dissociation 112 unimolecular dissociation 112 delayed extraction (DE) 30 nitrogen rule 80 charge mediated fragmentation 22 charge remote fragmentation (CRF) 22 channel electron multiplier 21 channeltron 21 extracted ion chromatogram (EIC) 40 neutralization reionization mass spectrometry (NRMS) 80 neutral fragment reionization (NfR) 79 direct insertion probe (DIP) 34 superelastic collision 105 direct liquid introduction (DLI) 34 direct dissociation 33 direct chemical ionization 33 direct exposure probe (DEP) 33 direct infusion 33 direct inlet

86 MS MS GC LC GC LC Fig. 1.MS 3. 質 量 分 析 計 の 構 成 1 試 料 導 入 部 2イオン 化 部 3イオン 分 離 部 4イオン 検 出 部 5データ 処 理 部 10 4 10 6 Pa Fig. 2.

86 MS MS GC LC GC LC Fig. 1.MS 3. 質 量 分 析 計 の 構 成 1 試 料 導 入 部 2イオン 化 部 3イオン 分 離 部 4イオン 検 出 部 5データ 処 理 部 10 4 10 6 Pa Fig. 2. Bulletin of Osaka University of Pharmaceutical Sciences 6 (2012) 85 有 機 化 学 実 験 のための 易 しいマススペクトロメトリー Concise Mass Spectrometry for Experiments of Organic Chemistry Note Mihoyo Fujitake Osaka University

More information

untitled

untitled 27.2.9 TOF-SIMS SIMS TOF-SIMS SIMS Mass Spectrometer ABCDE + ABC+ DE + Primary Ions: 1 12 ions/cm 2 Molecular Fragmentation Region ABCDE ABCDE 1 15 atoms/cm 2 Molecular Desorption Region Why TOF-SIMS?

More information

J. Mass Spectrom. Soc. Jpn. Vol. 50, No. 6, 2002 COMMUNICATION Hydrogen-Attachment Dissociation (HAD) The Characteristics of In-source Decay in Mass S

J. Mass Spectrom. Soc. Jpn. Vol. 50, No. 6, 2002 COMMUNICATION Hydrogen-Attachment Dissociation (HAD) The Characteristics of In-source Decay in Mass S J. Mass Spectrom. Soc. Jpn. Vol. 50, No. 6, 2002 COMMUNICATION Hydrogen-Attachment Dissociation (HAD) The Characteristics of In-source Decay in Mass Spectrometric Degradation Methods Hydrogen-Attachment

More information

PowerPoint プレゼンテーション

PowerPoint プレゼンテーション Mass Spectroscopy(MS) EI electron impact, electron impact ionization, electron bombardment ionization ( ) IUPAC electron ionization ( ) ( 31 (1997)) MS m/z( / ) 1 C 12.011 C 98.9% 13 C 1.1% m/z m z m/z

More information

Neutron yield M.R. Hawkesworth, Neutron Radiography: Equipment and Methods, Atomic Energy Review 15, No. 2, , n µc -1 = n/(µa s) ~10 12 n

Neutron yield M.R. Hawkesworth, Neutron Radiography: Equipment and Methods, Atomic Energy Review 15, No. 2, , n µc -1 = n/(µa s) ~10 12 n Cross Section 7MeV Proton Linac AFRD, LBL (courtesy of Jani Reionen) LINAC SYSTEMS Applied Pulsed Power Plasma Target D+D reaction driven by LASER Neutron yield M.R. Hawkesworth, Neutron Radiography: Equipment

More information

J. Mass Spectrom. Soc. Jpn.: 58(5), (2010)

J. Mass Spectrom. Soc. Jpn.: 58(5), (2010) J. Mass Spectrom. Soc. Jpn. Vol. 58, No. 5, 2010 REVIEW 9 Secondary Ion Mass Spectrometry (SIMS) SIMS SIMS Fundamentals of Mass Spectrometry Secondary Ion Mass Spectrometry (SIMS), Cluster SIMS, and Electrospray

More information

2

2 1 = 2 3 r \ 1.1.1 Titrator 1.1 4 1.1.2 Polarograph 5 1.1.3.1 Electrolytic analyzer 1.1.3.2 Coulometric analyzer 6 1.1.4.1 ph ORP ph meter and ORP meter 7 ph ORP 1.1.4.2 Electrode type oxgen meter 8 DO

More information

橡マニュアルv4c.PDF

橡マニュアルv4c.PDF LC/MS MS LC/MS LC LC (APCI) (ESI) FAB 2 LC (APCI) 4.1.1.1 LC LC/MS LC MS LC 3 ph APCI/MS LC (1) APCI ESI 100% 100% ESI 4.1.1-1 LC 1.00cp 100 34 a 4.1.1-1 LC b ( /mpas) n- 0.23 36 0.5 99 0.31 69 n- 0.92

More information

Microsoft Word - 5MS.doc

Microsoft Word - 5MS.doc 5 5.1 mass spectrometer electron impact, EI 5.1 :;"< 789 =>? *!"#$%& '%&(),,,-./ 0.12%3456 :;"@AB CDEFG:;"HIJK@LMN :;"@HIOPQ0RST6 5.1. 70 ev molecular ion #"$%& M M e!"!"'() #" m/z ; m = z = 1 mass spectrum,

More information

バイオ解析チーム教育セミナーMS04

バイオ解析チーム教育セミナーMS04 LTQ Orbitrap Shotgun proteomics Large scale proteomics by orbitrap technology. Thermo fisher scientific K.K SID C&MS Application OMICS Team TMT 2 Proteome Cell and Tissue Protein Peptide Extraction Protease

More information

low_ JAJP.qxd

low_ JAJP.qxd LC/MS Chad Borges, Matthew Slawson, James Taccogno, and Dennis Crouch Center for uman Toxicology University of Utah Salt Lake City, UT USA John M. ughes Agilent Technologies, Inc. Pleasanton, CA USA (oa-tof)

More information

Canvas-tr01(title).cv3

Canvas-tr01(title).cv3 Working Group DaiMaJin DaiRittaikaku Multiparticle Jiki-Bunnsekiki Samurai7 Superconducting Analyser for Multi particles from RadioIsotope Beams with 7Tm of bending power (γ,n) softgdr, GDR non resonant

More information

Japanese Journal of Pesticide Science 42(1): (2017)

Japanese Journal of Pesticide Science 42(1): (2017) 42(1), 203 203 215 (2017) DOI: 10.1584/jpestics.W17-54 1, * 2, ** 3, *** 4, **** 4 1 2 3 4 2017 1 6 Recent data analysis technique in mass spectrometry Takaya Satoh, 1 Kentaro Takahara, 2 Tomoaki Kondo,

More information

03J_sources.key

03J_sources.key Radiation Detection & Measurement (1) (2) (3) (4)1 MeV ( ) 10 9 m 10 7 m 10 10 m < 10 18 m X 10 15 m 10 15 m ......... (isotope)...... (isotone)......... (isobar) 1 1 1 0 1 2 1 2 3 99.985% 0.015% ~0% E

More information

atomic line spectrum emission line absorption line atom proton neutron nuclei electron Z atomic number A mass number neutral atom ion energy

atomic line spectrum emission line absorption line atom proton neutron nuclei electron Z atomic number A mass number neutral atom ion energy 1 22 22.1 atomic line spectrum emission line absorption line atom proton neutronnuclei electron Z atomic number A mass number neutral atom ion energy level ground stateexcited state ionized state 22.2

More information

42 3 u = (37) MeV/c 2 (3.4) [1] u amu m p m n [1] m H [2] m p = (4) MeV/c 2 = (13) u m n = (4) MeV/c 2 =

42 3 u = (37) MeV/c 2 (3.4) [1] u amu m p m n [1] m H [2] m p = (4) MeV/c 2 = (13) u m n = (4) MeV/c 2 = 3 3.1 3.1.1 kg m s J = kg m 2 s 2 MeV MeV [1] 1MeV=1 6 ev = 1.62 176 462 (63) 1 13 J (3.1) [1] 1MeV/c 2 =1.782 661 731 (7) 1 3 kg (3.2) c =1 MeV (atomic mass unit) 12 C u = 1 12 M(12 C) (3.3) 41 42 3 u

More information

Donald Carl J. Choi, β ( )

Donald Carl J. Choi, β ( ) :: α β γ 200612296 20 10 17 1 3 2 α 3 2.1................................... 3 2.2................................... 4 2.3....................................... 6 2.4.......................................

More information

2

2 Rb Rb Rb :10256010 2 3 1 5 1.1....................................... 5 1.2............................................. 5 1.3........................................ 6 2 7 2.1.........................................

More information

02-量子力学の復習

02-量子力学の復習 4/17 No. 1 4/17 No. 2 4/17 No. 3 Particle of mass m moving in a potential V(r) V(r) m i ψ t = 2 2m 2 ψ(r,t)+v(r)ψ(r,t) ψ(r,t) Wave function ψ(r,t) = ϕ(r)e iωt steady state 2 2m 2 ϕ(r)+v(r)ϕ(r) = εϕ(r)

More information

橡A PDF

橡A PDF 2 1 MS 300 TRT MS JDI-800 2 g MS Py MS GC Py-GC Py GC 50 Py MS MS Py GC PY-GC 2 JDI-800 MS JDI-800 QP 2000 QP 1000 QP 2000 Fig 1 QP 1000 CI PEG 300 600 423 MS EI CI MS PEG 3 10 g Fig.1 300 600 MS 3 JDI-800

More information

4/15 No.

4/15 No. 4/15 No. 1 4/15 No. 4/15 No. 3 Particle of mass m moving in a potential V(r) V(r) m i ψ t = m ψ(r,t)+v(r)ψ(r,t) ψ(r,t) = ϕ(r)e iωt ψ(r,t) Wave function steady state m ϕ(r)+v(r)ϕ(r) = εϕ(r) Eigenvalue problem

More information

2 X-ray 6 gamma-ray 7 1 17.1 0:38m 0:77m nm 17.2 Hz Hz 1 E p E E = h = ch= (17.2) p = E=c = h=c = h= (17.3) continuum continuous spectrum line spectru

2 X-ray 6 gamma-ray 7 1 17.1 0:38m 0:77m nm 17.2 Hz Hz 1 E p E E = h = ch= (17.2) p = E=c = h=c = h= (17.3) continuum continuous spectrum line spectru 1 17 object 1 observation 17.1 X electromagnetic wave photon 1 = c (17.1) c =3 10 8 ms ;1 m mm = 10 ;3 m m =10 ;6 m nm = 10 ;9 m 1 Hz 17.1 spectrum radio 2 infrared 3 visual light optical light 4 ultraviolet

More information

薬物分析法の開発

薬物分析法の開発 API5000 TM LC/MS/MS Junichi_Hirokawa@trc.toray.co.jp 1. LC/MS/MS 2. 3. MS/MS 4. 5. API5000 6. 7. 8. 1. LC/MS/MS API 5000 AB/MDS Sciex UPLC API 4000 AB/MDS Sciex Agilent1100 PAL PAL ew wash 4000 QTRAP AB/MDS

More information

平成26年度 化学物質分析法開発報告書

平成26年度 化学物質分析法開発報告書 N,N- N,N-Dimethylacetamide Acethyldimethylamine CAS 127-19-5 C 4 H 9 NO 87.12 ~ 87.14 87.68413 163-165 C 1) - 18.59 C 2) 1 mg/l 25 C 3) 3.3 hpa 2 C 4) log P ow -.77 2).9429 2/4 C 1) 3.1 4) 1.31E - 8 atm-m

More information

食糧 その科学と技術 No.46( )

食糧 その科学と技術 No.46( ) , IARC A ppb ppm, WHOµg/L GC GC GCMS GC MS, d O O O NH 2 Br 2 NEt 3 Br NH 2 NH 2 Br Br GC, [C H NO Br] + m/z [C H NO Br] m/z SIM [C H D NO Br] m/z [C H D NO Br] + m/z Br Br HBr [C H NO Br] + m/z GC -d

More information

J. Mass Spectrom. Soc. Jpn., 64(6) (2016)

J. Mass Spectrom. Soc. Jpn., 64(6) (2016) J. Mass Spectrom. Soc. Jpn. Vol. 64, No. 6, 2016 REVIEW New Ion Collector for Elemental and Isotope Imaging 1, * 2 2 2 2,3 Takafumi Hirata, Michitaka Tanaka, Hideyuki O-bayashi, Kentaro Hattori, and Shuhei

More information

2 1 7 - TALK ABOUT 21 μ TALK ABOUT 21 Ag As Se 2. 2. 2. Ag As Se 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 Sb Ga Te 2. Sb 2. Ga 2. Te 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 1 2 3 4

More information

輻射の量子論、選択則、禁制線、許容線

輻射の量子論、選択則、禁制線、許容線 Radiative Processes in Astrophysics 005/8/1 http://wwwxray.ess.sci.osaka- u.ac.jp/~hayasida Semi-Classical Theory of Radiative Transitions r r 1/ 4 H = ( cp ea) m c + + eφ nonrelativistic limit, Coulomb

More information

COE

COE COE COOL05 MD @ @ @ @ n ν x, y 2 2 International Workshop on Beam Cooling and Related Topics ( COOL05) General Topics Overview. S-LSR Report from Lab Report from Lab Electron Cooling Muon Cooling

More information

2章.doc

2章.doc C 2 H 4 N 2 O 2 LPG LIF 13 2.1 2.1.1 2.1 2.2 115mm70mm 727cm 3 Hand Pump Injector Driver Computer Constant Volume Chamber Injector Piezo-electronic transducer Fan Spark Plug Temperature Indicator C 2 H

More information

ミューオンによる非破壊分析の可能性_toyoda

ミューオンによる非破壊分析の可能性_toyoda Ion Source Detector = Δ T 2 Δ T 12 6 C 6 + 6 13 6 C 6 + 7 R = / Δ 5% Δ 10% +Δ 大阪大学大分散質量分析器 H. Matsuda, S. Fukuoto, Y. Kuroda, Z. Naturforschg., 21a (1966), 25-33. S. Fukuoto, T. Matsuo and H. Matsuda,

More information

36 th IChO : - 3 ( ) , G O O D L U C K final 1

36 th IChO : - 3 ( ) , G O O D L U C K final 1 36 th ICh - - 5 - - : - 3 ( ) - 169 - -, - - - - - - - G D L U C K final 1 1 1.01 2 e 4.00 3 Li 6.94 4 Be 9.01 5 B 10.81 6 C 12.01 7 N 14.01 8 16.00 9 F 19.00 10 Ne 20.18 11 Na 22.99 12 Mg 24.31 Periodic

More information

Mott散乱によるParity対称性の破れを検証

Mott散乱によるParity対称性の破れを検証 Mott Parity P2 Mott target Mott Parity Parity Γ = 1 0 0 0 0 1 0 0 0 0 1 0 0 0 0 1 t P P ),,, ( 3 2 1 0 1 γ γ γ γ γ γ ν ν µ µ = = Γ 1 : : : Γ P P P P x x P ν ν µ µ vector axial vector ν ν µ µ γ γ Γ ν γ

More information

01-表紙.ai

01-表紙.ai B 0 5 0-5 双極子核 I=1/ 2 四極子核 I 1 e Li Be B C N F Ne Na Mg 黒字はNMR 観測不可 Al Si P S Cl Ar K Ca Sc Ti V Cr MnFe Co Ni Cu ZnGaGe As Se Br Kr RbSr Y Zr NbMoTc RuRhPdAgCd In Sn SbTe I Xe Cs Ba La f Ta W Res Ir Pt

More information

rcnp01may-2

rcnp01may-2 E22 RCP Ring-Cyclotron 97 953 K beam K-atom HF X K, +,K + e,e K + -spectroscopy OK U U I= First-order -exchange - coupling I= U LS U LS Meson-exchange model /5/ I= Symmetric LS Anti-symmetric LS ( σ Λ

More information

Outline Purpose Introduction of FFAG at KURRI Experiment Result Summary Future

Outline Purpose Introduction of FFAG at KURRI Experiment Result Summary Future Measurement of betatron tunes in KURRI FFAG Main ring Y.Takahoko (FUKUI university) M.Takashima (KYOTO university) Y.Kuriyama (KYOTO university) 1 Outline Purpose Introduction of FFAG at KURRI Experiment

More information

untitled

untitled Tokyo Institute of Technology high-k/ In.53 Ga.47 As MOS - Defect Analysis of high-k/in.53 G a.47 As MOS Capacitor using capacitance voltage method,,, Darius Zade,,, Parhat Ahmet,,,,,, ~InGaAs high-k ~

More information

110 B U N S E K I K A G A K U Vol Fig. 1 system Schematic diagram of the plasma measurement Fig. 2 Photograph of a time-resolved obserbation

110 B U N S E K I K A G A K U Vol Fig. 1 system Schematic diagram of the plasma measurement Fig. 2 Photograph of a time-resolved obserbation BUNSEKI KAGAKU Vol. 63, No. 2, pp. 109-117 2014 2014 The Japan Society for Analytical Chemistry 109 ICP 1 1 1 1 0.1 1 nl ICP ICP ICP He-ICP 3.4 khz Ar-ICP 17.3 khz He-ICP 24 ms Ar-ICP 130 ms He-ICP 3000

More information

Drift Chamber

Drift Chamber Quench Gas Drift Chamber 23 25 1 2 5 2.1 Drift Chamber.............................................. 5 2.2.............................................. 6 2.2.1..............................................

More information

Microsoft PowerPoint - TMTinst_ _summerschool_akiyama

Microsoft PowerPoint - TMTinst_ _summerschool_akiyama 1 2 3 4 5 6 7 8 9 10 590nm 2200nm 0 1.739 1.713 5 1.708 1.682 10 1.678 1.652 0-10 0.061061 0.061061 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 1.0 x1.0 0.5 x0.5 0.2 x0.2 0.1 x0.1 bg/30ms

More information

日本電子 newsVol.47 No.1 (2015)

日本電子 newsVol.47 No.1 (2015) ISSN 0386-6572 August 2015 Vol.47 No.1 Contents August 2015 Vol.47 No.1 100 nm 1 news Vol.47 No.1 (2015) news Vol.47 No.1 (2015) 2 3 news Vol.47 No.1 (2015) news Vol.47 No.1 (2015) 4 5 news Vol.47 No.1

More information

Taro9-111化兵条約法令集(和文)

Taro9-111化兵条約法令集(和文) :The Legal Texts 3. / 8. 6 8.1 8.1.1 C-I/DEC.35 8.1.2 6 C-II/DEC.6 8.1.3 C-I/DEC.38 8.1.4 C-I/DEC.33 8.1.5 C-I/DEC.40 8.1.6 C-I/DEC.34 8.1.7 C-I/DEC.36 8.1.8 EC-XIX/DEC.5 8.2 1 8.2.1 1 1 C-I/DEC.43 8.2.2

More information

Telescope aperture 1.5mφ Telescope length Fit within the H-IIA nose fairing Spatial resolution 0.1" in UV 0.16" in Vis/NIR (Diffraction limit of 1.5mφ

Telescope aperture 1.5mφ Telescope length Fit within the H-IIA nose fairing Spatial resolution 0.1 in UV 0.16 in Vis/NIR (Diffraction limit of 1.5mφ , (NAOJ) (Kyoto U.) Telescope aperture 1.5mφ Telescope length Fit within the H-IIA nose fairing Spatial resolution 0.1" in UV 0.16" in Vis/NIR (Diffraction limit of 1.5mφ at 1µm ) FOV ~200" x 200" to cover

More information

untitled

untitled MALDI-TOF-MS : imaging X (MRI/MRS) (CT) (PET) 2009 8 8 ( ) 15:39 UTC Imaging mass spectrometry(ims) MALDI (Matrix-Assisted Laser Desorption Ionization ) SIMS (Secondary Ion Mass Spectrometry) DESI (desorption

More information

1 WSV SIR m/z Analyte RT (Min) SIR m/z Cone voltage (V) Ascorbic Acid (C).91 177 2 Thiamine (B1) 1.1 265 5 Nicotinic Acid (B3) 1.27 124 15 Pyridoxal (

1 WSV SIR m/z Analyte RT (Min) SIR m/z Cone voltage (V) Ascorbic Acid (C).91 177 2 Thiamine (B1) 1.1 265 5 Nicotinic Acid (B3) 1.27 124 15 Pyridoxal ( ACQUITY UPLC H-Class ACQUITY QDa Mark E. Benvenuti, Dimple Shah, and Jennifer A. Burgess Waters Corporation, Milford, MA, USA MS ACQUITY QDa UPLC HPLC UV ACQUITY QDa LC EC 1925/26 CFR 21 HPLC 1 LC-MS ACQUITY

More information

HIGIS 3/プレゼンテーション資料/J_GrayA.ppt

HIGIS 3/プレゼンテーション資料/J_GrayA.ppt Static SIMS SIMS 研究会 7 2016.07.20 成蹊大学 応用技術部東京応用技術一課伊澤智香 SIMS の基本原理 一次ビームイオンビーム (Ga + Au n+ Bi n+ O 2+ Cs + Ar + Xe +...) 加速電圧 :5-25 kev 固体内での衝突カスケード (Collision cascade) 二次粒子 中性粒子 電子 二次イオン (+/-) Dynamic

More information

untitled

untitled SPring-8 RFgun JASRI/SPring-8 6..7 Contents.. 3.. 5. 6. 7. 8. . 3 cavity γ E A = er 3 πε γ vb r B = v E c r c A B A ( ) F = e E + v B A A A A B dp e( v B+ E) = = m d dt dt ( γ v) dv e ( ) dt v B E v E

More information

J. Mass Spectrom. Soc. Jpn. Vol. 57, No. 2, 2009 Optimization of a Home-Built Desorption Electrospray Ionization Source and Its Application in Rapid A

J. Mass Spectrom. Soc. Jpn. Vol. 57, No. 2, 2009 Optimization of a Home-Built Desorption Electrospray Ionization Source and Its Application in Rapid A 脱離エレクトロスプレーイオン化質量分析用イオン源 Title の試作と迅速分析への応用 芳本, 有史, 元木, 翔一, 森脇, 悠介, 川崎, 英也, Author(s) 荒川, 隆一 Journal of the Mass Spectrometry Citation n, 57(2): 109-115 Issue Date 2009 URL http://hdl.handle.net/10112/6001

More information

資料5.2 平成18 年度大気中有害金属実測調査計画(案)

資料5.2 平成18 年度大気中有害金属実測調査計画(案) 1. 2. 3. 3.1 1) CVAAS) CVAFS) AES 3.2 4. 5. 6. 6.1 6.2 6.3 Vender Product Measurements Detection Technique Characteristics PS Analytical Tekran Thermo Electron Durag/Verewa EcoChem Analytics Forney MIP

More information

平成26年度 化学物質分析法開発報告書

平成26年度 化学物質分析法開発報告書 2,2-2,2 -Iminodiethanol Diethanol amine CAS 111-42-2 C 4 H 11 NO 2 105.1356-105.0790-28 C 1) 1.0881 g/cm 3 1)

More information

LC/TOF-MS MS ( )

LC/TOF-MS MS ( ) LC/TOF-MS MS () (TOF-MS) MS) LC/MS 1. 2. Agilent 1100 LC/TOF-MS MS ~0.25ppm / C ambient Compound Exact mass Positive Negative Purine 121.050873 TFA 112.985587 Hexakis(1H, 1H, 3H 922.009798 966.000725 1)

More information

<4D F736F F D F90858C6E5F C B B B838B>

<4D F736F F D F90858C6E5F C B B B838B> Isobutyl alcohol IUPAC 2-methylpropan-1-ol 2--1-2-Methyl-1-Propanol, Isobutanol CH 3 H 3 C OH CAS 78-83-1 C 4 H 10 O log P ow ( C) ( C) (kpa) (g/l) 74.12 74.14 1) -108 2) 108 2) 1.2 2) 87 2) 0.8 2) (74.1214)

More information

JAJP

JAJP Agilent 7500ce ORS ICP-MS Glenn Woods Agilent Technologies Ltd. 5500 Lakeside, Cheadle Royal Business Park Stockport UK Agilent 7500ce ICP-MS 5 7500ce (ORS) 1 ORS 7500ce ORS ICP-MS ( ) 7500 ICP-MS (27.12

More information

TSP-MPS-OM.book

TSP-MPS-OM.book 取扱説明書 Transpector MPS Transpector MPH www.inficon.com 2014 INFICON reachus@inficon.com INFICON Inc. Two Technology Place East Syracuse, NY 13057 USA PN 074-603-P1A 1-1 PN 074-603-P1A 1-2 PN 074-603-P1A

More information

hν 688 358 979 309 308.123 Hz α α α α α α No.37 に示す Ti Sa レーザーで実現 術移転も成功し 図 9 に示すよ うに 2 時間は連続測定が可能な システムを実現した Advanced S o l i d S t a t e L a s e r s 2016, JTu2A.26 1-3. 今後は光周波 数比計測装置としてさらに改良 を加えていくとともに

More information

LCMS14003:UHPLC-Orbitrap質量分析計による環境汚染物質のターゲット分析、ノンターゲット分析

LCMS14003:UHPLC-Orbitrap質量分析計による環境汚染物質のターゲット分析、ノンターゲット分析 UHPLC Orbitrap Application Note LCMS14003 Orbitrap CEC CEC 61 CEC 312 CEC SPE UHPLCThermo Scientifi c Orbitrap Thermo Scientifi c TraceFinder WWTP S1 PS 5 ºC S2 TWAS 5 ºC 1 WWTP 1 2 WWTP 2 1 2 S1 1 S2

More information

42 1 Fig. 2. Li 2 B 4 O 7 crystals with 3inches and 4inches in diameter. Fig. 4. Transmission curve of Li 2 B 4 O 7 crystal. Fig. 5. Refractive index

42 1 Fig. 2. Li 2 B 4 O 7 crystals with 3inches and 4inches in diameter. Fig. 4. Transmission curve of Li 2 B 4 O 7 crystal. Fig. 5. Refractive index MEMOIRS OF SHONAN INSTITUTE OF TECHNOLOGY Vol. 42, No. 1, 2008 Li 2 B 4 O 7 (LBO) *, ** * ** ** Optical Scatterer and Crystal Growth Technology of LBO Single Crystal For Development with Optical Application

More information

電磁加速プラズマ流の制御と マッハプローブの特性評価

電磁加速プラズマ流の制御と マッハプローブの特性評価 7 004 3 19 e-mail : tobari@ecei.tohoku.ac.jp Keywords : Plasma Flow, Mach Probe, Plasma Acceleration, Electric Propulsion, MPD Thruster Outline 1. Introduction. Electric Propulsion 3. Mach Probe Experiment

More information

PowerPoint Presentation

PowerPoint Presentation JAERI-ISOL 20MV Tandem Accelerator Tokai site of JAEA JAERI-ISOL 200916, 7 80 85 90 95 00 05 10 ISOL : Isotope Separator On-Line 198012 RI 121 La β/γ La, Ba 144 Ce, 143 Pr hfs Q β log [i(mo + )/i(m + )]

More information

Sigma-Aldrich (Poole,Dorset,UK) LGC Standards(Teddington,Surrey,UK) 1 mg/ml Sigma-Aldrich Greyhound Chromatography(Brikenhead,UK) / Waters ACQUITY UPL

Sigma-Aldrich (Poole,Dorset,UK) LGC Standards(Teddington,Surrey,UK) 1 mg/ml Sigma-Aldrich Greyhound Chromatography(Brikenhead,UK) / Waters ACQUITY UPL ACQUITY UPLC I-Class/Xevo TQD Mark Roberts and Michelle Wood Waters Corporation, MS Technologies Centre, Manchester, UK ACQUITY UPLC I-Class/Xevo TQD 2 2 MRM 178 / 950 MS ACQUITY UPLC/ACQUITY TQD 2 1-3

More information

EOS and Collision Dynamics Energy of nuclear matter E(ρ, δ)/a = E(ρ, )/A + E sym (ρ)δ 2 δ = (ρ n ρ p )/ρ 1 6 E(ρ, ) (Symmetric matter ρ n = ρ p ) E sy

EOS and Collision Dynamics Energy of nuclear matter E(ρ, δ)/a = E(ρ, )/A + E sym (ρ)δ 2 δ = (ρ n ρ p )/ρ 1 6 E(ρ, ) (Symmetric matter ρ n = ρ p ) E sy Nuclear collision dynamics and the equation of state We want to measure EOS. Measure T, P and ρ of matter... Prepare matter in the state we want to measure HI collisions What are taking place in collisions?

More information

(Blackbody Radiation) (Stefan-Boltzmann s Law) (Wien s Displacement Law)

(Blackbody Radiation) (Stefan-Boltzmann s Law) (Wien s Displacement Law) ( ) ( ) 2002.11 1 1 1.1 (Blackbody Radiation).............................. 1 1.2 (Stefan-Boltzmann s Law)................ 1 1.3 (Wien s Displacement Law)....................... 2 1.4 (Kirchhoff s Law)...........................

More information

平成26年度 化学物質分析法開発報告書

平成26年度 化学物質分析法開発報告書 2,2-2,2 -Iminodiethanol Diethanol amine CAS 111-42-2 C 4 H 11 NO 2 105.1356-105.0790-28 C 1) 1.0881 g/cm 3 1)

More information

スペースプラズマ研究会-赤星.ppt

スペースプラズマ研究会-赤星.ppt 14 1 1 1 1 Pauline Faure 1 1 2 3 (1: 2: JAXA 3: IHI) IHI (C)(No.21560819) ISAS(JAXA) ISO TC20/SC14 / (Spall) 60~90% 2 (Cone) 1% (Jetting) CDV11227 Committee Draft for Comments CDV11227 Witness plate Sabot

More information

元素分析

元素分析 : このマークが付してある著作物は 第三者が有する著作物ですので 同著作物の再使用 同著作物の二次的著作物の創作等については 著作権者より直接使用許諾を得る必要があります (PET) 1 18 1 18 H 2 13 14 15 16 17 He 1 2 Li Be B C N O F Ne 3 4 5 6 7 8 9 10 Na Mg 3 4 5 6 7 8 9 10 11 12 Al Si P

More information

RIBF 加速器での研究紹介 (加速器高度化チーム/低温技術チーム/大強度標的チーム)

RIBF 加速器での研究紹介 (加速器高度化チーム/低温技術チーム/大強度標的チーム) RIBF の紹介 RIBF 加速器複合系 荷電変換装置の開発 プラズマストリッパーの開発計画 大強度ウランビーム生成用プラズマストリッパーの開発計画理研奥野広樹 RI Beam Factory (RIBF) Operation of RIBF (1997~) The world s most intense RI Beams over the whole range of atomic masses

More information

75 unit: mm Fig. Structure of model three-phase stacked transformer cores (a) Alternate-lap joint (b) Step-lap joint 3 4)

75 unit: mm Fig. Structure of model three-phase stacked transformer cores (a) Alternate-lap joint (b) Step-lap joint 3 4) 3 * 35 (3), 7 Analysis of Local Magnetic Properties and Acoustic Noise in Three-Phase Stacked Transformer Core Model Masayoshi Ishida Kenichi Sadahiro Seiji Okabe 3.7 T 5 Hz..4 3 Synopsis: Methods of local

More information

fma20.PDF

fma20.PDF PZT TSC Measurement for Degraded and Damaged PZT Thin Films Capacitors Prepared by Sputtering. FeRAM MFIS : XRD, TEM : XRF, EDS, EPMA, SIMS : SPM, NDM? DLTS DLTS (TSC) (TSC) fatigue,, ( ) (1) (2) J T TSC

More information

mthesis.dvi

mthesis.dvi Study of multiple electron transfer processes to Highly charged ions with microcapillary targets : 96941 2001/01/19 1 5 1.1... 5 1.2... 6 1.2.1... 6 1.2.2 Classical over barrier(cob)... 7 1.2.3... 8 1.3...

More information

SPring8菅野印刷.PDF

SPring8菅野印刷.PDF 20021219Spring-8 Ah/kg Ah/dm 3 Li -3.01 540 3860 2090 Na -2.71 970 1160 1140 Al -1.66 2690 2980 8100 Zn -0.76 7140 820 5800 Fe -0.44 7850 960 7500 Cd -0.40 8650 480 4100 Pb -0.13 11340 260 2900 H 2 0

More information

MACS機器予算申請カタログ

MACS機器予算申請カタログ MACS Instruments MACSQuant automacs MultiMACS gentlemacs MACSmix TM MACSQuant 3 MACSQuant Analyzer 10 MACSQuant VYBMACSQuant X MACSQuant X Coming soon! 384 well plate Laser Channel Filter (nm) Dye or Parameter

More information

PowerPoint プレゼンテーション

PowerPoint プレゼンテーション Drain Voltage (mv) 4 2 0-2 -4 0.0 0.2 0.4 0.6 0.8 1.0 Gate Voltage (V) Vds [V] 0.2 0.1 0.0-0.1-0.2-10 -8-6 -4-2 0 Vgs [V] 10 1000 1000 1000 1000 (LSI) Fe Catalyst Fe Catalyst Carbon nanotube 1~2 nm

More information

untitled

untitled 1 Physical Chemistry I (Basic Chemical Thermodynamics) [I] [II] [III] [IV] Introduction Energy(The First Law of Thermodynamics) Work Heat Capacity C p and C v Adiabatic Change Exact(=Perfect) Differential

More information

藤村氏(論文1).indd

藤村氏(論文1).indd Nano-pattern profile control technology using reactive ion etching Megumi Fujimura, Yasuo Hosoda, Masahiro Katsumura, Masaki Kobayashi, Hiroaki Kitahara Kazunobu Hashimoto, Osamu Kasono, Tetsuya Iida,

More information

untitled

untitled TOF ENMA JAEA-RMS) TOF Pre-scission JAERI-RMS (m-state 16 O + 27 Al 150MeV d TOF Nucl. Phys. A444, 349-364 (1985). l = m d Pre-scission Scission 10-19 (Post_scission) (Pre-scission) Proton_fission Alpha_fission

More information

untitled

untitled 71 7 3,000 1 MeV t = 1 MeV = c 1 MeV c 200 MeV fm 1 MeV 3.0 10 8 10 15 fm/s 0.67 10 21 s (1) 1fm t = 1fm c 1fm 3.0 10 8 10 15 fm/s 0.33 10 23 s (2) 10 22 s 7.1 ( ) a + b + B(+X +...) (3) a b B( X,...)

More information

Microsoft PowerPoint - 藤田保険衛生大学

Microsoft PowerPoint - 藤田保険衛生大学 質量分析セミナー autoflex III LRF 韮澤崇 Bruker Daltonics K.K. MALDI Matrix Assisted Laser Desorption / Ionization マトリックス支援レーザー脱離イオン化 2 MALDI の基本原理 Matrix と Sample の混合結晶 LASER による Matrix の励起 脱離およびイオン化 ( プロトン化 ) LASER

More information

建築構造力学 I ( 第 3 版 ) サンプルページ この本の定価 判型などは, 以下の URL からご覧いただけます. このサンプルページの内容は, 第 3 版 1 刷発行時のものです.

建築構造力学 I ( 第 3 版 ) サンプルページ この本の定価 判型などは, 以下の URL からご覧いただけます.   このサンプルページの内容は, 第 3 版 1 刷発行時のものです. 建築構造力学 I ( 第 3 版 ) サンプルページ この本の定価 判型などは, 以下の URL からご覧いただけます. http://www.morikita.co.jp/books/mid/050043 このサンプルページの内容は, 第 3 版 1 刷発行時のものです. i 3 1 38 2 15 2 1 2 2 1 2 2 1977 2007 2015 10 ii F P = mα g =

More information

日本電子News Vol.41, 2009

日本電子News Vol.41, 2009 Vol. 41, 2009 Serving Advanced Technology Vol.41.2009...2...3...4...5...6...13...22...28...34...42...48, ü,,, ü, ü Example condition: 6kV, 120uA, 3hr Example Mehod: Back side Ar ion irradiation CP

More information

XPS分析のための簡易マニュアル

XPS分析のための簡易マニュアル XPS 200.. XPS XPS XPS XPS 1. N2 0.4MPa 2. ON PUMP 3. POWER SUPPLY CONTROL UNIT SPEC ON 4. POWER SUPPLY CONTROL UNIT X-R ON 0.4MPa RESET 5. X-RAY POWER UNIT (a) AUTO/MANUMANU (b) Al/MgMg (c) FILAMENT ON/OFFOFF

More information

untitled

untitled 1 Session 1 9 00 10 00 10 4 1 1-001 CBCT 1-002 CT 1-003 FOV 1-004 Area detector CT 1-005 CT Modulation Transfer Function 1 2 3 4 5 6 7 8 1-006 CT Noise power spectrum 1 2 3 4 5 67 8 Session 2 10 00 10

More information

untitled

untitled masato@icrr.u-tokyo.ac.jp 996 Start 997 998 999 000 00 00 003 004 005 006 007 008 SK-I Accident Partial Reconstruction SK-II Full reconstruction ( SK-III ( ),46 (40%) 5,8 (9%),9 (40%) 5MeV 7MeV 4MeV(plan)

More information

X線分析の進歩36 別刷

X線分析の進歩36 別刷 X X X-Ray Fluorescence Analysis on Environmental Standard Reference Materials with a Dry Battery X-Ray Generator Hideshi ISHII, Hiroya MIYAUCHI, Tadashi HIOKI and Jun KAWAI Copyright The Discussion Group

More information

positron 1930 Dirac 1933 Anderson m 22Na(hl=2.6years), 58Co(hl=71days), 64Cu(hl=12hour) 68Ge(hl=288days) MeV : thermalization m psec 100

positron 1930 Dirac 1933 Anderson m 22Na(hl=2.6years), 58Co(hl=71days), 64Cu(hl=12hour) 68Ge(hl=288days) MeV : thermalization m psec 100 positron 1930 Dirac 1933 Anderson m 22Na(hl=2.6years), 58Co(hl=71days), 64Cu(hl=12hour) 68Ge(hl=288days) 0.5 1.5MeV : thermalization 10 100 m psec 100psec nsec E total = 2mc 2 + E e + + E e Ee+ Ee-c mc

More information

2014_01_17_ishi_dist.key

2014_01_17_ishi_dist.key FFAG! 2 2014.1.17!!!!! 1.FFAG 2.FFAG 3. 4. 5. 6.FFAG 7. FFAG: Fixed Field Alternating Gradient B(r) =B(r 0 ) r r 0 k RF ( 6D-focusing i.e. x, px, y, py, s, ps ) RF gymnastics Bunching, Stacking etc. School,London,June

More information

untitled

untitled 213 74 AlGaN/GaN Influence of metal material on capacitance for Schottky-gated AlGaN/GaN 1, 2, 1, 2, 2, 2, 2, 2, 2, 2, 1, 1 1 AlGaN/GaN デバイス ① GaNの優れた物性値 ② AlGaN/GaN HEMT構造 ワイドバンドギャップ半導体 (3.4eV) 絶縁破壊電界が大きい

More information

Μ粒子電子転換事象探索実験による世界最高感度での 荷電LFV探索 第3回機構シンポジューム 2009年5月11日 素粒子原子核研究所 三原 智

Μ粒子電子転換事象探索実験による世界最高感度での 荷電LFV探索  第3回機構シンポジューム 2009年5月11日 素粒子原子核研究所 三原 智 µ COMET LFV esys clfv (Charged Lepton Flavor Violation) J-PARC µ COMET ( ) ( ) ( ) ( ) B ( ) B ( ) B ( ) B ( ) B ( ) B ( ) B 2016 J- PARC µ KEK 3 3 3 3 3 3 3 3 3 3 3 clfv clfv clfv clfv clfv clfv clfv

More information

QMI_10.dvi

QMI_10.dvi ... black body radiation black body black body radiation Gustav Kirchhoff 859 895 W. Wien O.R. Lummer cavity radiation ν ν +dν f T (ν) f T (ν)dν = 8πν2 c 3 kt dν (Rayleigh Jeans) (.) f T (ν) spectral energy

More information

a b Chroma Graphein Chromatography

a b Chroma Graphein Chromatography a b Chroma Graphein Chromatography (Stationary Phase) (Mobile Phase) CHROMATOGRAPHY GAS SFC LIQUID GSC GLC Column Planar NP RP IEC SEC TLC Paper Normal Phase Reverse Phase GPC GFC Thin Layer Chromato.

More information

iBookBob:Users:bob:Documents:CurrentData:flMŠÍ…e…L…X…g:Statistics.dvi

iBookBob:Users:bob:Documents:CurrentData:flMŠÍ…e…L…X…g:Statistics.dvi 4 4 9............................................... 3.3......................... 4.4................. 5.5............................ 7 9..................... 9.............................3................................4..........................5.............................6...........................

More information

Telescope Array FD SD SD

Telescope Array FD SD SD 2009 2010 3 T06MI051 2 4 1-1 4 1-2 5 1-3 Telescope Array 6 1-4 FD 9 1-5 SD 11 1-6 SD 15 1-7 16 17 2-1 17 2-1-1 17 2-1-2 18 2-2 20 2-3 21 2-4 23 2-4-1 23 2-4-2 24 2-5 28 2-5-1 30 2-5-2 31 2-5-3 32 2-5-4

More information

I 2 ESI - Ion Trap

I 2 ESI - Ion Trap I 2 ESI - Ion Trap 2011 35 ESI 520l/min 35V V Taylor 20 R N- ESI) Intens. x10 8 1.0 14+ 15+ 883.9 825.1 Cytochrome c 12000 Da 09123cyto mass00003.d: +MS 0.8 0.6 0.4 0.2 0.0 17+ 728.1 16+ 773.6 13+ 951.8

More information

LC-MS LC-MS NMR NMR LC-NMR [1] LC-NMR LC-NMR LC-NMR NMR [2] LC-NMR MHz NMR HPLC NMR LC-NMR LC-NMR LC-NMR WET water suppression enhanced through T1 eff

LC-MS LC-MS NMR NMR LC-NMR [1] LC-NMR LC-NMR LC-NMR NMR [2] LC-NMR MHz NMR HPLC NMR LC-NMR LC-NMR LC-NMR WET water suppression enhanced through T1 eff Technical Review LC-NMR How do you use liquid chromatography-nuclear magnetic resonance (LC-NMR) effectively for structural determinations of pharmaceutical impurities and metabolites? Toray Research Center,

More information

橡

橡 CO2 Laser Treatment of Tinea Pedis Masahiro UEDA:,' Kiyotaka KITAMURA** and Yukihiro GOKOH*** Table I Specifications 1. Kind of Laser 2. Wavelength of Lasers. Power of Laser. Radiation Mode. Pulse Duration.

More information

A Light source Power supply B Arbitrary unit (au) (Relative intensity) Arbitrary unit (au) (Relative intensity) Wave length : : 550-740 nm nm 160 160 120 120 80 80 40 40 5~20 cm cm Fan Fan3737 o C o C

More information

ヒト血漿中オキシステロールの高感度分析法

ヒト血漿中オキシステロールの高感度分析法 High sensitive determination of oxysterols in human plasma using gas chromatography-mass spectrometry (GC-MS) Saori Nakagawa and Susumu Yamato Oxysterols, cholesterol oxidation products, have been important

More information

pc725v0nszxf_j

pc725v0nszxf_j PC725NSZXF PC725NSZXF PC725NSZXF PC725 DE file PC725 Date Jun. 3. 25 SHARP Corporation PC725NSZXF 2 6 5 2 3 4 Anode Cathode NC Emitter 3 4 5 Collector 6 Base PC725NSZXF PC725YSZXF.6 ±.2.2 ±.3 SHARP "S"

More information

LM35 高精度・摂氏直読温度センサIC

LM35 高精度・摂氏直読温度センサIC Precision Centigrade Temperature Sensors Literature Number: JAJSB56 IC A IC D IC IC ( ) IC ( K) 1/4 55 150 3/4 60 A 0.1 55 150 C 40 110 ( 10 ) TO-46 C CA D TO-92 C IC CA IC 19831026 24120 11800 ds005516

More information